Schübeler DS-DIA Ducted Fan Series Manual

Similar documents
ELECTRIC DUCTED FAN INSTRUCTION MANUAL

70 mm Electric Ducted Fan Power System

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

TOS-002-US Gear Hobbing Machine TH 350 CNC

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

A. Codes and Standards that are Standard at the University:

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SECTION (15833) - HVAC POWER VENTILATORS

Marley Ultra Quiet Fan

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

High-efficiency Turbo Chiller (NART Series)

BUBBLE-Maker. Necessary tools and materials:

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Old style propeller New style propeller

Heating Coils manifold

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

SECTION AIR HANDLING UNIT

Processing Instructions

Spare parts list. Hydraulic compactor RC

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

Lenntech. Tel Fax bar. Multistage Pumps.

Pentz EF5 Installation Guide

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

TECHNICAL BULLETIN VG4 Series Modular AutoDome

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Powered by a 12 volt DC Wall Wart

LDDC Series Double-Deck Drum Pre-cleaner. Instruction Manual LAMBTON MACHINERY(ZHENGZHOU)CO. LTD

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

FRL 10 Centrifugal blowers

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

AZN ATEX INSTALLATION AND MAINTENANCE

SERVICE LETTER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation Instructions Part No , Part No Part No

THE WIDTH AND HEIGHT OF THE LIGHT HOLE IN THE WINDOW WING IS MEASURED IN THE FOLLOWING WAY:

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

CG-16N/20N. Low Speed Granulator. Designed for grinding sprues, runners and rejected ed parts beside the press. Standard Features. cometpe.

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

APW PSI PRESSURE WASHER

Development of Large Size Hybrid Fan

Part Nos.: Laminators

INSTALLATION INSTRUCTIONS

Requires: 4-channel radio w/ 4 micro servos, Outrunner Motor KM A brushless ESC, 3 cells 11.1V 2100 mah Li - Po battery & charger.

Adjust-a-Sink K100 SERIES **INSTALLATION INSTRUCTIONS**

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Top-Secure Data Destruction Systems Over 50 Years of Experience and Innovation

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

IEC- Direct-driven radial fans with IEC-Standardmotor

Assembly and Running Instruction for Steam engine

FAN IMPELLERS & FAN CASINGS

Installation Instructions for Q-Siren Q2B-012PSD, Q2B-012NNSD, and Q-MT

HEATING AND VENTILATION

INLET DAMPER WALL FAN UNIT

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

AC Backward Curved Motorized Impellers

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Requires : 4-channel radio w/ 4 micro servos, Outrunner Motor w/ Propeller Adaptor 20A Brushless ESC, 3 cells 11.1V 2100mAh Li - Po battery & charger.

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

568X, 587X, 588X Series

Guidelines for Earthquake Bracing of Residential Water Heaters

Static Electricity: Bending and Floating

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

BQ-260/260L. Important Information BOOK BINDER

019 ASSEMBLING THE HOTEND

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

A/C COMPRESSOR OIL CHECKING

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

PVC Ductwork Model. Installation and Maintenance for

PUMPS FOR LIVESTOCK WATERING SYSTEMS. This Factsheet outlines the design and operation of pumps that are suited for livestock watering systems.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

JM Aerofoil Fans Bulletin JMA60-05

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Transcription:

Schübeler DS-DIA Ducted Fan Series Manual Manual for the following fan units: DS-26-DIA HDT DS-30-DIA HDT DS-44-DIA HDT DS-51-DIA HDT DS-75-DIA HDT DS-94-DIA HDT

Safety instructions (Read before first use!) The DS-DIA ducted fan system is solely to be used in non man-carrying RC models. Any other use is prohibited. Please read and follow the assembly instructions carefully. Run your fan unit only outdoors and installed in your model or on a test bed with chip protection. When running the fan unit do not stay in front of or beside it. Never hold your hand in front of the intake. Stay away from the jet stream of the fan unit. Before starting the fan unit always remove all loose parts like clothes, tools etc. Always mount the rotor unit properly on the shaft as described on page 4. Never use the fan unit when realizing unusual vibrations. Stop it immediately and find the cause before running it again. Never exceed the maximum allowed rotational speed for you fan unit (see Technical Data ). Cool down all drive components - particularly battery and motor - before starting for another flight. Never exceed the maximum allowed voltage for your fan drive system. Before first use make sure that all screws are tightened properly, especially the grub screws fixing the rotor. The advantages of you new Schübeler fan unit: The DS-DIA fan unit is a high-end product for efficient electric jet flying. Your fan is handmade in Germany by using high-quality materials; due to weight and strength reasons no inection-molded parts are used. Each fan has to pass a strict final check. A special feature of all genuine Schübeler fan systems are the fine-balanced rotor units. The DS-DIA fans have been optimized to guarantee highest efficiency during horizontal and high-speed flight. Static thrust is also very high to enable powerful take-offs. The special diagonal shape of the hub allows you to run your fan at highest rpm s free from resonance or vibrations. Have fun using your Schübeler DS-DIA fan unit!

Drawing 1: The parts of your Schübeler fan unit Grub screws Streamlined fairing Tip clearance Stator Rotor unit, fixed with glue (Do never disassemble this unit!) Motor former Shroud The identification code of the DS-DIA fans: Designer s initials Rotor hub with diagonal shape DS-30-DIA HDT Swept fan area in cm² High Dynamic Thrust aerodynamics General assembly instructions: Use controllers with soft start and deactivate the brake. The carbon fibre fans of the DS-xx-DIA HDT series come fully assembled. You just have to install the motor and mount the rotor unit. For all fan units we additionally offer the Secure Fan Fix system for fixing the fan into the fuselage.

Assembly of the DS-xx-DIA HDT fan unit: 1.1. Solder your controller to the motor. Always place the controller near the battery to keep the cables short. Provide cooling air for the controller through openings in fuselage or intake. Make an oval cutout between streamlined fairing and stator to lead through the three motor phases (drawing 3). 1.2. Mill a small flat on one side of the motor shaft with a Dremel tool so that the screw connection of the rotor can handle higher torque (drawing 2). Shift the motor into the stator to find the right position for the flattening by means of an Allen key. The fit between adaptor and motor shaft is deliberately very tight.should you need force to slide the rotor onto the shaft please smoothly sand the shaft with sandpaper grid 600. Please contact us in case of doubt. (Close all openings of your motor with adhesive tape to protect it from chips!) 1.3. Fix the carbon sticks with double-sided adhesive tape to the rear end of you motor (drawing 2). Wrap motor and sticks with several layers of clear adhesive tape until the motor fits tight into the stator. 1.4. Screw motor to motor former. To adjust the tip clearance the motor can be slightly moved. 1.5. Fix the rotor on the motor shaft and secure the grub screws with a small amount of Loctite 222 (can be obtained from us). Always shift the rotor unit up to the maximum position of the shaft to avoid vibrations. 1.6 Depending on the preferred way of fixing the fan into the fuselage use the optionally availavle Secure Fan Fix system. Drawing 2: Your prepared motor, ready to install Adhesive tape wrap Flat on the motor shaft Carbon sticks

Assembling the optional Secure Fan Fix system: 2.1. The Secure Fan Fix system consists of high-quality carbon CNC-milled parts which are precisely made, lightweight and very rigid. It enables fixing of the flanges in an exact 180 angle and keeps also big and heavy fan units in the fuselage. 2.2. Glue the three carbon parts together with cyanoacrylate. Pay attention that: 1. Both flanges are parallel in front view. 2. The flanges form a right angle with the arch. 3 The flanges are parallel in top view. 4. The bottom side of the flanges are coplanar to each other. (Pictures 1-3) 2.3. After curing put the pre-assembled Secure Fan Fix system on the fan unit. The rear edge of both flanges is flush with the rear edge of the shroud. When using a fan unit with an even number of stator blades the flanges should be placed on two stators. Also pay attention to the required position ot the motor label and the cable lead-through. Scribe the outlines of the Secure Fan Fix system. Sand this area of the shroud and fit the Secure Fan Fix system at right angles. Glue with cyanoacrylate and make glue lines with black-colored Epoxy glue (picture 4). Picture 1 Picture 2 Picture 3 Picture 4

Drawing 3: Dimensions DS-xx-DIA HDT fan unit:

Part list DS-xx-DIA HDT: -Fine-balanced rotor unit, carbon-aluminium -Carbon-sandwich shroud -Carbon stator, glued to shroud and with installed carbon CNC-cut motor former -1 carbon streamlined fairing -Miscellaneous cylinder head bolts -Carbon sticks for motor centering -1 Allen key SW 1,5 or SW 2,0 DIN 911-1 Manual Technial Data: