Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Similar documents
Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9000 Advanced Thermocouple Controller

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

108A OTP1800. Grid Support. General Description

TEMPERATURE CONTROLLER (STANDARD MODEL)

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

TEMPERATURE CONTROLLER R/S (ADVANCED MODEL)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

SmarTemp Control fx 2.0

TC515 and TC600 Installation Manual. a Winters company

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Dryer Controller M720

User Manual. Dryer Controller M720

Digital Marine Exhaust Temperature Alarm

VIDEO CONTROLS LIMITED

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual

Model: Edge-HC. 1 edge-hc

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Dryer Master DM510 Commissioning Guide

HBC-4301 Hot Bonding Controller. Operators Manual

TV2 Room Pressure Monitor Quick Start Guide

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

QTC15 Temperature Controller Operation Manual

DC200 Digital Dispenser Operating Manual

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

GTC15 Temperature Controller Operation Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL 86002

THX-DL Data Logger USER & INSTALLATION MANUAL V

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Oven Control System Operation - Ver 2.8

Autoclave Operations Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Laptop / PC Programming Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

CG Series Digital Temperature Controller OPERATIONS MANUAL

EW 40 Wireless Fan Control

Halton SAFE / 7.14 user guide and installation instructions

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

KitchenAid Food Stream Solutions Classic and Integrated Series

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

WHA 3000P Hot Air Station

918TS Manual 1/26/09-1 -

S/601 Controller Installation Manual

UPS BATTERY TEST. Testing the UPS Battery (Verification Test) Locking models: 13/19/22-USGF, 13/19/22- USGR, 43/44-UDGR, 43/44-UDGF

BTC15 Temperature Controller Operation Manual

CAREL IR33+ CONTROLLER

FLOW CONTROLLER TYPE S/601

JOVY SYSTEMS RE User Manual Rev. 1.00

SOLARREM QUICK START OPERATION MANUAL

Model 96VTR ¼ DIN Process Controller

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen

SCAN200E USER S MANUAL

User Operation Manual

Guide, Quick Start, Short, X-100 System

VENTURI Compact 300 NPWT Systems Choice of Therapy Modes Advanced Predictive Low Vacuum Alarm

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

TTT Digital Incubator

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Contents 1. GENERAL DESCRIPTION TECHNICAL DATA INSTALLATION...4

ST9400A User Guide. Features

DIESEL Engine Fire Pump Controllers Features

Operation Manual Digital Heating Hotplate HP-1D

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Remote Display Alarm Indicator for Oxygen monitor

Autofire Express Ramp/Hold Controller Instruction Guide

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

CONTENTS Introduction Information Services Getting Started Phone Directory Messages Optional Features Alerts Other Features

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Model: Available in: Sapphire Black and Glacier White. 1 Series

Med Touch Master Alarm

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Portable type of Carbon Dioxide Detector Model: GT220

DYGIZONE GJD910 Lighting Controller & Enunciator

OVEN INDUSTRIES, INC.

CT224 Setup Tutorial

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Insight Operating Manual

Model: Available in : Sapphire Black and Glacier White. 1 Series

BC-4000 Bilge Monitor/Controller Installation Manual

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Mark 25 Ultrapure Water Conductivity Analyzer

Digital Knight 16x20 Automatic Digital Swinger

Operation Manual. Programmable Logic Controller

Transcription:

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input THE STANDARD IN PRECISION MEASUREMENT 1

Getting Started: 7 6 2 1 Front 5 4 3 1) RUN/STOP Button Pressing RUN/STOP once will start the control process if the temperature controller is stopped, or stop the control process if the temperature controller is the run mode. If the temperature controller is running, Heat and Cool on-screen indicators will illuminate appropriately with the mode selected in the setup menu. The Control Action selection is in the Advance Menu Gateway setup. 2) TUNE Button Pressing TUNE once will start the AUTO TUNE cycle. AUTO TUNING must be enabled in the setup menu for this key to function. 3) ALARM Button In an ALARM situation, the display will indicate either WARNING or ERROR with corresponding warning or error. A WARNING will not stop the control process. An ERROR will stop the control process. MANUAL RESET mode: Pressing ALARM once will silence the audible alarm and clear the on-screen alarm message. If the alarm situation is still present, the Alarm/Action Display will remain illuminated. The alarm and on-screen message will not clear automatically, even if the system is no longer in an alarm situation. AUTO RESET mode: Pressing ALARM once will silence the audible alarm and clear the on-screen alarm message. If the alarm situation is still present, the Alarm/Action Display will remain illuminated. If the system leaves an alarm situation, the system will automatically silence the alarm and clear the on-screen alarm message. 4) SELECT Button Pressing SELECT once will allow you to cycle through user-configurable control Set Points. The Set Point selected will be underlined. Use the UP and DOWN arrow keys to change the value. 2

Getting Started: 7 6 2 1 5 4 3 Front 5) MENU Button The MENU button provides access to all user-configurable setup parameters of the temperature controller. Pressing this key once will scroll through parameter options. Pressing and holding this key will exit to the home screen, saving any changes made up to that point. 6) UP, DOWN, LEFT Arrow Buttons The UP and DOWN arrow buttons will increase or decrease the value of the Set Point selected (underlined). Pressing the UP or DOWN arrow keys will increase or decrease numerical entries by the least significant digit (i.e. 00.0 to 00.1, 1 to 2). Pressing and holding UP or DOWN arrow keys will increase or decrease numerical entries using an acceleration factor. For every ten units, the rate of acceleration will increase by a factor of ten. Pressing and holding UP and DOWN arrow keys will increase or decrease text entries without an acceleration factor. The LEFT arrow button allows you move backwards through the GENERAL SETUP MENU (GSM) and ADVANCED SETUP MENU (ASM). While in the ASM, you can move backwards to the first ASM screen, but cannot back into the GSM. To exit to the main screen from either menu, press and hold the MENU button. 7) HEAT, COOL, AND TUNE Indicators When any of these modes are active, it will have a block indicator on the display showing it is active. Example: When the controller is in the heat mode and is applying power to the heater output, there will be an indicator block on the display next to Heat to show the heater output is active. 3

IEC 60320 C19, 230 VOLT 5-15R,115VAC (Shown in image) BACK 1. IEC power cord connection (see page 32 in the User Manual for additional cords) 2. Fuse 3. Heater/Cooler output (see pages 33 34 in the User Manual for optional cord adapters) 4. Power switch 5. Grid support bracket 6. Thermocouple input: accepts types J, K, N, R, S, T, B, and E with mini-connector 4

Setup and Operation Initial Setup Install controller in a safe operating area. Plug the heater or cooler (sold separately) into the output connector, located on the back of the controller. Connect the thermocouple sensor input connector, located on the back of the controller. Place the ferrite clip over the lead wire of the thermocouple sensor. See page 31 in the User Manual for reference picture of installation of ferrite. Plug supplied AC cord into the IEC power connector, located on the back of the controller. Basic Operation Setup Turn power switch ON, located on the back of control. Follow the instructions on the welcome screen. - Press SELECT key to read a brief description of each key on the front of control. - Press the MENU key to skip the instructions and enter into the main operation screen. Press the SELECT key to make a user-editable field active. A line will appear under the field when the field is active for editing. Use the UP/DOWN arrow keys to adjust the value that is active in a user-editable field. Enter the user-configurable setup by pressing the MENU key from the system status screen. Use the MENU key to advance through each menu setting. TC9000 control mode is set at the factory for PID operation with a type J thermocouple input sensor. If different control mode is desired, reference the User Manual for setup instructions. All changed settings will be retained in memory when returning to the System Status screen. Use the screen flow charts on pages 29 30 of the User Manual to have a visual of the controls menu layout. Auto Tune Operation Setup Set up your process as noted in the initial setup. Verify that the Auto Tune feature is enabled in the menu settings. From the main operation screen, set the Set Point temperature. Press the TUNE button and the indicators showing Tune and Heat will be illuminated on display. The Set Point value can not be altered after the Tune process has started. The value is locked until the Tune process is complete or aborted by the user. Stopping the Tune operation prior to it finishing will cause the PID settings to be returned to the factory default values. PID values will be saved in nonvolatile memory. For complete information, reference the User Manual. 5

1065DGMAN_TC9000_b 6 08/2014 Rev. 1