E5CN/E5CN-U (48 x 48 mm)

Similar documents
E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm)

E5CN/E5CN-U (48 x 48 mm)

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

Infrared port USB. Control Output 2. (built-in) SSR outputs

Programmable Temperature Controller (Digital Controller)

A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function.

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Series Temperature Controller Instruction Sheet

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Temperature Controllers

E5AN-H/E5EN-H. Advanced Digital Temperature Controller

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

02/11/2015

Series Digital Controller Instruction Sheet

TEMPERATURE CONTROLLER

Temperature Controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Digital Heater Element Burnout Detector K8AC-H

02/11/2015

Instruction manual Micro-computer based digital indicating controller

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Instruction manual for DIN rail mounting type indicating controller DCL-33A

SHIMADEN DIGITAL INDICATORS

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Process & TeMPerATUre UniversAl input DigiTAl MeTers

DIGITAL INDICATOR JIR-301-M

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Instruction manual Temperature Controller KT7

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

GCS-300 No.GCS31E

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

F4 Process Controller Installation and Operation Guide

Digital Temperature Controller E5AZ

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

Nov 08 PRODUCT SPECIFICATION SHEET

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

E5CN Temperature Controller User s Manual

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

RS485 MODBUS Module 8AI

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC100 Universal Digital Controller Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

7EF/7HF/7EC/7ES Temperature Controllers

Series Temperature Controller Instruction Sheet

DIGITAL INDICATOR DI25

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

General Specifications

I/A Series 716C 1/16 DIN Temperature Controller

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Temperature Controllers E5CSV

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

E5CN-FR Limit Controller USER S MANUAL

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

MICROJET RECORDER (180mm)

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Digital Temperature Controllers

MICROJET RECORDER (24-CHANNEL 180mm)

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

CN4800 Series CONTROLLER

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MICRO CONTROLLER S Z SERIES

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Table of Contents SECTION PAGE

+ A B V B NO NC V COM PV PV

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

370, boulevard de Balmont LYON Tel Fax Web:

Oakton TEMP 9500 Advanced Multiparameter Controller

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

OPERATOR S MANUAL. TDA-5B Aerosol Generator

Transcription:

Basic-type Digital Temperature Controller /-U (48 x 48 mm) New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. Indication Accuracy Thermocouple input: ±.3% of PV (previous models: ±.5%) Pt input: ±.% of PV (previous models: ±.5%) Analog input: ±.% FS (previous models: ±.5%) New -U s (Plug-in s) with analog inputs and current outputs. A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. Preventive maintenance for relays in the Temperature Controller using a Control Output / Counter. 48 48-mm 48 48-mm -U Refer to Safety Precautions on page 66. -U (48 x 48 mm) -H (48 x 48 mm) Main I/O Functions Event Inputs Two Sensor Inputs Universal thermocouple/pt inputs (s with temperature inputs) Analog current/voltage inputs (s with analog inputs) Indication Accuracy Thermocouple input: ±.3% of PV Pt input: ±.% of PV Analog input: ±.% FS Sampling Period 5 ms Control Output Voltage output (for driving SSR) -level Display: PV and SV Control Output ong-life relay output (hybrid) Auxiliary Outputs One Two 4-digit Display Auto/manual switching Temperature Controller status display Simple program function Control output / count alarm PV change rate alarm s also available with communications Operation This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. /E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H6) /E5AN/E5EN Digital Temperature Controllers Manual Basic Type (Cat. No. H8) Safety Precautions 3

/-U ineup -U (48 x 48 mm) Terminal block Temperature input control output control outputs control output or auxiliary outputs auxiliary outputs or auxiliary outputs Basic Type Analog input control outputs auxiliary outputs -H (48 x 48 mm) Safety Precautions Operation Note: s with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control. Number Structure Number egend Controllers -@@M@@-@-5 3 4 5 6 7. Control Output R: Q: C: Y: ong-life relay output (hybrid). Auxiliary Outputs Blank: : Two outputs 3. Option M: Option Unit can be mounted. 4. Input Type T: Universal thermocouple/platinum resistance thermometer : Analog current/voltage input 5. Power Supply Voltage Blank: to 4 VAC D: 4 VAC/VDC 6. Case Color Blank: Black W: Silver 7. Terminal Cover -5: With terminal cover Plug-in Temperature input Analog input Option Units E53-CN@@@ 3 4. Applicable Controller CN: or -H control output control output. Function Blank: Q: Control output (voltage for driving SSR) P: Power supply for sensor,, or auxiliary outputs,, or auxiliary outputs 3. Function Blank: H: Heater burnout/ssr failure/heater overcurrent detection (CT) HH: Heater burnout/ssr failure/heater overcurrent detection (CT) B: Two event inputs 3: communications H3: Heater burnout/ssr failure/heater overcurrent detection (CT) communications HB: Heater burnout/ssr failure/heater overcurrent detection (CT) Two event inputs HH3: Heater burnout/ssr failure/heater overcurrent detection (CT) communications 4. Version N: Applicable only to models released after January 8 Note: Not all combinations of function and function specifications are possible for Option Units (E53-@@@@).. Always connect an AC load to a long-life relay output. The output will not turn if a DC load is connected because a triac is used for switching the circuit. For details, check the conditions in Ratings.. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations. 4

Ordering Information Controllers with Terminal Blocks Size /6 DIN 48 48 78 (W H D) Case color Black Power supply voltage to 4 VAC 4 VAC/VDC Option Units One of the following Option Units can be mounted to provide the with additional functions. Silver Note: Option Units cannot be used for plug-in models. These Option Units are applicable only to models released after January 8. /-U Input type Auxiliary outputs Control output Thermocouple or Resistance thermometer Thermocouple or Resistance thermometer to 4 VAC Analog (current/voltage) 4 VAC/VDC to 4 VAC Analog (current/voltage) Thermocouple or Resistance thermometer 4 VAC/VDC 3-phase heater burnout/ssr failure/ Heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection Heater burnout/ssr failure/heater overcurrent detection 3-phase heater burnout/ssr failure/ Heater overcurrent detection Functions Event inputs Event inputs Event inputs Event inputs Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) Control output (Voltage for driving SSR) ong-life relay output (hybrid) ong-life relay output (hybrid) ong-life relay output (hybrid) External power supply for ESB External power supply for ESB External power supply for ESB -RMT-5 -QMT-5 -CMT-5 -RMT-5 -QMT-5 -CMT-5 -YMT-5 -RMTD-5 -QMTD-5 -CMTD-5 -RMTD-5 -QMTD-5 -CMTD-5 -RM-5 -QM-5 -CM-5 -RM-5 -QM-5 -CM-5 -YM-5 -RMD-5 -QMD-5 -CMD-5 -RMT-W-5 -QMT-W-5 -CMT-W-5 -RMT-W-5 -QMT-W-5 -CMT-W-5 -YMT-W-5 -RMTD-W-5 -QMTD-W-5 -CMTD-W-5 E53-CNHH3N E53-CNHBN E53-CNQ3N E53-CNPBN E53-CNPHN E53-CNP3N E53-CNH3N E53-CN3N E53-CNBN E53-CNQHN E53-CNQHHN E53-CNQBN -U (48 x 48 mm) -H (48 x 48 mm) Operation Safety Precautions 5

-U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation /-U Number Structure Number egend (Plug-in-type Controllers) -@@@U 3 4. Output Type R: Q: C:. Number of Alarms Blank: No alarm : One alarm : Two alarms Ordering Information Plug-in-type Controllers 3. Input Type T: Universal thermocouple/platinum resistance thermometer : Analog Input 4. Plug-in type U: Plug-in type Size Case color Power supply voltage Input type Auxiliary outputs Control output /6 DIN Black to 4 VAC 4 VAC/VDC Thermocouple or resistance thermometer Analog (current/voltage) Thermocouple or resistance thermometer -RTU -QTU -CTU -RTU -QTU -CTU -RTU -QTU -CTU -RU -QU -CU -RU -QU -CU -RTDU -QTDU -CTDU -RTDU -QTDU -CTDU -RTDU -QTDU -CTDU 6

Accessories (Order Separately) USB-Serial Conversion Cable Terminal Cover Connectable models E58-CIFQ Terminal block models E53-COV7 Note: The Terminal Cover comes with the -@@@-5 models. Waterproof Packing Y9S-9 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. Current Transformers (CTs) Hole diameter 5.8 dia. E54-CT. dia. E54-CT3 Adapter Connectable models Terminal block models /-U Note: Use this Adapter when the panel has been previously prepared for the E5B@. Sockets (for Plug-in s) Type Front-connecting Socket Front-connecting Socket with Finger Protection Back-connecting Socket Terminal Cover for Back-connecting socket with Finger Protection C-Thermo Support Software EST-C-MV4 Y9F-45 PCF- PCF--E P3GA- Y9A-48G -U (48 x 48 mm) Safety Precautions Operation -H (48 x 48 mm) 7

-U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation /-U Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Control outputs Auxiliary outputs -U Voltage output (for driving SSR) No D in model number: to 4 VAC, 5/6 Hz D in model number: 4 VAC, 5/6 Hz; 4 VDC 85% to % of rated supply voltage to 4 VAC: 7.5 VA (max.) (-RT at VAC: 3. VA) 4 VAC/VDC: 5 VA/3 W (max.) (-RTD at 4 VAC:.7 VA) to 4 VAC: 6 VA (max.) 4 VAC/VDC: 3 VA/ W (max.) (models with current output: 4 VA/ W) s with temperature inputs Thermocouple: K, J, T, E,, U, N, R, S, B, W, or P II Platinum resistance thermometer: Pt or JPt Infrared temperature sensor: to 7 C, 6 to C, 5 to 65 C, or to 6 C Voltage input: to 5 mv s with analog inputs Current input: 4 to ma or to ma Voltage input: to 5 V, to 5 V, or to V Current input: Ω max., Voltage input: MΩ min. (Use a : connection when connecting the ES-HB.) / control or -PID control (with auto-tuning) -U -U ST-NO, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma DT, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma Output voltage: VDC ±% (PNP), max. load current: ma, with short-circuit protection circuit 4 to ma DC/ to ma DC, load: 6 Ω max., resolution: approx., ong-life relay output Number of outputs Output specifications ST-NO, 5 VAC, 3 A (resistive load), electrical life:,, operations, load power supply voltage: 75 to 5 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, ma, leakage current: 5 ma max. (5 VAC, 6 Hz) or max. (Depends on the model.) : ST-NO, 5 VAC, 3 A (resistive load), electrical life:, operations, minimum applicable load: 5 V, ma Number of inputs Event External contact Contact input: : kω max., : kω min. inputs input specifications Non-contact input: : Residual voltage:.5 V max., : eakage current:. ma max. Current flow: Approx. 7 ma per contact External power supply for ESB VDC ±%, ma, short-circuit protection circuit provided Setting method Indication method Multi Bank switching Digital setting using front panel keys -segment digital display and individual indicators (7-segment display also possible) Character height: PV: mm, SV: 6.5 mm Up to four set points ( to 3) can be saved and selected using event inputs, key operations, or serial communications. Not supported Manual output, heating/cooling control, loop burnout alarm, ramp, other alarm functions, heater burnout detection, 4% AT, % AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, Other functions protection functions, control output / counter, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment Ambient operating temperature to 55 C (with no condensation or icing), for 3-year warranty: to 5 C Ambient operating humidity 5% to 85% Storage temperature 5 to 65 C (with no condensation or icing) 8

/-U Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Temperature range ( C) Input Type Platinum resistance thermometer s with Analog Inputs Shaded settings are the default settings. Thermocouple Name Pt JPt K J T E U N R S B W P II 3 8 7 6 9 8 7 6 5 4 3.. Setting number 7 7 85 85 85 Infrared temperature sensor 6 5. 5. 5. 4. 4 4. 4 4. 6 65.. 9.... 99.9 99.9 99.9 99.9 3 4 5 6 7 8 9 6 7 8 4 5 9 3 to 7 C 6 to C 5 to 65 C to 6 C Analog input to 5 mv -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation Shaded settings are the default settings. The applicable standards for the input types are as follows: K, J, T, E, N, R, S, B: JIS C 6-995, IEC 584- : Fe-CuNi, DIN 437-985 U: Cu-CuNi, DIN 437-985 W: W5Re/W6Re, ASTM E988-99 Input Type Current Voltage Input specification 4 to ma to ma to 5 V to 5 V to V Setting range Usable in the following ranges by scaling: 999 to 9999, 99.9 to 999.9, 9.99 to 99.99 or.999 to 9.999 Setting number 3 4 8 3 Usable in the following ranges by scaling: 999 to 9999 or 99.9 to 999.9 JPt: JIS C 64-989, JIS C 66-989 Pt: JIS C 64-997, IEC 75 P II: According to Platinel II electromotive force charts from BASF (previously Engelhard) 9

/-U -U (48 x 48 mm) -H (48 x 48 mm) Alarm Outputs Each alarm can be independently set to one of the following alarm types. The default is : Upper limit. Auxiliary outputs are allocated for alarms. delays and delays ( to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR failure alarm, and heater overcurrent alarm for alarm, set the alarm type to (i.e., no alarm function). Set value Alarm type Alarm function Upper- and lowerlimit Upper limit 3 ower limit 4 5 6 7 8 9 Upper- and lowerlimit range Upper- and lowerlimit with standby sequence Upper-limit with standby sequence ower-limit with standby sequence Absolute-value upper-limit Absolute-value lower-limit Absolute-value upper-limit with standby sequence Absolute-value lower-limit with standby sequence BA (for alarm only) PV change rate alarm Alarm output operation When is positive Output 5 --- --- H H H 3 4 When is negative. With set values, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as and H.. Set value:, Upper- and lower-limit alarm Case H H <, > H < Case H H >, < H > 3. Set value: 4, Upper- and lower-limit range Case H H <, > H < Case H H >, < H > Case 3 (Always ) 4. Set value: 5, Upper- and lower-limit with standby sequence For Upper- and ower-imit Alarm Described Above Case and Always when the upper-limit and lower-limit hysteresis overlaps. Case 3: Always 5. Set value: 5, Upper- and lower-limit with standby sequence Always when the upper-limit and lower-limit hysteresis overlaps. H H H Case 3 (Always ) H H H H <, < H <, > H H >, < H H <, < H <, > H H >, < H Safety Precautions Operation

/-U Characteristics Indication accuracy Influence of temperature Influence of voltage Input sampling period Hysteresis Thermocouple: Terminal block models (): (±.3% of indicated value or ± C, whichever is greater) ± digit max. Plug-in models (-U): (±% of indicated value or ± C, whichever is greater) ± digit max. Platinum resistance thermometer input: Terminal block models () and plug-in models (-U): (±.% of indicated value or ±.8 C, whichever is greater) ± digit max. Analog input: Terminal block models () and plug-in models (-U): ±.% FS ± digit max. CT input: Terminal block models (): ±5% FS ± digit max. Thermocouple input (R, S, B, W, P II): Terminal block models (): (±% of PV or ± C, whichever is greater) ± digit max. Plug-in models (-U): (±% of PV or ± C, whichever is greater) ± digit max. Other thermocouple input: 3 Terminal block models (): (±% of PV or ±4 C, whichever is greater) ± digit max. Plug-in models (-U): (±% of PV or ±4 C, whichever is greater) ± digit max. Platinum resistance thermometer input: Terminal block models () and plug-in models (-U): (±% of PV or ± C, whichever is greater) ± digit max. Analog input: Terminal block models () and plug-in models (-U): (±%FS) ± digit max. 5 ms s with thermocouple/platinum resistance thermometer input (universal input):. to 999.9 EU (in units of. EU) 4 s with analog input:. to 99.99% FS (in units of.% FS) Proportional band (P) s with thermocouple/platinum resistance thermometer input (universal input):. to 999.9 EU (in units of. EU) 4 s with analog input:. to 999.9% FS (in units of.% FS) Integral time (I) to 3999 s (in units of s) Derivative time (D) to 3999 s (in units of s) 5 Control period.5, to 99 s (in units of s) Manual reset value. to.% (in units of.%) Alarm setting range Affect of signal source resistance Insulation resistance Dielectric strength Vibration Malfunction resistance Destruction Shock Malfunction resistance Destruction Weight Degree of protection -U -U Memory protection Setup Tool Setup Tool port Standards EMC Approved standards 7 Conformed standards 999 to 9999 (decimal point position depends on input type) Thermocouple:. C/Ω max. ( Ω max.) Platinum resistance thermometer:. C/Ω max. ( Ω max.) MΩ min. (at 5 VDC),3 VAC, 5 or 6 Hz for min (between terminals with different charge) to 55 Hz, m/s for min each in, Y, and Z directions to 55 Hz,.75-mm single amplitude for hrs each in, Y, and Z directions m/s, 3 times each in, Y, and Z directions 3 m/s, 3 times each in, Y, and Z directions Controller: Approx. g, Mounting Bracket: Approx. g Controller: Approx. g, Mounting Bracket: Approx. g Front panel: IP66, Rear case: IP, Terminals: IP Front panel: IP5, Rear case: IP, Terminals: IP Non-volatile memory (number of writes:,, times) C-Thermo version 4. or higher Provided on the bottom of the. Use this port to connect a computer to the when using the Setup Tool. An E58-CIFQ USB-Serial Conversion Cable is required to connect the computer to the. 6 U 6-, CSA C. No. - EN 6- (IEC 6-): Pollution level, overcurrent category II EMI: EN 66 Radiated Interference Electromagnetic Field Strength: EN 55 Group, class A Noise Terminal Voltage: EN 55 Group, class A EMS: EN 66 ESD Immunity: EN 6-4- Electromagnetic Field Immunity: EN 6-4-3 Burst Noise Immunity: EN 6-4-4 Conducted Disturbance Immunity: EN 6-4-6 Surge Immunity: EN 6-4-5 Power Frequency Magnetic Field Immunity: EN 6-4-8 Voltage Dip/Interrupting Immunity: EN 6-4-. The indication accuracy of K thermocouples in the to C range, T and N thermocouples at a temperature of C max., and U and thermocouples at any temperatures is ± C ± digit max. The indication accuracy of the B thermocouple at a temperature of 4 C max. is not specified. The indication accuracy of B thermocouples in the 4 to 8 C range is ±3 C max. The indication accuracy of the R and S thermocouples at a temperature of C max. is ±3 C ± digit max. The indication accuracy of W thermocouples is ±.3 of PV or ±3 C, whichever is greater, ± digit max. The indication accuracy of P II thermocouples is ±.3 of PV or ± C, whichever is greater, ± digit max.. Ambient temperature: C to 3 C to 55 C, Voltage range: % to % of rated voltage 3. K thermocouple at C max.: ± max. 4. EU stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F. 5. When robust tuning (RT) is, the differential time is. to 999.9 (in units of. s). 6. External communications () and cable communications for the Setup Tool can be used at the same time. 7. The -U plug-in model is certified for U listing only when used together with the OMR PCF- or PCF--E Socket. The P3GA- is not certified for U listing. -U (48 x 48 mm) -H (48 x 48 mm) Operation Safety Precautions

/-U -U (48 x 48 mm) -H (48 x 48 mm) Safety Precautions Operation USB-Serial Conversion Cable Applicable OS Applicable software Windows, P, or Vista Thermo Mini, C-Thermo version 4. or higher Applicable models E5AN/E5EN//-U/E5AN-H/ E5EN-H/-H USB interface standard Conforms to USB Specification.. DTE speed Connector specifications Power supply Power supply voltage Current consumption Ambient operating temperature Ambient operating humidity 384 bps Computer: USB (type A plug) Temperature Controller: Setup Tool port (on bottom of Controller) Bus power (Supplied from USB host controller.) 5 VDC 7 ma to 55 C (with no condensation or icing) % to 8% Storage temperature to 6 C (with no condensation or icing) Storage humidity % to 8% Altitude Weight Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable. Specifications Transmission line connection method Synchronization method Protocol Baud rate Transmission code Data bit length Stop bit length Error detection Flow control Interface Retry function buffer response wait time, m max. Approx. g : Multipoint (two-wire, half duplex) Start-stop synchronization CompoWay/F, SYSWAY, or Modbus, 4, 48, 96, 9, 384, or 576 bps ASCII 7 or 8 bits or bits Vertical parity (none, even, odd) Frame check sequence (FCS) with SYSWAY Block check character (BCC) with CompoWay/F or CRC-6 Modbus 7 bytes to 99 ms Default: ms The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Setting evel. Current Transformer (Order Separately) Ratings Dielectric strength, VAC for min Vibration resistance 5 Hz, 98 m/s Weight Accessories (E54-CT3 only) E54-CT: Approx..5 g, E54-CT3: Approx. 5 g Armatures () Plugs () Heater Burnout Alarms, SSR Failure Alarms, and Heater Overcurrent Alarms CT input (for heater current detection) Maximum heater current Input current indication accuracy Heater burnout alarm setting range SSR failure alarm setting range Heater overcurrent alarm setting range 3 s with detection for single-phase heaters: One input s with detection for single-phase or three-phase heaters: Two inputs 5 A AC ±5% FS ± digit max.. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms. to 49.9 A (in units of. A) Minimum detection time: ms. For heater burnout alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is lower than the set value (i.e., heater burnout detection current value).. For SSR failure alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is higher than the set value (i.e., SSR failure detection current value). 3. For heater overcurrent alarms, the heater current will be measured when the control output is, and the output assigned to the alarm function will turn if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical ife Expectancy Curve for Relays (Reference Values) ife ( 4 operations) 5 3 5 3 5 3 5 VAC, 3 VDC (resistive load) cosφ = 3 4 5 6 Switching current (A) Note: Do not connect a DC load to a Controller with a ong-life Relay Output.

External Connections /-U A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. (If the control output terminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current.) Consult with your OMR representative before using the external power supply for the ESB for any other purpose. Controllers -U (48 x 48 mm) Control output ong-life relay output 5 VAC, 3 A (resistive load) 5 VAC, 3 A (resistive load) VDC, ma to ma DC 4 to ma DC oad: 6 Ω max. Control output VDC, ma Option Units E53-CNHH3N () and CT B() A( ) CT CT E53-CNH3N () and CT B() A( ) DO NOT CT Control output DO NOT DO NOT A ma B V DO NOT B TC/Pt Analog input universalinput E53-CNHBN Event inputs and CT EV EV CT E53-CN3N () B() A( ) DO NOT DO NOT DO NOT E53-CNQ3N () and Control Output B() A( ) DO NOT Control output E53-CNBN Event inputs EV EV DO NOT DO NOT Auxiliary outputs (relay outputs) 5 VAC, 3 A (resistive load) Auxiliary outputs (relay outputs) Auxiliary output Auxiliary output Input power supply to 4 VAC 4 VAC/VDC (no polarity) E53-CNPBN Event Inputs and External Power Supply EV EV External power supply VDC, ma E53-CNQHN Control Output and CT Control output DO NOT CT E53-CNPHN External Power Supply and CT External power supply DO NOT CT A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm function is assigned. VDC, ma E53-CNQHHN Control Output and CT Control output CT CT E53-CNP3N () and External Power Supply B() A( ) DO NOT External VDC, power supply ma E53-CNQBN Event Inputs and Control Output EV EV Control output -H (48 x 48 mm) -U Control output Control output (three terminals used) DT, 5 VAC, 3 A (resistive load) DO NOT DO NOT A Voltage output ma (for driving SSR) B VDC, ma V DO NOT 4 to ma DC B to ma DC oad: 6 W max. Analog input TC/Pt universal input Note: For the Wiring Socket, purchase the PCF- or PG3A- separately. Auxiliary output 5 VAC, 3 A (resistive load) (s) Auxiliary output Auxiliary output (Control output (cooling side)) Input power supply to 4 VAC 4 VAC/VDC (no polarity) An input error is sent to the output to which the alarm function is assigned. Operation Safety Precautions

/-U Nomenclature -U (48 x 48 mm) -U The front panel is the same for the and -U. Operation indicators Temperature unit No. display No. display evel Key Up Key Dimensions Mode Key Down Key (Unit: mm) -H (48 x 48 mm) Terminal s -U Plug-in s 48 48 48 48 58 6.5 9 78 Waterproof Mounting Adapter Packing (Accessory) (Accessory) 44.8 44.8 48.8 Terminal Cover (E53-COV7) (Accessory) Panel Cutout Mounted Separately 6 min. Note: The terminal block cannot be removed. (84.7) 6 7.5. 58 44.8 44.8 45.6 45.6 Panel Cutout Mounted Separately Group Mounted (48 number of units.5). Group mounting does not allow waterproofing. 45.6 Recommended panel thickness is to 5 mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) To mount the Controller so that it is waterproof, insert the waterproof packing onto the Controller. When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. Group Mounted (48 number of units.5). 45.6 Safety Precautions Operation Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ Mounting Adapter (Accessory) USB connector (type A plug) 6 min. 45.6 45.6 (,) 5 ED indicator (SD),765 ED indicator (RD) Recommended panel thickness is to 5 mm. Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. Serial connector

/-U Terminal Cover E53-COV7 48.8 48 Note: The E53-COV cannot be used. Waterproof Packing Y9S-9 (for DIN 48 48) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMR shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required. -U (48 x 48 mm) 9. Current Transformers E54-CT E54-CT3 5 3 4 3 3.8 5.8 dia..5 Two, 3.5 dia..36 dia. dia. 7.5 9 E54-CT Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: 5 A (5/6 Hz) Number of windings: 4± Winding resistance: 8± Ω Output voltage (Eo) V (r.m.s.) V 5 Hz mv μv kω Ω R = Ω Distortion factor % 3% % -H (48 x 48 mm) ma, A 4 4 Thru-current (Io) A (r.m.s.) 3 Two, M3 (depth: 4) E54-CT3 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current: A (5/6 Hz) (Maximum continuous heater current for the Temperature Controller is 5 A.) Number of windings: 4± Winding resistance: 8±.8 Ω Operation E54-CT3 Accessory Armature Approx. 3 dia. Plug Approx. 6 dia. () 8 Connection Example Armature Plug ead Output voltage (Eo) V (r.m.s.) V 5 Hz mv μv kω 5 Ω Ω 5 Ω R = Ω Distortion factor % 3% % ma, A Thru-current (Io) A (r.m.s.) Safety Precautions

/-U -U (48 x 48 mm) Adapter Y9F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. 4.7 76 69.6 to 77.6 7 7 Fixture (Accessory) 67 67 87 Mounted to 7 7 Panel ( to 8 mm) -H (48 x 48 mm) 48 48. 4.7 77.3 (to back of ) -U Wiring Socket Front-connecting Socket PCF- Eleven, M3.5 7.5 sems screws 7.8 7 max. Two, 4.5-dia. holes 3 4.5 35.4 Terminal ayout/internal Connections (Top View) 8 7 6 5 4 9 3 Mounting Holes Two, 4.5 dia. mounting holes 4±. Note: Can also be mounted to a DIN track. 4 5 max. 3. max. Note: A model with finger protection (PCF--E) is also available. Safety Precautions Operation Back-connecting Socket P3GA- 45 7 dia. 45 4.5 6.3 6. Note:. Using any other sockets will adversely affect accuracy. Use only the specified sockets.. A Protective Cover for finger protection (Y9A-48G) is also available. 5.6 8.7 4 7 3 Terminal ayout/internal Connections (Bottom View) 5 6 7 8 4 6 3 9 6