ELECTRIC CENTRAL HEATING FLOW BOILER

Similar documents
KOSPEL S.A. UL. OLCHOWA KOSZALIN

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

INSTALLATION & TECHNICAL MANUAL

INSTALLATION AND OPERATION MANUAL

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

DIGITAL MODULATING BOILERS

DOMESTIC HOT WATER Follow operational sequence

MAINTENANCE AND SERVICE GUIDE

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

Unvented Electric Water Heater 10/15 litre Undersink

INSTALLATION & TECHNICAL MANUAL

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

FIL-SPL Flow-through heater for central heating USER MANUAL

SLIM-LINE RC FAN CONVECTOR.

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Electric Flow Boiler

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Operating instructions

Operating and assembly manual: Electric instantaneous flow heater Admiral

Instantaneous water heater - Operation and installation instructions

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE CONTROL

Mikrofill Ethos Condensing combination boiler

Instruction Manual. Orayonne. Glass radiation heater

Operating instructions

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER WITH RELAY CONTROL

HOTFLO 10 / 15. Fitting Instructions and User Guide

Installation Instructions VITOTRONIC 300

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

ELECTRIC WATER HEATER HT382E55

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Installation and User Instructions HS10U, HS15U.

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

Open Vented Condensing Boilers

Settings and Maintenance of the CombinAir

Installation and operation manual for mixing modules FH-MJB and FH-MJC

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Operating instructions

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Metering systems 0548EN April 2014

Contact Details. Please note that some of the contact details on this PDF document may not be current.

USERS GUIDE. LOGIC+ Combi 24, 30, 35

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

TECHNICAL PROPERTIES OF THE APPLIANCE

Alpha CombiMax 350 and 600

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

TH100 Three in One Instant Hot Water Tap

Installation, operating and servicing instructions

PANTHER. Condensate removal pump Installation and operating guide

Model: Available in: Sapphire Black and Glacier White. 1 Series

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

DC740 Built-under & DC940 Built-In

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

/2010 US/CA

USERS MANUAL FOR GAS BOILERS

Installation Instructions VITOTRONIC 200

1592P01. for liquids in piping DN

Installation and technical manual

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

Operating Instructions

EUROFLAT SERIES TYPES C... S... M...

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

VL FOREVER 600 INOX - VL FOREVER 600

VIESMANN. Operating instructions VITODENS 100-W. for the system user

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

E35 CONVECTION OVEN SERVICE MANUAL

TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Description of functions

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Flow Factor ~

NIBE SPLIT ACVM 270 Air/water heat pump

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

NRG NRG NRG NRG

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

BOILER MODEL m³/h (31.5 ft³/h)

Hand Dryer Installation & User Manual

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

ST E /ST E / ST E / ST E ST E / ST E / ST E

Logic+ Combi

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Zen Boiling Tap Range

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

51AKB / 51 AKC OWNER S MANUAL

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Programmable Room Thermostat Installation Instructions

Transcription:

ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.A1

Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment for recycling. Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste. In order to get more detailed information about recycling this product you should contact the local govern ment unit, waste management service or the shop where this product has been purchased.

Safety instructions 1. Read and strictly follow the installation and operating instructions to ensure a long life and reliable boiler operation. 2. An efficient electrical installation which has been completed in accordance with the binding norms of electric installation. 3. A wet central heating system equipped with appropriate expansion vessel made according to the binding norms of hydraulic installation. 4. A wet central heating system must be flushed before boiler installation. 5. Do not install any barrier fittings (e.g. valves) on the outlet of the safety valve. 6. Boiler must not be installed in a humid place or in a place exposed to the danger of explosion. 7. Boiler installation and all electrical and hydraulic work must be performed by a qualified professional installer only. 8. All installation work must be performed when the power and water supply is cut off. 9. Electric installation should be equipped with residual current protective devices and other solutions which will ensure disconnecting the heater from the source of power (intervals between all their poles should not be less than 3 mm). 10. Do not cut off the power supply between the heating seasons. Despite the knob is set in OFF position, the boiler will start the pump every 24 hours for 90 seconds to protect the installation. 11. Do not drain the water from central heating system after the heating season. 12. Before the heating season boiler should be checked by the service point. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. GB-0 3

Installation C 1. In order to take off the front cover, undo the fixing screws and disconnect the protective wire. For fixing the unit permanently leave free space at the top and bottom for access tool to unscrew the screws. 2. Hang the boiler up in a vertical position on fixing screws with the inlet and outlet pipes to the bottom. 3. Connect the boiler to a central heating system equipped with cut-off valves. 4. Fill the central heating system with a treated water that substantially extends the life of the heating elements. 5. Vent the wet central heating system. 6. Connect a boiler to the electric mains. Boilers of 4 and 6kW are factory preset to work as single phase boilers. If you intend to connect a boiler to the three-phase electrical sys tem, take off the wire set [2]. 7. Fix the room thermostat, in accordance with its manual. 8. Connect the room thermostat (by using two wires 2 x 0,35 mm 2 ) to the (RT entry) on controller. In order to insert the wires to the clamps, you have to press the switch on the connecting element with a use of a screwdriver. 9. Once you have finished the above procedures, you can start the boiler according to start-up section. D C D M4x8 M4x8! Make sure that the room thermostat connection is a voltage free one! The RT connection is a voltage free connection! Connecting voltage will destroy the controller. 4

1 1 2 L N L N Connection to the three phase system. PNL - points of neutral and protective conductor connection PF - points of phase conductors connection. [1] - temperature limiter (for 4, 6kW boilers, take off the [2] wire set) Connection to the single phase system PNL - connection points of neutral, protective and phase conductor [1] - temperature limiter [2] - additional conductor (for single phase system only) Central heating installation diagram PI - manometer ZK - cut-off valve F - magnetic filter RW - expansion pipe NW - expansion vessel ZT - thermostatic valve ZP - passage valve G - radiator RTP - room thermostat ZU - differential pressure relief valve (bypass) PO - circulating pump A magnetic filter must be installed on return pipe of central heating installation system (before boiler inlet). The filter must be installed in horizontal position, accordingly to flow direction (see arrow on the filter body), with the magnetic insert chamber to the bottom. GB-0 5

Connection of external appliances [3] - RT- Room Thermostat contacts entries [4] - Pump- Circulating Pump entry [5] - LED- Room Thermostat on, signal [6] - Pump LED - Pump on, signal [7] - Set up switches a) - Pump mode working mode of the pump b) - JP3 unused c) - JP4 unused [8] - front panel connection [9] - Water - water in boiler signal 8 7 9 5 There is a boiler controller to which a number of external appliances can be connected and the controller working modes can be set. Additionally, it signals some modes that help to the initial start up and checking correct operation of the boiler. 1. A room thermostat should be connected to the boiler through the RT [3] entries. When the connections are opened, the boiler will recognise that the required temperature in the room is reached. In this case the boiler will switch the heating off. LED [5] on the controller board signalises the room thermostat status. The [5] LED indicator illuminates when the thermostat connections are closed. 2. Pump. Use the [4] entries to connect a pump. The pump is powered by the fuse (1A delayed 230V) that is situated on the controller board with the use of connector. When the pump is running, the LED indicator [6] is also is illuminated. 3. Choosing the pump mode. There are set up switches on the control board to control the operating mode of the pump. Setting the switch to ON position changing the pump mode to constant work, despite the status of the room temperature connected to RT entry [3]. If the set up switch is in different position, the pump will operate in an automatic mode (i.e when the room temperature reaches the set limit of the room thermostat, the pump will be turned off RT connection closed). 6

Start-up 1. Connect the circulating pump according to the description in Connection of external appliances. 2. Set the pump mode switch to the On position. 3. Disconnect a room thermostat from RT entry [3]. 4. Set the knob [10] at any temperature e.g 50 degress.the boiler will start the pump but it will not start the heating. 5. Vent the installation and the pump according to the pump manual. 6. Check the flow in the installation by the use of some proper devices (e.g rotameter) if necessary get rid of the reason of lack of flow. 7. Set the knob [10] in the OFF position. 8. Connect the room thermostat and set the pump mode according to Connection of external appliances. 9. Turn the boiler on. Front control panel operation Control panel is located on the outside boiler cover. It consists of (on-off knob,and temperature control [10], 4 signalling LED indicators [11], [12], [13] green and one [14] red. LED indicators are specified on page 8. In order to start the boiler, set the knob [10] at desire temperature. To switch the boiler off, set the knob [10] in OFF position. Switching off procedure will be confirmed by the flashing green indicator [11]. At this time the heating elements are turned off but the pump will still run for 90 seconds. After this time the green indicator [11] goes off and the boiler is fully off. 11 12 13 14 30 0 40 OFF 10 GB-0 7

Signals Turn on Heating A room thermostat Fault light off light off light off light off Boiler OFF. light on light off light off light off Boiler on but does not heat, room thermostat does not allow for it. light on light on light on light off Boiler on and heats, a room thermostat sends heating signal. light off light off light off light on A failure: no water in the boiler. light off flashing light off light on A failure of the temperature sensor. If you can start the boiler up (boiler is heating) - a failure of inlet temperature sensor light on light off flashing light off Maximum inlet temperature is reached, no heat collection from C.H system flashing light off light off light off Boiler OFF but the pump is still working. Pump will switch off after 90 sec. 8

Technical data Max. pressure MPa 0,3 Min. pressure MPa 0,05 Out flowing water temp C 30 80 Max water temp. C 100 Overall dimensions (height x width x depth) mm 912 x 203 x 172 Weight kg ~11 Water connection mm 22 Safety class IP 22 Rated power consumption kw 4 6 4 6 8 Voltage 230V ~ 400V 3N~ Rated current A 17,4 26,0 3 x 5,7 3 x 8,7 3 x 11,7 Fuse rated current A 20 32 10 16 Min. connecting wires section mm 2 3 x 2,5 3 x 4 5 x 1,5 Max. connecting wires section mm 2 3 x 16 5 x 16 Max. allowed network impedance Ω 0,44 0,39 Rated power consumption kw 12 15 18 21 Voltage 400V 3N~ Rated current A 3 x 17,3 3 x 21,7 3 x 26,0 3 x 30,3 Fuse rated current A 20 25 32 40 Min connecting wires section mm 2 5 x 2,5 5 x 4 Max connecting wires section mm 2 5 x 16 GB-0 9

10

KOSPEL S.A. ul. Olchowa 1 75-136 Koszalin tel. +48 94 346 38 08 info@kospel.pl www.kospel.pl