Planning Elevator Relay Groups Programming Millenium for Windows Software

Similar documents
RMS/RPX Reader. User Manual

Installation & User Manual V1.1

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Carbon Monoxide Transmitter

HARDwired Installation/ Owner s Manual

Tri-Stack Smart System

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

21-light Remote Annunciator. Owner s Manual

Dryer Controller M720

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Independent Zone Control (I.Z.C.)

REPEATER FS5200R INSTRUCTION MANUAL

Added password for IP setup page : Password must be in IP format!

User Manual. Dryer Controller M720

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Installer Guide. WARNING Important Safety Information. 1 Specifications

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

UNC100 Integra Manual

ZM1 User Manual JVA TECHNOLOGIES.

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Alarm Panel Operating Instructions

General Purpose IO Technical Manual

Product Manual SZ1144

Monitoring Operator Guide. Access Control Manager Software Version

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

P2267 NETWORK INTERFACE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Version 1.03 January-2002 USER S MANUAL

2000 Series. Program Entry Guide. Control Panels

Memcom Emergency Telephone

Product Manual SZ1145

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

OVEN INDUSTRIES, INC.

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Product Manual SZ1009

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

RC-2000 Thermostat Installation Instructions

D A R A - 4. Data Aire Relay Auto-Changeover

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

INTRODUCTION / TABLE OF CONTENTS

Oxygen (O2) Single-Point Gas Detection System

FIRERAY 5000 range USER GUIDE

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

L O D G I N G S Y S T E M S

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

Laptop / PC Programming Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

prestige Control Application Supplement - TriMax

KT-100 Door Controller

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

A Beginners Guide to Inner Range Systems

Product Data Sheet. Remote Terminals. Features:

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

WARNING Important Safety Information

20 Light Remote Annunciator

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

General Routing Interface

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

Installation Guide for models:

Beacon 800 Gas Monitor Operator s Manual

: PRT / PRT PRT / PRT-N1

Intelligent Security & Fire Ltd

INSTALLATION INSTRUCTIONS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Product Manual SZ1022/SZ1031/SZ1035/

B-40/B-41 Modulating Temperature Controller

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Installer Guide. WARNING Important Safety Information. 1 Specifications

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

D1255RB/D1256RB/D1257RB

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Pioneer-R16 Gas Monitor Operator s Manual

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

WARNING Important Safety Information

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Ammonia Leak Detector Manual

Series. Access Power Controllers. Installation Guide

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

ION7300 Series Revenue Meter

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Model 17A00 Expansion Enclosure

Operator: Save these instructions for future use!

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Transcription:

Installation Booklet: Elevator Control Unit (ECU) Introduction The Elevator Control Unit (ECU) is an option in the Millenium for Windows systems. Once you add an elevator in the software, each elevator relay represents an access point, and each access point can be controlled just like a door. This packet includes both installation instructions and Millenium for Windows software instructions to get your elevator access control up and running. INSTALLATION INSTRUCTIONS Parts List Components & Specifications Illustration Typical ECU Layout drawing Illustration ECU Wiring and Settings Connections tables Wiring Checklist SOFTWARE INSTRUCTIONS Planning Elevator Relay Groups Programming Millenium for Windows Software Parts List The Elevator Control Unit (ECU) comes complete in a metal enclosure with prewired internal power. Other parts involved in elevator access control appear separately. ECD(s) must be ordered separately. Parts List Elevator Control Unit (ECU) EC2-101190 ECU, 120 VAC -OR- EC2-101191 ECU, 240 VAC (export model) Following are required and/or optional accessories: 149-101179 ECD (Elevator Car Control Device) 000-000000 Reader Device(s) same type per site 003-101391 (optional) Plug-in 9 VDC 500 ma Transformer for ECDs - - - (optional) Override Key Switch, single pole, normally closed Installation assumes you already have a Millenium Power Supply with line conditioner (for communications) and reader devices. The same type of reader devices must be used by any one given Site Controller. 1 047-101192 Issue 4 D8-Pkg-2608 3/08 Printed in USA Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet

Components & Specifications Millenium for Windows software release 1.5 or higher. Elevator Control Unit (ECU) Maximum of four (4) ECUs per Site Controller. Each ECU has sixteen (16) 5-AMP, Form-C relays for a total of 64 possible relays per Site Controller. ECUs are available in either 120 VAC or 240 VAC (export) models, and are normally located in an elevator control room and wired to external control room power. Each ECU comes with its own internal power supply. NOTE: An ECU can control different combinations of elevators and floors. Since Millenium software treats each ECU relay like a door, the number of ECUs you install directly affects the number of DCDs you can have per Site Controller. Each Site Controller handles up to 100 DCDs, but the number decreases depending on how many ECUs are required, as illustrated in the following examples: Site ECUs ECDs DCDs Controller Floors Elevator(s) 1 0 0 0 100 1 1 1-16 1-10 84 1 2 17-32 1-10 68 1 3 33-48 1-10 52 1 4 49-64 1-10 36 2 1-4 1-64 1-10 36-84 * 1 1 4 2 84 Table 1: Relation between the number of ECUs per Site Controller and the maximum number of DCDs per Site Controller. (*) The last example will appear in this packet as a reference. The example only uses eight (8) of the ECU s 16 relays (as you will see in upcoming sections.) Notice the number of relays in use does not change the reduction in DCDs when one ECU is installed. Controlling 16 floors with one ECU reduces maximum DCDs to 84. Controlling 8 floors with one ECU also reduces maximum number of DCDs per Site Controller to 84. Elevator Car Device (ECD) Maximum of ten (10) ECD/Reader combinations per Site Controller. An ECD controls an elevator in the same way a DCD controls a door. Wiring connections are the same. ECDs mount in or on top of the elevator car. Power can come from a 8-to-13.8 VDC Power Supply or through an optional, small plug-in DC supply (from the 120 volts normally available in the elevator car.) The ECD connects to a reader mounted in the car, and wires back to the ECU with a twisted shielded communications pair. Reader Device Connects to ECD and mounts in the elevator control panel for use by the elevator passenger. The passenger uses this reader to validate elevator access the same way a user validates door access. NOTE: Each Site Controller must use the same type of readers for example, all key or all keypad. You must also set the J1-Reader Select jumper cap on the ECD either ON or OFF, based on the type of reader used. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 2

INSTALLATION INSTRUCTIONS: Illustrations Typical ECU Layout The ECU connects to the Millenium for Windows network using twisted pair wiring. Elevator master control connections to ECU relays are generally made by the elevator company. SITE Controller Unit (SCU) PC with Millenium for Windows software Power Supply with Line Conditioner System Communications to Millenium Network 2-pair, 22 AWG twisted and SHIELDED cable (Alpha # 5482C or equivalent) *** Must connect ECU communications GROUND to Power Supply with Line Conditioner GROUND.*** ECU 0 ECU 1 ECU 2 ECU 4 Master Slave Slave Slave J5 J5 (optional) J5 (optional) J5 (optional) Relays 1-16 Relays 17-32 Relays 33-48 Relays 49-64 4 ECUs per Site Controller Use J5 terminal to communicate between ECUs and from ECUs to ECDs. 2-pair, 22 AWG twisted and SHIELDED cable (Alpha # 5482C or equivalent) Local Communications to "Slave ECUs," ECDs & Readers ECU power source: (from elevator control room) (1) 120 VAC (P/N EC2-101190) -or- (2) 240 VAC (P/N EC2-101191) ECU comes with its own internal power supply. ECD 0 ECD 1 ECD 9 10 ECDs (Elevator cars) per Site Controller ECD power source: (1) 8 to 13.8 VDC Power Supply with Line Conditioner, -or- (2) Plug-In Transformer (9-12VDC @ 500 ma) Reader Reader Reader Figure 1: Sample Layout of Millenium Plus Elevator Control System The first of the four possible ECUs (ECU ) is called the master and the remaining ECUs (up to 3) are referred to as slaves. The Master ECU communicates to the Slave(s) by connections between the J5 terminal on each ECU circuit board. The Master ECU naming convention requires that the first ECU be numbered as in the Millenium software, as you ll see later in this packet. Millennium Group, Inc. 3 Millenium for Windows ELEVATOR Installation Booklet

ECU Wiring and Settings The ECU consists of a metal enclosure with a power supply and a circuit board. The unit contains all intelligence needed to provide access control for its elevators. J5 Local Comm Main ECU Terminal metal enclosure System communications must go through Power Supply with Line Conditioner To elevator master control ECD J3 Comm 1 2 3 4 5 Gnd TxRx TxRx+ ECU 1 "Slave" J2 Reader Local communication to ECDs, readers & "slave" ECUs 2-pair, 22 AWG twisted and SHIELDED cable. Use second pair as GROUND. Connections ECU-to-ECU: See next page for more on Main Terminal & Local communications connections. J3 Alarms 1-4 RX /TX+ RX /TX RX/TX + RX/TX J4 pre-wired J2 pre-wired ECU 0 "Master" J5 Local Comm Override Key Switch Select 16 Relays per ECU (5-AMPs each) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 S2 ECU Address Switch...3 2 1... ON All OFF = ECU 0 #1 ON = ECU 1 #2 ON = ECU 2 #1 & 2 ON = ECU 3 Jumper cap ON = disabled 5 VDC Power Supply (pre-wired and mounted on enclosure door) 1 2 3 4 5 6 7 8 9 10 Main ECU Terminal HOT Neutral Key Switch TXRX TXRX + Fuse 120 VAC input -or- 240 VAC input (export) Override Key Switch (optional) 1 Millenium Power Supply w/ Line Conditioner TxRx +TxRx System communication to Millenium network (through Power Supply with Line Conditioner.) 22-pair, 22 AWG twisted & SHIELDED cable. IMPORTANT: Ground must connect to power supply with line conditioner. Always connect cable shield to, and tape unterminated end of cable shield to prevent shorting. PIN ECUs Power Supply w/ Line Cond. Site Controller 10 + TxRx + TxRx + TxRx 3 9 TxRx TxRx TxRx 4 8 /Shield 5 J1 1 +TxRx TxRx +TxRx TxRx +13.8VDC +13.8VDC J1 Comm J5 Power SCU Figure 2: ECU Wiring Diagram Manual Override Switch: Notice the ECU includes a jumper connection for an external, manual override switch (normally closed N.C.) for local fire code requirements. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 4

Connections Main Terminal Block on ECU: ECU-Main Terminal (master and "slaves") NO. Function Main Terminal block in ECU ECU 2 ECU 1 Slave Slave ECU 3 Slave ECU 0 Master ( * ) TX / RX TX / RX TX / RX + TX / RX + ( * ) Must connect to Power Supply with Line Conditioner 1 HOT 120/240 VAC TO: Power supply 2 Neutral 120/240 VAC in elevator 3 Earth control room 4 5 Key Switch TO: Override Key Switch 6 Key Switch 7 System Communications TO: Power Supply with Line Conditioner. 8 / Shield 9 TXRX TxRx 10 TXRX + +TxRx ( must connect to Power Supply with line conditioner.) J5 Terminal on ECU ECU 3 Slave ECU 2 Slave ECU 1 Slave ECU 0 Master RX / TX + RX / TX RX / TX + RX / TX RX / TX + RX / TX RX / TX + RX / TX ECD J3 TXR + TXR TXR + TXR J5 Local Communications from ECU to "slave" ECUs and to ECDs ECU (master) ECU (slave) ECD J5 Local COMM J5 Local COMM J3 Terminal Block NO. Function NO. NO. 1 RX/TX + 1 2 RX/TX 2 3 3 4 RX/TX + 1 5 RX/TX 2 6 5 7 8 SLAVE ECUs only apply when more than one ECU exists per site. NOTE: J1 Reader Select jumper must be OFF for Keyloks/Keyreaders and ON for all other types of reader devices. J3 Alarms Terminal No. Function 1 Alarm 1 2 (Alarm 1 ) 3 Alarm 2 4 (Alarm 2 ) 5 Alarm 3 6 (Alarm 3 ) 7 Alarm 4 8 (Alarm 4 ) J2 & J4 Terminals pre-wired Millennium Group, Inc. 5 Millenium for Windows ELEVATOR Installation Booklet

Wiring Checklist: For details, refer to previous illustrations and connection tables. 1. 2. 3. 4. Mount the ECU metal enclosure in elevator master control room. Set the S2 ECU Address Switch based on which ECU you re connecting. Use only the first two switches, as follows. ECU 0 (first) = Switches 1-8 are all in the OFF position (UP) ECU 1 (2nd) = Switch 1 is in the ON position (DOWN) ECU 2 (3rd) = Switch 2 is in the ON position (DOWN) ECU 3 (4th) = Switches 1 & 2 are in the ON position (DOWN) If you ll be using an Override Key Switch, REMOVE the jumper cap from the Override Key Switch Select jumper. Connect the switch cables to pins 5 & 6 on the main ECU terminal. Connect power (Main ECU terminal pins 1, 2, 3,) but keep power off. 5. Connect SYSTEM communications (Main ECU terminal pins 8, 9, 10) to Millenium Power Supply at Gnd, TxRx, & +TxRx. System communications MUST ground to a power supply with line conditioner. If you have subsequent ECUs, make system communication connections between ECUs at Main Terminal pins 8, 9, & 10. 6. 7. 8. Connect LOCAL communications (ECU J5 terminal) to ECD J3 at pins 1, 2, & 5. Remember to set ECD J1 Reader select jumper OFF for Keylok/Keyreader and ON for all types of reader devices. If you have more than one ECU, make local communication connections to subsequent ECUs at J5 terminal. If applicable, connect alarm devices to terminal J3 Alarms. ECU alarms are the unsupervised type, Normally Closed. Power up to test the connections. LEDs for each of the 16 relays in the ECU should illuminate. (Relays are normally energized.) When in use (from a valid access,) the LEDs turn off for the amount of time programmed through the software. (Relays become de-energized.) The 16 relays on the ECU are 5-AMP, Form-C type. Each relay has three terminals for the following circuit types: N.O. (Normally Open) N.C. (Normally Closed) Common Relays are normally energized to provide fail safe operation. Relays are connected to the elevator controls (usually by the elevator company) to either ENABLE or SELECT a floor, as follows: AN ENABLED FLOOR means the relay de-energizes. The ECU tells the elevator to allow the floor button(s) to function. Through the software, you enable a floor just like you enable a door based on valid user and the user s access group assignment. (optional) TO SELECT A SINGLE FLOOR, the relay de-energizes or opens. The elevator company can connect the ECU relay to send the elevator to a specific floor, based on the user s access code. This mode only allows the passenger access to one floor. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 6

9. Program the ECU into the Millenium software and create floor relay access points as described under Software Instructions next in this booklet. Millennium Group, Inc. 7 Millenium for Windows ELEVATOR Installation Booklet

SOFTWARE INSTRUCTIONS: Planning Elevator Relay Groups When you finish making and testing connections, use Millenium for Windows software to program elevator access control. Assign ECDs in each elevator to relays or to groups of relays on the ECU. As a result of your relay grouping, a single set of 16 relays can control: four (4) separate elevators (ECDs) each going to four (4) controlled floors (first example, below) OR one (1) elevator (ECD) going to 16 controlled floors (last example, below.) ONE Site ECUs ECDs DCDs Controller Floors Elevators Relays 1 0 0 0 0 100 programmable per following examples: Floors ECUs Elevators or 1 16 1 1-16 ECU 0 84 or 4 64 1 1-16, 17-32, 33-48, 49-64 ECU 0 ECU 1 ECU 2 ECU 3 36 Exercise uses this example. 1 4 2 1-4, 5-8 or 2 4 2 1-4 5-8 or 1 4 4 1-4, 5-8, 9-12, 13-16 ECU 0 ECU 0 ECU 1 ECU 0 ECD A ECD B ECD A: ECD B ECD A ECD B ECD C ECD D Table 2: Examples of some ECU relay groupings (through programming in Millenium for Windows software.) For the upcoming exercise, assume one ECU will be controlling two elevators (ECDs) in a building with four floors, as shown in the following figure: 84 68 84 Relay #16 ECU MAXIMUM 10 ECDs (elevator cars) per Site Controller. Relay #1 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Relays 5-8 control CAR B Relays 1-4 control CAR A Elevator Car B (ECD 0) Elevator Car A (ECD 1) Reader buttons 1-4 enabled by Relays 5-8 Reader buttons 1-4 enabled by Relays 1-4 Figure 3: Example of one ECU controlling two Elevators (ECDs) and serving four floors. Relays 1-4 in ECU 0 control four floors for CAR A (first elevator.) Relays 5-8 in ECU 0 control four floors for CAR B (second elevator.) Elevators are represented as ECDs in the software. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 8

Programming Millenium for Windows Software Exercise One ECU to control two elevators going to four floors: 1. Create the ECU (Elevators dialog) In Millenium for Windows software, click the Elevator button to program the first ECU into the software. (a) Select the site under which this ECU is installed. (b) Type a name for the new Elevator Controller (ECU.) NOTE: The first Elevator Control Unit MUST be number 0 because the first ECU under a Site Controller is the master. The above example shows the maximum number of ECUs (4) that can be under one Site Controller. In this exercise, the second elevator will also come under ECU 0, but will use different relays. (c) Click the ECD Reader Setup button to choose the type of reader to be used by all ECDs under this site controller. Millennium Group, Inc. 9 Millenium for Windows ELEVATOR Installation Booklet

NOTE: All ECDs under one site must use the same type of reader. The reader validates a passenger s access to the elevator floor in the same way a reader validates a user s access to a door. (d) Press the save button. Alarms and Events are described in an upcoming section and may be set up later. Use the Notes section to record any information that might be helpful to software operators. 2. Name Elevator Cars (Elevators dialog) The next step is to name elevators (Elevator car Control Devices ECDs) and select the floors that will be served by a given elevator car's reader. (a) In the ELEVATOR dialog, click to select the Elevator Car tab. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 10

(b) The currently selected SITE NAME appears highlighted if you already selected the site on the main Elevator tab. If no site has been selected, highlight a SITE NAME where you want to define and name the elevator floor relays. (c) In the ECD section, type a NAME for the elevator car (ECD) that operates under the given Site Controller. You can have as many as ten (10) elevator cars for one site. The name can be up to 19 characters long. Site Floors: The Site Floors listbox will show all ECU floors programmed under the given Site Controller. Notice the ECU that controls each floor relay will appear in parentheses after the floor name. (d) The Site Floors listbox would appear empty at this point in an initial installation. The above example shows the listbox after you complete step 3 (Access Points dialog/ecu Floor Relays tab.) Selected floors will be served by the given elevator car reader. That is, when a valid passenger uses their key or card in the elevator reader, corresponding button(s) on the elevator control panel will light according to that passenger's access group rights. Passenger then chooses the desired floor. Summary: You can make the same programming setting in two different locations in the software. Select what floor relays can be activated by an elevator car reader in the Site Floors listbox (Elevator Car tab), and Select the reader that will be active for a particular floor (ECU Floor relay) in the following Floor Readers listbox: (ACCESS POINTS dialog ECD Floor Relays tab is covered in more detail under step 3 below.) Millennium Group, Inc. 11 Millenium for Windows ELEVATOR Installation Booklet

The Floor Readers example shows Elevator Car A's reader is active for the Lobby floor. The Floor Readers dialog and the Site Floors listbox both show identical data in two different ways. (e) Type in any notes to provide more description of the given Elevator car Control Device (ECD), if desired. (f) Press the save button. Repeat the process to name additional ECDs and select the floors they serve. 3. Program ECU Floor Relays (ACCESS POINTS dialog) Since the software handles elevator floors like doors (as access points), you can assign the following controls to the elevator for the given floor: Each floor can be set for Auto activate or First user auto activate, just like a Millenium door. (RELAY MODE field in the ECU Floor Relays tab/access POINTS dialog.) Amount of time an elevator control relay is available to the passenger (de-energized) is adjustable through the software from 1-255 seconds, just like a normal door. (ACTIVE TIME field in the ECU Floor Relays tab/access POINTS dialog.) (a) Click the ACCESS POINTS toolbar button, and select the ECU Floor Relays tab. (The following sample is already filled in.) Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 12

(b) Select the ECU for which you want to name and define up to 16 relays (floors.) (c) Press the button or move to the blank ECU Name field. (d) Type a NAME to identify/describe the floor for a given relay. The name you type will appear in the ELEVATOR dialog's Elevator Car tab (Site Floors listbox.) From the Site Floors listbox, you will select those floors an elevator car will serve. NOTE: Elevator floors correspond to the 16 possible relays on an ECU. Floor NUMBERS for the 16 relays range from zero ( ) to 15. The ECU Relay Number must accurately reflect the relay wiring. Relay 1 on the ECU must be wired to activate the button for the floor in the elevator car's passenger control panel. (e) Click the button to select the Elevator car Control Device (ECD) reader(s) that will control access to the given floor. The reader device attached to a selected ECD will receive a user's key or card and grant or deny elevator floor access based on the user's Access Group. You can also select readers in the Site Floors listbox (ELEVATOR dialog's Elevator Car tab, covered under Step 2 (b) above.) (f) Program the floor reader to control access to the given floor: Relay Mode Select the mode that will control how the reader controls access to the elevator floor. RELAY MODE options No action Auto activate First user auto activate Valid user Rejected user Any user Elevator relay does not activate for this floor. Elevator relay activates during a certain period of time based on the ACTIVE TIMEZONE. Elevator relay activates on first valid user during the ACTIVE TIMEZONE, and remains activated until the end of the timezone period. Elevator relay activates for a valid user, for the ACTIVE TIME (seconds), but only during the ACTIVE TIMEZONE. Elevator relay activates for a rejected user, for the ACTIVE TIME, but only during the ACTIVE TIMEZONE. Elevator relay activates for any user, for the ACTIVE TIME, but only during the ACTIVE TIMEZONE. Active Timezone Seconds Active If appropriate, select the TIMEZONE during which the given floor relay will be available to valid users. The Active Timezone is commonly used with the Auto activate and First user auto activate relay modes. Time-related relay modes let you set the number of seconds you want the elevator control relay to remain active (de-energized.) Maximum is 255 seconds with 5 seconds being an average setting. Millennium Group, Inc. 13 Millenium for Windows ELEVATOR Installation Booklet

(g) Type any extra description/information in the free-form NOTES box that might be helpful to operators when this dialog appears. (h) Press the save button. (i) Send the new programming data to the Elevator Control Unit (ECU.) Use the Execute button to display a menu of special operator actions. Highlight the Update action to send all elevator programming data to the ECU for all relays. This update action is identical to the update that appears on the main Elevator dialog under the Execute button. Update Elevator The Update action from the main Elevator dialog will manually send all data you ve just programmed in the Elevator and ECU Floor relays dialogs to the ECU circuit board. This update action does the same thing as the update that appears on the Access Points dialog ECU Floor Relays tab, under the Execute button. If the elevator control option is being installed in an existing Millenium system, you must use the Update option under Execute button in the main Elevator dialog. If the elevator control system is being installed as part of an overall system installation, the elevator data will be updated along with all other Millenium data when you update the site. After installation, this action is only used in special circumstances when the PC does not automatically update an ECU. (Example after an ECU has been off-line for installation or repair.) You can also update the elevators by performing an Update from the Site dialog. 4. Assign users, events, and alarms Assign users to floors in the same way you assign users to doors. ACCESS GROUP dialog in Millenium for Windows software displays elevator floors along with doors. Operator can set up a desired TIMEZONE for each floor, through the TIME dialog. Set up Events and Alarms for ECUs, just as you would for doors. A Millenium operator can set up alarms and events for elevator floors through the two buttons on the main Elevator Controller (ECU) tab. NOTE: The Manual Override Switch actions in Millenium for Windows' history appear as Bypass and Bypass Reset. Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 14

Elevator Alarms setup Up to four alarm devices may be wired to the ECU at terminal J3 Alarms. If you have alarm devices wired to the ECD, setup up those alarms as described below. NOTE: Once you have set up elevator alarms to use one or more of the four possible ECU alarms wired for the given elevator controller, the name you give to each alarm appears in that elevator's Device Events setup dialog. (a) Open the main Elevator dialog, and select the Site and the ECU. (b) Click the Alarms button. (c) ALARM NAME: Type a description which will identify the alarm. Notice the alarm number corresponds to one of the four available alarm inputs on the ECU circuit board. (d) IGNORE TIMEZONE: Select a timezone during which the alarm is to be ignored. IGNORE options Never User-defined Always Alarm is always in effect never ignored. Any timezones you set up under the TIME menu will appear in the drop-down selection listbox. You may create a special timezone through the Timezone dialog during which the elevator will ignore an alarm. Alarm is never in effect always ignored. Millennium Group, Inc. 15 Millenium for Windows ELEVATOR Installation Booklet

(e) SHUNT DELAY (IN SECONDS): Type (or use the arrow buttons to increment to) the amount of time you want to allow before the alarm sounds. Options are 1-255 seconds. (f) PRIORITY: Use the mouse to click and drag the pointer to the priority level you want to set for the given alarm. (g) Press the save button to keep the alarm programming as it appears. Elevator Events setup Scroll through the list of Millenium for Windows event actions. Select those actions that you want to assign to each ECU. Assign events for which you want optional relay devices (RCDs) to respond as well as those events for which you want each site on a DialUp communications system to call the main PC. In addition to the four available alarms, an ECU has a tamper and a manual bypass alarm along with their resets. Any of the four possible alarms you wire and program appear below the tamper and bypass options in the Events listbox. (a) Open the main Elevator dialog, and select the Site and the ECU. (b) Click the Events button. (c) EVENTS: Click the checkbox in front of each event to select those events for the given site and ECU. Notice that the tamper Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 16

and manual override bypass events appear by default. Any other events appear with the name you gave to the corresponding ALARMS you set up for the given site and ECU. The events you select will be sent when you click the OK button. Include both the event and its complementary event in cases of on-and-off type actions. If you have any alarms wired in the given ECU, select both the alarm and its corresponding reset event. For example: Bypass / Bypass Reset. (d) Press the OK button to have the selections be among the events for the given ECU. Remote Floor Unlock Just as Millenium Plus doors have a remote unlock feature, so elevator floors can be unlocked by all pre-defined Millenium Plus operators. Scroll to the name of the floor to be released. The elevator will release for the amount of time the elevator relay is set to be active in the Assign Floors (relays) data box, ACTIVE TIME field. For elevator cars (ECDs) with a Marlok Keylok reader, two people must be involved in the remote unlock process. A user must insert and turn a key in the lock cylinder while the operator performs the Remote Unlock function at the computer. History reflects Operator Unlock, and identifies the elevator floor, site, and operator ordering the action. After the remote lock actually opens, history reflects Remote Unlock, and identifies the floor and site. Override floor Just as Millenium doors have an override strike feature, so elevator floor relays can be overridden by all pre-defined Millenium Plus operators. Scroll to the name of the floor to be overridden. An OVERRIDE MODE field displays. Use <F4/F3> key to scroll between options. Millennium Group, Inc. 17 Millenium for Windows ELEVATOR Installation Booklet

OVERRIDE MODES None Locked Unlocked No floor override is in effect. Elevator floor relay will function as programmed in the software. Normal resting state is energized as a fail safe precaution. Elevator relay for the selected floor changes from de-energized to energized, meaning the floor is temporarily restricted or disabled for the number of hours set in the OVERRIDE TIME field. Elevator relay for the selected floor changes from energized to de-energized, meaning the floor is temporarily released or enabled for the number of hours set in the OVERRIDE TIME field. The elevator relay will change state (from energized to de-energized or from de-energized to energized) for the amount of time, in hours, set in the OVERRIDE TIME field. At the end of the override time, the relay will return to its normal state. Summary: How the elevator control process works 1. User enters elevator car and inserts his/her key or card. 2. If user is valid, the green LED on the ECD reader illuminates. 3. In the ECU, the floor relay(s) designated in the software de-energize. 4. When the ECU relay opens, those buttons that correspond to the de-energized relays will function for the user. The user then presses the button for the desired floor. NOTE: The elevator can be set to go to one specific floor based on the user s access. This single-floor option involves the way the ECU relays are wired to the elevator controls. Refer to Wiring Checklist under Power up. What Releases Elevators? Relays release (de-energize) elevators in the following situations: Valid user inserts a key/card into reader. Timezone is active based on a valid user s access group assignment. ECU loses AC power. Optional external override switch is manually used. Remote Floor Unlock action is used. Override floor action is used (Unlocked mode.) Millennium Group, Inc. Millenium for Windows ELEVATOR Installation Booklet 18

Electrical Specifications ECU power: (external, from elevator control room) 120 VAC, ½ AMP, 50-60 Hz (domestic) 240 VAC, ¼ AMP, 50-60 Hz (export) ECU has 16 relays, 120 VAC and 30 VDC, 5 AMPs each. ECD power: Power Supply, 8 to 13.8 VDC with line conditioner, or Plug-in transformer, 9-12 VDC at 500mA Environmental Specifications Temperature range for Millenium Plus Elevator control electronics: 14 to 104 F (-10 to +40 C) Millenium Plus Elevator control electronics are designed to tolerate non-condensing humidity up to 90%. 9 Tech Circle Natick, MA 01760 www.millennium-groupinc.com Technical Support: 1-866-645-4771 Customer Service: 1-866-455-5222 Millennium Group, Inc. 19 Millenium for Windows ELEVATOR Installation Booklet