RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Similar documents
RetroAire VPRC/VPRH. Single Packaged Vertical Unit R-410A Refrigerant

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MACH N-407 Heat Pump Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

EMI ENGINEERING SUBMITTAL

MAC N-407 Air-Cooled Chiller

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Advance Release September 2009

Commercial High-Efficiency Condensing Units

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

AIR COOLED PACKAGED CHILLER

Specifications and Performance

EMI ENGINEERING SUBMITTAL

SKYPAK II, 3 Ton Series, gives you a

AVAILABLE WITH ENERGY SAVING ECM MOTOR

MERIT Series R-410A - Upflow / Horizontal

SKYPAK II, 3 Ton Series, gives you a

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

PAJ3. Product Specifications

Specifications and Performance

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

SECTION WATER-SOURCE UNITARY HEAT PUMPS

MERIT Series R-410A - Upflow / Horizontal

PACKAGE AIR CONDITIONER

50TM COMBINATION HEATING/COOLING UNITS

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

VPRC / VPRH. Specifications and Performance. The Right Fit for Comfort. Vertical Packaged Air Conditioner/Heat Pump

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

SECTION FAN COIL UNITS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

50TM TFF COMBINATION HEATING/COOLING UNITS

MERIT SERIES Up Flow / Horizontal

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Call us today! (800)

FCC Fan-Coil Units High-Performance, Vertical

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MAC-120HE-03 Air-Cooled Chiller

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

SECTION CONVECTION HEATING AND COOLING UNITS

SKYPAK II Heating & Cooling Self Contained Packages

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

GUIDE SPECIFICATIONS AQUARIUS ii

C. Samples for Initial Selection: For units with factory-applied color finishes.

13 GEP A L P - 1 A

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Call us today! (800)

Incremental Comfort Conditioners

SECTION AIR HANDLING UNIT

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

PAR5. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Concealed Ducted Split Series R-407C MBH

Call us today! (800)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Commercial High-Efficiency Condensing Units

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

RGE 13 A T - 1 A

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Specifications and Performance S2H

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

CWA4 Chilled & Hot Water Fan Coil

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

R4H4. Product Specifications

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

R4H4. Product Specifications

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Modular Supply Make-Up Air Unit

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

WCH5**4. Product Specifications

R 410A Ducted Horizontal Air Conditioner

Transcription:

Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package vertical, through the wall, limited range heat pump, air conditioning unit. Unit shall be shipped completely assembled and charged with refrigerant and oil, compressor, indoor and outdoor coils, expansion device, fans, fan motors, and controls. Additional installation components, wall sleeve and outdoor air louver shall be included. Unit shall be produced in the United States of America. B. Unit shall meet or exceed ASHRAE 90.1-Latest Edition minimum efficiency requirements for Single Packaged Vertical Units of 9.0 EER and 3.0 COP. 1.02 QUALITY ASSURANCE A. Unit shall be Performance Certified by Air Conditioning Heating and Refrigeration Institute (AHRI). Unit rating shall be in accordance with ARI-390, latest revision, Performance Rating of Single Package Vertical Heat Pumps. B. Unit construction shall comply with ANSI/ASHRAE 15, latest revision. C. Unit construction shall comply with NFPA 70, (National Electrical Code, USA Only) D. Unit construction shall comply with UL484/CSA C22.2 No. 117-1970 (VPRH09-24), or UL1995/CSA C22.2 No. 236 (VPRH30-36). Unit shall bear the ETL and ETLc label. E. Unit shall be operationally tested at the factory for proper operation. F. Unit to be produced in an ISO 9000 Certified Factory. 1.03 DELIVERY, STORAGE, AND HANDLING A. Units shall be stored and handled per manufacturer s recommendations. 1.04 WARRANTY A. Unit shall have a one-year limited parts warranty and a five-year limited compressor warranty. VPRH Page 1 of 6 Dated: 08/24/2009

Part 2 Product 2.01 EQUIPMENT A. Unit Cabinet 1. Unit cabinet shall be constructed of G-90U galvanized steel with a minimum thickness of 20 ga. 2. Unit base pan shall be constructed of G-60U galvanealed steel with a minimum thickness of 16 ga. The base pan shall be powder coat painted to prevent oxidation. 3. Base pan shall be provided with overflow notches to carry excess condensate, or in the event the condensate drain line becomes restricted, the overflow notches shall carry excess condensate into the wall sleeve to exit the building rather than spilling into the space. 4. Unit shall be equipped with a temperature actuated drain valve to remove condensate from the base pan in condensate reevaporation systems. (VPRH09, 12, 19 and 24 only) B. Refrigerant System 1. A complete system refrigerant charge of R-410A shall be installed with the unit. 2. Compressor a. Units shall utilize a hermetically-sealed Rotary (VPRH09-12), Reciprocating (VPRH18, 24-36), Scroll (VPRH19) Compressor. b. Compressor shall have internal and external isolation. c. Compressor motor shall be a Permanently Split Capacitor (PSC) motor with overload protection. 3. Coils a. Heat Exchanger Coils shall be enhanced aluminum fins mechanically bonded to internally enhanced copper tubes. b. Heat Exchanger Coils shall be pressure tested at 500 psig (3447 kpa). c. Coil tubesheets shall be constructed of galvanized steel. 4. Refrigerant expansion shall be capillary tube controlled (VPRH09-12), piston controlled (VPRH18-24), thermostatic expansion valve (TXV) (VPRH30-36) for the cooling side. Heating Refrigerant expansion shall be capillary tube expansion VPRH09-24), thermostatic expansion valve (TXV) (VPRH30-36). 5. Factory braze connections shall be leak tested at 500 psig (3447 kpa). 6. Units shall be equipped with a manual reset High Pressure Switch to disable the unit in the event of a high pressure situation. VPRH Page 2 of 6 Dated: 08/24/2009

C. Drain Pans: 1. Drain Pans shall be constructed of G-60U galvanealed steel with a minimum thickness of 20 ga. and insulated with a closed cell sheet insulation to prevent the formation of condensation. The drain pan shall be powder coat painted to prevent oxidation. 2. Drain Pans will be connected to a factory supplied drain hose leading to the base pan for positive condensate re-evaporation (VPRH09-12,19-24) or an internal drain (VPRH18,30-36). D. Indoor Fan System: 1. Indoor Fan Motor shall be a Permanently Split Capacitor (PSC) type motor with permanently lubricated bearings, Class B insulation, and inherent overload protection. 2. Indoor Fan Motor shall have a minimum of 2 speeds to meet required external static pressure. 3. Indoor Fan Motor shaft shall have inherent corrosion resistance. 4. Indoor Fan Blower shall be a direct drive, forward curved, centrifugal blower and shall draw through the heat exchanger coils. 5. Indoor Fan Blower shall be statically and dynamically balanced. E. Insulation: 1. Conditioned air stream and cabinet shall be factory insulated. Insulation and adhesive shall comply with NFPA-90A requirements for flame spread and smoke generation. 2. Expanded liquid refrigerant and suction piping shall be factory insulated with closed cell insulation. Insulation and adhesive shall comply with NFPA-90A requirements for flame spread and smoke generation. F. Outdoor Air System 1. Outdoor Fan Motor shall be a Permanently Split Capacitor (PSC) type motor with permanently lubricated bearings, Class B insulation, and inherent overload protection. 2. Outdoor Fan Motor shaft shall have inherent corrosion resistance. 3. Outdoor Fan Blade shall be a direct drive, slinger-type propeller fan and shall blow through the heat exchanger coils (VPRH09-12, 19-24). Outdoor Fan Blade shall be a direct drive, propeller fan and shall draw through the heat exchanger coils (VPRH18, 30-36). 4. Indoor Fan Blower shall be statically and dynamically balanced. G. Controls: 1. Controls shall be 24-volt and shall be operable with a 24 volt wall mounted thermostat. 2. Control shall include a minimum on-time for heating and cooling to eliminate system short cycling. VPRH Page 3 of 6 Dated: 08/24/2009

3. Control shall include an Anti-Short Cycle Compressor Protection to eliminate system short cycling. 4. Evaporator Freeze Protection Prevents evaporator freeze up. 5. When power is restored the equipment will resume operation after a three-minute compressor time delay. 6. Fault conditions shall be displayed by an LED code located on the control board. 7. Control Box shall be capable of being mounted in the front of the machine and have the ability to be mounted on the left or right side of the machine (VPRH09-24). H. Electrical Connections 1. Factory supplied line voltage connections shall be either a ground fault interrupter circuit line cord or pigtail leads. 2. Factory supplied field control connections shall be to a terminal block. 3. All power connections shall be capable receiving a strain relief. I. Return Air System: 1. Unit shall be supplied with factory-installed disposable return air filters (VPRH09-24) or washable return air filters (VPRH30-36). 2. Unit shall be equipped with a means to introduce fresh air into the indoor air stream. J. Wall Sleeve/Louver Assembly. 1. Provide a custom wall sleeve for the specified wall depth noted on the Equipment Schedule. a. Wall Sleeve sides, top and diverter panel shall be a minimum of 20 ga galvanized steel. b. Wall Sleeve base shall be a minimum of 16 ga. galvanized steel and shall be sloped to allow for rain water to drain away from the unit. Base shall incorporate a drip lip to channel water away from the side of the building. 2. Provide an anodized aluminum louver for condenser air. K. Special Features: 1. Voltage: a. Unit voltage shall match voltage specified on the Equipment Schedule and shall be 208/230-1-60. 2. Electric Heater: a. Unit shall include Open Coil Element Electric Heater as noted on the Equipment Schedule, as a heat source. Electric Heater shall be factory installed and tested. Electric heater must have a limit switch (VPRH09-36) and fuse link (VPRH09-24) approved for the application. VPRH Page 4 of 6 Dated: 08/24/2009

3. Hydronic Heat (VPRH09-24) a. A hot water heating coil shall be supplied as a field installed module that allows for removal of the chassis without disconnecting water piping. b. Heat Exchanger Coil shall be enhanced aluminum fins mechanically bonded to copper tubes. c. Heat Exchanger Coil shall be pressure tested at 320 psig (2206 kpa). d. Coil tubesheets shall be constructed of galvanized steel. e. Hydronic Module shall be supplied with a 10 Round Duct Collar for ease of installation. f. Factory control wiring to the separate module shall be made by a Molex-Type connector. g. A factory-supplied, field installed 24 vac, 3-way valve shall be supplied. h. Freeze Protection for the hydronic coil shall be factory supplied. i. Field water connections shall be located on the front, left or right side of the unit as noted on the equipment schedule. j. Field water connections shall be [sweat-type connections. Ball Valves with Pressure/Temperature ports shall be supplied. Automatic Balancing Valve connections shall be supplied, and shall include Pressure/Temperature Ports]. 4. Optional Drain Location (VPRH18) a. A field installed drain stub shall be provided and allow for field configuration of the drain location, either in the front, left or right side of the unit. 5. Control Box Location (VPRH09-24) a. The standard unit is configured with the control box in the front. The control box location can be installed on the left or the right side of the equipment. 6. Disconnect Switch (VPRH09-24) a. A power disconnect switch shall be provided for units with electric heat no greater than 5 kw. 7. Custom Painted Outdoor Air Louver L. Accessories: 1. Return Air Access Panel a. A Return Air Access Panel shall be supplied with a standard size, fiberglass, disposable return air filter. The access panel shall be constructed of 18 ga. sheet metal and powder coat painted. 2. Digital Thermostat a. A two stage, Mercury-free, digital thermostat shall be supplied for heating/cooling control. The thermostat shall have a large LCD Display, which easily converts from VPRH Page 5 of 6 Dated: 08/24/2009

Fahrenheit to Celsius Operation, with independent heating and cooling set points. Thermostat shall allow for an automatic heating system shutdown if indoor temperature exceeds 90 F (32 C). Thermostat allows for emergency heat, if mechanical heating is off-line. Thermostat shall have a Low Battery Indicator. b. A single stage, Mercury-free, digital thermostat shall be supplied for heating/cooling control. The thermostat shall have a large LCD Display, which easily converts from Fahrenheit to Celsius Operation, with independent heating and cooling set points. Thermostat shall allow for an automatic heating system shutdown if indoor temperature exceeds 90 F (32 C). Thermostat shall have a Low Battery Indicator. 3. Condensate Drain Stub (VPRH09-12, 19-24) a. A field-installed Condensate Drain Stub shall be supplied to allow for condensate to be removed from the unit base to a central drain system. The drain shall be field configurable for front, left or right side drain. 4. 10 Round Duct Collar (VPRH09-18) a. Provide a 10 Round Duct Collar for connection of the supply air ductwork. VPRH Page 6 of 6 Dated: 08/24/2009