- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Similar documents
Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

- User Brochure Programmable Thermostat 510

- User Brochure tekmarnet 4 Setpoint Control 161

Radiant Thermostat 519

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

- Data Brochure Mixing Reset Module 421

- Data Brochure D 261. Boiler Control 261

- Installation & Operation Manual Boiler Control 256

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

- Data Brochure D 260. Boiler Control /09

- Data Brochure Steam Control 279

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

- Application Boiler Control 260

- Data Brochure Mixing Control 360

U538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

- Data Brochure D 665. Snow Detector & Melting Control /12

- Data Brochure Addendum

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Data Brochure Addendum

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

Installation & Operation Manual

- Data Brochure Universal Reset Module 423

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure tekmarnet 4 Thermostat 542e

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Ultrasonic Reflective Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Installation & Operation Manual

SMART 1000 Touchscreen Thermostat Installation Manual

- Data Brochure Mixing Control 361

- Data Brochure Boiler Control 264

VX SERIES Wireless Thermostat with Occupancy Sensor

ProRadiant Basic Heating Control Installation Manual 2013

Non-Programmable Digital Thermostat

Installation & Operation Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

4 Wiring Brochure Wiring and

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation & Operation Manual

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Universal Reset Module 422

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

Installation, Operation & Service Manual

Easy installation in both new construction and retrofit

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

View the expanded manual: GEN5

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Installation Instructions

HTLS. Heat Tracing Line Sensing Control Panel

INSTRUCTION MANUAL P Heating and 1 Cooling

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

FloorHeat Installation Manual

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Better Design, Better Control, Better Systems.

Installation & Operation Manual

Easy installation in both new construction and retrofit

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

- Data Brochure Boiler Control 268

OPERATION & INSTALLATION MANUAL

Proliphix Thermostat Installation Guide. Release 2.0

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Installation & Operation Manual

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

- Data Brochure Boiler Control 274

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Installation & Operation Manual

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Long Range Radio Alarm Transmitter

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

Installation and Operations Manual

Power Pack Service Manual

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

- Data Brochure Snow Detector & Melting Control 665

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

- Essay Control Functions and Benefits

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

FW-RA-LED Remote Multiplex Annunciator Panels

Transcription:

- Data Brochure Programmable Thermostat 510 and 511 D 510 02/12 Table of Contents Display / Keypad Operation... pg 1 Display Symbols... pg 2 General... pg 2-3 Sequence of Operation... pg 4 Installation - Slab Sensor 079... pg 5-7 Installation - Thermostats...pg 8-9 Wiring Examples... pg 9-10 Replaces: 09/09 Menus...pg 11-13 View Menu...pg 11 Adjust Menu...pg 11-13 Error Messages... pg 14 Technical Data... pg 15 Warranty... pg 16 This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only! Display / Keypad Operation The thermostat s display has four distinct fields. These fields are the Menu field, the Item field, the Number field and the Status field. The four buttons on the face of the thermostat are used to navigate through the menus and items to view and / or adjust the desired settings. Displays the current menu Displays an abbreviated name of the selected item Displays the current status of the thermostat's inputs, outputs and operation Displays the current value of the selected item Selects Menus, Items and adjusts settings 1 of 16 2012 D 510-02/12

Display Symbols Warning Displays when an error exists. Access Level Displays when in the user access level. Heat One Displays when the heat contact is on. Early Start Displays when the thermostat is in early start. General CYCLES PER HOUR (HEAT CYCLE) The thermostat operation is based on cycles per hour. The number of cycles per hour is adjustable through the HEAT CYCLE settings in the Adjust menu. During each cycle that heating is required, the thermostat turns on the Heat relay for a calculated amount of time. This amount of time is the on time. The on time is calculated based on the requirements of the zone. If the zone requires more heating, the ON time is increased. If the zone requires less heat, the ON time is reduced. In order to prevent short cycling of the heating relay(s), the thermostat ensures that the relay(s) remains on or off for a minimum amount of time. An Auto Cycle setting is available for the heating cycle. This setting allows the thermostat to determine the best number of cycles per hour that balances both temperature swings and equipment cycles. on off Cycles Per Hour on off on Cycle Length Time off EARLY START ( ) The early start function ensures that the zone is up to the proper temperature at the beginning of each period. The thermostat learns the recovery rate over multiple setback events in order to determine the proper lead time for the zone. If both an air sensor and a slab sensor are used, the lead time is the greater of the air sensor s or the slab sensor s requirements. 70 F (21 C) 62 F (17 C) 70 F (21 C) 62 F (17 C) Early Start OFF Early Start ON UnOccupied Occupied NOTE: The Early Start feature occurs when the schedule changes from a low temperature to a higher temperature. AUXILIARY SENSORS The thermostat has a single built-in sensor to measure air temperature at the thermostat. In addition to the built-in sensor, the thermostat has terminals to connect up to two separate sensors. These sensors can be either indoor sensors, slab sensors, a remote sensor, or an outdoor sensor. 2012 D 510-02/12 2 of 16

Indoor Sensor An indoor sensor is used to measure the air temperature in the zone that the thermostat is controlling. The temperature being read by the indoor sensor is used in the calculations of the on times for the relay in the thermostat. Either one or both of the auxiliary sensor inputs can be configured for indoor sensors. This setting is made through the Adjust menu of the thermostat. If more than one sensor, either the built-in sensor or an auxiliary sensor set as an indoor sensor, is being used to measure the zone temperature, the temperature of the active sensors is averaged and used to calculate the on time of the relay. Slab Sensor A slab sensor is used to measure the slab temperature in the zone that the thermostat is controlling. The temperature being read by the slab sensor is used in the calculations of the on time for the Heat relay and allows the thermostat to operate the slab between the slab minimum and slab maximum settings. If more than one slab sensor is used, the slab temperatures are averaged by the thermostat. Remote Sensor A single remote sensor can be connected to the thermostat. The temperature measured by a remote sensor does not affect the on time of the relay and is only used for display purposes. Outdoor Sensor A single outdoor sensor can be connected to the thermostat. The temperature measured by an outdoor sensor does not affect the on time of the relay and is only used for display purposes. ACCESS LEVELS The tekmar Programmable Thermostat has two access levels. These access levels restrict the number of items available in the menus of the thermostat. The two access levels are User and Installer. This selection is made using the DIP switch located on the circuit board inside the thermostat. The Installer access level allows the installer to adjust all of the settings in the thermostat including those required to match the thermostat to the mechanical system and the devices used. The User access level allows the end user to adjust the time, temperatures and schedules used by the thermostat. 1 R 6 7 Heat 2 C 3 Com No Power 4 S1 5 S2 Made in Canada Meets Class B: Canadian ICES FCC Part 15 Programmable Thermostat 510 One Stage Heat C US Switch Settings: Installer/User 938-01 510 Power: 24 V ± 10% 60 Hz 3 VA Relay: 24 V (ac) 2 A Class 2 Dip Switch 3 of 16 2012 D 510-02/12

Sequence of Operation ONE STAGE HEAT Air Sensor(s) Only Operation When operating with only an air sensor, the on time for the Heat relay is calculated to satisfy the requirements of the air sensor. Slab Sensor Only Operation When operating with only a slab sensor, the on time for the Heat relay is calculated to satisfy the requirements of the slab sensor. The thermostat operates to maintain the slab at the minimum slab temperature setting. NOTE: Operating with only a slab sensor can lead to either overheating or underheating of the space. Air and Slab Sensor Operation When operating with both air and slab sensors, the thermostat calculates an on time for the Heat relay to satisfy the slab sensor s requirements and an on time to satisfy the air sensor s requirements. The Heat relay operates for the longer of these two on times. During light heating loads, overheating can occur due to the minimum slab temperature requirements. During heavy heating loads, the maximum slab temperature setting limits the on time of the Heat relay. In this situation, underheating can occur. Mode Heat In the heat mode, the Heat relay is operated to satisfy the temperature requirement of the zone. Off In the Off mode, the Heat relay is not operated. NOTE: If an air or slab sensor is active in the Off mode, a freeze protection is enabled that allows the Heat relay to be operated to keep the zone above 35 F (2 C). GETTING READY Check the contents of this package. If any of the contents are missing or damaged, please contact your wholesaler or tekmar sales representative for assistance. Type 510 Includes: One Programmable Thermostat 510 Data Brochure D 510 User Brochure U 510 Type 511 Includes: One Programmable Thermostat 510 One Slab Sensor 079 Data Brochure D 510 User Brochure U 510 2012 D 510-02/12 4 of 16

Slab Sensor 079 The tekmar Slab Sensor 079 has a stainless steel sleeve which is designed for use in concrete, thin-set or grout. The 079 is supplied with 10 (3 m) of 2 conductor zipcord. Installation - Slab Sensor 079 STEP ONE New Installations INSTALLING THE SENSOR Thin-Set or Thin-Pour Applications Tiles Thin-set If the floor covering is to be installed over either a thin-set or thin-pour material of sufficient Electric Cables depth, the 079 slab sensor can be placed directly into either the thin-set material or the thin-pour material and covered over. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location. Splices within the thin-set or thin-pour should be avoided to ensure trouble free operation. The sensor should be located mid way between the heating elements to ensure a proper temperature reading. Thin Floor Coverings (less than 3/8 (10 mm)) If a thin floor covering is to be installed directly to the subfloor, a groove 1/8 (4 mm) wide by Hardwood 1/16 (2 mm) deep can be cut into the surface of the subfloor to accommodate the wire for the Subfloor sensor. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location. Splices under the floor covering should be avoided to ensure trouble free operation. A groove 3/16 (5 mm) wide by 3/16 (5 mm) deep by 1-3/4 (45 mm) long should be cut to accommodate the sensor. The sensor should be located mid way between the heating elements to ensure a proper temperature reading. Thick Floor Coverings (greater than 3/8 (10 mm)) If a thick floor covering is to be installed directly to the subfloor, a groove 1/8 (4 mm) wide by 1/16 (2 mm) deep can be cut into the back of the flooring material to accommodate the wire for the sensor. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location. Splices under the floor covering should be avoided to ensure trouble free operation. A groove 3/16 (5 mm) wide by 3/16 (5 mm) deep by 1-3/4 (45 mm) long should be cut to accommodate the sensor. The sensor should be located mid way between the heating elements to ensure a proper temperature reading. Subfloor Hardwood NOTE: If it is not practical to cut a groove in the surface covering, follow the installation method used for thin floor coverings. 5 of 16 2012 D 510-02/12

Retrofit Installations Tile Floor Coverings If a Slab Sensor 079 is to be installed into an existing tile floor with sufficiently large grout lines, the sensor and wire can be installed in one of the grout lines between the tiles. Select a low traffic area of the floor that is mid way between the heating elements for the sensor location. Ensure that the sensor is Tiles located in such a position that the attached wire Thin-set is able to reach to a suitable junction location. Splices within the grout should be avoided to Subfloor ensure trouble free operation. Remove the appropriate grout line and place the sensor and wire in the floor. Re-grout the area. Installing the Sensor to the Bottom of a Subfloor If the sensor is to be installed to the bottom of a subfloor, cut a piece of 1 (25 mm) thick rigid insulation into a 6 (150 mm) by 6 (150 mm) square. A groove 3/16 (5 mm) wide by 3/16 (5 mm) deep by 1-3/4 Subfloor (45 mm) long should be cut into the insulation to accommodate the sensor. Place the sensor in the groove and sandwich the sensor between the insulation and the subfloor. Use a suitable fastening method to affix the insulation to the subfloor. STEP TWO WIRING AND TESTING THE SENSOR Caution: Do not run sensor wires parallel to telephone or power cables. If the sensor wires are located in an area with strong sources of electromagnetic interference, shielded cable or twisted pair should be used or the wires can be run in a grounded metal conduit. The Slab Sensor 079 is supplied with 10 (3 m) of cable. If a longer length is required, 24 AWG or larger wire can be spliced onto the two wires from the sensor. The splices should be properly soldered and protected in an accessible junction box. Follow the sensor testing instructions given in this brochure and then connect the wires to the control. 2012 D 510-02/12 6 of 16

Sensor Testing Instructions Temperature Resistance Temperature Resistance Temperature Resistance Temperature Resistance F C Ω F C Ω F C Ω F C Ω -50-46 490,813 20-7 46,218 90 32 7,334 160 71 1,689-45 -43 405,710 25-4 39,913 95 35 6,532 165 74 1,538-40 -40 336,606 30-1 34,558 100 38 5,828 170 77 1,403-35 -37 280,279 35 2 29,996 105 41 5,210 175 79 1,281-30 -34 234,196 40 4 26,099 110 43 4,665 180 82 1,172-25 -32 196,358 45 7 22,763 115 46 4,184 185 85 1,073-20 -29 165,180 50 10 19,900 120 49 3,760 190 88 983-15 -26 139,402 55 13 17,436 125 52 3,383 195 91 903-10 -23 118,018 60 16 15,311 130 54 3,050 200 93 829-5 -21 100,221 65 18 13,474 135 57 2,754 205 96 763 0-18 85,362 70 21 11,883 140 60 2,490 210 99 703 5-15 72,918 75 24 10,501 145 63 2,255 215 102 648 10-12 62,465 80 27 9,299 150 66 2,045 220 104 598 15-9 53,658 85 29 8,250 155 68 1,857 225 107 553 A good quality test meter capable of measuring up to 5,000 kω (1 kω = 1000Ω) is required to measure the sensor resistance. In addition to this, the actual temperature must be measured with either a good quality digital thermometer, or if a thermometer is not available, a second sensor can be placed alongside the one to be tested and the readings compared. First measure the temperature using the thermometer and then measure the resistance of the sensor at the control. The wires from the sensor must not be connected to the control while the test is performed. Using the chart on the following page, estimate the temperature measured by the sensor. The sensor and thermometer readings should be close. If the test meter reads a very high resistance, there may be a broken wire, a poor wiring connection or a defective sensor. If the resistance is very low, the wiring may be shorted, there may be moisture in the sensor or the sensor may be defective. To test for a defective sensor, measure the resistance directly at the sensor location. Do not apply voltage to a sensor at any time as damage to the sensor may result. 7 of 16 2012 D 510-02/12

Thermostat Installation STEP TWO REMOVING THE FRONT COVER Place a screwdriver or similar object into the small slot located in the top of the thermostat. Push the screwdriver against the plastic tab and pull the top of the front cover so that it pivots around the bottom edge of the base. 2 Remove cover 1 Push tab STEP THREE MOUNTING THE BASE The thermostat should be installed on an interior wall of the desired zone approximately 5 (1.5 m) above the floor. Do not mount the thermostat in a location that may be affected by localized heat sources or cold drafts. It may be necessary to install a draft barrier behind the thermostat to prevent air from blowing through the wiring hole and affecting the thermostat s built-in sensor. Mount the base directly to the wall using two #6 1 screws. The screws are inserted through the mounting holes and must be securely fastened to the wall. If possible, at least one of the screws should enter a wall stud or similar surface. If the thermostat is to be mounted to a 2 x 4 electrical box, order an Adaptor Plate 007. This plate mounts to the electrical box and the thermostat mounts to the plate. Ensure that the electrical box does not provide cold air to the thermostat. Menu Item #6 1 screws NOTE: If the thermostat is to be used for remote sensing (i.e. The built-in air sensor is disabled and an indoor sensor is being used.) Mount the thermostat in the desired location in an appropriate manner. STEP THREE ROUGH IN WIRING 18 AWG or similar wire is recommended for all 24 V (ac) wiring. All wires are to be stripped to 1/4 (6 mm) to ensure proper connection to the control. Run wires from the 24 V (ac) power to the thermostat. Use a clean power source to ensure proper operation. Run wires from the heating device to the thermostat. 2012 D 510-02/12 8 of 16

STEP FOUR WIRING THE THERMOSTAT 24 V (ac) Power (Refer to the examples on the following pages.) 24 V (ac) power Connect the 24 V (ac) power to the R and C terminals (1 and 2) of the thermostat. This connection provides power to the microprocessor and display of the thermostat. Auxiliary Sensors (S1 and S2) Either an indoor, slab, or remote sensor may be connected to the S1 input. Connect the two wires from the auxiliary sensor to the Com and S1 terminals (3 and 4). Either an indoor, slab, or outdoor sensor may be connected to the S2 input. Connect the two wires from the auxiliary sensor to the Com and S2 terminals (3 and 5). Heat Relay The Heat terminals (6 and 7) are an isolated output. There is no power available on these terminals from the thermostat. These terminals are to be used as a switch for a 24 V (ac) circuit. This circuit can operate a low current 24 V (ac) device directly or an external relay to enable a line voltage or high current device. STEP FIVE INSTALLING THE FRONT COVER Align the hinges on the bottom of the front cover with the bottom of the thermostat mounting base. Pivot the front cover around the bottom hinges and push the top against the mounting base until it snaps firmly in place. 2 Pivot front cover around bottom hinges Menu Item 1 Align hinges on bottom of front cover Wiring Examples WIRING 24 V (AC) POWER AND AUXILIARY SENSORS Made in Canada Meets Class B: Canadian ICES FCC Part 15 938-01 510 120 V (ac) 24 V (ac) Sensor Wires Switch Settings: Installer/User Power: 24 V ± 10% 60 Hz 3 VA Relay: 24 V (ac) 2 A Class 2 Auxiliary Sensor (Optional) 9 of 16 2012 D 510-02/12

WIRING THE 510 Wiring to 24 V (ac) Zone Valve Zone Valve M 1 R 6 7 Heat 2 C No Power 3 4 5 Com S1 S2 Made in Canada Meets Class B: Canadian ICES FCC Part 15 Programmable Thermostat 510 One Stage Heat C US Switch Settings: Installer/User 938-01 510 Power: 24 V ± 10% 60 Hz 3 VA Relay: 24 V (ac) 2 A Class 2 24 V (ac) Class 2 Transformer Wiring to Unpowered 24 V (ac) Relay Unpowered Relay 3 4 5 6 2 1 8 7 Zone Pump 1 R 6 7 Heat 2 C No Power 3 4 5 Com S1 S2 Made in Canada Meets Class B: Canadian ICES FCC Part 15 Programmable Thermostat 510 One Stage Heat C US Switch Settings: Installer/User 938-01 510 Power: 24 V ± 10% 60 Hz 3 VA Relay: 24 V (ac) 2 A Class 2 24 V (ac) Class 2 Transformer Wiring to Powered 24 V (ac) Relay Typical Powered Relay Zone Pump 1 2 L N T T 1 R 6 7 Heat 2 C No Power 3 4 5 Com S1 S2 Made in Canada Meets Class B: Canadian ICES FCC Part 15 Programmable Thermostat 510 One Stage Heat C US Switch Settings: Installer/User 938-01 510 Power: 24 V ± 10% 60 Hz 3 VA Relay: 24 V (ac) 2 A Class 2 24 V (ac) Class 2 Transformer 2012 D 510-02/12 10 of 16

View Menu ROOM TARGET The current desired air temperature for the space. This item is only available in the Installer access level. (Must have an active air sensor.) ROOM The current air temperature for the space. (Must have at least one active air sensor. This is the average of all active air sensors.). OUTDOOR The current temperature at the outdoor sensor. (Sens 2 must be set to Out.) SLAB The current slab temperature. (Must have an active slab sensor. If two slab sensors are present, this is the average temperature.) The MIN Setpoint is displayed when running on Min. REMOTE The current temperature at the remote sensor. (Sens 1 must be set to Rem.) Adjust Menu (1 of 3) MODE Current mode of operation of the thermostat. OFF, HEAT ROOM HEAT (No Schedule) Desired temperature for heating. (Must have an active air sensor and be set to Heat.) 35 to 100 F (1.5 to 38.0 C) SLAB MINIMUM (No Schedule) Minimum slab temperature. (Must have an active slab sensor.) OFF, 34 to 122 F (OFF, 1.0 to 50.0 C) 11 of 16 2012 D 510-02/12

Adjust Menu (2 of 3) ROOM HEAT UnOcc Desired temperature for heating during UnOccupied. (Must have an active air sensor and be set to Heat.) 35 to 100 F (1.5 to 38.0 C) ROOM HEAT Occ Desired temperature for heating during Occupied. (Must have an active air sensor and be set to Heat.) 35 to 100 F (1.5 to 38.0 C) ROOM HEAT Sleep Desired temperature for heating during Sleep. (Must have an active air sensor and be set to Heat.) 35 to 100 F (1.5 to 38.0 C) SLAB MINIMUM Wake Minimum slab temperature during Wake. (Must have an active slab sensor.) OFF, 34 to 122 F (OFF, 1.0 to 50.0 C) SLAB MINIMUM UnOcc Minimum slab temperature during UnOccupied. (Must have an active slab sensor.) OFF, 34 to 122 F (OFF, 1.0 to 50.0 C) SLAB MINIMUM Occ Minimum slab temperature during Occupied. (Must have an active slab sensor.) OFF, 34 to 122 F (OFF, 1.0 to 50.0 C) SLAB MINIMUM Sleep Minimum slab temperature during Sleep. (Must have an active slab sensor.) OFF, 34 to 122 F (OFF, 1.0 to 50.0 C) SLAB MAXIMUM Maximum slab temperature. This item is only available in the Installer access level. (Must have an active slab sensor.) 34 to 122 F, OFF (1.0 to 50.0 C, OFF) 2012 D 510-02/12 12 of 16

Adjust Menu (3 of 3) SENSOR 1 Selects the type of auxiliary sensor present in the Sen 1 input. This item is only available in the Installer access level. OFF, Indr, SLAB, REM SENSOR 2 Selects the type of auxiliary sensor present in the Sen 2 input. This item is only available in the Installer access level. OFF, Indr, SLAB, OUT ROOM SENSOR Selects whether the built-in sensor is functional or not. This item is only available in the Installer access level. OFF, ON HEATING CYCLE Determines the number of cycles per hour for the heating equipment. This item is only available in the Installer access level. Auto, 2 to 12 EARLY START Selects whether or not the Early Start feature is active. This item is only available in the Installer access level. OFF, ON LITE Sets the operation of the backlighting of the LCD. ON, Tmpy ON, OFF UNITS The units of temperature used to display the items. F, C 13 of 16 2012 D 510-02/12

Error Messages (1 of 1) E01 The thermostat was unable to read a piece of information stored in its memory. The thermostat was required to load the factory settings. The thermostat will stop operation until all settings are checked. To clear this error, select the Installer access level and check all of the settings in the Adjust and Schedule menus. E02 There are no active sensors selected on the thermostat. Either the internal sensor must be turned on or at least one auxiliary sensor must be set to either INDR or SLAB. After the fault is corrected, press any button to clear the error message. ROOM SHORT The thermostat s internal air sensor is short circuit. This cannot be repaired in the field. The thermostat should be replaced or returned for repair. ROOM OPEN The thermostat s internal air sensor is open circuit. This cannot be repaired in the field. Either turn off the internal sensor and use an auxiliary sensor set to INDR or replace or repair the thermostat. After the fault is corrected, press any button to clear the error message. SENSOR 1 SHORT The auxiliary sensor connected to the Sens 1 terminal is short circuit. Locate and repair the problem as described in the appropriate sensor brochure. After the fault is corrected, press any button to clear the error message. SENSOR 1 OPEN The auxiliary sensor connected to the Sens 1 terminal is open circuit. Locate and repair the problem as described in the appropriate sensor brochure. After the fault is corrected, press any button to clear the error message. SENSOR 2 SHORT The auxiliary sensor connected to the Sens 2 terminal is short circuit. Locate and repair the problem as described in the appropriate sensor brochure. After the fault is corrected, press any button to clear the error message. SENSOR 2 OPEN The auxiliary sensor connected to the Sens 2 terminal is open circuit. Locate and repair the problem as described in the appropriate sensor brochure. After the fault is corrected, press any button to clear the error message. 2012 D 510-02/12 14 of 16

Technical Data Programmable Thermostat 510 and 511 One Stage Heat Literature D510, U510, C510 Control Microprocessor control. This is not a safety (limit) control Packaged weight 0.5 lb. (230 g) Dimensions 2-7/8 H x 2-7/8 W x 13/16 D (73 x 73 x 21 mm) Enclosure White PVC plastic, NEMA type 1 Approvals CSA C US, meets class B: ICES & FCC Part 15 Ambient conditions Indoor use only, 32 to 122 F (0 to 50 C), RH 90% Noncondensing Power supply 24 V (ac) ±10%, 60 Hz, 3 VA Relays 24 V (ac) 2 A max, Class 2 Sensors NTC thermistor, 10 kω @ 77 F (25 C ±0.2 C) ß=3892 Included 510 (None), 511 (079) Optional tekmar type #: 070, 072, 073, 076, 077, 079, 083, 084 Warranty Limited 3 Year (See D510 for full warranty) Slab Sensor 079 Literature D079, C079 Packaged weight 0.1 lb. (50 g), 316 stainless steel, 10 (3 m) 24 AWG, 300 volt PVC insulated Zipcord Dimensions 3/16 OD x 1-1/2 (5 OD x 38 mm) Approvals CSA C US Operating range -58 to 140 F (-50 to 60 C) Sensor NTC thermistor, 10 kω @ 77 F (25 C ±0.2 C) ß=3892 Warranty Limited 3 Year (See D079 for full warranty) Notes 15 of 16 2012 D 510-02/12

Limited Warranty and Product Return Procedure Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product ( Product ), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer s passthrough warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar s instructions, ordinary wear and tear excepted. The passthrough warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser s agreement and warranty with its customers. Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers. The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar s instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar s instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WAR- RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIP- TION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIM- ITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW. Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser s customers, regarding a potential warranty claim, tekmar s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative. All specifications are subject to change without notice tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road Vernon, B.C. Canada V1B 3K4 (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 2012 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 16 of 16 D 510-02/12