OIL FREE CENTRIFUGAL CHILLER

Similar documents
MODULAR CHILLER. R410a R22

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

MODELS LIST. Nominal Capacity RT

MTW Series Modular Oil Free Centrifugal Chillers

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

DAIKIN Modular Inverter Air Cooled Chiller

Midea VFD Centrifugal Chiller Technology

Air Cooled Scroll Chiller

Product Line Introduction. Karl Zhang Technical support engineer

Magnetic Bearing Technology: Achievements in Higher Efficiency

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Innovation for a Better & Greener Future

DAIKIN Huizhou Factory Profile

3 0 H X C A - H P 2

Water-cooled Centrifugal Chiller

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

DC Inverter Smart VRF Products(R410A)

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Modular Water Cooled Water Chiller

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

Smardt Oil-Free Chillers

Air cooled industrial chillers

PRODUCT GUIDE

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

KELVIN Clim F497. Kelvin air conditioning

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Presented By: John Dolan, P.E.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Leadership, Innovation, Advanced Technology Synergise Here!

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Air Cooled Scroll Chiller

Commercial Air Conditioners 2017/2018

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

kw. technicalcatalogue

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

AHU Plus. DX Air Handling Units

DC inverter VRF presentation

HVAC Water chiller selection and optimisation of operation

Hitachi Centrifugal Chillers

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Chapter-8 Capacity Control of Refrigeration Systems

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

ECO-ANT21 Corporation

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

High COP. Water-Cooled Screw Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

INSTALLATION AND USER MANUAL

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Cutting Edge Compressor Technology

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

MAC-A R410A Series Air cooled Modular Chiller

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Ultimate energy saving technology

$42,000. Danfoss Turbocor Compressors Give INTERTECH PLASTICS A RESHORING ADVANTAGE. saved annually

30HXC Nominal cooling capacity kw

WATE R -C OOLE D WATE R C H ILLE R S

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

Water-cooled chillers with High Speed Centrifugal Compressors

Vicot Air Conditioning Co., Ltd. CONTENT

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

CNC type Solar Air Conditioner

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

CHAPTER 6 CONDENSING UNITS

EN aquatech.piovan.com

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

ERACS.C-N Higher efficiency air-cooled screw pump

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

Hot Water Heating Systems

Transcription:

OIL FREE CENTRIFUGL CHILLER

OIL FREE CENTRIFUGL CHILLER High Efficiency Energy saving and high efficiency The unit adopts the turbo inverter compressor technology and frictionless technology, which will enhance the energy efficiency greatly. Water cooled series IPLV(integrated part-load value HRI standards) can be 11.98(ir-cooled series IPLV is 6.0). Comparing with normal centrifugal chiller, Haier centrifugal IPLV is 50% higher. Conventional chiller Save cost 40%~50% Tasaki Chiller Comparing with normal centrifugal chiller, Haier centrifugal chiller can save cost up to 40%~50%. bout 1~15 years normal chiller need changing unit Tasaki oil free centrifugal chiller bout 3~4 years Tasaki oil free chiller can take back the initial investment Norma l chiller 3~4 years 1~15 years 5 years bout 3~4 years Tasaki oil free chiller can take back the initial investment. 01OIL FREE CENTRIFUGL CHILLER

a High efficient refrigeration cycle system design High efficient environment friendly refrigerant R134a H F C - 1 3 4 a High efficient Compressor Designed for HFC-134a Oil free DC conversion synchronous motor Twin-stage centrifugal Electronic expansion valve It will control the liquid refrigerant spraying into the evaporator precisely control the compressor, evaporator and condenser running at the optimum efficiency High efficient flooded evaporators High efficience heat transfer, convenient maintenance Turbocor compressor technology The chillers either water-cooled or air-cooled, are designed to optimize the performance of the high efficient danfoss turbocor oil-free centrifugal compressor technology. Inverter speed control Synchronous brushless DC motor Twin-stage centrifugal compressor Pressure and temperature sensors Permanent-magnet motor and Landing bearing The compressor motor is magnetic permanently, which is supplied voltage by PWM (pulse width management) to realize variable speed running. The landing bearing will go upward before the unit starts up, which will keep a certain distance automatically and ensure no friction. The radial bearing is to bear the axis after the compressor is powered down, to avoid the touch between the axis and the other metal surface. HFC-134 Motor and bearing control Inlet guide vanes Magnetic bearing technology Magnetic bearing and orientation sensor: Two radial bearings and one axial bearing compose the digital magnetic bearing system. The movement parts are made of permanent magnet and electric magnet will suspend on the magnet and move without friction. The orientation sensor will confirm the precise position of the rotor at max. 6,000,000 times per minute. Front radial bearing Motor Back radial bearing Rotor Balde Sensor loop Sensor loop Push bearing 0

OIL FREE CENTRIFUGL CHILLER High Efficiency Frictionless system The movement parts of magnetic bearing system centrifugal compressor are composed of two radial magnetic bearings and one axial magnetic bearing. so the digital magnetic bearing system will be suspended when compressor is running. the movement parts do not need oil, which avoid that oil film in the heat exchanger lays on the pipe to reduce the heat exchanging efficiency. thus it will ensure the product has the consistent excellent performance in its operation period. The oil content of old type chiller is 9% on average, which will reduce the efficiency up to 15% to 0%. Tasaki's magnetic bearing system inverter centrifugal chiller can enhance efficiency over 15% because of oil-free lubrication system. EEV (electronic expansion valve) dopt electronic expansion valve. It will control the volume of liquid refrigerant spraying into the evaporator precisely. dopt the special electronic expansion valve driving module, which will control the stepping motor operation due to the different load, adjust valve open angle, control refrigerant flow volume, and control the compressor, evaporator and condenser running at the optimum efficiency. Capacity loss 13 1 11 10 9 8 7 6 5 4 3 1 1 3 4 5 6 7 Oleaginousness 8 Inverter driving The inverter centrifugal compressor adopts the integrated driving module. on the condition of condensing temperature decreasing or load reducing, lower the compressor revolution, then optimum the compressor energy efficiency with 5%~100% of rated load. Optional: digital load balancing valve, compressor even can work normally even when the load almost closes to 0. High efficiency heat exchange tube design technology The new design adopt high efficiency heat exchange tube. The tube adopt special layout make refrigerant flow improvement in the evaporator. Tube external (Refrigerant) Tube Inside (cold water) Low-pressure low-tem perature e gas First i mpeller Second impeller Section - Cold Tube 03

HRI certificate ll models are qualified for HRI certificate, so the products and EER are guaranteed. Compressor safe operation Compressor control module will supply the performance curves and according to the curves, adjust the running speed in time to ensure the compressor running safely. Operalional Envelope CERTIFIED www.ahridirectory.org R SDT 70 60 50 40 Minimum Operalional Capacity Maximum Operalional Capacity 30 0 10 0 50 100 00 50 300 350 Capacity High Reliability Long life Compressor is made from the aerial class aluminum mold and the high strength thermal plastic electronic case, which can keep the compressor long-time and high efficient running. erospace materials and technology, ensure 5 years reliable efficient operation. Safety operation In the case of a power outage, the compressor is fully protected. Motor becomes a generator and charge capacitors There is 60 seconds of power reserved in capacitors Touchdown bearings are used as a back up bearing system for catastrophic failure The moving parts adopt aviation alloy material, which ensure unit reliability and the life above 5 years. 5+ YERS Comfort Flexible adjustment When condensing temperature goes down or the heat load is decrease, the compressor speed will reduce, the system control the refrigerant output from %~100% of the rated load freely, optimize the compressor energy. eroengine turbine design technology. 60 50 40 SDT 30 0 10 0 0 50 100 00 50 300 Capacity erospace equipment Intelligent multilevel reliability control which ensure unit can automatic processing the problems in the operation in any case, such as the case of pow failune etc... Silence and less vibration, more comfortable Fully frictionless operation, The device vibration is close to 0. Low running noise. Lower than *70dB(), while the normal chiller's is higher than 85dB(). Haier chiller doesn't need the anti-vibration parts. *For water-cooled model [air-cooled model is 75dB()] 04

OIL FREE CENTRIFUGL CHILLER Low Cost Low installation and maintenance costs Low start current Because the bearing adopt magnetic bearing system technology, when the system start up, only current is necessary to suspend the axis, low starting torque, which results in low interference for electricity net. Only start current for single compressor unit. The normal chiller start current can reach 0. Because the unit adopt Low start current, the installed don't need soft starter which will save US 80,000 costs. Convenience dvanced control system and convenient operation Big LCD touch screen. Chinese and English are selectable Calendar Fault inquires Water system equipment interlocking Remote control Unit operation parameters quick inquiry 0 Normal chiller start Normal chiller soft start 500 Maglev start High applicability and low installation costs The unit adpots 380V power supply, then 10KV power supply is not required. It will be much safer since the examination and approval process are not required either. Haier chiller adopt 380V power supply without approval procedure Ordinary screw adopt 10 power supply need more approval procedures Without approval procedure More approval procedures Safety Electricity Risk of Electric High-voltage Dangerous VS Restricted reas (staff only) Oil-free system, low maintenance costs The unit adopts no oil in the chiller means no oil contamination over time, so design efficiency is maintained effortlessly. This design can save as much as US 60,000 maintenance costs during the life cycle. Conventional Chiller Tasaki Chiller US 60,000 BMS function The unit can realize BMS function; meanwhile, remote control function can be combined with interlock function and timer running function, to realize non-person control. 05

Easy Installation Easy to transport Because the modular oil free centrifugal chiller is compact,so it easy to transport by the elevator. The normal oil free chiller Equipment Principle Twin-stage compression The high temperature and high pressure refrigerant will be discharged from the compressor (No.4), and enter the condenser, releasing the heat energy to the cooling water in pipe, then change into the med temperature and high pressure gas (No.5). after passing by the throttle valve, refrigerant turns into the low temperature and low pressure gas. next it enters the evaporator, turning into gas with low temperature and low pressure (No.1) by absorbing the energy from the chilled water (1/7 C) flowing by the pipe in evaporator. after that the gas will be compressed in compressor to turn to high temperature and high pressure liquid and be discharged again. Pressure 5 6 3 1 4 nd comperssion Enthalpy The modular oil free chiller Transport by the elevator System control principle The unit will count the air return overheat state due to the air return temperature, then send signal to the control module. the control module will send directly to the centrifugal compressor and the electronic expansion valve. so the centrifugal compressor will adjust the revolution rate, and the electronic expansion valve will adjust the flowing volume. the load control can be adjusted at random, saving energy greatly. 06

07

OIL FREE CENTRIFUGL CHILLER *Picture is based on single compressor model Model CC0350PNI CC0440PNI CC0700PNI CC0790PNI CC0880PNI Combination B * +B *B 350 440 700 790 880 Total KW 10 15 03 6 46.5 EER KW/ 3.43 3.5 3.45 3.5 3.57 Starting current(compressor) Max. running current 50 80 500 530 560 Max. power KW 148 166 96 314 33 supply Ph/V/Hz 3N/380V/50Hz Refrigerant throttle type Electronic expansion valve Capacity control 5%~100% Safe protection compressor overload protection, safe protection, low water flow protection, antifreezing protection,fan motor overload protection,lack of phase protection Magnetic bearing compressor Compressor Quantity 1 1 Refrigerant Charge 0 55 R134a 440 475 510 ir side heat exchanger Fan typ Fan quantity 6 High efficiency copper tube+hydroponic alunminum foil xial fan with low noise 8 1 14 16 Flood type Rated water flow m³/h 60 76 10 136 151 Water side heat exchanger m. C/ 0.017 1 85 88 86 89 90 Unit length 4060 560 7690 8890 10090 External dimension Unit width 00 00 00 00 00 Unit height 70 700 700 700 700 Net weight 3400 3985 6840 745 8010 Weight Gross weight 3450 4050 6940 7540 8140 Operation weight 3500 430 7080 7810 8540 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Operating ambient temperature range 15~43 ; 4. Except CC0350PNI/CC0440PNI model,other models are combination,also separately transport; 5. Due to our policy of innovation some specifications maybe changed without notification;" 08

OIL FREE CENTRIFUGL CHILLER *Picture is based on single compressor model Model CC1050PNI CC1140PNI CC130PNI CC130PNI Combination 3* *+B +*B 3*B 1050 1140 130 130 Total KW 303 35.5 348.5 364.6 EER KW/ 3.47 3.5 3.53 3.6 Starting current(compressor) Max. running current 750 780 810 840 Max. power KW 444 46 480 498 supply Ph/V/Hz 3N/380V/50Hz Refrigerant throttle type Electronic expansion valve Capacity control 5%~100% Safe protection compressor overload protection, safe protection, low water flow protection, antifreezing protection,fan motor overload protection,lack of phase protection Magnetic bearing compressor Compressor Quantity 3 3 3 3 Refrigerant Charge 660 695 R134a 730 765 ir side heat exchanger Fan typ Fan quantity 18 High efficiency copper tube+hydroponic alunminum foil xial fan with low noise 0 4 Flood type Rated water flow m³/h 181 196 1 7 Water side heat exchanger m. C/ 50 50 0.017 50 50 1 40 4 43 45 Unit length 1130 1370 1490 External dimension Unit width 00 00 00 00 Unit height 700 700 700 700 Net weight 1080 10865 11450 1035 Weight Gross weight 10430 11030 11630 130 Operation weight 10660 11390 110 1850 09 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Operating ambient temperature range 15~43 ; 4. Except CC0350PNI/CC0440PNI model,other models are combination,also separately transport; 5. Due to our policy of innovation some specifications maybe changed without notification;"

*Picture is based on single compressor model Model CCPNI CC1490PNI CC1580PNI CC1670PNI CC1760PNI Combination 4 3*+B *+*B +3*B 4B 1490 1580 1670 1760 Total KW 400 43.8 445 46.6 48. EER KW/ 3.5 3.5 3.55 3.61 3.65 Starting current(compressor) Max. running current 1000 1030 1060 1090 110 Max. power KW 59 610 68 646 664 supply Refrigerant throttle type Capacity control Ph/V/Hz 3N/380V/50Hz Electronic expansion valve 5%~100% Safe protection compressor overload protection, safe protection, low water flow protection, antifreezing protection,fan motor overload protection,lack of phase protection Magnetic bearing compressor Compressor Quantity 4 4 4 4 4 Refrigerant Charge 880 915 R134a 950 985 100 ir side heat exchanger Fan typ Fan quantity 4 High efficiency copper tube+hydroponic alunminum foil xial fan with low noise 6 8 30 3 Flood type Rated water flow m³/h 41 56 7 87 303 Water side heat exchanger m. C/ 50 50 50 0.017 50 50 1 75 78 80 86 90 Unit length 14950 16 17350 18550 19750 External dimension Unit width 00 00 00 00 00 Unit height 700 700 700 700 700 Net weight 13800 14385 14970 15555 16140 Weight Gross weight 0 14600 0 15800 16400 Operation weight 14300 30 15760 16490 170 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Operating ambient temperature range 15~43 ; 4. Except CC0350PNI/CC0440PNI model,other models are combination,also separately transport; 5. Due to our policy of innovation some specifications maybe changed without notification;" 10

OIL FREE CENTRIFUGL CHILLER Unit Dimension Diagram ir cooled oil free centrifugal chiller dimension diagram 30 M 460 L N-foundation bolt 300 hoisting protection device(30) evaporator water outlet evaporator water inlet F1 D1 B G1 G G3 300 300 G4 G5 G6 300 H W N1-hoisting hole Model hoisting foundation dimension installation dimension pipe connection dimension hole number bolt number L W H B G1 G G3 G4 G5 G6 D1 F1 M N1 N CC0700PNI 7690 00 700 138 0 0 0 0 60 304 350 8 1 CC0790PNI 8890 00 700 138 0 0 60 304 350 8 14 CC0880PNI 10090 00 700 138 60 304 350 8 16 11

Unit Dimension Diagram ir cooled oil free centrifugal chiller dimension diagram M1 evaporator water outlet 30 30 30 evaporator water inlet M 460 L N-foundation bolt 300 G1 G G3 300 300 G4 G5 G6 300 300 G7 G8 G9 300 300 G10 G11 G1 300 hoisting protection device(30) H evaporator water inlet/outlet F1 B W dimension installation dimension pipe connection dimension hoisting foundation hole number bolt number Model L W H B G1 G G3 G4 G5 G6 G7 G8 G9 G10 G11 G1 F1 M1 M e N1 N CC1050PNI 1130 00 700 138 0 0 0 0 0 0 46 885 375 50 1 18 CC1140PNI 00 700 138 0 0 0 0 46 885 375 50 1 0 CC130PNI CC130PNI CCPNI 1370 1490 14950 00 00 00 700 700 700 138 138 138 0 0 0 0 0 0 0 0 0 0 46 46 46 885 885 885 375 375 375 50 50 50 1 1 16 4 4 CC1490PNI 16 00 700 138 0 0 0 0 0 0 46 885 375 50 16 6 CC1580PNI 17350 00 700 138 0 0 0 0 46 885 375 50 16 8 CC1670PNI 18550 00 700 138 0 0 46 885 375 50 16 30 CC1760PNI 19750 00 700 138 46 885 375 50 16 3 1

OIL FREE CENTRIFUGL CHILLER The Unit Installation Foundation Drawing ir-cooled oil free centrifugal chiller installed base 538 00 B1 Square hole m-100 100 400 G1 G G3 G4 G5 G6 G7 G8 G9 G10 G11 G1 G13 G14 G15 400 Square hole100 100 The chiller stent M0 bolt 400 300 ±0.00 Nut Check washer Rubber shock pad Reserved square hole diagram Model B1() G1() G() G3() G4() G5() G6() G7() G8() G9() G10() G11() G1() G13() G14() G15() m CC0350PNI 138 CC0440PNI 138 CC0700PNI 138 CC0790PNI 138 CC0880PNI 138 CC1050PNI 138 CC1140PNI 138 CC130PNI 138 CC130PNI 138 CCPNI 138 0 0 630 0 0 630 0 0 630 0 0 4 CC1490PNI 138 CC1580PNI 138 CC1670PNI 138 CC1760PNI 138 0 0 6 8 0 0 630 0 0 1 0 0 630 14 630 16 0 0 630 0 0 630 0 0 18 0 0 630 0 0 630 0 0 0 630 630 630 630 4 0 0 630 0 0 630 0 0 630 6 0 0 630 0 0 630 630 8 0 0 630 630 630 30 630 630 630 3 Installation Space Diagram ir-cooled oil free centrifugal chiller installation space diagram Model B C D E CC0350~0440PNI 000 000 0 000 0 CC0700~1760PNI 3000 000 0 000 0 Note: above data is minimum dimension 13

mbient temperature ( C) Chilled water oulet temp. ( C) 5 7 9 10 11 1 13 15 0.91 0.91 0.9 0.91 0.90 0.88 0.87 0.87 0.55 0.5 0.48 0.45 0.4 0.40 0.38 0.33 0.96 0.99 1.01 1.0 1.03 1.04 1.03 0.68 0.67 0.63 0.61 0.59 0.57 0.55 0.5 1.01 1.08 1.10 1.13 1.14 1.16 1.19 0.8 0.84 0.83 0.83 0.83 0.83 0.8 0.80 1.00 1.08 1.10 1.13 1.16 1.18 1.3 0.87 0.90 0.90 0.90 0.91 0.91 0.91 1.01 0.96 1.03 1.10 1.13 1.16 1.19 1. 1.6 0.93 1.01 1.03 1.07 0.93 1.00 1.04 1.07 1.11 1.15 1.19 1.0 1.00 0.9 1.00 1.01 1.03 1.07 1.09 1.14 1.03 Performance Table ir-cooled oil free centrifugal chiller performace table 14 18 3 6 38 35 30 14

WTER-COOLED OIL FREE CENTRIFUGL CHILLER *Picture is based on double compressor model MODEL EER Starting current Max. running current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Charge Water inlet/outlet temp Evaporator Rated water flow Water inlet/outlet temp Condenser Rated water flow Unit length External Unit width dimension Unit height Unit length Package Unit width dimension Unit height Net weight Weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) CC0440PWNI 15 440 74.7 5.89 178 High/low pressure protection, safety protection, low water flow protection, antifreezing protection, compressor overload, lack of phase protection 1 180 76 75 89 70 495 1170 100 550 1435 00 370 410 670 CC0530PWNI 58 87.9 6.01 180 Magnetic bearing compressor Soft start 1 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a 00 Flood type 1 C/7 C 91 0.0176 1.0 73 Shell &Tube heat exchanger 30 C/35 C 106 0.044 1.0 68 495 1170 100 550 1435 00 480 50 830 CC0880PWNI 50 879 146.5 6.00 356 360 00 151 68 00 176 65 4385 1170 100 4450 1435 00 3800 3850 4300 15 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Except above standard models, haier also can be customized products according to customers' requirements ; 4. Due to our policy of innovation some specifications maybe changed without notification;" 5. Model CC1330PWNI~CC810PWNI is split type chiller, the installer need to combine the chiller on site;

*Picture is based on double compressor model MODEL EER Starting current Max. running current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Charge Water inlet/outlet temp Evaporator Rated water flow Water inlet/outlet temp Condenser Rated water flow Unit length External Unit width dimension Unit height Unit length Package Unit width dimension Unit height Net weight Weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) CC1100PWNI 300 1055 174.7 6.04 360 CC1330PWNI High/low pressure protection, safety protection, low water flow protection, antifreezing protection, compressor overload, lack of phase protection 400 00 189 70 00 1 65 4385 1170 100 4450 1435 00 4190 4190 4740 375 1319 17.6 6.06 534 Magnetic bearing compressor Soft start 3 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a 540 Flood type 1 C/7 C 50 7 0.0176 1.0 33 Shell &Tube heat exchanger 30 C/35 C 50 64 0.044 1.0 30 4780 0 100 5000 600 00 6130 600 6880 CCPWNI 400 1407 30.7 6.10 534 3 560 50 4 30 50 8 30 4780 0 100 5000 600 00 6430 6500 730 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Except above standard models, haier also can be customized products according to customers' requirements ; 4. Due to our policy of innovation some specifications maybe changed without notification;" 5. Model CC1330PWNI~CC810PWNI is split type chiller, the installer need to combine the chiller on site; 16

WTER-COOLED OIL FREE CENTRIFUGL CHILLER *Picture is based on double compressor model MODEL EER Starting current Max. running current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Charge Water inlet/outlet temp Evaporator Rated water flow Water inlet/outlet temp Condenser Rated water flow Unit length External Unit width dimension Unit height Unit length Package Unit width dimension Unit height Net weight Weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) CC1580PWNI 450 1583 59.5 6.10 540 CC1760PWNI High/low pressure protection, safety protection, low water flow protection, antifreezing protection, compressor overload, lack of phase protection Magnetic bearing compressor Soft start 3 600 50 7 3 50 317 30 4780 0 100 5000 600 00 6460 6530 760 500 1759 87.9 6.11 71 4 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a 70 Flood type 1 C/7 C 50 303 0.0176 1.0 68 Shell &Tube heat exchanger 30 C/35 C 50 35 0.044 1.0 65 4780 0 100 5000 600 00 800 880 900 CC1930PWNI 550 1934 316.5 6.11 716 4 760 50 333 68 50 387 65 4780 0 100 5000 600 00 8300 8380 9400 17 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Except above standard models, haier also can be customized products according to customers' requirements ; 4. Due to our policy of innovation some specifications maybe changed without notification;" 5. Model CC1330PWNI~CC810PWNI is split type chiller, the installer need to combine the chiller on site;

*Picture is based on double compressor model MODEL EER Starting current Max. running current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Charge Water inlet/outlet temp Evaporator Rated water flow Water inlet/outlet temp Condenser Rated water flow Unit length External Unit width dimension Unit height Unit length Package Unit width dimension Unit height Net weight Weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) CC110PWNI 600 110 344. 6.13 70 CC460PWNI High/low pressure protection, safety protection, low water flow protection, antifreezing protection, compressor overload, lack of phase protection Magnetic bearing compressor Soft start 4 800 50 363 66 50 4 6 4780 0 100 5000 600 00 8350 8430 9450 700 46 40.3 6.1 894 5 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a 900 Flood type 1 C/7 C 300 43 0.0176 1.0 99 Shell &Tube heat exchanger 30 C/35 C 300 493 0.044 1.0 99 6450 40 100 6550 600 00 11 11300 1350 CC810PWNI 800 814 457.6 6.15 900 5 1000 300 484 99 300 563 95 6450 40 100 6550 600 00 11350 10 1650 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Except above standard models, haier also can be customized products according to customers' requirements ; 4. Due to our policy of innovation some specifications maybe changed without notification;" 5. Model CC1330PWNI~CC810PWNI is split type chiller, the installer need to combine the chiller on site; 18

WTER-COOLED OIL FREE CENTRIFUGL CHILLER *Picture is based on double compressor model MODEL EER Starting current Max. running current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Evaporator Condenser External dimension Package dimension Weight Charge Water inlet/outlet temp Rated water flow Water inlet/outlet temp Rated water flow Unit length Unit width Unit height Unit length Unit width Unit height Net weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) CC3170PWNI 900 3165 518.0 6.11 975 CC40PWNI 100 40 689.5 6.1 1440 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a CC6330PWNI High/low pressure protection, safety protection, low water flow protection, antifreezing protection, compressor overload, lack of phase protection Magnetic bearing compressor Soft start 6 100 350 544 99 350 633 99 4300 300 400 4500 3500 400 11950 1100 15450 8 1600 Flood type 1 C/7 C 350 75.9 0.0176 1.0 97 Shell &Tube heat exchanger 30 C/35 C 350 844 0.044 1.0 95 5100 3050 560 500 3500 660 15350 15500 19350 1800 6330.6 109.4 6.15 160 1 400 450 1088.9 97 450 166 96 7700 3500 500 7800 3650 660 5310 5460 9810 19 Note: 1. bove parameters is based on the standard products;. bove products standard pressure is 1.0 Mpa,if pressure higher than 1.0Mpa,should contact with haier technology engineer; 3. Except above standard models, haier also can be customized products according to customers' requirements ; 4. Due to our policy of innovation some specifications maybe changed without notification;" 5. Model CC1330PWNI~CC810PWNI is split type chiller, the installer need to combine the chiller on site;

Unit Dimension Diagram Water-cooled oil free centrifugal chiller dimension diagram Single compressor unit dimension diagram CC0440PWNI CC0530PWNI The double compressores chiller series connection standard, parallel connection is optional,below is unit dimension diagram Twin-compressor series connection unit dimension diagram CC0880PWNI CC1100PWNI 0

WTER-COOLED OIL FREE CENTRIFUGL CHILLER Unit Dimension Diagram The chiller with three compressor is parallel connection,and also can realize series connection for special requirements. This is the unit dimension diagram Three compressores series connection unit dimension diagram CC1330PWNI CCPWNI CC1580PWNI Four compressores parallel connection unit dimension diagram CC1760PWNI CC1930PWNI CC110PWNI 1

Unit Dimension Diagram Five compressores parallel connection unit dimension diagram CC460PWNI CC810PWNI Big oil free centrifugal chiller series(for example the model with six compressor) CC3170PWNI CC40PWNI CC6330PWNI Model CC3170PWNI CC40PWNI CC6330PWNI Dimension Installation Dimension Pipe Connection Dimension L W H B1 B B3 G1 G G3 D1 D F1 F M e c 4300 300 400 960 400 1060 3348 550 550 715 765 1310 350 350 5100 300 400 960 400 1060 4148 550 550 715 765 1310 350 350 7700 3500 500 1160 400 1160 3390 330 60 60 730 730 1460 450 450 Notes: 1, bove products direction of the evaporator and condenser water inlet and water outlet can be adjusted according to user requirements, Product diamension also can be changed if user have special requirements

OIL FREE CENTRIFUGL CHILLER The Unit Installation Foundation Drawing Water-cooled oil free centrifugal chiller installed base Single compressor & Twin-compressor series dimension 500 Model CC0440PWNI () B() 1846 346 00 CC0530PWNI 1846 346 CC0880PWNI 3719 419 790 1190 Square hole 4-100 100 CC1100PWNI 3719 419 50 B 400 300 Square hole100 100 ±0.00 Unit feet M0 bolt Nut Pad Rubber shock pad Soundation square hole diagram Three compressors series dimension 500 CC130PWNI CCPWNI CC1580PWNI 790 1190 Square hole 8-100 100 790 130 1190 400 300 Square hole100 100 ±0.00 Unit feet M0 bolt Nut Pad Rubber shock pad 00 1846 3719 50 Soundation square hole diagram 419 Four compressors series dimension 500 00 CC1760PWNI CC1930PWNI CC110PWNI 790 790 130 Square hole 8-100 100 400 300 Square hole100 100 ±0.00 Unit feet M0 bolt Nut Pad Rubber shock pad Soundation square hole diagram 50 3719 419 3

The Unit Installation Foundation Drawing Water-cooled oil free centrifugal chiller installed base Five compressors series dimension 500 CC460PWNI CC810PWNI 350 790 1930 330 Square hole 10-100 100 1190 400 300 Square hole100 100 ±0.00 Unit feet M0 bolt Nut Pad Rubber shock pad 00 Soundation square hole diagram 50 3710 1870 6080 Big chiller series dimension 500 Model () B() 50 00 960 400 1060 80 B Square hole 8-100 100 400 300 Square hole100 100 ±0.00 Soundation square hole diagram CC3170PWNI CC40PWNI Unit feet M0 bolt Nut Pad Rubber shock pad 3348 3848 4148 4648 500 00 1160 400 1160 310 Square hole 1-100 100 400 300 Square hole100 100 ±0.00 CC6330PWNI Unit feet M0 bolt Nut Pad Rubber shock pad 50 3390 330 710 Soundation square hole diagram 4

OIL FREE CENTRIFUGL CHILLER Installation Space Diagram Water-cooled oil free centrifugal chiller installation space diagram Model CC0440~CC0530PWNI CC0880~CC810PWNI CC3170PWNI CC40PWNI CC6330PWNI B C D E 500 500 1000 1000 1000 000 000 3500 4300 3500 0 0 0 0 0 0 0 0 0 0 1000 000 000 000 3500 Note: above data is minimum dimension Performance Table Water-cooled oil free centrifugal chiller performace table Chilled water oulet temp.( C) Performance table water inlet temperature( C) 4 6 8 30 3 34 36 5 0.9 0.73 0.95 0.81 0.98 0.88 0.96 0.95 0.96 1.0 0.95 1.08 0.94 1.15 0.9 1.0 6 0.93 0.71 0.95 0.80 0.97 0.88 0.98 0.95 0.98 1.01 0.97 1.08 0.97 1.16 0.95 1.1 7 0.94 0.69 0.97 0.77 0.99 0.86 0.99 0.9 1.00 1.00 1.00 1.07 0.99 1.14 0.98 1.1 8 0.98 0.67 0.98 0.75 1.00 0.83 1.0 0.9 1.03 0.99 1.03 1.07 1.03 1.14 1.0 1.1 9 0.96 0.63 0.99 0.7 1.01 0.81 1.04 0.90 0.98 1.1 1.0 10 0.95 0.60 1.00 0.70 1.03 0.78 0.87 1.07 0.96 1.08 1.03 1.08 1.11 1.08 1.0 11 0.93 0.5 1.00 0.63 0.73 1.07 0.8 1.10 0.91 1.1 1.01 1.1 1.08 1.13 1.16 1 0.93 0.5 0.96 0.50 1.04 0.53 1.09 0.71 1.14 0.83 1.16 0.9 1.19 1.0 1.1 1.13 13 0.93 0.5 0.96 0.50 1.04 0.47 0.57 1.13 0.69 1.19 0.8 1.3 0.93 1.5 1.13 5

MODULR WTER-COOLED OIL FREE CENTRIFUGL CHILLER MODEL EER Starting current Max. runnin current Safe protection Compressor Starting mode Quantity supply Refrigerant throttle type Capacity control Controller type Refrigerant Evaporator Condenser External dimension Weight * Data is pending Charge Water inlet/outlet temp Rated water flow Water inlet/outlet temp Rated water flow Unit length Unit width Unit height Net weight Gross weight Operation weight RT / Ph/V/Hz m 3 /h (m. C/) m 3 /h (m. C/) Kg Kg Kg CC030PWNN 90 30 55. 5.80 176 CC0400PWNN 114 400 71.4 5.60 178 compressor overload protection, safe protection, low water flow protection, antifreezing protection,fan motor overload protection,lack of phase protection Magnetic bearing compressor soft start 1 1 1 3N/380V/50Hz Electronic expansion valve 5%-100% PLC control R134a 80 85 100 falling film 1 C/7 C 55 60 75 75 1880 010 1890 1930 140 69 0.0176 1.0 60 Shell &Tube heat exchanger 30 C/35 C 95 0.044 1.0 75 1880 010 1950 1990 10 CC0500PWNN 14 500 89.3 5.60 180 86 55 110 80 1880 145 070 080 10 370 W L H Water Outlet c Water Inlet c F1 D1 M B M1 P F D Chilled Water Outlet e Chilled Water Iutlet e N B Fixing Holes G Model Dimension Installation Dimension Pipe Connection Dimension L W H B G P D1 D F1 F M1 M N e c CC030PWNN 1880 010 790 1380 105 60 440 1097 307 310 370 80 CC0400PWNN 1880 010 790 1380 105 60 440 1097 307 310 370 80 CC0500PWNN 1880 145 070 790 1380 105 60 440 11 307 310 370 80 6

THI TSKI ENGINEERING CO., LTD. 89/55 Moo0, Teparak Rd., Bangpleeyai, Bangplee, Samuthprakarn 10540 Tel. +66--75-5030 Fax. +66--75-40 E-mail : info@tasaki.co.th Website : www.tasaki.co.th www.bitwise.co.th www.tasaki.co.th Tasaki ir CT.NO.TS-DM-17R-0