RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

Similar documents
The Right Temperature, Always THS Series Modular Thermostats

SACE PR021/K SIGNALLING UNIT

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

Operation and use. Functions and characteristics

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

RE-PR3-E-27 3-Phase Panel Mount 27kW

REA 105 Arc Protection Module. Operator s Manual

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

1.Application. 2.Main Technical Specifications B-10

02/11/2015

Welcome to Hager Presentation

VAMP 120 & 121. Arc flash detection units. Product picture

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Moulded Case Circuit breakers

DTA. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Outdoor compact dual IR perimeter detector

02/11/2015

M15051) INSTRUCTION MANUAL

03.03.mmm REV.2 09/01

MO n : 12JMC rév A

ACS-30-EU-EMDR- 10-MOD

Installer manual ELK 213 Immersion heater

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

CTT8 TEMPERATURE MONITOR DEVICE

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Moulded case circuit brakers

DANFOSS OPTYMA PLUS INVERTER UNITS

Residual Current Devices

Data sheet. Function description. Benefits

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Molded Case Circuit Breakers, Bulletin 140G

QA(13) - Series Miniature Circuit Breakers

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Ordering Key. Dielectric strength

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Monitoring Devices 11/1

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

Insulation fault evaluator EDS460-DG

1.7. Insulation fault evaluators EDS460/490 EDS461/491

FLAME AMPLIFIER MODULE 3001

Analog Annunciator Unit SACO 16 A3. Product Guide

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

SCHMIDT LED Measured Value Display MD Instructions for Use

Operating Manual RCM420

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

VAMP 121. Arc protection unit. User manual

Operating Manual TR600

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

M2000 Engine Controller

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

X803 ELECTRONIC CARD Control unit for generating sets OPERATING MANUAL

Differential relays 4.01

M2500 Engine Controller Installation Manual

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

TCM-2 Thyristor Control Module DATA SHEET

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Room thermostats with LCD for wall mounting

Integrated Solutions Low Voltage Systems

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

HTC-915-CONT. Heat-Trace Control system

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

Mylos Ultra Choosing is pure artistic expression

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

using D Doepke » residual current display using 10x LED display» Residual current Transformer» Adjustable pre-alarm» Applications up to 630 A

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Process Alarm Module RTA 421

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

* Consult factory on conditions for approval acceptability

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

PHOTOELECTRIC AMPLIFIER SERIES

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Transcription:

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers 2CSC444001B0201

RD3 and RCQ020 A unique and complete range for residual current protection ABB offers a complete range of electronic residual current devices, in accordance with the international Standard IEC604-2, Annex M. The perfect combination of RD3 and RCQ020 range with miniature circuit-breakers of S200 family and Tmax moulded-case circuitbreakers ensures residual current protection up to 0A. RCQ020 can be also be combined with Emax X1. 2

RD3 and RCQ020 residual current devices are combined with a wide range of toroids with diameter from 2mm to 230mm (for cables and busbars), which provides the maximum application fl exibility for an effective protection in every point of the system. 3

RD3 and RCQ020 A complete range of residual current devices for industrial applications With the residual current devices with separate toroid, either in modular version (range RD3) or controlled from the switchboard front (range RCQ020), ABB provides the right solution for residual current protection for all levels of low-voltage installations, from low-voltage lines to power distribution, up to terminal distribution. These high-performance products provide: The benefits Reduction of unwanted tripping Protection and control Total selectivity of the system Power supply from auxiliary network Flexibility of installation High accuracy of measurement Frequency fi ltering 4

Reduction of unwanted tripping RD3M, RD3P and RCQ020 residual current devices perform leakage current measurement through a frequency filtering that allows an increased immunity against high-frequency currents not hazardous to man that are typically generated by inverters and the main cause of unwanted tripping of residual current devices. Moreover, some of the models of RD3 range and RCQ020 switchboard device feature a pre-alarm threshold adjustment that signals, through an output contact, when a given residual leakage current is reached. This function indicates that the installation insulation level is decreasing and therefore allows appropriate planning of the required maintenance operations. By removing most of the unwanted tripping of residual current devices, a high degree of safety on the systems can be reached, along with a high level of service continuity. Protection and control in every point of the system Due to the wide current adjustment range (from 30mA to 30A) and to the large number of toroids available (openable and closed for cables or busbars), RD3 and RCQ020 residual current devices ensure effective protection in every point of the system. Total selectivity of the installation By combining the wide time-adjustment options and the countless release features of ABB low-voltage circuit-breakers, different levels of selectivity can be obtained ensuring total selectivity in case of an insulation fault in the system. Power supply from auxiliary network The power supply of RCQ020 residual current devices from an auxiliary network provides great flexibility to the user. Flexibility of installation As the devices are available either with miniature design (RD3 range 3 modules) or as switchboard devices (6mm x 6mm), the new range allows the installation of any type of switchboard. High accuracy of measurement Both RD3 range and RCQ020 devices perform the RMS measure of earth leakage current. This means that the residual current devices measure any type of signal, calculating the actual RMS value, averaged according to the frequency filtering. Frequency filtering The measurement of leakage current provides an attenuation of high-frequency components, which are especially due to the presence of inverters in the circuit and are the main cause of unwanted tripping of residual current devices. This ensures a high degree of safety in the systems and a high level of service continuity.

RD3 Functions and features Test no Trip function Residual current tripping adjustable Green LED: power supply voltage Signalling LED bar IΔ% Tripping time adjustable Red LED: alarm status Test Version Resistance to unwanted tripping Type A Power supply voltage Reference standard Reset Dip-switch to set the autoreset and the pre-alarm function RD3P Pre-alarm threshold adjustment LED (60% IΔ) Green LED: power supply voltage Red LED: alarm status Green LED: power supply voltage Red LED: alarm status Residual current tripping adjustable Tripping time adjustable Residual current tripping adjustable Tripping time adjustable Test button Reset button Dip-switch to set the pre-alarm function RD3M Version Resistance to unwanted tripping Type A Power supply voltage Reference standard Test button Reset button RD3 Version Resistance to unwanted tripping Type A Power supply voltage Reference standard 6

Functions Pre-alarm - RD3P, RD3M When the dip-switch is set to, the prealarm function is activated: the output contact marked by the terminals will switch in case of a fault detected by the device exceeding 60% IΔ. Autoreset - RD3P When the dip-switch is set to, the automatic Reset function is activated: the output device contact will return to stand-by when the fault condition has been resolved. Pre Alarm Pre Alarm Autoreset OFF Autoreset OFF OUTPUT device Prealarm / TRIP OUTPUT device Prealarm / TRIP FAIL SAFE OUTPUT device TRIP Fail-safe - RD3, RD3M, RD3P Integrated in the device (positive safety). In case of power supply voltage failure of RD3 device, the output contacts numbered will switch as shown below. Test No Trip TEST RESET 3 sec. t [s] FAIL SAFE OUTPUT device TRIP RESET Remote Reset Contacts when the device is OFF Technical data Power supply voltage RD3 RD3-4 230-400Vac +% / -15% -4Vac/dc +% / -15% RD3M RD3M-4 230-400Vac +% / -15% -4Vac/dc +% / -15% RD3P RD3P-4 230-400Vac +% / -15% -4Vac/dc +% / -15% Operating frequency 45-66Hz 45-66Hz 45-66Hz Frequency filtering - 45...150 Hz f T =400Hz 45...150 Hz f T =400Hz Type A (up to IΔn=5A) A (up to IΔn=5A) A (up to IΔn=5A) Operating temperature -25 C...+0 C -25 C...+0 C -25 C...+0 C Max power consumption < 3,6W (RD3) < 600mW (RD3-4) < 3,6W (RD3M) < 600mW (RD3M-4) < 3,6W (RD3P) < 600mW (RD3P-4) Tripping threshold adjustment IΔn 0,03-0,1-0,3-0,5-1-2-3-5--30 0,03-0,1-0,3-0,5-1-2-3-5--30 0,03-0,1-0,3-0,5-1-2-3-5--30 Tripping threshold adjustment Δt 0-0,06-0,2-0,3-0,5-1-2-3-5-0-0,06-0,2-0,3-0,5-1-2-3-5-0-0,06-0,2-0,3-0,5-1-2-3-5- Pre-alarm threshold adjustment - 60% IΔn 60% IΔn Toroid-device resistance 3 Ω 3 Ω 3 Ω Max length of remote button-reset connection 15 m 15 m 15 m Output contacts rating A 250Vac A 250Vac A 250Vac Max terminal cable section 2,5 mm 2 2,5 mm 2 2,5 mm 2 Modules 3 3 3 Dimensions (LxHxD) 52,x5x64, mm 52,x5x64, mm 52,x5x64, mm Protection degree IP 20 IP 20 IP 20 Reference standard IEC 604-2 annex.m (up to 630A) IEC 604-2 annex.m (up to 630A) IEC 604-2 annex.m (up to 630A) Toroid selection table TRM TR1 TR2 TR3 TR4 TR5 TR160 TR160/A TR4/A TR5/A Toroid diameter mm 2 35 60 0 0 2 160 160 0 2 Max cable sect. (4x) mm 2 25 35 50 5 240 40 400 400 240 40 Maximum monitored current (1x) A 65 5 5 160 400 630 250 250 400 630

RCQ020 Functions and features Protection threshold from 30mA to 30A Tripping time adjustable from instantaneous to 5 seconds Device status LED Dip-switch to set the signalling status Test button Reset button Removable terminal boards for wiring RCQ020 switchboard residual current device can be combined with the circuit-breakers of Tmax and Emax X1 family up to 50A. With power supply derived from auxiliary network and with the wide range of settings available (current threshold from 30mA to 30A, and tripping time adjustable from instantaneous to 5s), RCQ020 can be used in systems with particularly restrictive installation requirements. RCQ020 residual current device is of the type with indirect action and acts on the circuitbreaker release mechanism by means of the shunt opening release or undervoltage release of the circuit-breaker itself. RCQ020 must be combined with one of its dedicated toroids. The range of toroids includes closed-type toroids up to a maximum diameter of 15mm.

RCQ020 main functions: Protection threshold from 30mA to 30A Tripping time adjustable from instantaneous to 5 seconds Connection to the circuit-breaker through shunt opening release or undervoltage release Combination with closed toroids (maximum diameter 15mm) Type A residual current device Device status LED Pre-alarm/alarm/trip electrical signalling Positive safety function available The opening command to circuit-breaker can be temporarily inhibited (Trip Delay) The circuit-breaker can be opened remotely Use of closed toroids Range Toroid Max I n of use ø 60 250A 0,03...30A ø 0 400A 0,03...30A ø 15 00A 0,1...30A Technical data RCQ020 Power supply voltage Operating frequency Power consumption in service Tripping threshold adjustment IΔn Tripping time adjustment Pre-alarm threshold adjustment Powered device visual signalling Malfunctioning visual signalling Residual current protection tripping visual signalling Pre-alarm/alarm electrical signalling Tripping electrical signalling Remote opening command Remote reset command Dimensions (LxHxD) Protection degree - front Protection degree - back Reference standard 5...415Vac 45 66Hz 2VA / 2W 0,03-0,05-0,1-0,3-0,5-1-3-5--30A Instantaneous 0,1-0,2-0,3-0,5-0,-1-2-3-5 s 25% x lδn 6x6xmm IP41 IP30 IEC 604-2 annex.m

RD3 Tripping signalling, fault situations and order details Signalling Stand-by signal Power supply No TR connection signal Fault signal Power supply TR... TR... OK RD... Power supply TR... RD... RD... OK RD... RD... RD... l % l % 20% 40% 60% 0% l % 20% 40% 60% 0% 20% 40% 60% 0% RD3P Pre Alarm Pre Alarm Pre Alarm RD3M RD3 Fault status When the value of the residual current detected by the toroid exceeds the IΔn threshold, RD3 device opens the circuit-breaker to which it is connected through a release coil. The device can be restored by pressing the reset button on the front panel or, remotely, by connecting the specific terminals as shown below. Connection with shunt trip: Connection with undervoltage release: Remote Reset LOAD 6 1 2 3 4 5 4 3 2 1 5 6 TR... TR... Shunt trip 230V Undervoltage release 230V MCB MCB L1 L2 L3 N PE T2-T1 S2-S1 4 4 3 2 1 3 T2-T1 S2-S1 2 LOAD POWER SUPPLY POWER SUPPLY 1 Remote Reset PE L1 L2 L3 N

Order details RD3 Residual current devices Type code Operating voltage Modules ABB code EAN code RD3-4...4Vac/dc 3 2CSJ2001R0001 4236 RD3 230...400Vac 3 2CSJ2001R0002 3433 RD3M-4...4Vac/dc 3 2CSJ202001R0001 3335 RD3M 230...400Vac 3 2CSJ202001R0002 4031 RD3P-4...4Vac/dc 3 2CSJ203001R0001 3434 RD3P 230...400Vac 3 2CSJ203001R0002 3336 Toroid Type code Version Ø [mm] Weight [kg] ABB code EAN code TRM closed 3 0,10 2CSM02000R 0200 TR1 closed 35 0,2 2CSG0350R 020301 TR2 closed 60 0,24 2CSG0600R 020400 TR3 closed 0 0,454 2CSG000R 02050 TR4 closed 0 0,530 2CSG00R 02060 TR160 closed 160 0,600 2CSG1600R 4350 TR5 closed 2 1,350 2CSG20R 02404 TR4/A openable 0 1,600 2CSG00R 4340 TR160/A openable 160 1,534 2CSG160200R 43606 TR5/A openable 2 1,56 2CSG2200R 0650

RCQ020 Wiring diagrams and order details Connection with the shunt opening release RESET MANUAL AUTO N.U. N.U. PREALARM ALARM RL2 Connection with the undervoltage release RESET MANUAL AUTO N.U. N.U. PREALARM ALARM RL2 Order details RCQ020 Residual current devices Type Operating voltage Order code RCQ020/A 5V-230Vca 065 RCQ020/A 415Vca 0650 Toroids Type Version Ø [mm] Order code ø 60 mm closed 60 0334 ø 0 mm closed 0 0335 ø 15 mm closed 15 050543

A RD3 and RCQ020 Overall dimensions RD3 5 45 52, 6, 13, 5, Toroids for RD3 TRM TR1, TR2, TR3, TR4, TR4A, TR160, TR160A, TR5, TR5A E Type A B C D E TR1 35 0 0 50 30 TR2 60 0 0 50 30 5 43,5 5 RCQ020 6 0 45 A TR3 0 150 160 50 30 C TR4 0 150 160 50 30 35 TR4A 0 145 150 45 25 52,5 D Ø5 B TR160 160 220 236 64 34 TR160A 160 220 236 64 34 TR5 2 3 20 260 36 TR5A 2 3 20 260 36 6 0 Toroids for RCQ020 Toroid Ø 60 mm Toroid Ø 0 mm Toroid Ø 15 mm Diameter A B C D 60 60 4 25 A A 0 0 160 165 40 C C C 15 15 236 236 3 B D B D B D Dimensions in mm 13

Due to possible developments of standards as well as of materials, the characteristics and dimensions specified in the present document may only be considered binding after confirmation by ABB SACE. 2CSC444001B0201 - /200 Printed in Italy 3.000 - CAL ABB SACE A division of ABB S.p.A. L.V. Breakers Via Baioni, 35 243 Bergamo - Italy Tel.: +3 035.35.1 - Telefax: +3 035.35.306-433 Line Protection Devices Viale dell Industria, 1 200 Vittuone (MI) - Italy Tel.: +3 02.034.1 - Telefax: +3 02.034.60 http://www.abb.com