Bryant Evolution Connex Control (SYSTXBBECC01-B) Occupancy Sensing Sequence of Operation

Similar documents
Honeywell ENERGY SAVINGS KIT

Residential Smart Thermostat Qualified Products List Updated 5/1/2017

Advanced Installation and Configuration Instructions

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

abode Web app Functionality

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Sensors Explained AUTOMATION

User Guide ecobee ecobee 477 Richmond St West 2nd Floor, Toronto Ontario M5V 3E7 Canada Toll free

Model: Touch-RF. 1 Wireless Series

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Lyric T6 & T6R Smart Thermostat

Infrared Ceiling Mount Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

ATC32U03 igate Communicating, Programmable Thermostat

Document # R01

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Wiser Air User Interface Guide. Thermostat

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

CERV WIRELESS TOUCHSCREEN CONTROLLER USER S MANUAL BUILD EQUINOX REVISION N. HIGH CROSS RD. URBANA, IL

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Evolution Control. Zone Control Homeowner s Guide

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Digital Thermostat Models: VS30W and VS30B

Model: Slimline-RF. 1 Slimline Series

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

ComfortSense 7500 Commercial Thermostat. User Guide

, ,

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Integrated PIR detectors

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information

Fan Coil Unit (FCU) Application Guide

SMUD PowerStat Pilot. Energate Smart Thermostat User Guide. Powering forward. Together. SM

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Installation Guide. Ceiling PIR Detector (311) Features and Connections

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Manual SZ1022/SZ1031/SZ1035/

H&T Household Thermostat Design Introduction

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Infrared Ceiling Mount Sensor

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PIR Application Guide for the for VT76xxX5x00(X) Series thermostats (Issue Date: November, 2015)

SHARP. Multi Sensor User s Guide. Model: DN3G6JA069

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

Natural Ventilation Controller with 24vDC drive NVC-1204

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Product Manual SZ1009

Determining occupancy with motion sensing

ATC32U01 igate Communicating, Programmable Thermostat

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Installation Instructions

Installation Instructions

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

4 Wiring Brochure Wiring and

User s Manual

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

VT8600 Series Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

EBMHS (standard & slim-line PSU)

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

Elegance. SMT-700 User manual. Ver

Wireless Thermostat (WTS10) Keypad Operation Guide

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

USER S INFORMATION MANUAL

Infrared Wall Mount Occupancy Sensor

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

EBDSPIR-PRM-LV Product Guide

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

Natural Ventilation Controller with 24vDC drive NVC-1204

- Data Brochure Boiler Control 274

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Welcome to smarter living. New Resident User Guide

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

CONTENTS. Installation Guide. VT7200 Series

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

Transcription:

For Software Versions 1.1, 1.2 Integrated motion sensor allows the system to make automatic set point changes, based on occupancy, to provide the optimum home comfort and energy savings. For Software Versions 1.3 and later Integrated motion sensor allows the system to make automatic Activity changes, based on occupancy, to provide the optimum home comfort and energy savings. Motion sensor The on-board PIR motion sensor is placed on the bottom left corner of the Connex Control. It is able to detect motion at least 25 feet directly in front of the sensor, and within 135 cone perpendicular to the wall. The motion detection pattern is shown as below. Detection of motion happens as a person moves from one detection cone to the next. The closer to the control, the less lateral motion is required to detect motion; further away requires more lateral motion. Motion sensor The on-board PIR motion sensor is placed on the bottom left corner of the Connex Control. It is able to detect motion at least 25 feet directly in front of the sensor, and within 135 cone perpendicular to the wall. The motion detection pattern is shown as below. Detection of motion happens as a person moves from one detection cone to the next. The closer to the control, the less lateral motion is required to detect motion; further away requires more lateral motion. Page 1 rev20171106

Occupancy Status Indicator is available on the Home and Main screens on the Connex Control and Client Apps. When no movement is detected, the Occupancy Status indicator stays GRAY. When movement is detected, but the system hasn t yet determined that the space is occupied (for example, someone is just walking through the room), the Occupancy Status indicator turns BLUE. When the system determines that the space is occupied, the Occupancy Status indicator turns GREEN. Occupancy Status Indicator is available on the Home and Main screens on the Connex Control and Client Apps. When no movement is detected, the Occupancy Status indicator stays GRAY. When movement is detected, but the system hasn t yet determined that the space is occupied (for example, someone is just walking through the room), the Occupancy Status indicator turns BLUE. When the system determines that the space is occupied, the Occupancy Status indicator turns GREEN. The Occupancy Sensing feature can be enabled or disabled by the installer. Occupancy sensing is disabled from the factory. The Occupancy Sensing feature can be enabled or disabled under the sensors icon. Occupancy sensing is set to enabled from the factory. Page 2 rev20171106

Enabling and Disabling Occupancy Sensing Step 1: Go to menu on the home screen and press sensors icon. For non-zoning systems: Step 2: Press home occupancy setup. Step 3: Enable or disable Occupancy Sensing feature. NOTE: The default setting is enabled. Page 3 rev20171106

For zoning systems: NOTE: The motion/occupancy sensor on the main system control/thermostat is the sensor used for occupancy control in all zones. If the location of this sensor does not provide a good indication of occupancy for a particular zone, disable Occupancy Sensing for that zone. Step 2: Press zone occupancy setup. Step 3: Enable or disable Occupancy Sensing feature. NOTE: The default setting is enabled. NOTE: When Occupancy Sensing is disabled for a zone, occupancy detection has no effect on the scheduled activity settings and set points for that zone. Page 4 rev20171106

How does the Occupancy Sensing feature work? A passive infrared (PIR) motion sensor detects motion events. System control counts the number of motion events within a defined period of time to determine if the space is occupied, versus someone simply walking through the room. The Occupied state sustains for one hour to account for stillness in the room while occupied. When the Occupancy Sensing feature is enabled, automatic set point changes to HOME activity set points are activated when the space is occupied, regardless of scheduling feature being enabled or disabled. How does the Occupancy Sensing feature work? A passive infrared (PIR) motion sensor detects motion events. System control counts the number of motion events within a defined period of time to determine if the space is occupied, versus someone simply walking through the room. The Occupied state sustains for two hours to account for stillness in the room while occupied. The Occupancy-sustain timer is reset to two hours each time occupancy is again detected for that space. What happens when the space is unoccupied during a scheduled Home or Wake activity? When the Occupancy Sensing feature is enabled, the current scheduled activity is HOME or WAKE, and timing is per schedule, the activity and set point(s) change to AWAY automatically when the space is determined to be Unoccupied. NOTE: The Activity indication does not change, only the setpoint indication. Page 5 rev20171106

What happens when the homeowner returns home earlier than planned? When Occupancy Sensing feature is enabled, the current scheduled activity is AWAY or VACATION, and timing is per schedule, the activity and set points change to HOME automatically when the space is determined to be Occupied. SLEEP Activity If the space is determined to be Unoccupied at the beginning of a period where the current scheduled activity is SLEEP and timing is per schedule, the system will remain in the Unoccupied/Away status. If the zone is determined to be Occupied at the start of the scheduled SLEEP activity, or becomes Occupied at any time during the scheduled SLEEP activity, the activity will enter and stay in SLEEP mode until the sleep period ends, even if the room is determined to be Unoccupied afterwards. Page 6 rev20171106

NOTE: The Occupancy status indicator will continue to indicate whether the space is determined to be Occupied or Unoccupied in the SLEEP activity. HOLD/HOLD UNTIL Any HOLD UNTIL activity will automatically disable Occupancy sensing Activity changes/overrides. Once normal scheduling is resumed, Occupancy sensing will follow the Enabled/Disabled selection set by the user. Page 7 rev20171106

Whole House Activity The all zones HOME or all zones AWAY activity will override Occupancy sensing Activity changes/overrides. Once normal scheduling is resumed, Occupancy sensing will follow the Enabled/Disabled selection set by the user. Page 8 rev20171106