Premier Series Monitor

Similar documents
CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Beacon 800 Gas Monitor Operator s Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Carbon Monoxide Transmitter

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Temperature Controllers

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Analog Room Pressure Monitor RPC Series

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

RTD TEMPERATURE SENSING SYSTEM

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Beacon 110 Gas Monitor Operator s Manual

Low Temperature Zirconia Oxygen Analyzer

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

GLD-30 Gas Leak Detector

SCAN200E USER S MANUAL

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

INSTALLATION INSTRUCTIONS

CO2 & Oxygen Monitor Operating Instructions Model: RAD

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Pioneer-R16 Gas Monitor Operator s Manual

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

30.45 Electric Release PDRP-2001

Instruction Manual Series 17CA3000 Chloralert TM Plus Multi-Gas Detector CAPITAL CONTROLS

Operating Instructions

4800 Gas Controller User Guide

Mark 25 Ultrapure Water Conductivity Analyzer

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Oxygen / Carbon Dioxide Analyser / Transmitter. Model 1637

2-Channel Smoke Detector SD - 110

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

USER MANUAL FOR OPERATING SYSTEM

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Beacon 410A Gas Monitor Operator s Manual

Combustible Gas Detection and Control System

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Using the QRAE Plus personal multigas monitor

Oxygen & Carbon Dioxide Analyser

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

EXAMPLES OF HOW TO ORDER

Danfoss gas detection units

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

Oxygen & Carbon Dioxide Analyser

EXAMPLES OF HOW TO ORDER

QA16 Addressable System

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Flostop TS D7E and A8E. Operation Manual

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Flopurge TS. Operation Manual

Process Alarm Module RTA 421

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

INSTALLATION INSTRUCTIONS

RMS/RPX Reader. User Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SenSmart Universal Gas Detector Series

Danfoss gas detection unit Type GD Heavy Duty

Superdew 3. Hygrometer. Operating Instructions

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Operation & Maintenance Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Product Manual SZ1145

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Instruction Manual Model L2 RF Switch

Universal Gas Detector

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

ENMET 680 Fairfield Court Ann Arbor, MI Fax LC-8 Controller Operation and Maintenance Manual

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

ANALOX 3000 Carbon Monoxide Monitor

Process & TeMPerATUre UniversAl input DigiTAl MeTers

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

GA-180 Gas Detector. Operation and Maintenance Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Booster Power Supply Manual

Oxygen Monitor Operating Manual

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Transcription:

Premier Series Monitor GD000 GAS DETECTOR INSTALLATION AND OPERATION MANUAL IHPN 60600 EAGLE MICROSYSTEMS, INC. 66 Circle of Progress Pottstown, PA 9464 PHONE: 6050 FAX: 6004 copyright /0

Premier Series Monitor TABLE OF CONTENTS: SPECIFICATIONS: Page QUICK START: Installing, wiring and display operation. Page OPERATION: Main run screen, password entry screen and monitor setup screen. Page ALARM: Critical and danger screens. Page /4 CALIBRATION: Analog input (CH), Analog output (IOUT). Page 4/5 BATTERY BACKUP: Battery status Page 5 WIRING: Power, alarms, analog input and outputs Page 6 SPECIFICATION: Power Supply 5/0 VAC Switch selectable. Power Consumption W Display LCD, backlit, 6 characters by lines, 5mm character height, 5x8 character matrix. Pushbuttons Four, tactile dome. Relays Three, Mechanical (AC or DC) Buzzer. 0 DB Rating.A, 5VAC. Optional: 5A @ 50VAC. Analog Input two, 4 to 0mA. Analog Output Isolated 4 to 0mA, 0500ohm load, active. Digital Output 0mA Serial (remote computer) INSTALLATION: QUICK START ). Mount the Premier Series Monitor at eye level. Mount the sensor off the floor. The Premier Series Monitor is provided with of cable for the sensor. ). Attach the cable from the Premier Series Monitor to the sensor. The red LED will go on when powered up. ). The Premier Series Monitor requires 7VAC (/0%) power at 486Hz and /4 amp. IHPN 60600 After proper installation the monitor is ready to operate. DISPLAY: The top line of the LCD display is formatted to show a selected value along with its engineering units. The second line normally provides function labels for the four pushbuttons located below the function. The pushbuttons do not have any labels. Line: Value & units 4 copyright /0

Premier Series Monitor OPERATION: MAIN RUN SCREEN: The value displayed is the type of sensor and its scaled output in ppm. Below the sensor type and value is a fifty segment bargraph representation of the monitors full scale and the 4mA to 0mA output (PO). To enter the configuration and calibration screens press SET. The display will prompt you to enter a password. 4 SET Press SET to enter a password screen. SO 0.0 ppm IIIIIIIIIIIIIIIIIIIIIIIIII SET PASSWORD ENTRY SCREEN: From the run screen, press SET and the user will be prompted to enter a password (default is 000). If the password is correct, the MONITOR SETUP SCREEN will be displayed. If an incorrect password is entered, The MAIN RUN SCREEN will be displayed.?, 09 Steps from 0 to 9 and then back to 0.?, 09 Steps from 0 to 9 and then back to 0.?, 09 Steps from 0 to 9 and then back to 0. 4 ENT Press ENT to enter monitor setup screen.. ENTER PASSWORD??? ENT MONITOR SETUP SCREEN: From the Monitor Setup screen, you can select CAL, ALM or RUN. The Calibration screen provides the ability to calibrate the analog input and output. The alarm screen provides the ability to set the Danger and Critical values. CAL Enter calibration screen. ALM Enter danger and critical alarm setup screen 4 RUN Go back to the main run screen. MONITOR SETUP CAL ALM RUN Premier Series Monitor ALARM: SELECT ALARM: From the MONITOR SETUP SCREEN, press the pushbutton under ALM. CAL Enter calibration screen ALM Enter alarm select screen 4 RUN Go back to the main run screen MONITOR SETUP CAL ALM RUN copyright /0

ALARM SCREEN: Press the pushbutton under CRT or DGR, to configure. Press ESC to return. CRT Critical alarm screen to set value for relay contact. DGR Danger alarm screen to set value for relay contact. 4 ESC Go back to the monitor setup screen. SEL SO CH ALM CRT DGR ESC CRITICAL ALARM SETUP SCREEN: From the critical alarm setup screen you can view the current value. To change, press the pushbutton under UP or DWN to change the value. Press the pushbutton under SET to enter the new value and return back to alarm setup screen. UP To increase the value. DWN To decrease the value. 4 SET Go back to the alarm setup screen. DANGER ALARM SETUP SCREEN: From the danger alarm setup screen you can view the current value. To change, press the pushbutton under UP or DWN to change the value. Press the pushbutton under SET to enter the new value and return back to alarm setup screen UP To increase the value. DWN To decrease the value. 4 SET Go back to the alarm setup screen. CRITICAL 0.0 DANGER.0 Premier Series Monitor CALIBRATION: SELECT CALIBRATION From the MONITOR SETUP SCREEN, press the pushbutton under CAL. CAL Enter calibration screen.. ALM Enter alarm select screen. 4 RUN Go back to the main run screen MONITOR SETUP CAL ALM RUN CALIBRATION SCREEN: Press the pushbutton under CH or IOUT. Press ESC to return. CH Press to calibrate 40mA analog input.. IOUT Press to calibrate 40mA analog output. 4 ESC Will ask to set new password yes /no CALIBRATION CH IOUT ESC 4 copyright /0

CALIBRATE ANALOG INPUT CH SCREEN: A device generating a calibrated 40mA output is required. The current SET CH analog input is displayed in the top right of the screen. Use a calibrated analog input or other device to calibrate the zero and full scale value. ZRO SPAN ZRO Press to enter the value being input as the calibrated zero. SPAN Press to enter the value being input as the calibrated standard. 4 ESC Go back to the calibration screen. 0.0ppm ESC CALIBRATE ANALOG OUTPUT IOUT SCREEN: A DMM is required to proceed with calibration. Attach a DMM, press the pushbutton under 4mA or 0mA to enter setup screen. 4mA Press to enter 4mA setup screen. 0mA Press to enter 0mA setup screen. 4 EXIT Go back to the CALIBRATION screen. SET ANALOG OUT 4mA 0mA EXIT SET 4.0mA ANALOG OUTPUT: A DMM is required to proceed with calibration. While viewing the DMM, press the pushbutton under up or down to new value. Press the pushbutton under SET to enter the new value and return back to set analog output screen. UP Press to drive analog output up. View on DMM. DWN Press to drive analog output down, View on DMM. SET 4.00mA OUT 4 SET Press SET to enter the new value and return to SET ANALOG OUT screen. SET 0.0mA ANALOG OUTPUT: A DMM is required to proceed with calibration. While viewing the DMM, press thepushbutton under UP or DWN to new value. Press the pushbutton under SET to enter the new value and return back to Set Analog Output screen. UP Press to drive analog output up. View on DMM. DWN Press to drive analog output down, View on DMM. SET 0mA OUT 4 SET Press SET to enter the new value and return to set analog output screen. Premier Series Monitor BATTERY STATUS: MAIN RUN SCREEN: If the monitor is equipped with the battery backup option the battery status can be displayed from the main run screen. To display battery status depress # BATTERY STATUS pushbutton. When pressed the battery status will be displayed for 0 sec. E IIIIIIIIIIIIIIIII After 0 sec. The display will revert to the Main Operate Screen. Press to display battery status. In battery power mode, hold to power down. 4 F 5 copyright /0

EAGLE MICROSYSTEMS. INC. Premier Series Monitor WIRING: TERMINATIONS: F FUSE TB5 G N H TB4 SW motor 4 PS000 K K K K4 4 5 6 7 8 TB K K K K4 5 COM Tx Rx TB 40mA P0 9 A B V 40mA mv SCR PV PV CELL THRM TB PASS POWER: AC POWER TB5 G N H TB5 G N H GROUND NUTERAL HOT ALARMS: TB 4 5 6 7 8 K K K K4 FAILURE K4 CRITIAL K CRITIAL K DANGER K TB (8) (7) (6) (5) (4) () () () H N INPUT: TB V SCR 40mA mv PV PV CELL ANALOG OUTPUT: A B THRM 9 SCR V PV PV TB () () () (4) (5) 5 COMTx Rx 40mA P0 TB TB PO () 40mA OUTPUT <= 500Ω () 6 copyright /0