230v Dial Thermostat Instruction Manual

Similar documents
Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Wireless Thermostats 230v and Battery Operated Quick Set-up Guide

4 in 1 Digital Thermostat Control

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Digital Thermostat Models: VS30W and VS30B

ET10 Series Stand-alone LCD Fan Coil Thermostat

Model: RT510RF. Installation Manual

Electronic Thermostat With RF

Room thermostat with 24-hour time switch and large LCD

Room thermostat with Auto Timer, independent DHW

ETAF Series VDC Fan output LCD Fan Coil Thermostat

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: RT310. Installation Manual

Model: RT310RF. Installation Manual

Room thermostat with Auto Timer, Option External Input

Contents.

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, Option External Input

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Wireless room thermostat with LCD

Room thermostats with LCD RDD100..

Room Temperature Controllers

Drayton Digistat +3RF

Pre-programmed room controller with communication

Room thermostat with Auto Timer, Option External Input

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

RF Programmable Room Thermostat Installation Instructions

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Pre-programmed room controller with communication and hidden setpoint

RC-2000 Thermostat Installation Instructions

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

HAI Omni-Bus Network Installation. 5. Typical Application

Pre-programmed room controller with communication

Simple. Smart. Solutions.

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Room Temperature Controller

Model: Touch-RF. 1 Wireless Series

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

ELECTRONIC COMMUNICATING THERMOSTAT

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Flush-mounted room thermostat

Digital Electronic Thermostat With RF

DOL 31 Speed Controller Technical User Guide

Room thermostat with independent DHW control

Digital Room Thermostat

Digital Electronic Thermostat With RF

Installation, Operating and Maintenance Manual

Control solutions Biofloor

GreenCon On/Off Room Thermostat

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Model: Slimline-RF. 1 Slimline Series

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Declaration of Conformity no. 56/2012

Use. For 2-pipe fan coils

COMPUTHERM Q4Z zone controller (for controlling 1 to 4 heating zones) Operating Instructions

evotouch Controller Installation evotouch

Room controllers with manual forced ventilation function

Simple. Smart. Solutions.

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

OJ Waterline control system

aura-t TP536/GBR ventilation systems

Programmable Room Thermostat Installation Instructions

Electronic Dual Cylinder Thermostat Installation Instructions

INSTALLATION & USER MANUAL

T6590 Series FAN-COIL CONTROLLER

RVL479. Heating Controller. for use with a partner unit

Heat Link. Technical Guide

RVL481. Heating Controller. including d.h.w. heating

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Underfloor Catalogue Heating products that define the market

Wall-mounted room thermostat with LCD

QAW70. Room Unit. Building Technologies. for use with heating controllers

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

ETN-24-SUPER-PROG (US Program - Celsius)

RCS Residential Control Systems Inc.

VR 90 Remote control unit

: PRT / PRT PRT / PRT-N1

RVL480. Heating Controller

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Room Temperature Controller

MC 31 Speed Controller Technical User Guide Code no GB

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

GreenCon On/Off Room Thermostat

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Battery Powered Electronic Room Thermostat Cat. No. TRT033

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

INSTALLATION & OPERATION MANUAL

Transcription:

230v Dial Thermostat Instruction Manual

Contents Box contents: 230v Dial Thermostat Instruction Manual Instruction Manual Fixing screws JGSTAT1 Instruction manual: Box contents Introduction Product compliance Safety information Mounting position and installation System grouping and communication User interface LED indication Icons used in this manual: Safety Important info Your benefit For latest PDF Instruction Manual please go to speedfitufh.co.uk 02 JGSTAT1 Instruction Manual

Product Compliance & Safety Information Introduction. Thank you for purchasing the Speedfit Aura Dial Thermostat JGSTAT1. This is a 230v Dial Thermostat which offers simple temperature control of your heating system. Speedfit recommends that you use your JGSTAT1 with the Aura JGWC Wiring Centre and JGSTAT2 Digital Room Thermostat. The JGSTAT2 can be used as a group control thermostat to control groups of STAT1s. Please see pages 6 and 7. Product Compliance. This product is CE compliant and meets the following Directives: EMC 2014/30/EU, LVD 2014/35/EU and RoHS 2011/65/EU. Declaration of conformity available at saluslegal.com Safety Information. Use in accordance with the regulations. The Aura JGSTAT1 is to be used for room control of hot water heating systems inside buildings. Installation. This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the location where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. Always isolate the AC mains supply before installing or working on any components that require 230v AC 50Hz supply. We hope you enjoy this product... speedfitufh.co.uk 03

Product Compliance & Safety Information These instructions are applicable to the Speedfit Aura model stated on the front cover of this Instruction Manual only. Sources of danger. The thermostat must be disconnected from mains supply before removing the cover. Installer parameter settings. The Aura JGSTAT1 is equipped with Installer Parameters (see page 13). Emergency. Switch off the voltage to the individual thermostat wiring centre or complete system. For the installer. Please enter any parameter changes in the Installer Notes section. 230v AC 04 JGSTAT1 Instruction Manual

130cm Installation - Thermostat Mounting Mounting position and installation. To ensure trouble free operation and efficient control, the unit is best positioned in a draft free area and at 130cm from the floor. Do not position the thermostat near any heat source, behind curtains, direct sunlight or an area of high humidity. INSTALLATION Not to be positioned on an exterior wall. speedfitufh.co.uk 05

System Overview - Grouping and Communication Power and Switching Cable - used to power thermostats and drive output. Grouping and Communication cable. While the thermostats can function as standalone, installing this optional inexpensive communication cable allows the thermostats to communicate with the Aura JGSTAT2 configured as a group control thermostat and used with the Aura JGWC Wiring Centre (both sold separately). The JGSTAT1 will follow instructions from the JGSTAT2 bringing central control of features such as Time Control, Holiday and Party functions as well as Frost Control. The JGSTAT1 can leave or re-enter group control at the slide of a switch. JGSTAT2 Group Control Thermostat (sold separately). 06 JGSTAT1 Instruction Manual

System Overview - Grouping and Communication The maximum number of groups per JGWC Wiring Centre is two. The group selection communication cable must correspond to the group terminals on the JGWC. Please refer to the JGWC Wiring Centre Instruction Manual. INSTALLATION Group 1 For example, downstairs Group 2 For example, upstairs Aura JGWC Wiring Centre speedfitufh.co.uk 07

Installation - Thermostat Mounting 1 2 Carefully remove the front housing. 3 Wall Mounting. For wall mounting, mark and mount the rear case to the wall. The JGSTAT1 is suitable for wall boxes with a centre hole distance of: 60mm 08 JGSTAT1 Instruction Manual

Installation - Terminal Connections Understanding your terminal connections. Rear of unit 1 Communication Terminals 12v DC. Two wire twisted pair can be used for grouping functions between JGSTAT2 and JGSTAT1. Also required for Heat/Cool changeover. INSTALLATION 2 Sensor Terminals. Can be used for external Air or Floor sensor. 1 2 3 3 Power Terminals 230v AC. Used for supplying power to the unit and switched output. speedfitufh.co.uk 09

SL N L ZONE 1 SL N L ZONE 2 SL N L ZONE 3 SL N L ZONE 4 SL N L ZONE 5 SL N L ZONE 6 SL N L SL N L ZONE 7 ZONE 8 5 x 20mm 5 x 20mm Installation - Thermostat Connections Optional communication connection 12v DC While the JGSTAT1 can function on its own, installing this optional, inexpensive communication cable allows the JGSTAT1 to communicate with the Aura JGSTAT2 (sold separately). For more detail refer to the Wiring Centre Instruction Manual. 10 JGSTAT1 Instruction Manual

Installation - Terminal Connections 1 2 3 Check that the wiring is completed for: Power terminals. Sensor terminals (if applicable). Communication connections (optional but recommended). INSTALLATION You are ready to secure the rear housing to the wall box. Please use the screws provided. Ensure the orientation arrow is pointing upwards. speedfitufh.co.uk 11

Installation - Thermostat Mounting 2 3 1 4 1 2 If any parameter settings need to be changed please refer to next page. Fit the front housing to the rear housing as shown above. 12 JGSTAT1 Instruction Manual

Installation - Parameter Setting 1 External sensor (optional) If you are fitting an external sensor for air/floor sensing please select temp here. It can be set from 0ºC - 45ºC and is preset at 27ºC. Please note the dip switches 2 need to be set for the correct external sensor type, see below. 2 INSTALLATION FUNCTION DESCRIPTION DEFAULT Valve Exercising PWM External sensor type Actuator type Reduced temp offset / Night setback If the installer setting is to enable the valve exercising the dial thermostat will additionally send 5 minute pulse on actuator once a week. PWM output to drive actuator open/close (prevents temperature overshoot). Air or floor. Normally Closed or Normally Open. JG Actuators are supplied ready for the default NC setting 0, 4, 6 or 8 (only when used with JGSTAT2 and JGWC). ENABLE ON AIR NC 4ºC speedfitufh.co.uk 13

User Interface LED Indication Temperature Adjustment 5ºC - 30ºC Mode Selection The JGSTAT1 is no longer a member of the group and will ignore commands from the JGSTAT2 Group Control Thermostat. The JGSTAT1 is a group member and will follow commands from the JGSTAT2 Group Control Thermostat. The JGSTAT1 leaves the group, Frost protection of 5ºC is active. 14 JGSTAT1 Instruction Manual

LED Indication - Group Member Slide switch must be in position to follow Group Control Thermostat JGSTAT2, see page 14. RED LED indicates that power is going to the thermostat in normal operation. The top LED will illuminate when room temperature falls below your required temperature. Green LED means that the thermostat is calling for heat. The Group Control Thermostat will be in one of the following modes: 1. 2. 3. JGSTAT2 Group Control Thermostat display. For more details on JGSTAT2 please refer to JGSTAT2 Instruction Manual. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select or. See previous page. USER GUIDE speedfitufh.co.uk 15

LED Indication - Group Member Slide switch must be in position to follow Group Control Thermostat JGSTAT2, see page 14. To reduce annoyance factor, no LED is shown when the Group Control Thermostat is in reduced temperature/night setback mode. See below. To adjust reduced temperature offset please refer to page 13. JGSTAT2 Group Control Thermostat display. Amber LED means that the thermostat is calling for heat in reduced/night setback mode. The Group Control Thermostat will be in one of the following modes: 1. For more details on JGSTAT2 2. please refer to JGSTAT2 Instruction Manual. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select or. See page 14. 16 JGSTAT1 Instruction Manual

LED Indication - Group Member Slide switch must be in position to follow Group Control Thermostat JGSTAT2, see page 14. Blue LED indicates the thermostat is in Frost Protection Mode. Frost Protection temperature is fixed at 5ºC. USER GUIDE JGSTAT2 Group Control Thermostat display. Green LED means that the temperature has fallen below the frost protection level and the thermostat is calling for heat. The Group Control Thermostat will be in one of the following modes: 1. 2. If you do not want a JGSTAT1 to follow the Group Control Thermostat JGSTAT2. Please select or. See page 14. For more details on JGSTAT2 please refer to JGSTAT2 Instruction Manual. speedfitufh.co.uk 17

LED Indication - Manual Mode To enter Manual Mode, slide the switch to the position. The thermostat will not follow the Group Control Thermostat JGSTAT2 and will no longer be part of the group. The JGSTAT1 will work as a stand alone thermostat. RED Led indicates that power is going to the unit in normal operation. The top LED will illuminate when room temperature falls below your required temp. Green LED means that the unit is calling for heat. To return the JGSTAT1 to the group (if applicable) move the slide switch to 18 JGSTAT1 Instruction Manual

LED Indication - Permanent Frost Mode To enter Manual Mode, slide the switch to the position. The thermostat will not follow the group control thermostat JGSTAT2 and will no longer be part of the group. The JGSTAT1 will be in permanent Frost Protection. Blue LED indicates the thermostat is in frost protection mode. Frost protection temperature is fixed at 5ºC. USER GUIDE Green LED indicates the temperature has fallen below the Frost protection level and the thermostat is calling for heat. To return the JGSTAT1 to the group (if applicable) move the slide switch to speedfitufh.co.uk 19

Installation - Technical Detail MODEL TYPE TEMPERATURE Scale Tolerance Set Temperature range Frost Protection CONTROL ENVIRONMENT RATINGS Operating Temperature Storage Temperature Operating Humidity (non condensed) POWER SOURCE CONTROL SWITCH AND RATING Loading Input JGSTAT1 Wired Dial Thermostat designed for 230v AC heating/cooling applications Celsius 0.5ºC 5ºC - 30ºC 5ºC ON-OFF control / PWM control 0ºC to + 50ºC -20ºC to + 60ºC 5-95%RH 230v AC 50Hz Maximum 3A at SL terminal Comm Connection 12v DC 20 JGSTAT1 Instruction Manual

Installer Notes speedfitufh.co.uk 21

Installer Notes 22 JGSTAT1 Instruction Manual

Installer Notes speedfitufh.co.uk 23

John Guest Speedfit Limited Horton Road, West Drayton, Middlesex UB7 8JL, England. Tel: 01895 449233 Fax: 01895 420321 speedfitufh.co.uk Technical Help Desk: 01895 425333, and The above namestyles are all trademarks of John Guest International Limited. John Guest International Limited 2017. All rights reserved. Z2105/423/0117