w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Air to water Heat Pump System

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Do you want a versatile solution

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Air to water Heat Pump System

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

CHAPTER 6 CONDENSING UNITS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Advance Split

Air to Water Heat Pump

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

MACH N-407 Heat Pump Air-Cooled Chiller

.2 Section Waste Management and Disposal.

LZT High efficiency air to water heat pumps with E.V.I. compressors

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Installation Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.


Refrigeration Technology in Building Services Engineering

HT V2 HT Split

Condensing Units CUS 15-60

High temperature air-to-water heat pumps

SECTION WATER-SOURCE UNITARY HEAT PUMPS

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

LZA High efficiency air to water heat pumps with HP compressor

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

Samsung EHS Heat Pump Test

Call us today! (800)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

recooler HP EQKR HEAT PUMP

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Technical Data Ducted Three Phase Split System Air Conditioner

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Call us today! (800)

Air to Water Heat Pump

Call us today! (800)

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

GENERAL INFORMATIONS

50A KP 70A KP 90A KP 120A KP 150A KP 210A

TECHNICAL SPECIFICATIONS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

PRODUCT GUIDE

Frequently Asked Questions

we care about Better Air

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

ROOFTOP PACKAGED AIR CONDITIONERS

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

MAC N-407 Air-Cooled Chiller

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AQUAHEAT ADVANCE SPLIT

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

NFZP Variable Refrigerant Flow Guide Specification

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

500 EX Fusion Compressor Series

WHY A MHI HEAT PUMP?

Transcription:

Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components. It shall be the responsibility of the nominated installer to supply and install these system components in accordance with Toshiba Installation Guidelines. 1) Toshiba Estia Inverter external air cooled condensing unit(s) 2) Toshiba Estia Hydro box indoor unit(s) 3) Toshiba Domestic Hot Water Cylinder(s) 4) Interconnecting refrigerant pipe work from Outdoor Unit(s) to HydroUnit(s). System Operating Range Mode of operation Cooling Heating DHW Max. Outdoor Air Temperature Min. Outdoor Air Temperature 0 C db 43 25 43 0 C db 10-20 -20 Min / Max Leaving Water Temperature 0 C 10 to 30 20 to 55 20 to 75 System Description The installation shall provide an energy efficient R410A Direct Expansion (DX) split type Air to Water Heat Pump system(s) and shall be installed in accordance with relevant codes of practice and regulations. The system(s) shall comprise of a Toshiba Estia Inverter Heat Pump outdoor unit(s) connected to a Toshiba Estia hydro module unit(s). It is recommended that the refrigerant system installing contractor is a Refcom Certified Toshiba Additions Member. Full details on our website: www.toshiba-aircon.co.uk. Customer Support. The system(s) shall be controlled with Toshiba s in-built controls system. DELETE WARRANTIES THAT DO NOT APPLY All equipment supplied shall have a manufacturer s warranty of at least 3-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Registered installer or Qualified or Accredited

All equipment supplied shall have a manufacturer s warranty of 5-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Qualified or Accredited installer. All equipment supplied shall have a manufacturer s warranty of 5-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Qualified or Accredited installer. All equipment supplied shall have a manufacturer s 7 year Total Peace of Mind (TPM) warranty on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Accredited (TPM) installer. Design Criteria The air conditioning system(s) shall be designed and equipment selected to conform to the design criteria below ensuring that the heating load is covered by the heat pump (with the additional back up heater if required) at the most extreme outdoor condition of its proposed operation. External Conditions Summer 29 C Winter -5 C Leaving water temp Summer 10 C Winter 45 C DHW temp Summer 10 C Winter 55 C System Specification The system(s) shall be of the Toshiba Estia Inverter Air to Water Heat Pump variety. The system will be capable of both heating and cooling. Each system will use non-ozone depleting HFC refrigerant R410A. The system shall allow a user-driven operating environment to be established where users can directly request their own choice of temperature and on/off control etc. The equipment must be suitable for operating on a 220-240 Volt, single-phase, 50 Hz supply. The back up heaters for the hydro module will be 220-240 Volt, single-phase, 50 Hz supply. The back up heaters for the hydro module will be 400 Volt, three-phase, 50 Hz supply. Outdoor Unit(s) Toshiba Model References Max Piping Length Max Lift Max Drop HWS-804H-E 30 m 30 m 30 m

HWS-1104H-E 30 m 30 m 30 m HWS-1404H-E 30 m 30 m 30 m HWS-1104H8-E* 30 m 30 m 30 m HWS-1404H8-E* 30 m 30 m 30 m HWS-1604H8-E* 30 m 30 m 30 m *Denotes Three Phase High Temperature Range HWS-P804H-E 30m 30m 30m HWS-P1104H-E 30m 30m 30m The outdoor unit shall be factory assembled, pre-wired, works tested, supplied with a refrigerant pre-charge suitable for 30m of main piping and complete with fully sealed pipe work connections. It shall not be necessary to include oil traps, sight glasses, or external driers. The access panel shall be easily removable for servicing. The condensing unit shall be fitted with its own electrical compartment with all necessary electrical and control components. The casing shall be manufactured from Galvatite steel plate with a Silky Shade (Munsell 1Y8.5-0.5) electrostatic spray finish protected to IP X4 and shall contain the following components: Inverter Driven Twin Rotary Compressor The compressor shall be of the twin rotary type and driven by a High-Speed Calculation Vector Control Inverter, creating seamless capacity control to match the connected indoor unit(s) cooling or heating demand. Fixed speed compressors of any type are not to be used. The compressor shall be factory mounted on springs and shock-absorbing rubber to minimise vibration. Heat Exchanger The heat exchanger shall be factory constructed of rifled copper tubing, mechanically bonded to aluminium fins. The aluminium fin material shall be coated with a hydrophilic coating to prevent corrosion and to assist condensate dispersal. The coil shall have a large surface area to minimize noise and maximise heat transfer. Fan and Motor Each outdoor unit is to be fitted with no more than a single fan. The fan shall be a three-blade, flash-wing, low noise type and shall be both dynamically and statically balanced to produce minimum noise and vibration. The fan shall be directly coupled and driven by a drip proof, permanently lubricated variable speed high-efficiency inverter controlled motor. The outdoor fan speed shall be matched automatically to the energy demands of the heat exchanger. The fan must be able to overcome an external static resistance of 15Pa. Suction Line Accumulator The cylindrical accumulator shall be fabricated from press formed mild steel plates. The accumulator shall have sufficient capacity to prevent any liquid refrigerant from flowing back into the compressor section. Additional Features & Safety Devices: 4-way reversing valve, solenoid valves, pulse-modulating valve, strainer, dryer, service valves with 5/16 gauge ports, thermal protection for compressor, recycling guard timer, over-current protection, compressor suction and discharge temperature sensors, terminals, internal wiring and controls. A pulse-modulating valve will provide capacity control by maintaining suction

temperatures of between 1 and 5 K higher than the evaporator inlet temperature additionally, the indoor heat exchanger will be limited to temperatures of no less than 2ºC when cooling. The outdoor unit will automatically defrost in the heating cycle. Indoor Unit Hydro Modules Each indoor unit shall be from Toshiba s Estia Inverter range of Air to water heat pumps and must operate on 220-240 Volt, single-phase, 50 Hz supply fed from the outdoor unit. For the electrical back up heaters the power supplies shall be 220-240 Volt, single-phase, 50 Hz supply (HWS-xxxXWHM3 models) or 400 Volt, three phase, 50Hz supply (HWSxxxXWHM6 & XWHM9 models) all fed from a dedicated supply to the hydro module. A separate 220-240 Volt, single-phase, 50 Hz supply shall be used to feed the DHW tank if used. The heat exchanger shall be made of high grade stainless steel and will be mounted inside the hydro unit. All hydro modules are provided with return water and leaving water temperature sensors. The heat exchanger will be protected against excessive temperatures both low and high. Hydro Module Toshiba Model References: HWS-804XWHM3-E HWS-804XWHT6-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E High Temperature Range HWS-P804XWHM3-E HWS-P804XWHT6-E HWS-P804XWHM9-E HWS-P1104XWHT3-E HWS-P1104XWHM6-E HWS-P1104XWHT9-E The unit will be manufactured from powder coating steel sheet enclosing the heat exchanger, main system primary pump, control electronics, expansion vessel and electrical back up heater. The hot water connections and refrigerant connections are to the bottom of the unit.

Domestic Hot Water Tanks Toshiba Model References: HWS-1501CSHM3-UK (150 litre nominal capacity) HWS-2101CSHM3-UK (210 litre nominal capacity) HWS-3001CSHM3-UK (300 litre nominal capacity) The tanks will be manufactured from powder coated stainless steel and be available in three sizes as above. Each tank will have its own 3kW electrical immersion heater, hot water sensor and controls to link it to the Toshiba hydro unit. Each tank will be supplied with cold water combination valve (to meet UK water regulations), factory fitted temperature / pressure relief valve, T&P valve insulation and housing, expansion vessel and mounting bracket, tundish, compression nuts and olives and heater key spanner. Refrigerant Pipe-Work All pipe-work shall be manufactured using de-oxidised, refrigerant quality copper to BS EN 1057:1996, and must be heat-treated as follows: 9.5mm (3/48 ) OD to 15.9mm (5/8 ) OD - Soft, Half Hard or Hard Tempered The length/height difference parameters and outside diameter of all piping is to be in accordance with the appropriate Toshiba manuals. Interconnecting controls Wiring The nominated installer shall be responsible for the following interconnecting controls wiring: 3-core & earth = Outdoor unit to Indoor Unit (1, 2, 3 & E) 3-core = DHW Tank to Indoor Unit (1, 2 & E) All electrical wiring, bonding and earthing shall be in accordance with the current edition of BS 7671: 2008 (IEE Wiring Regulations 17 th Edition). The voltages stated are EC harmonised voltages, but the equipment shall be suitable for 200-240 volts single phase. Controls The Toshiba Estia Air to Water Heat Pump(s) shall be complete with the Toshiba in-built hard wired controller, fitted to the front of the hydro unit.

The remote controller(s) shall be surface mounted and hard wired to the hydro unit(s) and will provide the user with local individual control of the hot water temperatures. The controller shall be manufactured in ABS plastic with a liquid crystal display (LCD). The controller shall enable the user to interrogate the system and display an alphanumeric fault code in the event of system malfunction. The controller shall have the capability of accessing all the system function codes for customising the settings and operation of the system. The controller shall be able to provide control or indicate status of the following functions: Start/stop. Operating mode (autocurve, cool, heat). Temperature set point 2 zone temperature control Test run (heating & cooling). Schedule 7 day timer operation (Operation time, start/stop, temp setting & restriction) Minimum and maximum temperature settings in each mode Auto-restart. Sensor data available from all associated indoor and outdoor units Night operation setting for noise and temperature set back Hot water boost function Frost protection DHW anti bacteria function