LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

Similar documents
LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch (from firmware version 1.7)

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

WRF04 CO 2 RS485 Modbus

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat

Color Touch Heating Thermostat WARMTEC WTS

Instruction FH-CWP Thermostat

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

ECL Comfort 110, application 116

Control solutions Biofloor

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

ET10 Series Stand-alone LCD Fan Coil Thermostat

ELECTRONIC COMMUNICATING THERMOSTAT

INSTALLATION & USER MANUAL

User instructions DHP-AT

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

Varenummer: Version:

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Digital Electronic Thermostat With RF

Touch Screen Thermostats. Features. Accuracy +/-1 C. Power supply 220 Vac. Consumption < 1.5 W. Timing error < 1% Ordering TST 8A TST 8B TST 8C

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Digital Electronic Thermostat With RF

Modulating clock thermostat

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Model: Edge-HC. 1 edge-hc

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Weather compensated flow temperature control of heating and boiler systems

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

Model: Available in: Sapphire Black and Glacier White. 1 Series

Installer Manual KNX Touchscreen Thermostat

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

Installation Guide. ECL Comfort 210, application A Table of Contents

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

User Guide UTI-IQCP. Control panel for setting and monitoring of UTI-INV internal temperature regulator. v EN

Installation and user manual

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

REMOTE CONTROL FOR CHILLER MYCHILLER

Digital Room Thermostat

Model: RT310. Installation Manual

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

User s guide. Multiple programming Electronic thermostat

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Semi flush-mount room thermostats

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

OPERATION MANUAL. Packaged air-cooled water chillers and packaged reversible air to water heatpumps EWAQ009ACV3 EWAQ010ACV3 EWAQ011ACV3

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

ETN1000/MIGA - Operating manual

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A

ECL Comfort 110, application 130

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Model: Available in : Sapphire Black and Glacier White. 1 Series

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Touch Screen Room Thermostat with Modbus Communication

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

ETAF Series VDC Fan output LCD Fan Coil Thermostat

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Installation Instructions. devireg 700/ /752/753/754

Connect the power supply and equipment to supply to the controller is displayed for the

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

T-32-TS Touchscreen Thermostat. Installation Manual

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

L. Terminal block Connecting Label:

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

EXPERT TRI-STAR. Temperature controller. User s Manual

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

ETN-24-SUPER-SF Series

installation guide digital timer thermostat

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Technical description. Atec.

Operating Manual UV Monitor UVT 18

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Operating Functions Temperature Parameters


RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Transcription:

LCF Touch Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room thermostat, used for individual control of temperature in commercial, industrial and residential buildings. It is tailored for two-pipe and four-pipe fan coil units with two-wire electric valves. The device combines digital technology with a large LCD touch screen display, which enables the single room controller to be used intuitively. Integrated 7 day time clock with 4 time programs. Security Advice Caution The installation and assembly of electrical equipment must be performed by a skilled electrician. The modules must not be used in any relation with equipment that threatens, directly or indirectly, human health or life or with applications that can result in danger for people, animals or assets. Before connecting devices with electrical power supply the installation must be isolated from the power source! Notes on Disposal The product is considered electrical and electronic waste and must be disposed accordingly. Special treatment for specific components may be legally binding or ecologically sensible. The local and current applicable legislation must be followed. Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Seite 2 / 8 Stand: 3.11.214 Electrical Connection The devices are powered by mains voltage (normally between 9 and 265 V). Please follow the technical data instructions on how to correctly power each device. With regards to passive sensors with 2-wire conductor versions, the wire resistance of the supply wire has to be considered. If necessary the wire resistance should be compensated by the heat gain from the electronics. Due to self-heating, the wire current affects the measurement accuracy. So it should not exceed 1 ma. The ambient temperature of the transducer electronics should be kept constant. The transducers must be operated at a constant supply voltage (±,2 V). When turning the supply voltage on/off, onsite power surges must be avoided. When using lengthy wiring (depending on the cross section used) the supply may be compromised due to a voltage drop at the common GND-wire (caused by the voltage current and the line resistance). In this case, 2 GND-wires must be wired to the sensor - one for supply voltage and one for the measuring current. Remarks to Room Sensors Location and Accuracy of Room Sensors The room sensor should be mounted in a suitable location for measuring accurate room temperature. The accuracy of the temperature measurement also depends directly on the temperature dynamics of the wall. It is important, that the back plate is completely flush to the wall so that the circulation of air occurs through the vents in the cover. Otherwise, deviations in temperature measurement will occur due to uncontrolled air circulation. Also the temperature sensor should not be covered by furniture or similar devices. Mounting next to doors (due to draught) or windows (due to colder outside wall) should be avoided. The temperature dynamics of the wall will influence the temperature measurement. Various wall types (brick, concrete, dividing and hollow brickwork) all have different behaviours with regards to thermal variations. Surface and Flush Mounting The temperature dynamics of the wall influence the measurement result of the sensor. Various wall types (brick, concrete, dividing and hollow brickwork) have different behaviours with regard to thermal variations. A solid concrete wall responds to thermal fluctuations within a room in a much slower way than a light-weight structure wall. Room temperature sensors installed in flush boxes have a longer response time to thermal variations. In extreme cases they detect the radiant heat of the wall even if the air temperature in the room is lower for example. The quicker the dynamics of the wall (temperature acceptance of the wall) or the longer the selected inquiry interval of the temperature sensor, the smaller the deviations limited in time are. Technical Data Power supply: 9..265 V ~ 5/6 HZ Power consumption: <,9 W Temperature sensor: NTC 1 K Set point adjustment: +1..+5 C (default +16..+3 C) Accuracy: ±1 C Display: LCD touch screen Material: ABS, scratch-resistant acrylic Output: Heating/cooling: Relay 25 V ~ / 3 V =, 5 A Fan stage: Relay 25 V ~ / 3 V =, 5 A Cable entry: from the rear Clamps: Terminal screw max 1,5 mm² Protection: IP2 according to EN 6529 Working condition: -1..5 C, 5..95% rf non cond. Storage temperature: -25..65 C Dimensions (LxWxD): 86x86x15,5 mm Weight: 16 g Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Stand: 3.11.214 Seite 3 / 8 Display Terminal Connection Plan LCF Touch Standard Auto mode wiring diagram for 2-pipe fan coil: ATTENTION: 9..265 V LCF Touch Standard Manual mode wiring diagram for 2-pipe fan coil: LCF Touch Standard wiring diagram for 4-pipe fan coil: Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Seite 4 / 8 Stand: 3.11.214 Installation For installing or repairing, please make sure the power for the thermostat has been turned off. Insert the screw driver in the plastic teeth of the thermostat. Turn the screwdriver clockwise and the front cover and base plate will be separated. Please follow the wiring diagram to connect the wires. Fix the thermostat base plate to the wall by using the four screw holes with a distance between the axes of 6mm. Fasten base plate and front cover. Do not press the panel in order to protect LCD. Commissioning Operation in 2-pipe system (parameter No. 13 set to 2): When using an external sensor, the thermostat can detect whether the fluid is convenient for cooling or for heating: Operation without external sensor: In the 2-pipe system, a fluid can be used only for cooling or only for heating depending on the temperature of the fluid. When no external sensor is used, heating, cooling and ventilating mode have to be selected manually using MODE settings (depending on the desired action of the heating/cooling system). Operation with an external sensor: By using an external sensor, the system recognizes, whether the fluid has the necessary temperature for cooling or for heating. The heating or cooling control sequence will be automatically selected. When temperature is +19 C, cooling mode is activated; when the temperature is +3 C, the heating mode is active. MODE key has no function in this case. Operation in 4-pipe system (parameter No. 13 set to 4): The thermostat switches automatically between cooling and heating. A time delay between cooling/heating mode changes is implemented to ensure safe and eco-friendly operation. Parameter No.14 has to be set to 1 to enable the device for operating in auto mode. Mode selection: Manual Mode: 2-pipe-System: Cooling Ventilating Heating 4-pipe-System: Cooling Ventilating Heating Auto mode (only when parameter No. 14 is set to 1!) AUTO Mode: Fan Coil system selection: The cooling or heating sequence will be automatically detected. Setting parameter No. 13, the selection of the fan coil system has to be done. 2-pipe or 4-pipe systems can be selected. Fan Stage selection: In Cooling, Heating or Auto mode, following fan stages can be selected: In Ventilation mode, following fan stages can be selected: Ventilation mode can be deactivated by setting parameter No. 15 to. Display C or F: Low Med Hi Auto Low Med Hi Display of the units C or F can be selected using parameter No. 12. Fahrenheit temperature display range is 32..99 F, C temperature display range is..5 C. Factory default is C. Note: Under Parameter No.1 the temperature offset can be adjusted. This feature should be used if the temperature at the mounting place of the Room Thermostat is not accurate to the average room temperature. Temperature Room Temperature set point selection: By pressing or button, the room temperature set point can be adjusted. C Range is 16..3 C, Fahrenheit temperature range is 6..86 F. By using Parameter No. 4 and No. 5, the set point ranges can be adjusted. Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Stand: 3.11.214 Seite 5 / 8 Fan stage/valve control selection: Under Fan operation INDEPENDENT, the fan will always operate according to the selected or automatically assigned fan stage; under Fan operation DEPENDENT, the fan will be tuned off in case the valve is closed. If the valve is open, the fan will operate according to the selected or automatically assigned fan stage. By using parameter No. 16, the INDEPENDENT or DEPENDENT mode can be selected. Key lock selection (No. 2), power failure selection (No. 3), screen save mode (No. 6) can be set by Parameters. Also in parameter No. 7 you are able to read the LCD display status. Sensor failure alarm: If the temperature sensor is out of range, the thermostat will switch off the fan and close the valve, error code E1 will be shown. Language selection You can change the display language with parameter No. 11. Set time format With parameter No. 8 the time format to 12h or 24h can be defined. Time setting Press the button, to set the time. The changing parameter is blinking, press or -button to set: Order: Week hour minute Timer on Timer off week hour Set timer Press the -button, the parameter to be changed is flashing, the timer will be set on or off. Finish: Timer on, LCD display ; Finish: Timer off, LCD display ; To delete timer on/off, press the button, the parameter to be changed is flashing. Then select or, set the time like the following image to leave the timer mode:. The system saves the user settings to set the timer on / off automatically. Selection timer on / off The timer on/off has 2 options to be selected: single action or rule. To set, please look up parameter No. 9 in the parameter table. 7 days 4 periods programmable timer One day is split into 4 periods. The user can set temperature for every period individually. To set the time zones, please look up parameter No. 1 in the parameter table. If the user has set a set temperature during operation, the current period runs with the last set temperature. The next period will adopt the changed settings. Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Seite 6 / 8 Stand: 3.11.214 Please follow the instructions below: Press the button for more than 5 seconds, the parameter to be changed is flashing. Now you can set the 4 programmable periods. hour minute temperature 1 hour minute temperature 2 hour minute temperature 3 hour minute temperature 4 Parameters: = MODE button In order to change the parameters, please press the MODE button for more than 5 seconds. Please follow figure below. If you are asked to enter the password, use or key to enter each digit of the password. Press MODE button to switch to the next digit. The standard password is 26. If the password has been entered correctly, you will see the parameter settings screen as below shown: Press the MODE button to select the parameter you would like to change. Then use or to change the parameter. Please refer to the parameter table on the following page 7: Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Stand: 3.11.214 Seite 7 / 8 No. Name of parameter Parameter definition Factory default 1 Temperature offset: Range -2..+2 K 2 Key-lock: - unlocked 1- lock on / off 2- lock mode 3- lock clock 4- lock fan speed 5- lock temperature setting 6- lock all keystrokes 3 Power failure: - stay power off 1- restore last status before power failure 2- turn power on after power failure 4 Upper temperature limit: Range: +1..+5 C / +34..99 F 3 C / 86 F 5 Lower temperature limit: Range: +1..+5 C / +34..99 F 16 C / 6 F 6 LCD backlight delay: 1..15 seconds 2 seconds 7 Screensaver mode: - display on / off 1- room temperature and on / off 2- display clock, room temperature and on / off 3- display all status 8 Time format: 12-12 hours 12 24-24 hours 9 Timer on / off: - once 1- loop 1 7 days, 4 periods - forbidden programmable: 1- allowed 11 Display language: 1- English 1 12 Temperature format: - C 1- F 13 Selection Fan Coil: 2-2-pipe Fan Coil 2 4-4-pipe Fan Coil 14 Auto cooling & heating - deactivated modus: 1- activated 15 Fan modus: - deactivated 1 1- activated 16 Selection fan on / off: - independent 1- dependent 17 Temporarily not defined All parameters are stored within an EEPROM (electrically erasable programmable ROM), ensuring no data loss if the Thermostat is powered off. Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de

Seite 8 / 8 Stand: 3.11.214 Dimensions (mm) Display unit: Base plate: Optional Accessories Screws Ø3x18 WA 2 pieces Thermokon Sensortechnik GmbH, Platanenweg 1, 35756 Mittenaar, Germany tel: +49 2778 696- fax: -4 www.thermokon.de email@thermokon.de