Fire Protection for Printing Machines with High Pressure Water Mist

Similar documents
Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Fire protection on chemical manufacturing sites

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Approved products and systems for water mist systems and VdS 3188 for planning and installation

Fire Extinguishing Concepts for Recycling Plants. 1 Fire Extinguishing Concepts for Recycling Plants

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

IMPROVING VENTILATION AND PASSIVE PROTECTION WITH FFFS

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Innovative Solutions for Active Fire Protection in Road/Rail Tunnels and Underground Facilities

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

Fixed fire protection solutions

CO 2 Fire Extinguishing Systems

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Water Mist and Heritage Buildings Case - St. Mark s Dome, Venice

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London,

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Fire Protection Systems For Railway Vehicles WE ARE ENSURING FIRE SAFETY

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

AUTOMATIC FIRE EXTINGUISHING SYSTEM for TUNNEL PROTECTION with SPREAD REMOTE CONTROLLED MONITORS (TUDEM-LEGIO)

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Making sense of risk Risk engineering. Metalworking operations

WATER MIST CONVENTION AND EXHIBITION

THE EFFECT OF A WATER MIST SYSTEM ON LARGE-SCALE TUNNEL FIRES

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

UCL FIRE EXTINGUISHER SCALING & LOCATION POLICY

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

THE FUTURE OF FIRE SUPPRESSION

MORE THAN JUST FIRE PROTECTION

4 August Islington Fire Protection Transpower NZ Limited

The Science Behind Water Mist Protection of Typical Building Hazards

The first tunnel fire. Benefits of fire

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Sprinklers in Europe known problems and misconceptions. Alan Brinson

LaserFOCUS VLF-250 Engineering Specification

High flying fire protection HI-FOG for aircraft hangars

designed for rail 5000 Series

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

Fire and Extinguishing Tests on Computer Equipment

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Experts in Fire Protection

XFlow water mist system preserves and enhances productivity at a TULIP Sausage factory in Svenstrup Denmark.

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Sprinkler systems. A presentation for fire brigade staff

Fire Protection Guidelines for Handling and Storing PRB Coal

and Sprinkler System in Resalat Tunnel of Tehran

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

FAÇADE FIRE TESTS Towards a new European standard method

Fire Safety Awareness Training START

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

WATER SPRAY EXTINGUISHING SYSTEMS

RIM SEAL SYSTEMS E-BOOK

UL268 7 th challenge with single infrared smoke detector

Tel Web: dyayan.com

Local area fire protection using automatic suppression

Heat Interface Units for decentralised water heating in district heating systems

MORE THAN JUST FIRE PROTECTION

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

Emergency shutdown systems. Procedures for bypassing ESD s

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Experts in Fire Protection

Fire protection for buildings

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

CFD Simulation of the Water Mist Effect on Fire

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

PRINCIPLES OF DESIGN SPRINKLER INSTALLATION FOR FIRE FIGHTING IN THE UNDERGROUND GARAGES AND SUPPLEMENTARY LEGAL ACTS

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

An experimental study of the impact of tunnel suppression on tunnel ventilation

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Procedure for the Approval of New Fire Detection and Alarm Technologies

Workplace FIRE SAFETY

Sprinklers Modeling for Tunnel Road Fire Fighting

Local area fire protection using automatic suppression

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Approval of water mist systems in buildings

Development of a European approach to assess the fire performance of facades

Transcription:

Fire Protection for Printing Machines with High Pressure Water Mist Dipl.-Ing. Rüdiger Kopp FOGTEC Fire Protection ruediger.kopp@fogtec.com 1

Case Study PRINOVIS Printing Company - PRINOVIS is Europe s largest printing company with 2800 employees and various factories in Germany and UK - PRINOVIS is specialized in top quality full colour print of magazines, catalogues and brochures - The printing factory in Dresden (Germany) utilizes retro-gravure printing machines for highest printing finish results - Fast and flexible reaction to end customer s needs are an important performance characteristic of PRINOVIS - Fire protection has always been an important aim to ensure a safe environment for its employees and business continuity 2

Case Study PRINOVIS Printing Company - The PRINOVIS site in Dresden (Germany) operates 6 large retro-gravure printing machines in a hall of 120 m x 60 m - Each machine has an overall enclosure of 8 m x 30 m with 10 m of height - The existing fire protection concept has been developed in close co-operation with the insurance company and the fire brigade - The fire risk has been assessed to the paint trays containing solvent based colours - These have been protected with an automatic local protection system utilizing Aerosol - A manually activated local protection CO 2 system has been installed as back-up 3

Case Study PRINOVIS Printing Company - On 19.05.2013 at 14:00 the fire station of Dresden received an alarm call for fire at the PRINOVIS factory - When the fire brigade arrived to the site one of the retro-gravure printing machines was fully on fire - Fire control was difficult due to spillage of solvent throughout the printing machine - The fire was extinguished after 2 hours by 116 firemen and 25 fire fighting vehicles, utilizing 7000 l of water with 600 l of foam additive - For smoke ventilation positive pressure ventilation was employed - Soot particles have settled in the entire hall on all surfaces and required thorough cleaning measures - Extensive water damage to stored paper material - Total loss of the retro-gravure printing machine on fire with eight-digit Euro figure overall damage 4

Case Study PRINOVIS Printing Company 5

Case Study PRINOVIS Printing Company - Investigations after the fire could not determine the exact reason for the rapid fire spread throughout the printing machine - Most likely the solvent based colours on fire spread from the paint trays to not protected areas and ignited the paint mixing containers - In conjunction with the insurance company, PRINOVIS decided to improve fire protection measures within the retro-gravure printing machine enclosures - Beside improvement of the automatic fire detection system different fire fighting systems were evaluated - An extension of the CO 2 system was no option due to personnel safety Water mist was identified as optimal fire fighting system for the fire risk 6

Benefits of High Pressure Water Mist High pressure water mist technology was selected to be most favourable due to: - Fire test proof of extinguishing effect - Safe for personnel - No requirements for pre-warning times - Best cooling abilities with smallest water amounts (lowest damage potential) - Low impact to electric components - Simple system retrofit to the existing machines and to the periphery - Lowest business interruptions 7

Case Study PRINOVIS Printing Company Development of a fire protection concept in cooperation with: - Client (PRINOVIS) - Insurance company (HDI) - Fire brigade - Water mist system manufacturer (FOGTEC) - Fire test laboratory (IFAB) - System acceptance body (VdS) Full scale fire tests were defined based on Annex B of CEN TS 14972 defining: - Fire load - Arrangement of fire load - Ventilation conditions - Acceptance criteria 8

Fire Tests for Printing Machine Protection Fire Test Arrangement - Fire test hall with 10 m x 15 m floor area and 5 m ceiling height with 2 m x 3 m door opening - Dimensions of the fire test mock-up equivalent to the dimensions in the real printing machine - Natural ventilation conditions by open doorway in the fire test hall System Acceptance Criteria - Fire extinguishment within 15 minutes of system discharge 9

Fire Tests for Printing Machine Protection Fire Loads - n-heptane was chosen as representative fire load for solvent based colours containing Toluene as solvent - Diesel was chosen as representative fire load for lubricants - Original paper rolls Fire Load Arrangement - n-heptane pool fire of 2,5 m x 0,8 m to simulate spilled solvent based colours - n-heptane pool fire of 2,0 m x 0,6 m to simulate spilled solvent based colours - Diesel pool fire of 2,0 m x 0,6 m to simulate spilled lubricants - n-heptane spray fire to simulate ruptured solvent based colour supply (8 bar; 2,84 l/min) - Diesel spray fire to simulate ruptured lubricant supply (90 bar; 2,84 l/min) 10

Fire Tests for Printing Machine Protection Mock-up - Mock-up simulates the space between two printing units, the paint mixing units at one side of each printing unit and the gears at the other side of each printing unit Instrumentation - Thermocouple TE 1, TE 2 and TE 3 to monitor extinguishment of pool fire 1 - Thermocouple TE 5, TE 6 and TE 7 to monitor extinguishment of pool fire 2 - Thermocouple TE 9 to monitor extinguishment of the spray fire - Thermocouple TE 4 and TE 8 to monitor the temperature at the position of the linear heat detection cable 11

Fire Tests for Printing Machine Protection Scenario 1 Combined shielded pool fire and spray fire with n-heptane to simulate a rupture of a solvent based colour supply and a spillage of solvent based colours at a paint mixing unit Water Mist System - Open water mist nozzles arranged as object protection along the printing machine - 5% AFFF additive Activation When reaching temperature of 70 C at position of linear heat detection cable (+ 50% safety) 12

Fire Tests for Printing Machine Protection Scenario 1 Combined shielded pool fire and spray fire with n-heptane to simulate a rupture of a solvent based colour supply and a spillage of solvent based colours at a paint mixing unit Fire Test Results - Pool fire extinguished at 32 sec of system discharge - Spray fire extinguished at 9 min 24 sec of system discharge 13

Fire Tests for Printing Machine Protection Scenario 2 Pool fire with n-heptane to simulate a spillage of solvent based colours between two printing units Water Mist System - Open water mist nozzles arranged as object protection between the printing units - 5% AFFF additive Activation When reaching temperature of 70 C at position of linear heat detection cable (+ 50% safety) 14

Fire Tests for Printing Machine Protection Scenario 2 Pool fire with n-heptane to simulate a spillage of solvent based colours between two printing units Fire Test Results - Pool fire extinguished at 28 sec of system discharge 15

Fire Tests for Printing Machine Protection Scenario 3 Combined shielded pool fire and spray fire with Diesel to simulate a rupture of a lubricant supply and a spillage of lubricant at the gear of a printing unit Water Mist System - Open water mist nozzles arranged as object protection along the printing machine - No additive Activation When reaching temperature of 70 C at position of linear heat detection cable (+ 50% safety) 16

Fire Tests for Printing Machine Protection Scenario 3 Combined shielded pool fire and spray fire with Diesel to simulate a rupture of a lubricant supply and a spillage of lubricant at the gear of a printing unit Fire Test Results - Pool fire extinguished at 5 min 58 sec of system discharge - Spray fire extinguished at 7 min 48 sec of system discharge 17

Fire Tests for Printing Machine Protection Scenario 4 Paper fire to simulate an accumulation of paper within the printing machine Water Mist System - Open water mist nozzles arranged as object protection along the printing machine - No additive Activation When reaching temperature of 70 C at position of linear heat detection cable (+ 50% safety) respectively 90 sec after ignition 18

Fire Tests for Printing Machine Protection Scenario 4 Paper fire to simulate an accumulation of paper within the printing machine Fire Test Results - Paper fire extinguished at 1 min 36 sec of system discharge 19

Case Study PRINOVIS Printing Company Protection Concept - Improvement of existing Aerosol local protection systems in the paint trays of the five remaining printing machines with a high pressure water mist system in three layers within the machines - Deluge system with nozzle layout based on full scale fire test results (560 open nozzles) - Subdivision of each retro-gravure printing machine into 4 water mist sections via 4 section valves, whereby only one section is discharging water mist with 5% AFFF additive (20 section valves) - Integration of manual water mist fire fighting guns in wall cabinets for use by trained printing machine operation personnel (2 FOGGUN wall cabinets) - Fire detection by linear heat detection throughout the printing machine 20

Case Study PRINOVIS Printing Company System Layout within Printing Machine 21

Case Study PRINOVIS Printing Company Protection Concept - Small bore stainless steel pipework can ideally be retrofitted to the printing machines without extensive business interruptions - Jockey pump to prefill main pipe from pump unit to decentralized section valves - Safety concept foresees simultaneous activation of one complete retro-gravure printing machine and one water mist fire fighting gun - Centrally located independent water mist system pump unit with 8 x 120 l/min at 120 bar - AFFF injection unit at the high pressure pump unit - Water mist system supplied by fresh water from a 29 m 3 tank assuring 30 minutes autonomy - AFFF storage tank for 60 minutes autonomy 22

Conclusion High pressure water mist has demonstrated excellent extinguishing abilities for printing machine environment PRINOVIS and their insurance company are very satisfied with the achieved results, assuring best possible fire protection to their assets 23

Thank You for Your Attention 24