Dual certification! Air handling units for potentially explosive atmospheres

Similar documents
OPTIBAR DP 7060 Supplementary Instructions

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

UL HAZARDOUS LOCATIONS SERVICES

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Compact. Efficient. TROX.

Compact. Efficient. TROX.

Air distribution for clean rooms. Clever and flexible.

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Overview of Hazardous Locations as They Relate to Solenoid Valves

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OPTIWAVE X500 Supplementary Instructions

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Explosion-protected actuator Page 259 of 292

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Fire dampers. For diverse applications

Beamex. Calibration White Paper. Calibration in hazardous areas

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

INSTRUCTION MANUAL (ATEX / IECEx)

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

ATEX, NOMENCLATURE AND CODING

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Guide for hazardous areas

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

OPTIBAR P 1010/2010 C Supplementary instructions

Electrical Installations Design, Selection, Erection and Inspection

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Beamex Calibration White Paper. Calibration in hazardous areas

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

ATEX Explained A brief Introduction

INSTRUCTION MANUAL (ATEX / IECEx)

1. GENERAL TECHNICAL INFORMATION

Multipoint temperature sensor

INTRINSICALLY SAFE LIGHTING RANGE

THE BELGIAN PIONEER IN GAS DETECTION

ATEX, NOMENCLATURE AND CODING

Technical Data. Dimensions

manual addendum DELPHI Ex

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

TRASCO ATEX Couplings

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

ANNEX GD-CERT-EX-EN SIT

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Explosive. Atmospheres. Safety and Reliability

The innovative air handling unit. By TROX.

K*, R* Ventilation grilles

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Inductive slot sensor

THE BELGIAN PIONEER IN GAS DETECTION

Technical Data. Dimensions

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

VSD AND SS DRIVING ATEX MOTORS February 2014

Guide to Hazardous Location Approvals:

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

AIR HANDLING UNITS MANDÍK

Technical Data. Dimensions

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Implementation of ATEX Guidelines

Manual Power relay SR853

ATEX Safety Switches. More than safety.

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

IECEx Certificate of Conformity

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

[ TECHNOLOGY ] and does this definition affect a burner.

ARGENTA ATEX For potentially explosive atmospheres. ARGENTA ATEX Technical Specifications Wall-mounting cabinets. ARGENTA ATEX Certifications

EU DECLARATION OF CONFORMITY

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

PEPPERL+FUCHS GmbH

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Certificate of Compliance

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Intrinsically Safe Solutions

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Switches compliant with ATEX directive

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

EtherCAT Box Modules (EPxxxx-xxxx)

Certificate of Compliance

IECEx Certificate of Conformity

VERSAFLOW VORTEX Supplementary instructions

Transcription:

Dual certification! Air handling units for potentially explosive atmospheres

X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to both electrical and non-electrical equipment as well as to protective systems intended for use in potentially explosive atmospheres. It also applies to safety devices, controlling devices and regulating devices that are intended for use outside potentially explosive atmospheres, but are required for or contributing to the safe functioning of equipment and protective systems with respect to the risks of explosion. This is why we focus on these factors: Risk assessment Basic health and safety requirements for the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres Definition of equipment category Type certification and declaration of conformity Quality assurance by means of a QM system Providing the declaration of conformity and equipment documentation Clear labelling of the AHU To ensure conformity of our explosion-proof products, we manufacture our X-CUBE Ex units in compliance with ISO IEC 80079-34. And we don't stop there: We also have conformity to our QM system tested and certified by an independent institute. TROX is in fact the only manufacturer to offer this dual certification. 3

ATEX For when danger is in the air ATEX (ATmosphères EXplosibles, or explosive atmospheres) In certain locations or with certain conditions, even air can present a hazard. If flammable gases, mists or vapours, or combustible dusts mix under atmospheric conditions with air, an explosive atmosphere may result. In such a case it needs only a small source of ignition, such as a spark, friction, heat or electrostatic discharge, to cause an explosion. TROX X-CUBE Ex AHUs for ATEX Air handling units installed in areas with potentially explosive atmospheres have to comply with ATEX directive 2014/34/EU. X-CUBE Ex units have been specially developed for zone 1 and zone 2 areas with potentially explosive atmospheres; in addition, they meet the requirements for groups IIA and IIB of explosive materials and of temperature classes T1 to T4. X-CUBE Ex units are configurable and suitable for the ventilation of individual rooms or buildings with volume flow rates of up to 86,000 m 3 /h. The type and number of the actual components for air treatment, such as filters, heating and cooling coils, humidifiers, dehumidifiers and heat exchangers for heat recovery, depend on the individual project requirements, but will be ATEX-compliant in any case. Outstanding quality and efficiency Type X-CUBE units have been designed to the highest standards of quality and energy efficiency. Construction, insulation, leakage values, heat recovery and energy-efficient motors allow for a significant savings potential. Energieeffizienzklasse A+ nach RLT-Richtlinie 01 Raumlufttechnische Geräte Herstellerverband e.v. 2

X-CUBE and ATEX ATEX explained ATEX directive 1999/92/EC describes the minimum requirements for system owners to improve the safety and health of workers potentially at risk from explosive atmospheres. With ATEX directives and industrial health and safety regulations, owners of systems in potentially explosive atmospheres, such as in the petrochemical and chemical industries, or in power plants and waste disposal operations, have to comply with special safety guidelines. This may seem daunting, but we will gladly help you select the unit that best suits your requirements. AHU selection table Configuring an air handling unit for your project can be difficult, which is why we have developed a selection table that guides you through the relevant steps so you won't forget any important details. Just download the table from www.trox.de/ahu-atex. We then use your data to design a project-specific, ATEX-compliant ventilation strategy with a bespoke X-CUBE configuration. II 2G Ex h IIC T6 Gb Classification system Zone 0 Zone 20 Zone 1 Zone 21 Zone 2 Zone 22 Mining Hazardous explosive atmosphere Continuously, frequently or for long periods Occasionally Infrequently and for short periods only Equipment category 1G 1D 2G 2D 3G 3D M1 and M2 Type of protection Constructional safety: c Standard symbol Zone Main areas of application Standard h 0, 1, 2, 20, 21, 22 Areas with pot. explosive gases temperature classes 450 C T1 300 C T2 200 C T3 135 C T4 100 C T4 85 C T6 Areas with pot. explosive dusts surface temperature T... C (e.g.: T 80 C) Clutches, pumps, gears, conveyor belts ISO 80079-37 EN ISO 80079-37 Mining areas with potentially explosive atmospheres Group I Methane Areas with potentially explosive gases Group II IIA IIB IIC Areas with potentially explosive dusts Group III IIA IIB IIC Propane Ethylene Hydrogen Combustible flyings Non-conductive dust Conductive dust Classification system Zone 0 Zone 20 Zone 1 Zone 21 Zone 2 Zone 22 Mining EPL (IEC/EN 60079-0) Ga Da Gb Db Gc Dc Ma and Mb ATEX marking Type of protection Group Max. surface temperature EPL Our selection table for ATEX-compliant air handling units is available for download from www.trox.de/ahu-atex 4

Quality made in Germany: TROX X-CUBE Ex A TROX X-CUBE is a convincing product, and this includes ATEX units. They are configurable, and their energy efficiency is unparalleled. X-CUBE units are manufactured in an ultra-modern production facility in Germany that was specially built for X-CUBE production. TROX X-CUBE Ex comes in three versions: there is a standard version for indoor installation, a weatherproof outdoor version and a particularly hygienic version for sensitive areas. Extensive testing and quality assurance Each individual X-CUBE Ex unit is subjected to rigorous tests before shipping. Conformity of both the product and the production process are examined regularly by a notified body. Casing properties to EN 1886 certified by TÜV Süd, Germany Leakage class L1 (M) Mechanical strength class D1 (M) Filter class up to F9 (M) Thermal transmittance class T2 Thermal bridging class TB2 3 1 5 6 4 1 Multileaf dampers and actuators - ATEX-compliant construction - Leakage class 2 to EN 1751, class 4 as an option - Brass bearings, stainless steel as an option - Linkage and opposed action blades - Optional: ATEX actuators including spring return and auxiliary switch 2 2 3 Earthing The base frame, the entire skeleton of the unit as well as all panels and metal parts are earthed. Duct connection - Flexible connector made of electrostatic dissipative (anti-static) fabric, with equipotential bonding - Fulfils the hygiene requirements of VDI 6022 - Prevents the transmission of vibration 5

9 Sound attenuator Perforated plates cover the mineral wool infill in splitters (option L) and prevent both abrasion and electrostatic discharge. 8 Droplet eliminator - Entirely metal - Included in the earthing system - Easy-to-clean aluminium fins 5 7 Fans - High-performance centrifugal fans - Efficiency class IE2 (EU classification) - PTC resistor for motor protection - IEC standard motors, 'flameproof enclosure' type of protection 7 3 - Explosion-proof construction according to equipment group II, equipment 9 8 category 2G, group IIB of explosive materials, temperature class T4 6 Filters - ATEX-compliant pocket filters and Mini Pleat filters - Filter classes M5 to H13 - Mini Pleat filters with lightweight, anti-static plastic frames - Powder-coated filter mounting frame, stainless steel as an option 4 5 ATEX-compliant inspection window - Meets the requirements of ISO 80079-36 - Clear size 190 x 190 mm ATEX-compliant attachments ATEX-compliant lighting elements, light switches, local isolators, differential pressure measuring devices and frost protection sensors. 6

Design for safety Perfect unit configuration You want an air handling unit that runs safely and efficiently. This is what counts. The key? Configuration! It is particularly important to avoid zonal dispersion, so we do consider the input of specialist consultants, installers and system owners regarding zones and other aspects of explosion protection. These are the critical factors: Zones inside and outside of the air handling unit Type of explosive gas Temperature class Efficiency, however, requires that some additional factors are considered, too: Type of heat recovery Installation location Air change rate in the installation space (for indoor units) Nearby buildings or walls (for outdoor units) Unobstructed airflow in two directions along an axis (for outdoor units) AHU operating time Variants for Ex zones (according to AHU guideline 02) V1 inside: 3G outside: n.r. V2 inside: n.r. outside: 3G V3 inside: 3G outside: 3G V4 inside: 2G outside: 3G V5 inside: 3G outside: 2G V6 inside: 2G outside: 2G V7 inside: 2G outside: 3G (0.5 m), beyond 0.5 m: n.r. V8 inside: 3G outside: n.r. V9 inside: 2G outside: n.r. n.r. Zone 1 (explosive atmosphere occurs occasionally) Zone 2 (explosive atmosphere occurs infrequently) No zone (n.r. = no requirement) Variants V1 to V7 = indoor installation Variants V8 V9 = outdoor installation 7

TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn, Germany Phone +49(0)2845 2020 Fax +49(0)2845 202265 www.troxtechnik.com trox@trox.de TROX GmbH (11/2017) SF/2017/11/X-CUBE-Ex/DE/en Subject to change All rights reserved