Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Similar documents
Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

PURGE/PRESSURIZATION SYSTEM

MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS

Isco 3700ZR Sampler. Manual Set

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

Installation Instructions Type XPMC Air Heater for Hazardous Locations

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

C1N & C2N SERIES Fluid heating for light industrial applications

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Certificate of Compliance

SYSTEMS PRODUCT OVERVIEW

HL SERIES Fluid heating for commercial applications

MODEL CX -WAC/HP AIR CONDITIONERS & HEAT PUMPS

Nitrogen Generation Systems Compressed Air Dryers

CLE SERIES Fluid heating for emergency eyewash stations

Field Certification Certificate of Compliance

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

custom cabinets and junction boxes

Analog Room Pressure Monitor RPC Series

Ar-Mite TM Low Flow Armored Flowmeter

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Centro-Matic Automated Lubrication Systems System Controls

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Certificate of Compliance

Fire Alarm System Accessories

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Brasch Hazardous Location Unit Heaters

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

When reliability is vital. Alemite Carbon Shield TM Systems deliver

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Technical Specification VFD

Cabinet Cooler Systems

FX5 Series Explosion-Proof Electric Air Heaters

Fire Alarm System Accessories

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Performance Data. curus Component Recognized; File No. E IP 20

your dust explosion protection experts

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Alternative Fuel Fueling Stations

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

FM-200 In-Cabinet Series

RQE Series Temperature Controllers

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Certificate of Compliance

CL & CLG Clamp Mount Mixers

Process Protection. MFA 4P Motion Failure Alarm

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Vibratone Horns. Models 350 and 450

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

WFDE Series Waterflow Detector

CLEANROOM MONITOR CR3A Network - Installation Instructions

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

The Signal Is Clear TM

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR ELECTRIC TANKLESS WATER HEATERS SPECADVANTAGE SAFE ADVANTAGE

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

MODELS 304GC, 304GCX, 314GC, and 314GCX

Twin-Agent Fire Fighting/Securing Systems Specifications

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

Certificate of Compliance

Applications and Features

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

ELECTRICAL SAFETY Information Bulletin

Electronic Pressure Digest. Pressure and Temperature Transmitters

OG5000 Ozone Generator Model OG5000B-A. User Manual

Model D12-IR. Digital Gas Transmitter...

Installation Instructions for W2H Series Signals

Circulation Heaters Selection Guidelines

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Safety Instrumented Fire & Gas Systems

Static Pressure Alarm For Hazardous Location Fume Hoods

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR ELECTRIC TANKLESS WATER HEATERS

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

Transcription:

Type Y & Z purge and pressurization system 1004 Features Assembly NFPA 70, NFPA 496, ISA 12.4 standards Optional alarm output indicates air lock failure Type Y system certified for Class I, Division 1 to Division 2 Type Z system certified for Class I, Division 2 to nonhazardous Enclosure volume up to 200 ft 3 Function Model 1004 is a Rapid Exchange purging system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed (protected) enclosure(s), in order to remove and prevent flammable gas or vapor accumulations. The system accomplishes four air exchanges and maintains a "safe" (0.25") pressure. A Pepperl+Fuchs Model EPV-4 Enclosure Protection Vent is required for proper operation. This process reduces the hazardous (classified) area rating within the enclosure(s), in accordance with the NEC - NFPA 70, Article 500, NFPA 496 and ISA 12.4. Connection Alarm system Power source WPS Terminal block connections COM NO Alarm switching Alarm Normally Closed Alarm Normally Open Alarm Common (+) ( ) Wiring configuration Wiring configuration Pressure switch NO Local alarm horn or beacon COM NO Alarm system Power source 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) WPSA Terminal block connections 120 VAC Neutral 120 VAC Hot Alarm Switching Alarm Normally Closed Alarm Normally Open Alarm Common (+) ( ) 120 VAC power supply (supply voltages 24 VDC and 240 VAC available on request) NO Pressure switch Local alarm horn or beacon 1

General specifications Series 1004 Hazardous environment gas Electrical specifications Connection Terminal blocks Output Output I -WPS- Output type Switch contacts Contact loading 120 VAC @ 15 A Output II -WPSA- Output type Switch contacts Contact loading 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 ma power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts Pneumatic parameters Protective gas supply Instrument grade air or inert gas Pressure requirement 80-120 psi Safe pressure Setpoint: 0.25" (6.35 mm) Flow rate: 0.1-3.5 SCFH (2.8-99 l /hr) Operating conditions Process conditions Capacity and filtration 8.5 oz @ 40 µ Exchange pressure 3" - 5" Exchange flow rate 30 SCFM / 1800 SCFH (With regulator set to 80 psi min during exchange) Exchange time 1 min / 7.5 ft 3 Ambient conditions Ambient temperature -29... 49 C (-20.2... 120.2 F) Mechanical specifications Connection type System supply port: 1/2" FPT Enclosure supply fitting: 1/2" tube fitting Enclosure reference fitting: 1/4" tube Switch conduit port size: 1/2" FPT Material Filter regulator body: zinc w/enamel finish Regulator handle & bowl: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Rapid Exchange gauge: poly case and brass tube Tube fittings & valves: 316 ss forged body Tubing: 316 ss 1/4" & 1/2".035 welded System nameplate: silk screened Lexan & ss Fastener hardware: alum. & stainless steel Mounting plate: 316 14 ga #3 brush ss EXP pressure switch body: anodized cast aluminum Enclosure warning nameplate: silk screened stainless steel Mass 1004-LPS-* 6.8 kg (15 lb) 1004-WPS* 10.4 kg (23 lb) International approvals FM approval Type Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class I, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D UL approval culus Type Z LPS: Class I, Division 2, Groups A, B, C, D WPS: Class I, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D Type Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class I, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D WPS: Class I, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D 2

Assembly Supply Inlet Fitting SC-8 or -8 1/2" Supply Tubing 1/4" Tubing Reference Enclosure Supply Fiting EBC-8 EPV-4-SA... Enclosure Protection Vent System Mounting Kit SMK-2 Enclosure Reference Fitting EFC-4 Warning Nameplate EWN-1 Dimensions Overall system dimensions LPS / WPS LH - left hand RH - right hand TM - top mount Height 12 / 16.25 12 / 16.25 12 / 12 Width 13.5 / 16.75 Depth LPS / WPS Height Width Depth BM - bottom mount WM - wall mount FM & PM - surface 12 / 12 13.5 / 16.75 12 / 15 7.75 / 9.25 Dimensions in inches. Mounting dimensions available upon request. FM & PM panel cutout dimensions: LPS - 13 h x 14.5 w WPS - 17.25 h x 14.5 w. Height & Width dimensions reflect mounting plate measurements. Depth dimension reflects overall measurement of system, including components. 14 / 18.25 15.5 / 15.5 3

System Accessories Connection fittings -8 1/2" ninety connector SC-8 1/2" straight connector EFC-4 1/4" flush connector EFC-8 1/2" flush connector EBC-8 1/2" bulkhead connector EPC-14 1-1/2" pipe connector Additional items SMK-2 Surface Mounting Kit (-LH-, -RH-, -TM-, -BM-, -WM- models SMK-8 Surface Mounting Kit (-FM-, -PM- models) EPSK-1 Explosion Proof Switch Kit (Class I areas) EPSK-1A Explosion Proof Switch Kit (Class I areas) GPSK-1 General-purpose Switch Kit (Class I areas) RAH Remote Alarm Horn RAB-1 Div. 1 Remote Alarm Beacon RAB-2 Div. 2 Remote Alarm Beacon LCK "L" style conduit fitting kit TCK "T" style conduit fitting kit Warning nameplates EWN-1 Class I enclosure warning ETW Enclosure temperature warning Installation & Operation Manual DOCT-1357 Installation and Operation Manual 4

Type code/model number 1 0 0 4 - L P S - C I - Y Z - L H - V X - 2 4 V D C *Voltage 24 VDC 240 VAC 120 VAC Cooler indicator gauge VX vortex Mounting configuration LH vertical mount left RH vertical mount right TM horizontal mount top BM horizontal mount bottom WM wall mount FM frame mount PM panel mount (LPS style only) System type YZ Div 1 to Div 2; Div 2 to nonhazardous Area classification Cl Class I area System style LPS WPS WPSA less pressure switch with pressure switch with pressure switch (120 VAC standard) 1004 series model number * only for WPSA option 5