Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Similar documents
SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units

Product Specifications. Vertical Floor Consoles By First Co.

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

FCC Fan-Coil Units High-Performance, Vertical

HiLine Vertical Stacking Fan Coil Units

HiLine Vertical Stacking Fan-coil Units

Ceiling Concealed Fan-Coil Unit

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

VERTICAL FAN COIL UNITS

SKYPAK II, 3 Ton Series, gives you a

EHH SERIES DRAW THROUGH FAN COILS CFM

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

SECTION FAN COIL UNITS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SKYPAK II, 3 Ton Series, gives you a

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Cabinet Unit Heaters Type CHF & CHB

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

catalog CDV Fan-Coil Units High-Performance, Vertical

Vertical V*B Series Fan Coil Technical Catalog

SKYPAK II Heating & Cooling Self Contained Packages

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

High Heat COP. High/Low Stage

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Cabinet Unit Heaters Steam / Hot Water

Advance Release September 2009

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

GUIDE SPECIFICATIONS AQUARIUS ii

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Incremental Comfort Conditioners

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

GUIDE SPECIFICATIONS AQUARIUS ii

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

technical guide Water-Cooled Self-Contained Units

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

C13-Series Engineering Guide

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Water-Cooled Self-Contained Units

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Split System Heat Pumps

RGE 13 A T - 1 A

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

AIR HANDLER SPECIFICATION

MERIT Series R-410A - Upflow / Horizontal

MACH N-407 Heat Pump Air-Cooled Chiller

LOW STATIC HYDRONIC DUCTED UNIT

CWA4 Chilled & Hot Water Fan Coil

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MERIT Series R-410A - Upflow / Horizontal

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Cooling/Heat Pump Convertible Air Handlers

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MERIT SERIES Up Flow / Horizontal

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

VariCool VAV Engineering Guide

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SECTION CONVECTION HEATING AND COOLING UNITS

Transcription:

Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM

McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal Concealed Unit TPF = Vertical Thinine Unit w/tamper-proof Cabinet TSH = Horizontal Thinine Unit w/o Cabinet TSC = Horizontal Thinine Unit w/cabinet TSB = Vertical Thinine Unit w/o Cabinet TSF = Vertical Thinine Unit w/cabinet TSS = Vertical Thinine Unit Slope Top - Metal Grille Description of Products: Nominal cfm in 100's H02 = 200 cfm H03 = 300 cfm H04 = 400 cfm H06 = 600 cfm H08 = 800 cfm H10 = 1000 cfm H12 = 1200 cfm Design Series 1 = A design 2 = B design 3 = C design etc. Agency isted All standard units All custom units Ratings certified by the Air Conditioning & Refrigeration Institute (ARI) Table of Contents Nomenclature... page 2 Introduction... page 3 Design Features... page 3 Parts Description... page 3 Options... page 4 Performance Data (2-Pipe System)... pages 5-6 Cooling Capacity (2-Pipe)... page 5 Heating Capacity (2-Pipe)... page 5 General Unit Data (2-Pipe)... page 5 Cooling Capacity (4-Pipe)... page 6 1-Row Heating Capacity (4-Pipe)... page 6 General Unit Data (4-Pipe)... page 6 Dimensional Data... page 7 Air Volume Capacity Data... page 8 Motor Data... page 8 Wiring Diagrams... page 9 Valve Package Wiring diagrams... page 9 Engineering Guide Specifications... page 10 Page 2 of 12 / Catalog 700

Introduction McQuay fan coil units have been widely applied in hotels, apartments, dormitories and military barracks, assisted living facilities and offices. McQuay fan coils have earned a reputation for quality - providing years of efficient, reliable, quiet heating and cooling - and easy, low-cost installation and maintenance. The Model THC horizontal concealed fan coil unit is a compact, lightweight unit that is ideal for installation in ceilings where space is limited. Units are available in seven sizes from 200 to 1,200 cfm. Design Features Ultra-Slim Profile The highly compact, super lightweight design of the Model THC fan coil unit makes it ideal for inside ceiling installations where space is limited. High Efficiency Coil Unique coil design promotes the mixture of warm and cold air, resulting in high thermal efficiency and lower operating costs. Quiet Centrifugal Fan Assembly High efficiency fan assembly minimizes vibration and noise. Indoor Air Quality Drain Pan The extended, positive slope drain pan is removable and is coated with an epoxy finish for easy cleaning to help prevent microbial growth and to fight corrosion. The drain pan is insulated with a form-fitted closed cell insulation to prevent condensation build-up on the outside of the drain pan. Insulation Out Of Airstream Aluminum foil face insulation on top panel prevents insulation fibers from entering the airstream for improved indoor air quality. Standard Return Air Plenum Unit ships standard with fully-insulated rear return air plenum. Field Flexible Piping Connections Units are easily converted to opposite-hand connection without requiring additional parts or a conversion kit. Units may be ordered with left hand or right hand piping connections. Threaded Or Sweat Connections Units ship standard with threaded connection. A threaded adapter is shipped loose with the unit for easy conversion to a sweat connection. Service-Friendly Manual Air Vent Air vent hand valve is conveniently located over the drain pan and does not require any tools to vent the coil. Parts Description Top Panels built to keep insulation out of airstream High Efficiency Coil Quiet Centrifugal Fan Assembly Service-friendly Manual Air Vent Terminal Box Field Flexible Piping Connections Extended Positive Slope, Indoor Air Quality Drain Pan Page 3 of 12 / Catalog 700

Options Valve Packages Two-way and three-way electric valves for field installation on 2-pipe and 4-pipe systems. Basic package includes electric valve with hand valves. Thermostats Wall-mounted thermostats for all application requirements are available as either thermostats only or combination thermostat and three-speed switch. Part # 107345202 Part # 107345201 Basic Valve Package, Two-Pipe, Two-Way Valve Thermostats with Three-speed Switches Part # 01181900 Kit # 107112101 Separate Wall Mounted Thermostat and Three-Speed Switch Page 4 of 12 / Catalog 700

Performance Data THC Horizontal Concealed (2-Pipe System) ARI Approved Standard Coil Water Cooling Capacity Ratings FTHC HORIZONTA CONCEAED UNIT UNIT COOING CAPACITY WATER WATER SIZE TOTA SENSIBE FOW P.D. BTUH BTUH GPM FT. W.C. H02 8500 6100 1.94 5.10 H03 11,100 8400 2.51 3.26 H04 14,500 10,800 3.26 5.80 H06 21,200 16,100 4.70 12.82 H08 22,700 18,000 5.14 3.68 H10 25,300 20,000 5.70 4.76 H12 34,200 27,000 7.75 8.29 Standard Coil Water Heating Capacity Ratings FTHC HORIZONTA CONCEAED UNIT UNIT HEATING CAPACITY WATER WATER SIZE SENSIBE FOW P.D. BTUH GPM FT. W.C. H02 14,900 1.94 5.10 H03 20,300 2.51 3.26 H04 26,800 3.26 5.80 H06 37,600 4.70 12.82 H08 42,400 5.14 3.68 H10 48,300 5.70 4.76 H12 68,800 7.75 8.29 Water heating coils at 70 F DB entering air, 140 F entering water, 30 F water temperature drop and high fan speed with standard 115/60/1 motor. For heating coil capacity ratings at conditions other than those listed refer to the RepTools Computer Selection Program or consult your McQuay representative. General Unit Data Unit Size H02 H03 H04 H06 H08 H10 H12 Fan Type Centrifugal Fan (forward-curved galvanized steel fan wheel) Number of Fans 1 1 2 2 3 3 4 Fan Housing Galvanized Steel Coil Number of Rows 3-Row Type Water - (3-Row Chilled Water/ Hot Water) Testing Pressure 425 psi for 1 minute; leak test: 225 psi for 5 minutes Motor(s) Type PSC Number of Motors 1 1 1 1 2 2 2 Power Supply 115/60/1, 208-230/50-60/1, 277/60/1 Watts - High Speed 50Hz 62 91 109 171 242 249 321 60Hz 75 109 131 205 291 299 385 Coil Connection 3/4" FPT Drain Pipe 3/4" MPT Unit with Return Air Plenum and Filter ength in. 21.90 21.90 21.90 21.90 21.90 21.90 21.90 Width in. 32.05 38.74 43.86 51.73 61.57 65.51 75.75 Height in. 9.88 9.88 9.88 9.88 9.88 9.88 9.88 Ship Weight lb. 61.00 69.00 83.00 97.00 127.00 137.00 146.00 Conditions: Cooling Capacity: Entering air temp.80 F (DB), 67 F (WB); Entering water temp.45 F, eaving water temp. 55 F. Heating Capacity: Entering air temp.70 F (DB); Entering water temp.140 F, The same amount of water flow with cooling. Air Flow: Under dry coil conditions, fan speed high. Weight: Includes return air plenum and packing. Page 5 of 12 / Catalog 700

Performance Data THC Horizontal Concealed (4-Pipe System) ARI Approved Standard Coil Water Cooling Capacity Ratings FTHC HORIZONTA CONCEAED UNIT UNIT COOING CAPACITY WATER WATER SIZE TOTA SENSIBE FOW P.D. BTUH BTUH GPM FT. W.C. H02 8500 6100 1.94 5.10 H03 11,100 8400 2.51 3.26 H04 14,500 10,800 3.26 5.80 H06 21,200 16,100 4.70 12.82 H08 22,700 18,000 5.14 3.68 H10 25,300 20,000 5.70 4.76 H12 34,200 27,000 7.75 8.29 Standard Coil Water 1-Row Heating Capacity Ratings FTHC HORIZONTA CONCEAED UNIT UNIT 1-ROW HEATING CAPACITY WATER WATER SIZE SENSIBE FOW P.D. BTUH GPM FT. W.C. H02 11,500 0.64 1.47 H03 16,300 0.91 2.89 H04 20,400 1.12 5.32 H06 29,600 1.65 10.72 H08 36,100 2.00 3.24 H10 40,300 2.24 4.07 H12 49,800 2.76 6.45 Water heating coils at 70 F DB entering air, 180 F entering water, 40 F water temperature drop and high fan speed with standard 115/60/1 motor. For heating coil capacity ratings at conditions other than those listed refer to the RepTools Computer Selection Program or consult your McQuay representative. General Unit Data Unit Size H02 H03 H04 H06 H08 H10 H12 Fan Type Centrifugal Fan (forward-curved galvanized steel fan wheel) Number of Fans 1 1 2 2 3 3 4 Fan Housing Galvanized Steel Coil Number of Rows 3/1 Split Type Water - (3-Row Chilled Water) (1-Row Hot Water) Testing Pressure 425 psi for 1 minute; leak test: 225 psi for 5 minutes Motor(s) Type PSC Number of Motors 1 1 1 1 2 2 2 Power Supply 115/60/1, 208-230/50/60/1, 277/60/1 Watts - High Speed 50Hz 62 91 109 171 242 249 321 60Hz 75 109 131 205 291 299 385 Coil Connection 3/4" FPT Drain Pipe 3/4" MPT Unit with Return Air Plenum and Filter ength in. 21.90 21.90 21.90 21.90 21.90 21.90 21.90 Width in. 32.05 38.74 43.86 51.73 61.57 65.51 75.75 Height in. 9.88 9.88 9.88 9.88 9.88 9.88 9.88 Ship Weight lb. 63.00 73.00 88.00 102.00 134.00 143.00 153.00 Conditions: Cooling Capacity: Entering air temp.80 F (DB), 67 F (WB); Entering water temp.45 F, eaving water temp. 55 F. Heating Capacity: Entering air temp.70 F (DB); Entering water temp.180 F. Air Flow: Under dry coil conditions, fan speed high. Weight: Includes return air plenum and packing. Page 6 of 12 / Catalog 700

Dimensional Data THC Horizontal Concealed, with Plenum Box Filters Unit Size A B C D E F Size Qty H02 32.05" 17.64" 19.17" 19.96" 18.46" 21.13" 18 1 /8" x 8" x 1" 1 H03 38.74" 24.33" 25.87" 26.65" 25.15" 27.82" 24 7 /8" x 8" x 1" 1 H04 43.86" 29.45" 30.98" 31.77" 30.20" 32.94" 29 7 /8" x 8" x 1" 1 H06 51.73" 37.32" 38.86" 39.65" 38.07" 40.82" 18 7 /8" x 8" x 1" 2 H08 61.57" 47.17" 48.70" 49.49" 47.91" 50.66" 23 3 /4" x 8" x 1" 2 H10 65.51" 51.10" 52.64" 53.43" 51.85" 54.60" 25 3 /4" x 8" x 1" 2 H12 75.75" 61.34" 62.87" 63.66" 62.09" 64.83" 30 7 /8" x 8" x 1" 2 F D E FITER 2 - R/A PENUM MOUNTING HOES 3/8" x 5/8" 8.75" 4 - MOUNTING HOES 3/8" x 5/8" 2.32" 7.36" CONDENSATE DRAIN 3/4" MPT 1.5" AIR VENT 2" B C A 6.38" 9.75" TOP VIEW Plenum Back with Filter 1.02" 5.75" 9.75" FRONT VIEW 1.40" CONDENSATE DRAIN 3/4" MPT FITER RAI 1.25" 1.25" 4.53" 9.25" 23.25" 1.73" CHIED WATER CONNECTION 3/4" FPT 12.75" TERMINA BOCK 1.25" 1.25" 5.82" WATER RETURN CONNECTION 3/4" FPT 9.25" 23.25" TERMINA BOCK 2.75" 9.88" 3.46" 9.88" 4.72" 8.125" HOT WATER CONNECTION 3/4" FPT 9.53" WATER SUPPY CONNECTION 3/4" FPT 9.53" 4-Pipe System - Right Hand Unit* *Factory supplied left hand units also available 2-Pipe System - Right Hand Unit* Page 7 of 12 / Catalog 700

Air Volume Capacity Data Air volume versus external static pressure Unit Size Fan Motor Speed High Medium ow External Static Pressure (INCHES OF WATER) External Static Pressure (INCHES OF WATER) External Static Pressure (INCHES OF WATER).00.05.10.15.20.25.30.00.05.10.15.20.25.30.00.05.10.15.20.25.30 H02 Air Flow cfm 311 288 270 255 236 224 207 231 211 195 178 164 152 134 181 157 139 125 111 94 87 RPM 1043 1138 1172 1194 1240 1262 1291 869 879 966 1012 1051 1108 1119 704 773 826 887 965 1032 1091 H03 Air Flow cfm 423 398 383 366 343 326 308 298 277 262 244 229 213 197 235 218 200 184 165 148 133 RPM 1143 1172 1202 1226 1255 1282 1313 838 890 945 992 1043 1097 1144 714 756 833 886 953 1023 1081 H04 Air Flow cfm 507 472 444 416 386 359 326 340 298 267 239 209 181 153 274 234 197 170 143 111 83 RPM 1122 1165 1201 1221 1258 1285 1314 788 851 903 964 1043 1093 1156 678 737 811 891 957 1028 1091 H06 Air Flow cfm 798 770 742 714 688 654 627 578 549 534 508 483 456 432 518 497 471 444 425 406 376 RPM 1295 1311 1333 1361 1382 1399 1416 990 1017 1060 1102 1151 1182 1230 894 937 994 1049 1086 1141 1181 H08 Air Flow cfm 949 918 874 833 788 747 716 740 703 671 632 594 550 517 662 632 601 554 521 490 449 RPM 1172 1192 1221 1259 1286 1320 1341 931 1003 1027 1072 1124 1167 1219 892 935 956 1014 1070 1121 1174 H10 Air Flow cfm 1032 981 932 881 836 712 716 775 723 688 631 582 533 493 697 643 602 538 496 463 410 RPM 1251 1279 1303 1331 1344 1386 1412 984 1037 1068 1115 1169 1245 1255 902 969 1001 1062 1123 1161 1204 H12 Air Flow cfm 1428 1380 1334 1287 1229 1173 1114 1067 1022 976 927 875 833 781 960 912 877 826 788 806 705 RPM 1344 1367 1389 1408 2845 2886 1462 1039 1062 1106 1149 1192 1235 1277 958 1003 1043 1095 1141 1178 1224 Note: Based on 115V operation, and dry coils. Motor Data Fan Unit Size Motor H02 H03 H04 H06 H08 H10 H12 Speed Amps Watts RPM Amps Watts RPM Amps Watts RPM Amps Watts RPM Amps Watts RPM Amps Watts RPM Amps Watts RPM 115/60/1 High 0.7 75 1043 1.0 109 1143 1.2 131 1122 1.8 205 1295 2.6 291 1172 2.7 299 1251 3.5 385 1344 Medium 0.6 61 869 0.7 73 838 0.9 93 788 1.4 155 990 2.0 229 931 2.0 225 984 2.7 305 1039 ow 0.5 53 704 0.6 63 714 0.8 83 678 1.3 145 894 1.9 211 892 1.9 211 902 2.5 279 958 Note: Based on 115V operation, dry coil, and 0.0 ESP. Page 8 of 12 / Catalog 700

Wiring Diagrams For Models: THCH02, THCH03, THCH04, and THCH06 Wiring (115V/1P/60Hz)(208-230V/1P/60Hz)(265/277V/1P/60Hz) Wiring (220V/1P/50Hz) FAN SPEED SWITCH M H F MF HF SHF ORANGE BROWN YEOW M~ FAN SPEED SWITCH M H F MF HF SHF ORANGE BROWN YEOW M~ POWER WHITE SOURCE MAIN SWITCH N G BUE POWER SOURCE WHITE MAIN SWITCH N BUE NOTE: NOTE: FIED WIRING M~: FAN MOTOR : GREEN/YEOW F: FAN SPEED OW MF: FAN SPEED MEDIUM HF: FAN SPEED HIGH SHF: FAN SPEED SUPER HIGH FIED WIRING M~: FAN MOTOR : GREEN/YEOW F: FAN SPEED OW MF: FAN SPEED MEDIUM HF: FAN SPEED HIGH SHF: FAN SPEED SUPER HIGH For Models: THCH08, THCH10, THCH12 FAN SPEED SWITCH M F MF HF ORANGE BROWN YEOW M1 FAN SPEED SWITCH M F MF HF ORANGE BROWN YEOW M1 H SHF H SHF POWER SOURCE NOTE: WHITE MAIN SWITCH N G BUE ORANGE BROWN YEOW M2 POWER SOURCE NOTE: WHITE MAIN SWITCH N BUE ORANGE BROWN YEOW M2 FIED WIRING M1,M2: FAN MOTOR : GREEN/YEOW F: FAN SPEED OW MF: FAN SPEED MEDIUM HF: FAN SPEED HIGH SHF: FAN SPEED SUPER HIGH FIED WIRING M1,M2: FAN MOTOR : GREEN/YEOW F: FAN SPEED OW MF: FAN SPEED MEDIUM HF: FAN SPEED HIGH SHF: FAN SPEED SUPER HIGH Valve Package Wiring Diagrams Control Wiring Schematic - Heating/Cooling 2-Pipe With Automatic Changeover Control Wiring Schematic - Heating/Cooling 4-Pipe With Sequencing Thermostat ORG ORG CG BU BU CG BU BK CG V WHT WHT TCI HTG C/O BK BK V WHT TCI HTG BK HTG V WHT egend 16 Wire No. WHT Wire Color Wire Connector Field Connector HTG TCI Heating Thermostat C/O Change over Switch (Manual or Auto) Wire Connector CG Cooling V Valve Page 9 of 12 / Catalog 700

McQuay THC Horizonal Concealed Fan Coil Engineering Guide Specifications Furnish and install where shown on the plans and specifications, McQuay THC Horizontal Concealed Fan-Coil Units. Types, sizes and performance shall be as tabulated in the schedule. Unit performance shall be substantiated by computer generated output data. Each unit shall be ARI certified and consist of and comply with the following: Construction General Basic unit shall consist of a base casing and return air plenum fabricated of heavy gauge galvanized steel with four-sided one inch duct collar for an easy connections to discharge duct work. Return air plenum shall have filter frame with 3/4" return air duct collar. Plenum shall be fully insulated with foil faced, thermal and acoustical insulation to prevent glass fibers in the air stream, unit sweating, and to attenuate fan noise. Electrical Unit shall be furnished with a single point power location, terminal strip and junction box for motor and other electrical terminations. Coils Coils shall have aluminum fins with copper tubes mechanically expanded for a permanent bond. Coils shall have a Brass Header with 3/4" FPT connections. Two (2) 3/4" MPT x 1/2" copper male adapters shall be provided by the manufacturer for sweat connection to copper pipe. Coils are tested at 425 psi. for one minute and 225 psi for five minutes. Water coils shall have a hand operated, manual air vent requiring no tools for the venting operation. Coil performance shall be as tabulated in the schedule. Fan Assembly Unit fan(s) shall be dynamically balanced, forward curved, double width, double inlet scroll centrifugal type constructed of galvanized steel for corrosion resistance. Motors shall have (115/60/1) (208-230/60/1) (265/60/1) three-speed, permanently lubricated sleeve bearing; permanent split capacitor with U listed automatic reset thermal overload. Drain Pan Shall be removable, cleanable, constructed of epoxy coated heavy gauge galvanized steel and externally insulated with 1/8" closed cell insulation. Insulation Hideaway return air plenum shall be fully insulated with foil faced, thermal and acoustical insulation to prevent glass fibers in the air stream, unit sweating, and to attenuate fan noise. Filters Standard filter shall be nominal 1" throwaway type. Optional Accessories Speed Control Units shall have a three-speed switch with integral on/off switch suitable for remote mounting and shall provide high/ medium/low fan speed control. Valve Packages Shall consist of two or three-way, two position motorized valve with hand gate valve on supply and hand ball valve on return piping. Two-way packages shall have standard bypass line for optional changeover aquastat. Thermostats Wall mounted for all application requirements. Thermostats are available as either thermostat only or combination thermostat and three-speed switch. Page 10 of 12 / Catalog 700

Page 11 of 12 / Catalog 700

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. 2004 McQuay International www.mcquay.com 1.800.432.1342 Catalog 700 / Page 12 of 12 (10-04)