Waterless Engine Coolants. General Installation Instructions

Similar documents
Evans Waterless Engine Coolant. General Installation Instructions.

INSTALLATION PROCEDURE 2011 Navistar MaxxForce 13L

INSTALLATION PROCEDURE 2011 Navistar MaxxForce 13L

INSTALLATION PROCEDURE Detroit Diesel DD15/DD13

INSTALLATION PROCEDURE FOR VOLVO D-SERIES HEAVY DUTY ENGINES

INSTALLATION PROCEDURE MACK E7

Modern Auto Tech Study Guide Chapters 39 & 40 Pages Cooling Systems 43 Points. Automotive Service

Engine Cooling Pulsator

Heaters and Defrosters

Tanis Engine Dehydrator. User s Guide

Service Bulletin

SECTION 1D ENGINE COOLING

K&W Permanent Metallic Block Seal

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Read this entire manual before operation begins.

Cleaning the internal optics surfaces

SPECIFICATIONS PART NAME

SELF-CONTAINED CRESCENT CUBER

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

OPERATION & MAINTENANCE MANUAL TC670

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Do not open the cooling system while it is hot or while the engine is running.

BMW E36 Thermostat Removal And Coolant Flush

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

PrimePour TM Operation Manual

Hoshizaki America, Inc.

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Climate Control System

Subject: Air Conditioning Odor (Install Evaporator Core Dryer Kit and Apply Cooling Coil Coating)

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

SERVICE PROCEDURES. SERVICE TYPE: JPMC Winterization ACCESS: See Order Instructions for Lockbox Code SCHEDULING PROCEDURES: ON-SITE PROCEDURES:

REFRIGERANT LEAK DETECTOR

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

CALIBRATION KIT #

What is Included with a Seasonal Service?

User information. Cleaning/descaling and sanitizing

OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

IN ORDER TO PERFORM THESE TASKS, YOU WILL NEED THREE THINGS:

Hoshizaki America, Inc.

Hoshizaki America, Inc.

US Filtermaxx. 200,000 BTU Waste Oil Burner

PORTABLE DOG BATH TOOL

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

SELF-CONTAINED FLAKER

TABLE OF CONTENTS FOR YOUR SAFETY

AUC Cell Washer. User Manual

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

- 1 - Updated on 18 March, 2010

02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65

GOLF TECHNICAL BULLETIN

Radiator Coolant Flush

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

OPERATION & MAINTENANCE MANUAL TX600

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

HOME INSPECTOR EDUCATION EXPO 2016


Operating Manual for. Ultrawash Plus. Absorbance. Plate Washing. Luminescence. Automated Processing. Software

Portable Air-conditioner

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

1998 Expedition/Navigator Workshop Manual

For routine maintenance of polished granite installations with a cleaner and protector:

Thermo-Bob 4 Installation Manual KT5A Kit

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)


RiteTemp. Evaporative Cooler. Information Brochure (internal) RiteTemp. RiteTemp. Date: 03/30/05. Cool-Air 5051

INSTALLATION & OPERATION MANUAL

FRYMASTER TCF. Chicken Fryer

Cast Iron Commercial Hot Water Or Steam Boiler

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Hoshizaki America, Inc.

FLOW METER KIT #

MLT100 Mirror Waterfall Fountain Bronze

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Thank you for buying this refrigerator-freezer. To ensure that you get the best

Garment Steamer Model SC620

VFCB. Ice Frost 2 and 3 Bowl Post-Mix and 2 Bowl Pre-Mix. Installation, Service, and Operator s Manual

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

SCIF SOP for BSL 2 samples on Aria3

USER'S INFORMATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

Portable Air-conditioner Use and Care Manual

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Chef Base Refrigerators

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

Refrigerant changeover guidelines

I N S T R U C T I O N S

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

Transcription:

Waterless Engine Coolants General Installation Instructions

General Installation Instructions 19Jan2015 Due to the variety of equipment and cooling system configurations, only generic installation procedures are provided in this document. All V6 and V8 engines require special attention to the draining of the block. Specific information is available for some vehicles and engines at www.evanscooling.com. Thoroughly review these instructions before starting your installation of Evans Waterless Coolant (EWC). Also, at the beginning of the installation process, have on hand enough supplies of the appropriate EWC (Heavy Duty, High Performance, Powersports, or Arctic) and Evans Prep Fluid to complete the project. See your owner s manual for cooling system capacity. When converting an engine from a water-based coolant to EWC, great care should be given during the installation (conversion) process to insure that all of the old water-based coolant is removed before installing new EWC. When the conversion is complete, the water content of the fluid should be no more than 3% to take best advantage of the waterless coolant technology. SPECIAL CONSIDERATIONS 1. WATER CONTENT: As stated previously, the water content of EWC after installation should not exceed 3%. The existing water-based coolant must be completely drained from the system. It is recommended that Evans Prep Fluid be used to absorb and remove residual water and coolant after draining the system. Water should NOT be used to flush the system after draining the coolant. The sole exception is if the system requires chemical cleaning prior to coolant changeover. See next section. 2. COOLING SYSTEM CLEANERS: New EWC should not be installed into a dirty system. If the system or the drained used coolant shows signs of contamination (oily film, rust or sediment, etc.), a chemical flush should be performed. Follow the cleaner product instructions closely. The system must be thoroughly flushed with water after using the cleaner. Keep in mind that flushing with water makes residue that is 100% water. (Residual 50/50 coolant is only half water.) 3. SCA s/coolant FILTERS: Evans waterless coolants are not intended to be used in conjunction with supplemental coolant additives (SCA) or extenders. Chemical filters used in heavy duty applications should be replaced with non-chemical filters prior to installation of EWC. No additions of any kind should be made to the system with the exception of topping off the system with new waterless coolant. If compromised by addition of other coolants or fluids, including water, a coolant replacement should be performed. Because EWC tends to remove old cooling system deposits which are then trapped by the filter, the filter on higher mileage vehicles should be inspected monthly and changed as needed until they appear essentially clean. 2

SPECIAL EQUIPMENT 1. A high-volume air source (rather than high pressure) If compressed air is used to help remove the old coolant and water, be aware that it can damage cooling system components. The use of high volume, low pressure air is preferred because it is safer, and in most cases, more effective. Recommended air sources include the Makita UB1103 variable speed hand-held blower and the various on-off blowers by Metro Vacuum. A shop doing commercial installations should consider the Metro Vacuum MB 3CD Air Force Master Blaster. 2. Brix scale hand held refractometer or water test strips Testing the water content of the installed EWC requires the use of one of the methods shown in Appendix 1. Note that the Brix Refractometers used to measure water content are not the same as those used to determine freeze point. SPECIAL PRECAUTIONS WARNING: NEVER WORK ON OR REMOVE THE PRESSURE CAP FROM A HOT PRESSURIZED COOLING SYSTEM. ALLOW TO COOL COMPLETELY BEFORE STARTING COOLANT CONVERSION. HANDLING, STORAGE, AND DISPOSAL CONSIDERATIONS As with water-based coolants, EWC and Prep Fluid should be considered toxic. Used coolant and Prep Fluid should be collected and disposed of in accordance with federal, state, and local environmental regulations. EWC should be tightly capped for storage and kept away from children and pets. EWC and Prep Fluid are hygroscopic (can absorb water from the air), which is another reason to avoid leaving partially-used containers open. INSTALLATION PROCEDURE 1. Drain the System: Remove the pressure cap (SEE WARNINGS ABOVE). Open all drain valves and plugs. Open bleeder or petcock vents if there are any. Drain all parts of the system, including radiator, coolant reservoir, engine block, and heater. Draining the system only from the bottom of the radiator removes less than half of the system capacity. Note: Ancillary systems in heavy duty applications that may contain coolant include APU s, fuel tank heaters, and DEF tank heaters. These sub-systems need to be drained as well. Use high-volume/low pressure air to gently blow out various parts of the system. If accessible, blow out heater circuit, blowing only in the direction from the hot coolant source (generally, the cylinder head) toward the coolant return (generally, the inlet to the coolant pump). Ensure that the heater control valve is open before applying the air. Block drains are frequently inaccessible, ineffective, or non-existent, and considerable amounts of coolant can remain in the block. Removal of the thermostat provides an opening to the engine where high volume air can be blown through the head and block, pushing old coolant past the coolant pump and out the bottom radiator hose or radiator drain. For V6 and V8 engines with inaccessible block drains or no block drains, refer to www.evanscooling.com for special procedures to achieve a proper conversion. 3

Engines having an inlet side thermostat and a good block drain (e.g., DD15) do not require removal of the thermostat. With the block drain open, air blown toward the engine through the top radiator hose will purge the residual coolant in the block. Completely empty the overflow bottle if the vehicle is equipped with one. If the system has a pressurized expansion tank, blow air into it to make sure it is empty. 2. Purge the System: Close all drain valves, plugs, and vents, and reconnect circuits. If the engine is equipped with a coolant filter (heavy duty systems), replace the filter with one that does not introduce coolant additives. Fill the system with Prep Fluid to flush parts of the cooling system suspected of harboring residual coolant or water. DO NOT use water. Vent as needed to ensure complete fill. Replace the pressure cap and run the engine with the heater on, at full hot, for 10 minutes after reaching operating temperature (thermostat open). Repeat the sequence given in step 1 to drain out the used Prep Fluid. 3. Refill the System: Close all drain valves, plugs and vents, and reconnect all circuits. Fill system completely with the appropriate EWC, and start engine. Add coolant as needed to keep system full. If system is equipped with a vented overflow bottle, leave it empty for now. Replace the pressure cap and run engine with the heater on, at full hot, for 10 minutes after reaching operating temperature (thermostat open). Shut the engine off and allow the system to cool. 4. Test the Coolant: Draw a sample of well-circulated coolant from the radiator or pressurized overflow reservoir. Check the water content using a refractometer or test strips as outlined in Appendix 1. The coolant being tested must be at room temperature before testing. Caution minimize exposure of the coolant to air during testing. If the above procedure has been rigorously followed, the water content of the coolant should be within specification (below 3 percent). If the water content exceeds 3%, run the system again to operating temperature, and allow sufficient time for the thermostat to open and fluid to circulate through the radiator. Repeat sampling and water content test. If the water content still exceeds the limit, see remediation procedure under Test Strips in Appendix 1. If the water content is 3% or less, the equipment is ready for use. Ensure the overflow bottle or expansion tank is filled to the cold mark with EWC. Place Evans warning stickers in strategic locations (radiator cap, radiator shroud, overflow bottle, expansion tank) to warn against adding water or water-based coolant to the system. Upon cool-down and for a few days thereafter, small amounts of coolant addition may be necessary. Whether the system has a pressurized expansion tank or an overflow bottle, the coolant level should be at the cold line when the engine is cold. 4

MIXING COOLANTS Waterless and water-based coolants should not be mixed. In the event that significant waterless coolant is lost from the system during operation and no waterless coolant is available to fill the system and reach a repair facility, water-based coolant or water may be used. However, repairs should be made as soon as possible, and the system should be drained, purged and re-filled with new waterless coolant. STOP LEAK USE Leaks should be repaired. Stop-leak type products are not intended to be permanent repairs. However, they may be used as a temporary measure. Carefully follow the instructions on the stop leak product label. Overuse may clog radiator and heater core passageways. 5

APPENDIX 1 DETERMINING WATER CONTENT OF A WATERLESS COOLANT BRIX HAND-HELD ANALOG REFRACTOMETER USE INSTRUCTIONS Evans Part No. E2190 General Considerations Readings are temperature sensitive, so calibration must be performed before each session. Before every reading, wipe the glass with a paper towel. Use a glass or metal rod to transfer coolant specimen. Wipe it off between measurements. Conduct measurements immediately. Ambient humidity can affect measurements. Repeat measurements until readings are consistent. Directions Calibrate the Refractometer: a. Wipe the glass and daylight plate clean with paper towel. b. Place 2-3 drops of virgin Evans Waterless Coolant on the refractometer glass. c. Aim refractometer toward bright light and adjust focus. d. Use the small screwdriver supplied with the instrument and set the reading to 55.7. Take the Reading: a. Wipe the glass and daylight plate clean with paper towel. b. Place 2-3 drops of coolant, obtained from a location in the cooling system where the coolant is wellcirculated, onto the glass and close the daylight plate. c. Measure the water content with the refractometer. The reading must be 54.4 or higher to confirm the water content is 3 percent or less (a required condition). ⁰Brix % Water 55.7 0.0 55.0 1.0 54.7 2.0 54.4 3.0 54.0 4.0 53.5 5.0 53.0 6.0 52.5 7.0 6

WATERLESS COOLANT TEST STRIPS INSTRUCTIONS Evans Water Content Test Strips are available: Bottled in bulk as shown (Evans P/N E2197BTS) As part of the Evans Conversion Test Kit (P/N E2197) Follow test instructions carefully to ensure accurate results. 1. Using a clean container, draw a coolant sample that is approximately 30 ml (1 fl. oz.) from a wellcirculated location. Cover container and allow sample to cool to below 100 F (37.8 C). 2. Remove a test strip from its plastic bag or bottle. Reseal. DO NOT touch color pad at end of strip. Strip must be used within 15 seconds after removing it from its container. 3. Dip strip into the coolant sample and gently move it back and forth for 20 seconds. 4. Remove strip from the sample and briskly shake it to remove excess liquid. Lay the strip on a flat, nonporous surface. 5. Wait 2 minutes and 20 seconds, then immediately compare strip s pad to the color chart below. Note: Color key provided here is only as information. Use the key found on the test strip bottle label or instruction card in the conversion kit. Water Content 0% 3% 5% >5% Water Content Correction Procedures 0 to 3% Water: Good Conversion no adjustment needed 3 to 5% Water: ADJUSTMENT NEEDED 1. Drain half of the system contents and dispose of properly. 2. Re-fill system following directions in step 3 of Installation Procedure section. 3. Re-run water test following steps 1-5 above. >5% Water: RE DO CONVERSION 1. Re-check water content to confirm first measurement; 2. If still >5%, re-do conversion, closely following steps 1-4 of Installation Procedure section. 3. Re-run water test following steps 1-5 above. 7

For detailed installation instructions or further assistance, go to www.evanscooling.com Or, scan the QR code below. Evans Cooling Systems, Inc. 1 Mountain Road Suffield, CT 06078 1-888-990-2665 2015 Evans Cooling Systems, Inc. E2197-Instructions 8