VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

Similar documents
ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

FTQ. Daikin Inverter Ducted Heat Pump

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

About Daikin: WARNINGS:

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

FBQ. DC Duct Heat Pump or Cooling Only

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

LV Series. SEER 15+ Concealed Built in Heat Pump

FAQ. Wall Mount Heat Pump or Cooling Only

Residential and Light Commercial Ductless Systems Catalog

Up to SEER 26.1 Wall Mount Heat Pump

VRV LIFE Reference Guide

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

A revolutionary side discharge system that won t compromise on comfort. The Daikin Fit system offers solutions when a traditional cube style cannot.

A WORLD LEADING MANUFACTURER

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

NFZP Variable Refrigerant Flow Guide Specification

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

LV Series. SEER 20+ Wall Mount Heat Pump

TECHNICAL SPECIFICATIONS

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT PORTFOLIO

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

VRV HEAT RECOVERY

LG VRF Systems. Air Conditioning Technologies

TECHNICAL SPECIFICATIONS B6VMMX

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Lennox Mini-Split Systems Year-Round Comfort and Performance

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT CATALOG

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

10.17 PRODUCT CATALOG

Here is the common bond that can put it all together.

Variable Refrigerant Flow

Daikin Inverter Ducted Systems

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

DAIKIN SPLIT SYSTEM AIR CONDITIONERS AND COILS

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Product Data INDUSTRY LEADING FEATURES / BENEFITS

The Multi-talented VRV-S.

AIR HANDLERS R-410A, Variable-Speed TOUGH. SMART.

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

PACKAGED DUAL FUEL UNIT ENERGY-EFFICIENT COMPRESSOR. UP TO 14.5 SEER, 8.0 HSPF, 81% AFUE Multi-Position Installation

ELECTRICAL QUANTITY WEIGHT (LB)

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Performance and Reliability. CB*, C* and TA* Models

SKYPAK II, 3 Ton Series, gives you a

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

MXL SERIES - ENHANCED CAPACITY

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

"I'm a Daikin Comfort Pro"

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

SKYPAK II, 3 Ton Series, gives you a

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

ICP Inverter Heat Pump Application Guideline

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

AND WORRY-FREE PERFORMANCE

K sin. Mini Split Air Conditioners and Heat Pump

3 rd Generation of VRV. The professional solution for your professional project

Ductless Split Systems Concealed Duct Heat Pumps

A single answer for multiple zones.

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

DAIKIN SPLIT SYSTEM HEAT PUMPS AND AIR HANDLERS

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

THE WORLD S MOST EFFICIENT HEAT PUMP

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

2017 LINE UP MINI SPLITS CATALOG

DZ20VC HEAT PUMP HIGH-EFFICIENCY, INVERTER TECHNOLOGY UP TO 21 SEER UP TO 10 HSPF VARIABLE-SPEED COMFORTNET COMPATIBLE COMFORT FOR LIFE

TECHNICAL SPECIFICATIONS

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

TECHNICAL SPECIFICATIONS

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Technical Product Guide

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

Transcription:

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

DAIKIN VRV LIFE Re-inventing residential air-conditioning by breaking technological barriers, Daikin VRV LIFE systems bring inverter driven VRV technology to solve some of the age-old residential HVAC challenges. Precision engineered for flexibility, zoning, low sound and space saving, with the ability to mix and match ducted and duct-free indoor units in combination with a gas furnace. VRV LIFE systems are an ideal choice for a premium solution. SOLVING HVAC CHALLENGES Zoning Modern homes demand zoning for improved comfort and control. Existing air duct zoning kits can quickly add cost, space and complexity of installation. It also does not always provide the desired comfort levels. Many homes are left with areas which are too warm in summer or too cold in winter. Operational Efficiencies Traditional single speed solutions offer basic ON/OFF operation mode only. With the compressor turning ON/ OFF constantly, the increased current inrush leads to higher running costs. With little-to-no zoning, operating the entire system when unnecessary reduces savings opportunities. Sound The ON/OFF cycles of a traditional single speed system are often accompanied by undesirable operational sounds. These continuous sounds can become a nuisance in yards especially at night or when it is close to a window. Installing traditional units in sound sensitive applications or close to lot lines leaves homeowners with limited options. Flexibility Traditional single-speed ON/OFF systems provide little to no flexibility for adding zones at a later date as the usage of the home changes or expands. The common practice of adding systems to address the HVAC needs of the new zone quickly add cost and reduce yard space. 2 www.daikincomfort.com

THE DAIKIN SOLUTION Flexible Dual-Fuel 3 Up to 9 Zones Dual Gas Furnace Two-Zone Heat Pump Up to 9 Zones Heat Pump or Gas Furnace Single-Zone Daikin VRV LIFE systems are the industry s first VRV Heat Pump with gas furnace connectivity for residential applications. The new VRV LIFE systems offers solutions to some of the traditional HVAC challenges for single family applications. Zoning Daikin VRV LIFE systems provides effective zoning solutions by offering the flexibility to connect up to 9 1 refrigerant zones to a single system. Precision engineered refrigerant control allows system operation to meet the needs of individual zones. Sound Daikin VRV systems are globally renowned for their quietness. With operating sound pressure levels as low as 57 dba 1, VRV LIFE is an optimal solution for installation close to lot lines and sound sensitive applications. Operational Efficiencies Space VRV LIFE systems are engineered with Daikin inverter With a compact, light weight and space saving design and variable refrigerant temperature (VRT) technologies. of only 37 W x 12-5/8 D, VRV LIFE systems provides These empower the compressor to operate at its up to 75% 2 reduction in installation space compared to optimal efficiencies during part load operations and similar capacity top discharge unitary condensing units. thereby reducing power consumption* and providing high operational efficiencies. * Compared to non-inverter units 1 Model specific, refer to product engineering manual for details. 2 When compared to a system of two outdoor units combined with two gas furnaces and A-Coils. VRV LIFE 3 Dual-Fuel is achieveable only when VRV indoor units and gas furnace and A-Coil are connected to one VRV LIFE unit. 3

VRV LIFE VRV LIFE OUTDOOR RXSQ_TAVJU Features and Benefits Available in 2, 3, 4 and 5-Ton models Excellent zoning flexibility with 1-to-1 and 1-to-multi connections Broader diversity with ability to provide cooling and heating in up to 9 zones 1 Ability to choose heat pump or multi-zone Dual-Fuel 2 heating capability Auto and programmable modes for heat pump to gas heat switch over temperatures Compatible with 12 types and 65 models of Daikin VRV indoor fan coil units and 80 97% AFUE Daikin up flow and down flow communicating gas furnaces Dependable heat pump operation in extreme ambient conditions down to -4 F in heating mode and up to 122 F in cooling mode Year round comfort and energy savings delivered by combining VRV and VRT technologies compared to traditional split systems Operation with sound levels of under 58 dba 1 make for easy install close to lot lines Reduced installation cost with re-use of existing refrigerant lines and uninsulated liquid line 3 Engineered with Daikin s swing Inverter compressor technology Backed by 10-Year Parts Limited Warranty and 10- Year Replacement Compressor Limited Warranty* replacement compressor * Complete warranty details available from your local Daikin manufacturer s representative or distributor or online at www.daikincomfort.com. 1 Variable Speed DC Fan. High efficiency and low 2 sound levels. Efficiency (%) 100 80 60 DC Motor Efficiency (Comparison with a Conventional AC Motor) DC Motor Approx. 20% Increase 40 AC Motor 20 Approx. 40% Increase 0 200 300 400 500 600 700 800 900 1000 Motor Speed (RPM) Note: Data is based on studies conducted under controlled conditions at a Daikin laboratory. Blue Fin Corrosion Coating. 1000 hours salt spray rated as standard. Hydrophilic coating to help with defrost. 2 1 6 4 3 7mm Coil. High heat exchanger efficiency and compact casing design. 4 5 Inverter Board Cooled by Refrigerant Circuit 1. Elimination of condenser fan pressure drop caused by heat sink used on previous generations. New Swing Compressor. High efficiency. Low sound levels. 6 Configurable auto changeover to auxiliary heat. 1 Model specific, refer to product engineering manual for details. 3 5 Neodymium magnets 2 Dual-Fuel is achieveable only when VRV indoor units and gas furnace and A-Coil are connected to one VRV LIFE unit. 3 Rules apply, refer to installation manual for details. 4 www.daikincomfort.com

INVERTER VRV IV STRATOS DRIVEN FEATURES VRV LIFE DAIKIN INVERTER TECHNOLOGY Wouldn t it be great if your cooling and heating system weren t an energy hog? Daikin inverter technology helps systems run at an energy-conserving level, despite the climate conditions, by making slight adjustments to the compressor s speed. Daikin systems will reach the desired temperature faster and maintain a more constant temperature compared to traditional ON/OFF systems. It will not frequently start and stop the old fashioned way just as a car is more efficient and comfortable traveling on a highway than it is in stop-and-go city traffic. speed Desired speed Traditional non-inverter systems Inverter System Time SWING VS. ROTARY COMPRESSOR SWING ROTARY VRV LIFE Systems are engineered with Daikin swing compressors Main moving parts are integrated into one main component minimizing wear and tear Designed to eliminate refrigerant leaks from high side to low side Best compressor choice for high efficiencies under 65,000 Btu/h systems VARIABLE REFRIGERANT TEMPERATURE VRT VRT mode control selection to match user preferences These charts reflect the operation trend of a VRV system when in normal operation and under VRT control. Actual energy savings through VRT vary based on the building location, load characteristics, occupancy and system usage conditions. A view of the various VRT modes of operation: Automatic mode (Default setting on VRV LIFE) High sensible mode Basic mode (Traditional VRF system) Comfort control Energy saving control Comfort control Energy saving control Comfort control Energy saving control The perfect balance: Energy saving control throughout most of the year. Maximum comfort control on the hottest and coldest days of the year. Year round energy saving control. Ideal for dryer climates. Quick reaction to peak load to maintain set point. VRV LIFE 5

WHY CHOOSE VRV LIFE? APPLICATION Flexibility with mix-match of ducted and duct-free indoor units Reduced power consumption with flexibility to turn off indoor units not in use Dual-fuel heating with heat pump and gas heat simultaneously Space-saving with ability to connect 2 gas furnaces to one outdoor unit 2 Quiet operation with sound levels under 58 dba 1 Choice of gas or heat pump heat Custom, selectable and programmable temperature to switch from heat pump to gas heat Add or remove zones without having to worry about ductwork 97% AFUE GAS FURNACE & CXTQ_TASBLU Quiet operation 3 VRV LIFE Systems generates less noise than a comparable single speed top discharge Unitary system 3 operating at 73 dba Sound levels as low as: Washing Machine Daikin DZ14SA Dryer VRV LIFE Systems Average Home Background Music Quiet Library Whisper Quiet Bedroom at Night Sound Recording Room Normal Breathing Threshold of Hearing FXDQ_MVJU SLIM-DUCT CEILING UNIT 1 Model specific, refer to product engineering manual for details. 3 When compared to Daikin DZ14SA. 6 www.daikincomfort.com 2 When compared to a system of two outdoor units combined with two gas furnaces and A-Coils.

HEATING AND SPACE-SAVING SOLUTIONS DUAL-FUEL HEATING Flexibility to switch between gas or heat pump heating at various temperatures Expanded range of heating capabilities with pump heat down to -4 F Built-in auto changeover between heat pump and gas heat Continuous gas furnace heating during defrost avoids cold drafts Master Bedroom 1T Media 1T Heat Pump Heating Refrigerant Tank FXAQ_PVJU WALL-MOUNTED UNIT Up to 75% Reduction in Install Space 3 Space Saving Compact Design With clearance space as little as 4 1 from a wall and compact dimensions of 37 W x 12-5/8 D, VRV LIFE minimizes space required for outdoor unit installation. In modern homes with zoning using two separate systems, leveraging the advanced zoning and flexibility offered by VRV LIFE, up to 75% 2 reduction in space required for installation can be achieved. 1 Rules apply, refer to installation 2 When compared to a system of two manual for details. outdoor units combined VRV with LIFE two gas furnaces and A-Coils. 3 When compared to Daikin DZ14SA. 7

DAIKIN SWING COMPRESSOR VRV IV STRATOS FEATURES EXTENSIVE PIPING CAPABILITIES Refrigerant Piping Limitations With allowable vertical separation between outdoor and indoor units of up to 98 ft. 1, VRV LIFE Systems are a great choice for most single, two and three-story homes The flexibility to handle up to 492 ft. 1 of total piping allows for installing VRV LIFE Systems at a distance from the home Customizable on-site field settings can enable re-use of existing larger diameter pipes or un-insulated liquid line 2 1 Model specific, refer to product engineering manual for details. 2 Rules apply, refer to installation manual for details. FLEXIBILITY OF INDOOR UNITS A LIQUID LINE MAX (Ft.) RXSQ24-36 RXSQ48-60 Vertical Separation ODU and IDU (Above and below) 98 98 B Vertical Separation IDU and IDU 33 49 C+D Actual Piping Length 100 100 C+D Equivalent Piplng Length 125 125 C Actual Piping Length after first RefNet 100 100 Total Piping Length 328 492 D Permissible to reuse an existing main line set only. See following refrigerant piping section for requirements. A choice of 12 types and over 65 models, the freedom to select a combination of ducted and duct-free indoor units, and the ability to mix and match any indoor unit while combining with a Gas Furnace and A-Coil to one system gives VRV LIFE Systems un-matched flexibility. Cased A-Coil 2 5 Tons 4-Way Ceiling Suspended Cassette 1.5 3 Tons Wall-Mounted 0.6 2 Tons VISTA 2 x2 4-Way Cassette 0.6 1.5 Tons Duct Free Units Daikin Gas Furnaces 80% / 96% / 97% Slim Duct Concealed 0.6 2 Tons Wide Indoor Lineup Suitable for Residential Applications 3 x3 Round Flow Cassette 0.6 4 Tons Ceiling Suspended 1 3 Tons Ducted Units DC Ducted Concealed 0.6 4.5 Tons Multi Position 0.8 5 Tons 8 www.daikincomfort.com Concealed Floor Standing 0.6 2 Tons Exposed Floor Standing 0.6 2 Tons One-Way Blow 0.6 2 Tons

VRV IV STRATOS LIFE FEATURES SPECIFIC INDOOR UNITS CXTQ ALL ALUMINUM COIL Available in 2, 3, 4, and 5-Ton capacities Engineered for compatibility with VRV LIFE outdoor units 1 Rules apply, refer to installation manual for details. Factory installed electronic expansion valve with PID control loop for precision capacity control Seamless integration to full suite of Daikin controls using onboard control board Air cleaner and humidifier integration capable 1 UV and rust resistant, 5VA rated thermoplastic drain pan with integrated secondary drain Foil-faced insulation covers internal casing to reduce cabinet condensation Split seam front for easy installation and service access Light weight all aluminum evaporator coil Ships factory standard up flow with easy field conversion to downflow 1 Backed by best-in-class 10-Year Parts Limited Warranty* *Complete warranty details available from your local Daikin manufacturer s representative or distributor or online at www.daikincomfort.com. DAIKIN 80-97% AFUE COMMUNICATING GAS FURNACE Durable heat exchanger Unique tubular stainless-steel construction formed using wrinkle-bend technology results in an extremely durable heat exchanger. Paired with a stainless-steel secondary heat exchanger, this combination provides for reliability, durability and efficiency. Modulating gas valve Operates between 35% - 100% capacity, providing precise efficiency and the ultimate in comfort. Continuous air circulation Provides added filtration and keeps air moving throughout your home to help maintain comfort. For information on other VRV indoor units, refer to the product specific flyers at www.daikinac.com VRV LIFE 9

VRV INDOOR UNITS VRV IV STRATOS FEATURES INDOOR UNIT TYPE MBH TONS 5.8 0.48 7.5 0.6 09 0.75 12 1 15 1.25 CAPACITY 24 30 2 2.5 18 1.5 36 3 42 3.5 48 4 54 4.5 60 5 DUCTED FXMQ-PBVJU DC-Ducted Concealed Ceiling (Medium Static) FXDQ-MVJU Slim Duct Built-In Concealed Ceiling Unit FXTQ_TAVJU Multi-Position Air Handling Unit (Upflow, Downflow, Horizontal Left and Horizontal Right) FXNQ-MVJU9 Concealed Floor- Standing Unit FXFQ-TVJU Round Flow Sensing Cassette, Ceiling Mounted DUCT-FREE FXUQ-PVJU 4-Way Blow Ceiling-Suspended Cassette FXZQ-TAVJU VISTA 2' X 2' Ceiling-Mounted Cassette FXEQ-PVJU Ceiling-Mounted Cassette (Single Flow) FXAQ-PVJU Wall-Mounted Unit FXLQ-MVJU9 Floor-Standing Unit Comfort cooling/heating EFFICIENCY Condensate pump standard 1 Dual-Fuel System Dual Gas Furnace Multi-Zone Two-Zone SEER Up to 18.0 HSPF Up to 10.5 Heat Pump Multi-Zone SEER Up to 18.0 HSPF Up to 10.5 Heat Pump or Gas Furnace Single-Zone SEER Up to 18.0 HSPF Up to 10.5 10 www.daikincomfort.com SEER Up to 16.0 HSPF Up to 10.0 1 Refer to AHRI directory for combination-specific ratings.

VRV LIFE SPECIFICATIONS VRV LIFE OUTDOOR RXSQ Model Name RXSQ24TAVJU RXSQ36TAVJU RXSQ48TAVJU RXSQ60TAVJU Single Fan Single Fan Single Fan Double Fan ODU Style Fan Type PERFORMANCE Nominal Cooling Capacity BTU/h 24,000 36,000 48,000 57,500 Nominal Heating Capacity BTU/h 27,000 40,000 52,000 57,500 Operation Range Cooling F DB 23 to 122 Operation Range Heating F WB -4 to 60 Power V/p/Hz 208-230/1/60 Sound Pressure Level @ 3ft. db(a) 58 57 REFRIGERANT PIPING CONNECTION RATIO UNIT FAN ELECTRICAL COMPRESSOR Refrigerant R-410A Refrigerant Quantity lbs 6.4 7.5 7.9 Liquid Pipe (Main Line) in 3/8 Suction Gas Pipe (Main Line) in 5/8 3/4 Vertical Pipe Length ft. 98 Maximum vertical pipe length between IDU ft. 33 49 Actual Pipe Length (Equivalent Length) ft. 100 (125) Total Piping Length ft. 328 492 Connectible Indoor Unit Ratio % 50-130 Number of Indoor Units Qty 4 6 8 9 Outdoor Unit Size (HxWxD) 39 x 37 x 12-5/8 39 x 37 x 12-5/8 52-15/16 x 35-7/16 x 12-5/8 Weight lbs. 172 176 225 Airflow CFM 2682 2682 3741 Fan Motor Output and Quantity kw 0.20 x 1 0.20 x 1 0.070 X 2 Maximum Over Current Protection (MOP) A 25 35 35 Minimum Circuit Amps (MCA) A 16.5 29.1 29.1 Rated Load Amps (RLA) A 15.3 19.0 23.2 Compressor Type Type Daikin Swing Capacity Control % 14-100 VRV LIFE INDOOR CXTQ Model Name CXTQ24TASBLU CXTQ36TASBLU CXTQ48TASBLU CXTQ60TASBLU Power Supply 24VAC from gas furnace Nominal Tons 2 3 4 5 *1,*3 Cooling Capacity Btu/h (kw) 24,000 (7.0) 36,000 (10.6) 48,000 (14.1) 60,000 (17.6) *2,*3 Heating Capacity Btu/h (kw) 27,000 (7.9) 40,000 (11.7) 54,000 (15.8) 66,000 (19.4) Casing / Color Daikin Slate Gray Dimensions (H x W x D) in. (mm) 22-1/16 x 17-23/32 x 24-7/32 (560 x 450 x 615) 22-1/16 x 17-23/32 x 24-7/32 (560 x 450 x 615) 30-1/16 x 21-7/32 x 24-7/32 (764 x 539 x 615) 30-1/16 x 24-23/32 x 24-7/32 (764 x 628 x 615) Coil Type Cased Upflow/Downflow A-coil *4 Air pressure drop in w.g. 0.089" 0.240" 0.310" 0.329" Weight lbs (kg) 46 (20.9) 52 (23.6) 72 (32.7) 79 (35.8) Pipe Connections Liquid in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Gas in. (mm) 5/8 (15.8) 5/8 (15.8) 5/8 (15.8) 5/8 (15.8) Drain in. (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) Safety devices Refrigerant Control Connectible Outdoor Unit Fuse Electronic Expansion Valve R-410A VRV LIFE VRV LIFE 11

WARNINGS: >> Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. >> Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. >> Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. >> For any inquiries, contact your local Daikin sales office. ADDITIONAL INFORMATION Before purchasing this appliance, read important information about its estimated annual energy consumption, yearly operating cost, or energy efficiency rating that is available from your retailer. Daikin, VRV, and their designs, and all other trademarks used herein are owned by Daikin. 2017 CB-VRVLIFE 12-17