Certificate of Compliance to IEC 61508

Similar documents
1510 Side Mounted Level Switch

CERTIFICATE OF COMPLIANCE

805QS Pressure Switch-Transmitter

Ultrasonic Point Level Switches

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

VIEW. Matters. Magnetic Level Indicators Series. with. indicator. The. 200º viewing angle. 200º viewing angle

Ultrasonic Switches. Features & Benefits

Proservo NMS5- / NMS7-

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

Product Guide Registered Quality System to ISO 9001:2008

Level gauges Series LS Level indicator, switch and transmitter for liquids

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

FlexES Control Flexible solutions with the modular fire detection system

Operating Instructions. For. Alarm Control Module. Model SSR 500

Process Instrumentation. Product Guide

Addendum for STI-6406 with Dual Access Control

Functional Safety Manual Oil Leak Detector NAR300 System

Roller/Plunger. Recessed Roller Plunger With Wire Leads Series. New Improved Design! SENTROL

APPROVAL REPORT. J.l. 3ZOA9.AX

Instrumentation and Controls Group

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) VOLUME - IIB. SPECIFICATION No: PES

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Electronic Flow Switches

PART NO. COMBUSTION AIR CAP

Flow Switch Replacement Parts

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

FMC(Z) cartridge filter

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Glass Tube Variable Area Flowmeter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Smart detection. Interlogix commercial sensors feature the latest technology to deliver advanced detection and accurate, reliable performance.

TrueAlarm Analog Sensing

Electronic Safety. Hazardous Location. By Jim Marquedant

Smart detection. Commercial Sensors

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Two-Position Electric Duplex Room Thermostats

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

STAND ALONE DRYER BASE. Parts Manual

TECHNICAL DATA OBSOLETE

INFORMATION BULLETIN NO: B-E

S P A C E D E T E C T I O N

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Ice Making Equipment Illustrated Parts Lists

PPA Michaël GROSSI - FSCE PR electronics

PRODUCT LINE QUICK REFERENCE. Worldwide Level and Flow Solutions SM

Worcester Controls PS/PM Series UltraSwitch. Switchbox

UV Flame Detector. User's and Maintenance Manual TM20/20UB Rev E, August 2004

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

IS Series Pressure Sensing Switches

FLAKER/DCM SEQUENCE OF OPERATION

Commercial and Light Industrial Fire Alarm Control Panel

LumiNotify Automated Light Intensity Measurement for Visual Notification Appliances ELECOMP Capstone Design Project

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

ue short form catalog Leaders in Safety, Alarm & Shutdown

TECHNICAL DATA. 319a. January 27, 2012

Ultra Fast UV/IR Flame Detector

PULL STATION SERIES DIE-CAST METAL MANUAL PULL STATIONS

SharpEye 20/20I. Triple IR (IR 3 ) Flame Detector. User's and Maintenance Manual

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Safety Light Curtains Area Access Control

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS

Installation and Operating Instructions

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

Hardwired Alarm Accessories

Duct Smoke Detector - D4120

SWK1323AL101 H2 Keylock

AUTOMATED PRODUCTION SYSTEMS, INC Pine Road Huntingdon Va l l ey PA P h o n e : (215) FA X : (215)

ELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS

Direct reading flowmeters type RM

PART NO. COMBUSTION AIR TERMINATION CAP

Certificate of Compliance

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Rosemount 3490 Series

Tubular Industrial Process

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

INSTALLATION INSTRUCTIONS

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

Transcription:

FM Approvals Certifies herewith that the Mechanical Products (Safety Manual [Form 1538 (3.12) 2012 SOR Inc.]) SOR Inc 14685 W 105 th St. Lenexa, KS 66215 Complies with the relevant requirements of standards listed below: Standards Description Compliance IEC 61508-1 1997 Functional Safety of Electronic/Electrical/Programmable Part 1 Electronic Safety-Related Systems- General Requirements IEC 61508-2 2000 Functional Safety of Electronic/Electrical/Programmable Electronic Safety-Related Systems Part 2 And therefore IS DECLARED FIT FOR USE" IN A Low Demand SAFETY APPLICATION ( A Component with HFT 0) This certificate is subject to conditions of use presented in FM Approval Report Project ID # 0003044628 April 18, 2012 James E. Marquedant Approval Granted Group Manager, Electrical FM Approvals 1151 Boston-Providence Turnpike Norwood, MA 02062 0003044628 Mechanical Products

Displacer Operated Top-Insertion Tank Mounted Series 701, 702, 703, 704, 705, 706, 707, 708 Dry- Single High Alarm DPDT 2 0.66 1.10E-04 25 SPDT 2 0.68 8.78E-05 20 Low Alarm DPDT 2 0.70 9.88E-05 22.5 SPDT 2 0.72 7.68E-05 17.5 High Alarm DPDT 2 0.67 9.66E-05 22 SPDT 2 0.69 7.46E-05 17 Low Alarm DPDT 2 0.70 8.56E-05 19.5 SPDT 2 0.73 6.37E-05 14.5 High Alarm DPDT 2 0.67 1.10E-04 25 SPDT 2 0.69 8.78E-05 20 Low Alarm DPDT 2 0.70 9.88E-05 22.5 SPDT 2 0.73 7.68E-05 17.5

Displacer Operated Top Insertion Tank Mounted Series 730, 731, 732, 733, 734, 735, 736, 737 Dry- Dual High Alarm DPDT 2 0.68 1.76E-04 40 SPDT 2 0.71 1.32E-04 30 Low Alarm DPDT 2 0.70 1.65E-04 37.5 SPDT 2 0.73 1.21E-04 27.5 High Alarm DPDT 2 0.71 1.49E-04 34 SPDT 2 0.74 1.05E-04 24 Low Alarm DPDT 2 0.73 1.38E-04 31.5 SPDT 2 0.77 9.44E-05 21.5

Displacer Operated Tamperproof & Flanged Serviceable Chamber Series 740, 741, 742, 743, 801, 802, 803, 804 Dry- Single High Alarm DPDT 2 0.75 1.10E-04 25 SPDT 2 0.77 8.78E-05 20 Low Alarm DPDT 2 0.78 9.88E-05 22.5 SPDT 2 0.80 7.68E-05 17.5 Dual High Alarm DPDT 2 0.74 1.76E-04 40 SPDT 2 0.77 1.32E-04 30 Low Alarm DPDT 2 0.75 1.65E-04 37.5 SPDT 2 0.79 1.21E-04 27.5 Single High Alarm DPDT 2 0.76 9.66E-05 22 SPDT 2 0.79 7.46E-05 17 Low Alarm DPDT 2 0.79 8.56E-05 19.5 SPDT 2 0.82 6.37E-05 14.5 Dual High Alarm DPDT 2 0.76 1.49E-04 34 SPDT 2 0.80 1.05E-04 24 Low Alarm DPDT 2 0.78 1.38E-04 31.5 SPDT 2 0.82 9.44E-05 21.5 Single High Alarm DPDT 2 0.75 1.10E-04 25 SPDT 2 0.78 8.78E-05 20 Low Alarm DPDT 2 0.78 9.88E-05 22.5 SPDT 2 0.81 7.68E-05 17.5

Displacer Operated Top Insertion Tank Mounted Series 750, 751, 752, 753, 754, 755, 756, 757 Dry- Triple High Alarm DPDT 2 0.69 2.41E-04 55 SPDT 2 0.72 1.76E-04 40 Low Alarm DPDT 2 0.71 2.30E-04 52.5 SPDT 2 0.74 1.65E-04 37.5 High Alarm DPDT 2 0.72 2.02E-04 46 SPDT 2 0.76 1.36E-04 31 Low Alarm DPDT 2 0.74 1.91E-04 43.5 SPDT 2 0.78 1.25E-04 28.5

Float Operated Flanged Serviceable & Tamperproof Chamber Series 101, 102, 103, 104, 109, 121, 122, 123, 124, 201, 202, 203, 204, 205, 206, 207, 209, 221 Dry- Single High Alarm DPDT 2 0.72 1.23E-04 28 SPDT 2 0.74 1.01E-04 23 Low Alarm DPDT 2 0.78 9.88E-05 22.5 SPDT 2 0.80 7.68E-05 17.5 Dual High Alarm DPDT 2 0.72 1.89E-04 43 SPDT 2 0.74 1.45E-04 33 Low Alarm DPDT 2 0.75 1.65E-04 37.5 SPDT 2 0.79 1.21E-04 27.5 Single High Alarm DPDT 2 0.73 1.10E-04 25 SPDT 2 0.75 8.78E-05 20 Low Alarm DPDT 2 0.79 8.56E-05 19.5 SPDT 2 0.82 6.37E-05 14.5 Dual High Alarm DPDT 2 0.74 1.62E-04 37 SPDT 2 0.77 1.19E-04 27 Low Alarm DPDT 2 0.78 1.38E-04 31.5 SPDT 2 0.82 9.44E-05 21.5 Single High Alarm DPDT 2 0.73 1.23E-04 28 SPDT 2 0.74 1.01E-04 23 Low Alarm DPDT 2 0.78 9.88E-05 22.5 SPDT 2 0.81 7.68E-05 17.5

Float Operated Top Insertion Tank Mounted Series 301, 303, 304 Dry- Single High Alarm DPDT 2 0.62 1.23E-04 28 SPDT 2 0.63 1.01E-04 23 Low Alarm DPDT 2 0.70 9.88E-05 22.5 SPDT 2 0.72 7.68E-05 17.5 Dual High Alarm DPDT 2 0.66 1.89E-04 43 SPDT 2 0.68 1.45E-04 33 Low Alarm DPDT 2 0.70 1.65E-04 37.5 SPDT 2 0.73 1.21E-04 27.5 Single High Alarm DPDT 2 0.62 1.10E-04 25 SPDT 2 0.63 8.78E-05 20 Low Alarm DPDT 2 0.70 8.56E-05 19.5 SPDT 2 0.73 6.37E-05 14.5 Dual High Alarm DPDT 2 0.68 1.62E-04 37 SPDT 2 0.71 1.19E-04 27 Low Alarm DPDT 2 0.73 1.38E-04 31.5 SPDT 2 0.77 9.44E-05 21.5 Single High Alarm DPDT 2 0.63 1.23E-04 28 SPDT 2 0.64 1.01E-04 23 Low Alarm DPDT 2 0.70 9.88E-05 22.5 SPDT 2 0.73 7.68E-05 17.5

Float Operated Horizontal Insertion Tank Mounted Series 401, 402, 403, 404, 405, 406 Dry- Single High Alarm DPDT 2 0.61 1.32E-04 30 SPDT 2 0.61 1.10E-04 25 Low Alarm DPDT 2 0.68 1.08E-04 24.5 SPDT 2 0.70 8.56E-05 19.5 High Alarm DPDT 2 0.60 1.19E-04 27 SPDT 2 0.61 9.66E-05 22 Low Alarm DPDT 2 0.68 9.44E-05 21.5 SPDT 2 0.71 7.24E-05 16.5 High Alarm DPDT 2 0.62 1.32E-04 30 SPDT 2 0.62 1.10E-04 25 Low Alarm DPDT 2 0.69 1.08E-04 24.5 SPDT 2 0.70 8.56E-05 19.5

Float Operated Tamperproof & Flanged Serviceable Horizontal Chamber Series 108, 208 Dry- Single High Alarm DPDT 2 0.71 1.32E-04 30 SPDT 2 0.72 1.10E-04 25 Low Alarm DPDT 2 0.76 1.08E-04 24.5 SPDT 2 0.78 8.56E-05 19.5 High Alarm DPDT 2 0.71 1.19E-04 27 SPDT 2 0.73 9.66E-05 22 Low Alarm DPDT 2 0.77 9.44E-05 21.5 SPDT 2 0.80 7.24E-05 16.5 High Alarm DPDT 2 0.71 1.32E-04 30 SPDT 2 0.73 1.10E-04 25 Low Alarm DPDT 2 0.76 1.08E-04 24.5 SPDT 2 0.79 8.56E-05 19.5

Vane Operated Vertically Mounted Series 901, 902, 903, 904 Dry- Single High Alarm/ Low Alarm DPDT 2 0.72 7.46E-05 17 SPDT 2 0.75 5.27E-05 12 High Alarm/ Low Alarm DPDT 2 0.76 6.15E-05 14 SPDT 2 0.80 3.96E-05 9 High Alarm/ Low Alarm DPDT 2 0.73 7.46E-05 17 SPDT 2 0.76 5.27E-05 12

1510 Electric Horizontal Series 1510 Reed Sw High Alarm SPST 1 0.34 9.21E-06 2.1 SPDT 1 0.36 1.00E-05 2.287 Low Alarm SPST 2 0.66 4.83E-06 1.1 SPDT 2 0.64 5.65E-06 1.287 1550 Electric Vertical Series 1550 Reed Sw High Alarm SPST 1 0.34 9.21E-06 2.1 SPDT 1 0.36 1.00E-05 2.287 Low Alarm SPST 2 0.66 4.83E-06 1.1 SPDT 2 0.64 5.65E-06 1.287

1710 Electric Horizontal Explosionproof Series Chamber/ Non- Chamber 1710 Std. Dry No Chamber High & Low Alarm DPDT 2 0.66 7.90E-05 18 SPDT 2 0.64 5.71E-05 13 Chamber DPDT 2 0.77 7.90E-05 18 No Chamber SPDT 2 0.79 5.71E-05 13 DPDT 2 0.63 7.90E-05 18 SPDT 2 0.65 5.70E-05 13 Chamber DPDT 2 0.76 7.90E-05 18 SPDT 2 0.79 5.70E-05 13 2210 Electric Horizontal Series Chamber/ Non- Chamber 2210 Std. Dry No Chamber High & Low Alarm DPDT 2 0.63 7.90E-05 18 SPDT 2 0.65 5.71E-05 13 Chamber DPDT 2 0.76 7.90E-05 18 SPDT 2 0.79 5.71E-05 13

1520 Electric Flow Series 1520 Reed Sw High Alarm SPST 1 0.5 4.83E-06 1.1 SPDT 1 0.5 5.65E-06 1.287 Low Alarm SPST 1 0.5 4.83E-06 1.1 SPDT 1 0.5 5.65E-06 1.287