CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Similar documents
CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

High temperature air-to-water heat pumps

Compact and silent Scroll compressors All-season operation

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Roof top SPACE RPC 450Z R407C M011

Aquaciat Free cooling

Roof top SPACE RPC 315Z R407C MA00

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AIR COOLED PACKAGED CHILLER

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Precision air handling cabinets Ciatronic MICRO/EXPAIR

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Aquaflair TRAC-TRAF-TRAH

Condensing Units CUS 15-60

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

LZA High efficiency air to water heat pumps with HP compressor

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30RB /30RQ

30RB /30RQ

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

30RH B Nominal cooling capacity kw Nominal heating capacity kw

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Air Cooled Chillers & Heat Pumps WinPACK HE-A

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Vertical self-contained air conditioner

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

MAC N-407 Air-Cooled Chiller

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

MACH N-407 Heat Pump Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

LZT High efficiency air to water heat pumps with E.V.I. compressors

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

CENTRAL SPLIT UNIT UNIC

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Commercial High-Efficiency Condensing Units

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

.2 Section Waste Management and Disposal.

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

HT V2 HT Split

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Precise Temperature Control; Compact Footprint

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Transcription:

Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary or industrial process fields. Its distinguishing feature is its remarkable acoustic characteristics. Streamlined fan blades, low speed, compressors mounted outside the air flow, on anti-vibration mounts as standard. All the components are mounted on a steel frame with large removable panels to ease maintenance operations. These are designed to be connected to a direct expansion exchanger such as: Air handling unit coils. Remote chilled water evaporators : coaxial type, shell and tube type or EXEL brazed plates type. The whole range integrates the lastest technological innovations and meets following expectations: Silence. Respect of environment. Simplicity of installation and reliability. AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A 1

DESCRIPTION The basic design of follows that of AQUACIAT LD chillers. The Unit conforms to norms EN 60-204 - EN 378-2 and conforms to directives : 98/37 CEE CEM 89/366/CEE modified 92/31/CEE - 93/68/CEE DESP 9723 CEE BT 73/23 CEE modified 93/68/CEE Hermetic scroll compressors Motor cooled by suction gas. Internal motor protection by winding sensor. Mounted on resilient mounts. Air cooled condenser Copper pipes and mechanicallly bonded aluminium fins coils. Direct drive propeller fan(s) streamlined blades 2 speed motor - IP 55, class F. Coil protection grid (models 80 to 300) Control and safety devices HP safety by manual reset pressostats. LP safety : by automatic pressure switch pressure control allowing an operation down to 15 C outside : by automatic HP pressure switch Short cycle protection Terminal strips for remote capacity control (compressors) Automacity control on terminals Electrical box The entire electrical assembly box, containing all the electrical components, allows for complete control of the machine in relation to the commands received by the capacity control of the installation (not provided). The electric box includes : Power circuit and remote control circuit, Wiring numbering, Main safety switch breaker on front panel with handle, Control circuit transformer, Circuit breakers protections on power and control circuits, Compressor(s) motor(s) contactor(s), Main earthing strip, Free contacts for field wiring signals report. OPTIONS High and low pressure gauge panel Coil treatment Polyurethane coated fins BLYGOLD POLUAL treatment Phase switch Soft starter Refrigerant circuit flexible connections kit OPERATING LIMITS EVAPORATION TEMPERATURE C Specific operating limits are defined for each model in the cooling capacities tables. Storage temperature or unit stopped : 50 C maxi. Mini Maxi CONDENSER AIR Mini Maxi 10 +10 TEMPERATURE C 15 +46 2 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A

TECHNICAL CHARACTERISTICS Standard version Low Noise version Compressor CD 100 V 120 V 150 V 180 V 200 V 240 V 300 V Cooling capacity (1) kw 25.6 28.3 37 44.1 49.9 57.7 73.2 Input power (2) kw 8.7 10 13 14 17 20 27 Cooling capacity (1) kw 24.3 26.7 34.4 41.6 45.6 55.7 70.2 Input power (2) kw 9.04 10.6 14.1 15.2 18.6 20.3 27.6 Type SCROLL Number 1 2 Rotation speed rpm 2900 R410A refrigerant charge kg No refrigerant (nitrogen charge) 1890 Capacity control % 100 0 100 50 0 Suction Number 1 circuit Balance circuit 1 / circuit 2 % 100 / 0 (low pressure) Evaporating temperature min./maxi C 10 / +10 Fans Helicoid direct drive Number of fans 1 x 800 Rotation speed STANDARD version 750 rpm Air cooled Air flow m 3 /h 16700 15500 16100 24000 condenser Motor unit power kw 1 x 0.9 1 x 1.7 Rotation speed LOW NOISE version 500 rpm Air flow m 3 /h 10800 9700 10800 18000 Motor unit power kw 1 x 0.46 1 x 1.2 Standard version Lw / Lp (3) db(a) 80/49 80/49 81/50 86/54 88/56 Low Noise version Lw / Lp (3) db(a) 75/44 77/46 78/47 81/49 83/51 CD 350 V 400 V 500 V 540 V 600 V 700 V Standard version Cooling capacity (1) kw 87.9 97.8 121 124 144 164 Input power (2) kw 29 35 42 46 53 61 Low Noise version Cooling capacity (1) kw 85.6 93.8 116 120 138 159 Input power (2) kw 30.7 35.5 43.6 47 54.9 62.3 Type SCROLL Number 2 4 Compressor Rotation speed rpm 2900 R410A refrigerant charge kg No refrigerant (nitrogen charge) - 1890 Capacity control % 100 43 0 100 37 0 100 50 0 100 72 50 22 0 100 75 50 25 0 100 78 50 22 0 Suction Number 1 2 circuit Balance circuit 1 / circuit 2 % 100 / 0 50 / 50 (low pressure) Evaporating temperature min./maxi C 10 / +10 Fans Helicoid direct drive Number of fans 2 Rotation speed STANDARD version 900 rpm Air cooled Air flow m 3 /h 44000 42000 41000 44000 condenser Motor unit power kw 2 x 1.7 2 x 1.8 2 x 1.7 Rotation speed LOW NOISE version 750 rpm Air flow m 3 /h 32000 29000 30500 35000 Motor unit power kw 2 x 1.2 2 x 1.1 Standard version Lw / Lp (3) db(a) 89/57 90/58 91/59 Low Noise version Lw / Lp (3) db(a) 83/51 85/53 (1) Cooling capacity based on +2 C evaporating temperature and 35 C outdoor air temperature (2) Input power (compressors + fan motors) (3) Lw : Total acoustic power level Lp : Total acoustic pressure level free field at 10m from unit 1.50m from ground ISO 3744 ELECTRICAL CHARACTERISTICS Main electric supply Control voltage CD 100V 120V 150V 180V 200V 240V 300V 350V 400V 500V 540V 600V 700V 3 ph - 50 Hz - 400 V (+6%/ 10%) + Earth 1 ph - 50 Hz - 230 V (+6%/ 10%) - Mounted transformer Starting current A 118 135 198 130 143 149 230 256 303 320 276 286 325 SOFT START option starting current A 70 81 118 83 90 104 146 163 191 209 144 202 237 Breaking capacity (in neutral TN NN) ka 15 10 15 10 10 35 10 Maxi wires section mm 2 10 35 70 50 95 Maxi running current (1) A 22.7 24.8 30.9 33.0 43.4 49.6 60.0 72.0 82.0 104.0 110.0 120.0 138 (1) Current for wires design AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A 3

DIMENSIONS 100 150 4 removable lifting lugs holes 20.5 Handling wooden wedges to be withdrawn when positioning the unit Exernal air intake External air discharge CD 100 120 150 E = 80 Suction S = 1" 3/8 1" 5/8 Liquid L = 7/8" Mass kg empty 290 350 10 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A

DIMENSIONS 180 300 4 removable lifting lugs holes 20.5 Handling wooden wedges to be withdrawn when positioning the unit Exernal air intake External air discharge CD 180 200 240 300 E = 80 Suction S = 1" 5/8 2" 1/8 Liquid L = 1" 1/8 Mass kg empty 460 465 575 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A 11

DIMENSIONS 350 500 Handling wooden wedges to be withdrawn when positioning the unit Exernal air intake External air discharge 4 removable lifting lugs holes 20.5 CD 350 400 500 E = 60 Suction S = 2" 1/8 2 x 2" 1/8 Liquid L = 1" 1/8 2 x 1" 1/8 Mass kg emtpy 983 1082 1090 12 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A

DIMENSIONS 540 700 Handling wooden wedges to be withdrawn when positioning the unit 4 removable lifting lugs holes 20.5 Exernal air intake External air discharge CD 540 600 700 E = 60 Aspiration S = 2 x 2" 1/8 Liquid L = 2 x 1" 1/8 Mass kg empty 1360 1499 1676 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A 13

FIXATION OF CHASSIS TO THE GROUND CD 100 V to 300 V CD 350 V to 700 V The fixation of chassis to the ground is possible (mounts with bolts not supplied by CIAT) hardness to be defined according to the weight and gravity center of the unit. CD 100V 120V 150V 180V 200V 240V 300V 350V 400V 500V 540V 600V 700V L1 316 281 405 L2 316 281 281 L3 1540 2185 2735 L4 1044 2123 2123 RECOMMENDATIONS FOR INSTALLATION Location CD series CONDENCIAT are designed to be positioned outside, on the ground or on the roof. In all cases, access to the must be made easy to carry out connections and maintenance. Provide a clearance of 1 to 1.5 metres around the unit. No obstacles should block the air intake on the coil and at the fan outlet. Study the installation of the unit carefully, choose a location that is compatible with the environmental requirements (noise level, integration on site, etc.). Electrical connections These must be made in compliance with the current regulations and standards and in compliance with the electrical diagram and the instructions in the maintenance manual. Work to be performed on site: Connect the power supply, power, earth connector to the input terminals. Make the respective connections between the thermostat, electrical valve, external safety device, etc., and the corresponding connection terminals on the electrical panel. Note : The output of the power lines must be equipped with an isolating switch or a motor circuit breaker (to be provided for by the installer). Importnant : When the unit is in operation, the electrical cabinet must always be switched on to enable, during shut down, the compressor casing to be heated and thus make the next start-up easier. For the first start-up, or following a prolonged shut down, the electrical cabinet should be switched on several hours before the unit is started up. Refrigeration connections The work is to be performed according to the strictest professional standards and generally includes: Thorough study of the line (slope, trap or diameter) for an easier oil return to the compressor. Fitting of refrigeration lines between the coil and CONDENCIAT, intake and fluid pipes. Fitting of refrigeration accessories on the direct expansion coil (pressure reducing valve, electrical valve). For CIAT supplies and services, this equipment is fitted in the workshop. The length of the connections between the equipment must always be as short as possible (maximum developed length : 15 m including 6 m of slope). In the event of doubt, contact our technical departments. Insulation of the intake pipe. Vacuum draining of the circuit, loading and start-up. The assembly of the condensing group, connecting piping and evaporator must be carried out in conformity with the European directive concerning the equipments under pressure (DEP) N 97/23/CE. The CIAT condensing unit and evaporators conform to this directive. The must be connected by antivibratil sleeves (supplied by CIAT as an option). Maintenance Comply with the maintenance manual. Take out a maintenance contract. 14 AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 08.542 A