Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Similar documents
Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

395CAV Sizes 045 thru 155 Series H and J

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 58WAV Weathermaker 8000 High-Efficiency Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. 58UHV, 58UXV WeatherMaker 8000VS with Comfort Heat Technology Upflow/Horizontal Furnace. Input Capacities: 60,000 thru 120,000 Btuh

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data. 58TUA WeatherMaker Speed High-Efficiency Upflow Furnace. Input Capacities: 40,000 thru 135,000 Btuh

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data STANDARD FEATURES

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

355MAV Sizes 040 thru 120 Series E

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

RG7D 1-Stage Heat Series

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL SPECIFICATIONS

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Wt. Lbs Model Number (BTUH) Hz

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Product Data. IdealComfortt technology, the ultimate in heating comfort...

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

MERIT SERIES Downflow

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Upflow/Horizontal Condensing, Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

TSTAT0201CW Recommended (sold separately)

Product Data. FH4A Fan Unit. Sizes 001 thru 004

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Transcription:

Product Data 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace Series 50 and 60 Input Capacities: 45,000 thru 55,000 Btuh Advanced Technology for Energy-Efficient Gas Furnaces Carrier leads the industry with its new WeatherMaker 8000 Induced- Draft Gas Furnace. This furnace is built with the most advanced manufacturing equipment, processes, and technology available in order to ensure top quality. Packed into the cabinet are the industry s foremost dealer and homeowner features. All models are GAMA efficiency rating certified and certified for use in California Air Quality Management Districts. These induced-combustion, gas-fired furnaces offer not only low installation costs, but fuel economy as well delivering an Annual Fuel Utilization Efficiency (AFUE) rating of 80.0 percent. The Carrier WeatherMaker 8000 utilizes a hot surface, silicon carbide ignition system to save energy and increase reliability. Our design uses the patented S-shaped 4-pass heat exchanger, a soft mount inducer assembly, and a slow opening gas valve to improve sound level. The Super-S heat exchanger provides better heat transfer while enabling us to make a compact furnace. This provides more room in closet, utility room, and short basement installations. The heat exchanger is constructed of aluminized steel and is backed by a 0-year Limited Warranty. The Carrier WeatherMaker 8000 Gas Furnace will meet your home heating requirements. This furnace family provides the widest range of heating capacities available. The superior attention to cabinet detail is obvious. The Carrier WeatherMaker 8000 features -piece, Copyright 000 Carrier Corporation Form No. 58WAV-9PD

L L P R PR 90 P S TA P3 3 6 9 5 8 L PR COM SEC- SEC- COOL SPARE- HEAT SPARE- 365 SW BLOWER OFF DELAY P5 TEST LED 3 HUM C W Y R G HUM COM W Y R G 4V 9404 4 7 S EC S EC U S E 3 A E AC E AC seamless, wrap-around construction. There are no spot welds on the exterior surfaces of the WeatherMaker 8000 Furnace. There is also double protection for the cabinet. First, a galvanized steel substrate provides resistance to rusting. Then the cabinet is constructed of prepainted steel the same high-quality finish found on refrigerators and dishwashers. Perhaps the most advanced feature of the WeatherMaker 8000 is the microprocessor control board. The simplified electronics in this control board provide high reliability while performing many of the functions of older, electro-mechanical devices in other furnaces. Advanced features of the board show true leadership in furnace technology. The control board provides blower delay at start-up and shutdown, while monitoring furnace operations and functions. In the unlikely event of a service call, in less than a minute, the technician can use the self-test feature to determine if a major component has failed. The control board will check itself, then the inducer, silicon carbide ignition, low- and highspeed blower, and the humidifier connections. The control board also features a 3-amp fuse that protects the transformer and control board. Another feature on the control board is an LED status indicator light to ensure top furnace performance. Our induced-combustion furnace has a patented draft safeguard switch. The draft safeguard switch will stop furnace operation if the vent system becomes blocked or is not operating properly. Enhanced indoor air quality in your home is made easier with our media filter cabinet a standard accessory on all deluxe upflow furnaces. When installed as a part of your system, this cabinet allows for easy and convenient addition of a Carrier high-efficiency air filter. Best of all, the Carrier Weather- Maker 8000 is made to be easily installed. Many features make this furnace the easy choice for replacement or new construction markets. Left and right connections are provided for gas and electrical supplies. An easy-toremove bottom, blower speed selector, cased or uncased cooling coils, lowvoltage humidifier, and electronic air cleaner terminal connections are among other features. WARNING UNITED TECHNOLOGIES ELECTRONIC CONTROLS BLOWER-OFF SERVICE HUNTINGTON, IN 46750 DELAY FURNACE CONTROL SWITCH SETTING 0-940 MODEL HK4FZ0 FOR USE WITH ALL GASES INPUT - 4VAC, 465 ma, 60Hz ANSI Z.0-993 35 80 5 HUM C W Y R G CAN/CSA - C. NO. 99-M89 SEE SEPARATE LED STATUS CODE LABEL FOR INSTRUCTIONS ON CONDUCTING COMPONENT TEST AND READING STATUS CODES FROM LED. P I 3 L3 ND F PL T US T EST C P L OM R LINE VOLTAGE NEUTRAL HEAT COOL BLOWER SPARE SPARE MOTOR LINE VOLTAGE 0 VAC P L H S A897 A945 A9074 HEAT EXCHANGER CONTROL BOARD INDUCER BLOWER Model number nomenclature High-Efficiency Induced-Combustion Upflow Furnace Input Capacity 045 44,000 Btuh 0,000 Btuh 070 66,000 Btuh 36 3,000 Btuh 09 88,000 Btuh 55 54,000 Btuh 58WAV 045 50 08 Nominal Cooling Size (Airflow) (400 CFM per,000 Btuh) 08 800 CFM 00 CFM 4 400 CFM 6 600 CFM 0 000 CFM Series Number

9 3 4 5 6 7 8 ;; ;; ; 0 A9806 NOTE: The 58WAV Furnaces are for use with natural gas. These furnaces can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. NOTE: Control location and actual control may be different than shown above. Inducer Assembly 7 Pressure Switch 8 3 Gas Control Valve 9 4 Burner Assembly 0 5 Blower Door Safety Switch 6 Control Board Air Filter Retainer Air Filter Wrap-Around Casing Draft Safeguard Switch Heat Exchanger Blower and Blower Motor 3

Carrier accessories* A9743 CONTROLS: THERMOSTATS AND ZONING Available in programmable and non-programmable models, Carrier thermostats maintain a constant comfortable temperature level in the home. For the ultimate in home comfort, Carrier s, 4, and 8-zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4-zone system is shown. A97380 MECHANICAL OR ELECTRONIC AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. MODEL HUMCCLFP HUMIDIFIER A9365 By adding moisture to winter-dry air, a Carrier humidifier can often improve the comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. UNIT SIZE 045-08 & 070-08 & 09-4 & 6 -, 6 & 0 36-6 & 0 55-0 ELECTRONIC AIR CLEANER (EAC) Model AIRA MECHANICAL AIR CLEANER Model 3MF HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Models HRVCCLHU, HRVCCSVU, or HRVCCLVU ENERGY RECOVERY VENTILATOR Models ERVCCLHU, ERVCCLVU, or ERVCCSVU Auto Changeover, F/ C, -Stage Heat/-Stage Cool TSTATCCNAC0-B Auto Changeover, F/ C, -Stage Heat/-Stage Cool TSTATCCNHP0-B THERMOSTAST NON-PROGRAMMABLE Auto Changeover, F/ C, -Stage Heat/-Stage Cool TSTATCCNS0-B in AC Mode, 3-Stage Heat in AC Mode/-Stage Cool in HP Mode Air Conditioner, -Stage Heat/-Stage Cool, Manual Changeover, F/ C TSTATCCBAC0 Heat Pump, -Stage Heat/-Stage Cool, Manual Changeover, F/ C TSTATCCBHP0** THERMOSTAT PROGRAMMABLE ZONING ZONE ZONING 4 ZONE ZONING 8 ZONE TWINNING KIT GAS CONVERSION KIT* NATURAL-TO-PROPANE PROPANE-TO-NATURAL * Factory-authorized and field installed. Gas conversion kits are CSA (A.G.A. and C.G.A.) recognized. 6 and 0 sizes only. ** Do not use in zoning heat pump applications. Auto Changeover, 7-Day Programmable, F/ C, -Stage Heat/-Stage Cool TSTATCCPAC0-B Auto Changeover, 7-Day Programmable, F/ C, -Stage Heat/-Stage Cool TSTATCCPHP0-B Auto Changeover, 7-Day Programmable, F/ C, -Stage Heat/-Stage Cool TSTATCCPS0-B in AC Mode, 3-Stage Heat/-Stage Cool in HP Mode Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor TSTATCCPDF0-B** Thermidistat Control Non-Programmable/Programmable Thermostat TSTATCCPRH0-B** with Humidity Control (For use in Dual Fuel, AC, HP, and S applications. Includes Outdoor Air Temperature Sensor.) ZONECCKIT0, ZONEKITZCAR ZONECC4KIT0 B ZONECC8KIT0 B KGATW040HSI KGANP00ALL KGAPN60ALL 4

Physical data UNIT SIZE 045 070 09 36 55 08 08 4 6 6 0 6 0 0 OUTPUT CAPACITY (BTUH) Nonweatherized ICS 35,000 35,000 53,000 53,000 7,000 7,000 89,000 89,000 89,000 07,000 07,000 4,000 INPUT BTUH* 44,000 44,000 66,000 66,000 88,000 88,000 0,000 0,000 0,000 3,000 3,000 54,000 SHIPPING WEIGHT (Lb) 4 3 34 50 54 60 66 84 79 94 04 CERTIFIED TEMP RISE RANGE ( F) 5-55 5-45 40-70 30-60 40-70 30-60 55-85 45-75 5-55 50-80 40-70 50-80 CERTIFIED EXT STATIC PRESSURE Heating 0.0 0.0 0. 0. 0.5 0.5 0.0 0.0 0.0 0.0 0.0 0.0 Cooling 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 AIRFLOW CFM Heating 855 980 830 40 70 445 75 40 750 645 775 770 LIMIT CONTROL HEATING BLOWER CONTROL Cooling 880 50 880 95 360 740 05 575 5 60 05 055 * Gas input ratings are certified for elevations to 000 ft. For elevations above 000 ft, reduce ratings 4 percent for each 000 ft above sea level. Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 0 percent for elevations 000 ft to 4500 ft above sea level. Capacity in accordance with U.S. Government DOE test procedures. Airflow shown is for bottom only return-air supply with factory-supplied -in. washable filter(s). For air delivery above 800 CFM, see Air Delivery table for other options. An airflow reduction of up to 7% may occur when using the factory specified 4-5/6-inch wide, high efficiency media filter. For best furnace efficiency when using the 4-5/6-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. ICS Isolated Combustion System SPST Solid-State Time Operation BURNERS (Monoport) 3 3 4 4 5 5 5 6 6 7 GAS CONNECTION SIZE GAS VALVE (Redundant) Manufacturer Minimum Inlet Pressure (In. wc) Maximum Inlet Pressure (In. wc) IGNITION DEVICE /-in. NPT White-Rodgers 4.5 (Natural Gas) 3.6 (Natural Gas) Hot Surface Performance data 045 070 09 36 55 UNIT SIZE 08 08 4 6 6 0 6 0 0 DIRECT-DRIVE MOTOR Hp (PSC) /5 /3 /5 /3 /3 / /3 / 3/4 / 3/4 3/4 MOTOR FULL LOAD AMPS.9 5.8.9 5.8 5.8 7.9 5.8 7.9. 7.9.. RPM (Nominal) SPEEDS 075-3 075-4 075-3 075-4 075-4 075-4 075-4 075-4 075-4 075-4 075-4 075-4 BLOWER WHEEL DIAMETER x WIDTHS (In.) 0 x 6 0 x 6 0 x 6 0 x 6 0 x 7 0 x 8 0 x 7 0 x 8 x 0 0 x 8 x 0 x 0 WASHABLE 6 x 5 x -In. FILTER Qty WASHABLE 0 x 5 x -In. FILTER Qty WASHABLE 4 x 5 x -In. FILTER Qty PSC Permanent Split Capacitor ENERGY EFFICIENCY UNIT SIZE 08 08 4 6 6 0 6 0 0 CAPACITY BTUH* Nonweatherized ICS 35,000 35,000 53,000 53,000 7,000 7,000 89,000 89,000 89,000 07,000 07,000 4,000 AFUE%* Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 * Capacity and AFUE in accordance with U.S. Government DOE test procedures. ICS Isolated Combustion System 045 070 09 36 55 5

UNIT SIZE 045-08 045-070-08 070-09-4 09-6 - -6-0 36-6 36-0 55-0 AIR DELIVERY CFM (With Filter)* EXTERNAL STATIC PRESSURE (In. wc) RETURN-AIR SUPPLY SPEED 0. 0. 0.3 0.4 0.5 0.6 0.7 0.8 High 030 005 970 95 880 85 745 65 or Med-High 855 830 800 765 70 670 595 485 Side Med-Low 755 75 695 650 605 555 475 400 High 490 430 385 35 50 75 085 975 or Med-High 335 305 70 30 60 090 005 95 Side Med-Low 40 30 05 075 030 975 900 830 Low 980 975 965 95 875 840 785 75 High 040 00 975 935 880 80 735 640 or Med-High 855 830 800 765 75 660 600 490 Side Med-Low 745 75 690 650 605 550 475 385 or Side or Side or Side or Side or Side Only Both Sides or Side & Side Only or Side Only Both Sides or Side & Side Only Only Both Sides or Side & Side Only High 430 380 35 65 95 5 045 945 Med-High 30 75 35 90 35 065 990 900 Med-Low 40 30 00 065 000 965 90 85 Low 990 965 960 935 905 855 800 70 High 570 535 480 45 360 80 85 070 Med-High 370 355 330 90 40 70 080 955 Med-Low 70 65 50 5 085 035 970 880 Low 00 005 990 965 950 905 845 745 High 00 950 875 80 740 660 550 455 Med-High 675 660 65 600 545 490 395 95 Med-Low 445 430 45 400 370 35 65 70 Low 60 60 60 50 0 80 5 030 High 470 45 340 70 05 5 985 845 Med-High 340 305 45 85 30 045 95 780 Med-Low 85 75 40 075 030 950 835 705 Low 05 00 980 955 90 840 75 600 High 880 85 745 690 575 500 400 65 Med-High 660 65 570 505 435 355 60 70 Med-Low 455 40 375 350 90 35 45 985 Low 65 65 40 0 80 0 995 855 High 465 385 305 5 5 00 90 Med-High 5 0 075 040 985 900 85 75 Med-Low 745 750 740 70 685 635 565 500 Low 545 545 545 50 495 450 390 330 High 475 465 45 365 305 30 45 05 Med-High 00 080 075 055 05 940 865 765 High 45 340 50 70 070 000 890 780 Med-High 080 050 00 955 885 805 745 645 High 900 845 780 705 60 530 445 30 Med-High 695 645 580 50 460 385 80 55 Med-Low 460 45 375 340 90 05 0 Low 75 60 45 30 80 35 High 60 85 085 05 935 835 730 Med-High 0 070 05 960 885 80 75 60 Med-Low 790 775 755 70 670 60 535 455 Low 495 500 55 485 450 400 345 70 High 45 360 75 95 095 00 890 775 Med-High 055 035 995 945 880 80 735 640 High 45 75 070 980 900 805 695 575 Med-High 050 985 95 850 765 690 585 480 High 300 35 55 055 980 870 775 Med-High 050 005 945 880 805 70 640 Med-Low 790 770 740 70 635 580 50 440 Low 50 55 505 485 450 40 350 90 High 405 385 30 0 40 045 945 85 Med-High 090 090 040 990 95 850 765 660 High 35 60 75 085 000 900 805 705 Med-High 085 045 985 90 855 765 680 570 * A filter is required for each return-air supply. Airflow shown is with factory supplied -in. washable filter(s). An airflow reduction of up to 7% may occur when using the factory specified 4-5/6-inch wide, high-efficiency media filter. For best furnace efficiency when using the 4-5/6-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. Indicates unstable operating conditions. 6

Dimensions AIRFLOW 8 VENT CONN 6 A D 3 6 6 9 OUTLET 3 6 7 8-IN. DIA HOLE POWER ENTRY 7 8-IN. DIA ACCESSORY 5 3 8 5 6 5 3 6 5 3 8 6 5 3 6 7 8-IN. DIA POWER ENTRY -IN. DIA R.H. GAS ENTRY 39 7 8 3 4-IN. DIA HOLE GAS ENTRY -IN. DIA HOLE THERMOSTAT WIRE ENTRY 3 8 3 8 7 8-IN. DIA ACCESSORY -IN. DIA THERMOSTAT WIRE ENTRY SIDE INLET SIDE INLET 4 6 NOTES: 4 5 6 AIR INLET 3 6. Two additional 7 8-in. dia holes are located in the top plate.. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. 3. Minimum return-air opening at furnace: a. For 800 CFM 6-in. round or 4 x -in. rectangle. b. For 00 CFM 0-in. round or 4 x 9 -in. rectangle. c. For 600 CFM -in. round or 4 x 3 4-in. rectangle. d. For airflow requirements above 800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 800 CFM. E 6 TYP 5 8 TYP 3 4 SIDE RETURN DUCT LOCATION 4 A9850 DIMENSIONS (In.) UNIT SIZE A D E VENT CONN* (Dia) 045-08 4-3/6-9/6 -/6 4 045-4-3/6-9/6 -/6 4 070-08 4-3/6-9/6 -/6 4 070-4-3/6-9/6 -/6 4 09-4 7-/ 5-7/8 6 4 09-6 9-3/8 8-/ 4-7-/ 5-7/8 6 4-6 9-3/8 8-/ 4-0 4-/ -7/8 4 36-6 9-3/8 8-/ 5 36-0 4-/ -7/8 5 55-0 4-/ -7/8 5 * Refer to the furnace Installation Instructions for proper venting procedures. Oval collar 7

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION his forced air furn ace is equipped for use with This furnace is approved for UPFLOW installations only. natural gas at altitudes 0-0,000 ft (0-3,050m). n accessory kit, supplied by the manufacturer, " s all be used to convert to propane gas use or m y be required for some natural gas applications. his furnace is for indoor installation in uilding constructed on site. 0" " his furnace may be install ed on combustible B A C # K flooring in alcove or closet at minimum clearance fr m combustible material. his furnace may be used with a Type B- Vent and may be vented in common with other gas-fired S E RVI a pliances. # # For furnaces wider than 4.5 inches (36mm) may be 0 inches. For single wall vent type 6 inches. For Type B- vent type 3 inches. " # S I D E TOP / PLENUM BOTTOM DESSOUS Clearance in inches. 3035-0 REV. H Vent Clearance to combustibles: For Single Wall vents 6 inches (6 po). For Type B- vent type inch ( po). 0" F URNACE F RONT F RO N T ## S I DE C E 30" MIN A98E ama CERTIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. REGISTERED QUALITY SYSTEM Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. 8

Typical wiring schematic FIELD 4-V WIRING FIELD 5-, 08/30-, 460-V WIRING FACTORY 4-V WIRING FACTORY 5-V WIRING FIVE WIRE NOTE W C R G Y THERMOSTAT TERMINALS FIELD-SUPPLIED FUSED DISCONNECT BLK BLK THREE-WIRE HEATING- ONLY W 08/30- OR 460-V THREE PHASE WHT GND WHT 5-V FIELD-SUPPLIED DISCONNECT GND G AUXILIARY J-BOX C CONTROL BOX Y 4-V TERMINAL BLOCK FURNACE R NOTE NOTES:.. 3. CONDENSING UNIT TWO WIRE GND 08/30-V SINGLE PHASE Connect Y-terminal as shown for proper operation. Some thermostats require a "C" terminal connection as shown. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A9809 Electrical data UNIT SIZE 045-08 045-070-08 070-09-4 09-6 - -6-0 36-6 36-0 55-0 UNIT VOLTS HERTZ PHASE 5 60 MINIMUM WIRE SIZE 4 4 4 4 4 4 4 4 4 MAXIMUM WIRE LENGTH (Ft)* 47 34 47 3 3 7 35 8 3 8 33 3 MAXIMUM UNIT AMPS 6.0 8.3 5.9 8.7 9.0 0.4 8.0 0. 4.4 0. 3.3 4.0 OPERATING VOLTAGE RANGE (Min Max) 04 7 MAX FUSE OR CKT BKR (Amps) 5 5 5 5 5 5 5 5 0 5 0 0 TRANSFORMER (4v) EXTERNAL CONTROL POWER AVAILABLE Heating va AIR CONDITIONING BLOWER RELAY Cooling * Length shown is as measured way along wire path between unit and service panel for maximum % voltage drop. Permissible limits of the voltage range at which the unit will operate satisfactorily. Time-delay type is recommended. 40va 35va Standard 9

Typical installation CONDENSING UNIT HUMIDIFIER ELECTRONIC AIR CLEANER GAS-FIRED WATER HEATER AIRFLOW A894 0

Carrier Corporation Indianapolis, IN 463 0-00 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 Page Catalog No. 55-80004 Printed in U.S.A. PC 0 Form 58WAV-9PD Tab 6a 8a Replaces: 58WAV-8PD