SHIMADEN DIGITAL INDICATORS

Similar documents
Temperature Controllers

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

02/11/2015

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

SR70 (SR ) Series Digital controller Instruction Manual

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

02/11/2015

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

General Specifications

Series Temperature Controller Instruction Sheet

UDC 700 Universal Digital Controllers and Indicator Specifications

MICROJET RECORDER (180mm)

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

F4 Process Controller Installation and Operation Guide

UDC100 Universal Digital Controller Specifications

Instruction manual for DIN rail mounting type indicating controller DCL-33A

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MICROJET RECORDER (24-CHANNEL 180mm)

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Installation Manual Tracker 221

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

/8 DIN Level Indicator

Nov 08 PRODUCT SPECIFICATION SHEET

INSTRUCTION MANUAL Micro-computer based digital indicating controller

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Instruction manual Temperature Controller KT7

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

MICRO CONTROLLER S Z SERIES

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

GCS-300 No.GCS31E

Low Temperature Zirconia Oxygen Analyzer

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Instruction manual Micro-computer based digital indicating controller

E5CN/E5CN-U (48 x 48 mm)

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Temperature Controller

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

DIGITAL INDICATOR JIR-301-M

MICROJET RECORDER (180mm)

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

MODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

I/A Series 716C 1/16 DIN Temperature Controller

General Specifications

+ A B V B NO NC V COM PV PV

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Advanced Test Equipment Rentals ATEC (2832)

TEMPERATURE CONTROLLER

CN4800 Series CONTROLLER

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

Digital Heater Element Burnout Detector K8AC-H

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Operating Instructions tico Temperature Indicator

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

AE500 Instruction Manual

Series Digital Controller Instruction Sheet

DIGITAL INDICATOR DI25

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

MODEL: 47NLDYT. [2] OPTIONS blank: none /Q: With options (specify the specification) Digital Panel Meters 47NL Series

Process Alarm Module RTA 421

Model 1062 Environment Monitor

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Model 96VTR ¼ DIN Process Controller

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

4TEMPERATURE CONTROLLER

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

MICRO CONTROLLER H Z SERIES

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

eed quality electronic design USER s MANUAL

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

Digital Temperature Controller E5AZ

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

MICRO CONTROLLER E Z SERIES

M5800 Pressure Transducer with Rotatable Display

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

Transcription:

Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable Inputs (Thermocouples) User-Selectable Ranges Programmable Scaling (DC mv, DC ma) Power Supply (1~24V AC or 24V AC or 24V DC) Versatile Alarm Configurations Sensor Power Supply Available Interface RS-485, RS-422A or RS-232C Analog Output Scaling Available

NAME & FUNCTI Hold (HOLD) lamp Min (MIN) value lamp Max (MAX) value lamp Communication () lamp Alarm 1 (AL1) lamp Alarm 2 (AL2) lamp Range () lamp screen (DISP) key Communication () key Alarm () key Up ( ) key Shift ( > ) key Setting (SET) key Range () key > FLOW CHART DISPLAY BLOCK Screen Maximum Value Minimum Value Parameter setting block MUNICATI BLOCK ALARM BLOCK RANGE BLOCK Input mv / ma / V Communication system Alarm 1 setting Value Decimal point position Communication address *3 Alarm 1 Hysteresis s L side Data bit length Alarm 1 selections s H side Communication speed Latching release Sensor compensation Alarm 2 setting Value *2 Analogs L side *3 Alarm 2 Hysteresis *2 Analogs H side Alarm 2 type selections Latching release The shadowed area is only for equipment with optional functions. s: scaling *2 Analogs: Analog Output scaling *3 Alarm hysteresis: Alarm sensitivity

SPECIFICATIS Range : 7-segment LED (4-digit) s: Measuring range, max., min., hold Accuracy: ±.25%+1 digit of measuring range Cycle Range:.25 sec. or 2 sec. (by internal switch) Legend Change: C or F (by internal switch) Monitor : Max., min., hold, communication, alarm and range Setting Setting Method: By front key Setting Keys:, Communication, Alarm, Range, Setting, Shift and Up Type of Setting: Position of decimal point, display scaling, sensor compensation, analog output scaling, alarm, alarm sensitivity, latching, communications (interface), etc. Input Sampling Cycle:.25 sec. Thermocouples: T, J, E, K, R, S, B, WRe5-26, {U, L (DIN 4371)} Kelvin Legend: 7.~4.k (available only T / C K, option) Input Resistance: 5kΩ min. External Resistance Allowable Range: 1Ω max. Sensor Compensation: ±99.9 or ±999 Unit (depending on communication signal) Burnout Scaling: Up-scale (standard feature) R.T.D.: JPt1 / Pt1 (DIN / JIS) changeable Rated Amperage: Approx..5mA Lead Wire Resistance: 5Ω max. per wire Sensor Compensation: ±99.9 or ±9.99 Unit (depending on communication signal) Voltage: ~1mV, ~5mV or ~1mV DC changeable ~1V, ~5V, ~1V DC changeable Input Resistance: 5kΩ min Current: 4~2mA or ~2mA DC changeable Receiving Resistance: 25Ω Scaling: Only voltage and current inputs available (-1999~+9999, 1~1 counts) Setting Method & Decimal Point Position: By front key Isolation: Between input, system and various outputs Optional Functions Alarm Alarm Points: 2 Point Alarm Method: Individual setting / individual output Type of Alarm Alarm 1: Absolute value high limit or absolute value low limit (selectable) Alarm 2: Absolute value high limit, absolute value low limit, deviation high limit, deviation low limit or deviation high / low limit (selectable) Deviation high limit, deviation low limit and deviation high / low limit alarm can be selected deviation for alarm 1. Alarm Mode 1. Absolute value high limit alarm 2. Absolute value low limit alarm ( or ) 3. Deviation high limit alarm ( or ) :Alarm 1 Setting Point :Alarm 2 Setting Point 4. Deviation low limit alarm 5. Deviation high/low limit alarm

Alarm Setting: Alarm 1 Alarm 2 Alarm Setting (Mode 1, 2, 3, 4) -1999~9999-1999~9999 Alarm Setting (Mode 5) 1~9999 Alarm Sensitivity:.2~9.9 or 2~99 by front key Alarm Output: 1c contact, 25V AC, 2.5A / Resistive load Inhibit / Non-Inhibit: Selectable by internal switch Latching Alarm: Available as option Analog Output Output: ~1mV DC (output resistance: 1Ω) ~1V DC (load current: 2mA max) 4~2mA DC (load resistance: 3Ω max.) Output Accuracy: ±.25%FS of display value Resolution: Approx..1%FS Isolation: Isolated between analog output, system and various outputs Output Scaling: By front key Interface Type of Interface: RS-232C, RS-422A or RS-485 Speed: 12, 24, 48 or 96 bps selectable Data Bit: 7-bit odd-parity or 8-bit non parity Address: ~31 Code: ASCII Code Isolation: Isolated between communication signal, system and various inputs and outputs Sensor Power Supply Output Rating: 24V DC (±3V) 5mA Others Data Storage: By non-volatile memory Operating Ambient Temperature / Humidity Range: -1~5 C / 9% RH max. (no dew condensation) Applicable Standard: Safety: IEC11-1 and EN611-1 EMC: EN61326 During EMC testing, the apparatus continues to operate at a measurement accuracy within ±1% of the range Power Supply: Power Consumption: Insulation Resistance: Dielectric Strength: External Dimensions: Weight: 1~24V AC 5/6Hz, 24V AC or 24V DC 1~24V AC: 14 VA max. 24V AC: 8 VA max. 24V DC: 5W max. 5V DC 2MΩ between input terminal and earth terminal 5V DC 2MΩ between power supply terminal and earth terminal One minute at 1V AC between input terminal and earth terminal One minute at 15V AC between power supply terminal and earth terminal 48 (H) x 96 (W) x 11 (D) mm Approx. 3g Latching Alarm Latching Alarm Standard alarm Latching alarm Decrease Latching Alarm set point Sensitivity Increase Measured value Latching release by key. Latching possible

ORDERING INFORMATI ITEMS CODE SPECIFICATIS SERIES SD2-48 96 DIN Size Digital Indicator 1 Thermocouple T, J, E, K, S, R, B, WRe5-26, U, L (DIN 4371) multiple input 2 R.T.D. JPt1 / Pt1 (IEC) multiple range INPUT 3 Voltage (mv) ~1, ~5, ~1mV DC 4 Current (ma) 4~2, ~2mA DC 6 Voltage (V) ~1, ~5, ~1V DC 8 Kelvin scale (only K thermocouple) Measuring range 7.~4.K 9-1~24V AC±1% 5 / 6Hz POWER SUPPLY 2-24V DC ±1% 1-24V AC ±1% (5 / 6Hz) None ALARM 1 Individual setting, individual output 2 points (1c contact) Contact capacity: 25V AC 2.5A / resistive load 11 Ditto with latching function None 3 ~1mV DC Output resistance: 1Ω 4 4~2mA DC Load resistance: 3Ω max. ANALOG OUTPUT OR INTERFACE 6 ~1V DC Max. load current: 2mA max. 15 RS-485 16 RS-422A 17 RS-232C SENSOR DC POWER SUPPLY - None (WHEN USING HUMIDITY SENSOR OR UNGROUNDED SENSOR) 24-24V DC 5mA (capable of driving two sensors H71 / TH71) J In Japanese FRT PANEL INFORMATI E In English Without (for CE Marking) REMARKS 9 With (for remarks other than CE Marking) When 24V AC or 24V DC is selected, sensor DC power supply can not be selected. Multiple input programmable range Scaling range -1999~9999 Range of counts for scaling 1~1 Scaling possible (within measuring range) Note: Sensor DC power supply can not be selected. STANDARD RANGE & USER-PROGRAMMABLE SCALING Since the has been designed for user-selectable inputs, user-selectable ranges and user-programmable scaling, the unit will be shipped with one factory-set standard range. If a range selection other than the standard is required, user-selectable inputs (T / C s) and user-selectable ranges (T / C s & RTD) are available as listed below at the specific application. Standard Range (Factory-set When shipped) Input Standard / Rating Ranges Thermocouple JIS (K) -1.~8. C R.T.D Pt1-DIN -199.9~6. C DC Voltage ~1mV.~1. No Legend DC Current 4~2mV.~1. No Legend DC Voltage ~1V.~1. No Legend CODING EXAMPLES Example 1) SD2-19-13-E Thermocouple input Example 2) SD2-39-13-E mv input (~1mV input)

MAX MIN HOLD AL1 AL2 ENT DISP SET SD2 MEASURING RANGE CODES & LEGEND CODES INPUT RANGE Type CODE C CODE F CODE 1 B 1B ~18 A47 32 ~ 3272 A65 R 1R ~17 A46 32 ~ 392 A64 S 1S ~17 A46 32 ~ 392 A64 K 1K -2 ~12 A74-328 ~ 2192 A79-1. ~ 8. A27-148 ~ 1472 A72 E 1E. ~ 7. A9 32 ~ 1292 A63 J 1J -1. ~ 6. A26-148 ~ 1112 A71 T 1T -199.9 ~ 2. A3-328 ~ 392 A77 WRe5 / 26 1W ~23 A49 32 ~ 4172 A66 U 1U -199.9 ~ 2. A3-328 ~ 392 A77 L 1L. ~ 6. A8 32 ~ 1112 A62 2 K 1K 7. ~ 4. A67 R.T.D JPt1-199.9 ~ 6. A31-328 ~ 1112 A78 2J (JIS). ~ 99.99 A2 32. ~ 212. A61 Pt1-199.9 ~ 6. A31-328 ~ 1112 A78 2F (JIS / IEC). ~ 99.99 A2 32. ~ 212. A61 ~1mV 32 mv ~5mV 34 ~1mV 36 ma ~2mA 41 Scaling Range: -1999~9999 4~2mA 42 Span : 1~1 count ~1V 62 V ~5V 64 ~1V 66 Note 1) Thermocouple (B): Accuracy guarantee not applicable temperature below 4 C or 75 F *2 Thermocouple (K): 7.~4.K (Kelvin Legend Only) Thermocouple LEGEND CODE LEGEND CODE No legend I / min 3 C 1 I / h 31 F 2 m 3 / min 32 %RH 3 m 3 / h 33 % 4 Nm 3 / min 34 K 5 Nm 3 / h 35 mv 6 mm / s 36 V 7 m / s 37 ma 8 m / min 38 A 9 m / h 39 W 1 m / s 2 4 µs / cm 11 rpm 41 mbar 12 mm 42 bar 13 cm 43 psi 14 m 44 psig 15 mm 3 45 Pa 16 cm 3 46 kpa 17 m 3 47 mmh2o 18 in 48 mh2o 19 lb 49 inh2o 2 g 5 mmhg 21 kg 51 cmhg 22 t 52 inhg 23 l 53 l / s 24 ppm 54 kg / h 25 ph 55 kg / cm 2 26 cal 56 kgf / cm 2 27 kcal 57 Torr 28 Blank 58 mmaq 29 Blank 59 Codes 58 and 59 are for customers to fill out. EXTERNAL DIMENSIS & TERMINAL ARRANGEMENT External Dimensions 11 96 1 1 92 +.8 Panel Cutout 48 44.6 x 91.6 45 +.6 Terminal Arrangement 92 +.8 24V DC 12W 24VAC 5/6Hz12VA + - 11 12 GR 1to24VAC ALARM1 ALARM2 5/6Hz1VA 2.5A24VAC 2.5A24VAC 11 12 13 14 15 16 17 18 19 2 22 21 HOLD NO1 NC1 NO2 NC2 C1 C2 BCD OUTPUT 1 2 3 4 5 6 7 8 9 24 23 1 A B B RESET + - TERMINAL SPECIFICATI 1 21 22 23 24 A-OUTPUT - + RS-232C SG SD RD RS-422A SG SD- SD+ RD- RD+ RS-485 SG - + DC OUTPUT (24V DC 5mA) - + A-output (Analog output) 45 +.6 more than 11mm (Unit : mm) more than 7mm ISO 91 (The contents of this brochure are subject to change without notice.) Temperature and Humidity Control Specialists Head Office: 2-3-1 Kitamachi, Nerima-Ku, Tokyo 179-81 Japan Phone: +81-3-3931-7891 Fax: +81-3-3931-389 E-MAIL: exp-dept@shimaden.co.jp URL: http://www.shimaden.co.jp ESD2 13