Application Engineering

Similar documents
AE R20 January Cooling Requirements for Copelametic and Copeland Discus Compressors

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant changeover guidelines

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Application Engineering

Application Guidelines for ZS**KAE Refrigeration Copeland Scroll Compressors HP

Application Engineering

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421

AE R8 March 2015

AE R21 September 2017

AE R17 November 2016

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors

AE R13 August 2018 Economized Vapor Injection (EVI) for ZF*KVE and ZF*K5E Compressors TABLE OF CONTENTS

MACH N-407 Heat Pump Air-Cooled Chiller

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

Application Guidelines for ZB*KC/ZB*KCE Copeland Scroll Refrigeration Compressors 7 to 15 HP

MAC N-407 Air-Cooled Chiller

INDEXING AND CLASSIFICATION SYSTEM

Application Engineering

Center Mount Unit Coolers

MAC-120HE-03 Air-Cooled Chiller

AE R9. AE R9 May Application Guidelines For K4 Refrigeration Copeland Scroll Compressors Horsepower

Refrigeration System Report March 2017

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Technical Information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

Low Profile Unit Coolers

Low Profile Unit Coolers

Application Guidelines for Low Temperature ZF**KAE 1-2.5HP Copeland Scroll Refrigeration Compressors

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

CHALLENGER 1 COOLING UNITS

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

These units are available now from the Distribution Center. For a list of available models, click here.

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Kramersaver Air Cooled Condensing Units

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Application Engineering

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

LOW PROFILE UNIT COOLER

Warm Case Troubleshooting Guide 9/18/2014

Application Guidelines

LOW PROFILE UNIT COOLER

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Air-Cooled Condensing Units with Compact Screw Compressors

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Installation & Operation Manual

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Chapter 9. Refrigeration and Liquefaction

Installation & Operation Manual

Slim Contour Unit Cooler

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

horizontal air discharge outdoor discus condensing unit

REFRIGERANT CHANGEOVER

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

INSTALLATION and OPERATION INSTRUCTIONS

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

Application Guidelines. Scroll Compressors for Air Conditioning ZR18K* to ZR380K*, ZP24K* to ZP485K*

Spare parts catalogue

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Tranquility Digital Quick Start Guide

Installation Instructions

For more Parts Information:

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

Scroll Compressors for Heat Pump Applications ZH12K4E to ZH11M4E, ZH06KVE to ZH48KVE

NEWGATE TECHNOLOGIES, INC.

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Super-Flo Low Profile Unit Cooler

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

INSTALLATION AND OPERATION MANUAL

AIR COOLED PACKAGED CHILLER

Filtered Containment Venting System. Proven Technology Passive Operation

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Bosch BVA Series Air Handler

Sound Performance Rating of Outdoor Unitary Equipment

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

Digital. Application Guidelines Digital Scroll Compressors for Refrigeration ZBD21K* to ZBD114K* ZFD13KVE to ZFD25KVE ZFD41K5E

intarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Chilled Water system

Sound Performance Rating of Non-ducted Indoor Airconditioning

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Transcription:

Application Engineering May 2010 Cooling Requirements for Copelametic and Copeland Discus Compressors Introduction In response to customer inquires, both domestic and international, Emerson Climate Technologies has reviewed our application requirements for oil coolers and head fans applied on Copeland Discus compressors in the R-404A/R-507 low temperature applications. Product engineering has done extensive testing of various parameters, including unloading as well as fully loaded. The results were the basis for the application envelope shown in Figure 1. The latest testing has shown that as long as the suction return gas is maintained below 65 F, Discus compressors can be operated down to -25 F evaporating on R-404A/R-507 without the requirement of a head fan or oil coolers. Additionally, head fans can be eliminated at even lower evaporating temperatures if return gas temperatures can be maintained at the lower values. Emerson Climate Technologies application engineering will approve these applications upon receipt of acceptable test data. NOTE: If you remove the oil cooler, you must install the by-pass loop to maintain proper oil fl ow. The cooling requirements for all other Copelametic motor-compressors and refrigerants are clearly defined below. Any deviation from these recommendations can result in failure of the compressor. Air-Cooled Compressors As the name implies, air-cooled compressors are totally dependent on heat transfer to the air to maintain proper temperatures. Air-cooled compressors require constant airfl ow across the compressor for proper cooling. Merely drawing air through a compartment over the compressor is not adequate - direct impingement on the compressor from the fan discharge is necessary. If compressor cooling is provided by the condenser fan, fan cycling for head pressure control is not acceptable unless auxiliary cooling is provided. Water-Cooled Compressors Some smaller Copelametic compressors are wrapped with water coils for application on water-cooled condensing units. If water is circulated through the coil wrapped around the compressor, adequate cooling will be provided. Refrigerant-Cooled Compressors (Non Discus) Refrigerant suction cooled compressors are adequately cooled by the refrigerant at evaporating temperatures above 0 F. If operated at evaporating temperatures below 0 F, auxiliary cooling is required. At evaporating temperatures below 0 F, the compressor can be cooled adequately by the condenser fan discharge. Fan cycling for head pressure control is not acceptable unless auxiliary cooling is provided. Fan cycling for head pressure control for medium and high temperature applications is acceptable. Vertical cooling fans are recommended for compressors 3 H.P. in size and larger when auxiliary cooling is required. A standard fan assembly developing 1000 CFM airfl ow is available, with interchangeable brackets to fi t different model compressors. Compressors designed for an oil cooler, (6RL, 6RT, 4RL) must be applied with an oil cooler and a vertical cooling fan. Two Stage Compressors All two stage compressors are provided with an interstage expansion valve, and adequate cooling is provided by the refrigerant. No auxiliary fan is required. If the compressor is mounted in the fan discharge stream on a condensing unit, adequate cooling will be provided. When applied with a remote condenser, an auxiliary fan is required. 1

Part Number For Compressor Model Table 1 Vertical Fan Assemblies (To be mounted on top of compressor) Description 998-0550-00 All Fan assembly including 230-1-60/50 motor, fan blade, guard. 998-0550-01 All Fan assembly including 440/380-1-60/50 motor, fan blade, guard. 998-0550-02 All Fan assembly including 115-1-60/50 motor, fan blade, guard. 998-0574-00 L 998-0574-01 M 998-0574-02 N 998-0574-03 4D-4R 998-0574-04 6D-6R 998-0574-05 6DL/T-6RL/T 998-0574-06 9R Old Style Head 998-0574-08 9D-9R New Style Head* 3D 998-0574-11 2D 998-0574-10 *3D Moduload/Discus Digital 998-0574-07 6DL/T-6RL/T Mounting Kit and oil cooler assembly. 998-1123-00 6DL/T-6RL/T Oil cooling assembly, including oil cooler, studs, spacers, and fi ttings. 998-1124-00 4DL/T-4RL/T Oil cooling assembly, including oil cooler, studs, spacers, and fi ttings. * Use 998-0574-08 for 3D models without unloading. Use 998-0574-10 for 3D models with Moduload or Discus Digital unloading Table 2 Vertical Cooling Fan Space Requirement Compressor Model Add to Compressor Height, Inches L 8.0 N 8.0 M 8.5 9 8.5 4 9.5 6 10.25 2

Compressor HP Minimum Air Flow (cfm) Table 3 Horizontal Fan Assemblies (To blow on compressor side) Fan and Motor Assembly Part Number Electrical Fan Space Requirement Additional Height to Compressor (in.) Additional Width to Compressor (in.) 1 650 998-0050-00 230V-1Ø-60/50 Hz 1.25 5.50 1 1/2 650 998-0050-00 230V-1Ø-60/50 Hz 1.25 5.50 2 650 998-0050-02 230V-1Ø-60/50 Hz None 5.50 998-0050-03 460V-1Ø-60/50 Hz None 5.50 140 Figure 1 Discus Head Fan Requirements R-404A, R-507 Evaporating Temperature ( C) -45.5-42.8-40.0-37.3-34.5-31.8-29.0-26.3-23.5-20.8-18.0-15.3-12.5 59.4 130 53.9 120 48.4 Condensing Temperature ( F) 110 100 90 80 70 Head Fan Required Except by A.E. Approval No Head Fan & No Oil Cooler Required ( 65F Max R.G.) 42.9 37.4 31.9 26.4 20.9 Condensing Temperature ( C) 60 15.4 50 9.9 40 4.4 30-1.1 20-6.6-50 -45-40 -35-30 -25-20 -15-10 -5 0 5 10 Evaporating Temperature ( F) 3

Discus Head Fan and Oil Cooler Requirements With Low Temperature R-407A and R-407C Copeland Discus compressors are also approved for use with R-407A and R-407C in low temperature applications. Latest testing by Emerson Climate Technologies engineering has shown that as long as the compressor is equipped with Copeland Demand Cooling, a Copeland Discus compressor using R-407A or R-407C in low temperature applications does not require a head fan or an oil cooler. Table 4 lists the low temperature compressor model numbers which Emerson has released without the oil cooler attached. Table 4 Nomenclature Scheme to Identify Copeland Discus Compressor Models s Existing Model w/oil Cooler New Model (Standard) New Model 1-Bank Unloader New Model 2-Bank Unloader 4DA3F47Kx-TSK/TSE SAME 4DN3F47Kx-TSK/TSE 4DE3F47Kx-TSK/TSE --- 4DL3F63Kx-TSK/FSD/TSE 4DH3F63Kx-TSK/FSD/TSE 4DP3F63Kx-TSK/FSD/TSE 4DK3F63Kx-TSK/FSD/TSE --- 4DT3F76Kx-TSK/FSD/TSE 4DJ3F76Kx-TSK/FSD/TSE 4DS3F76Kx-TSK/FSD/TSE 4DR3F76Kx-TSK/FSD/TSE --- 6DL3F93Kx-TSK/FSD/TSE 6DH3F93Kx-TSK/FSD/TSE 6DC3F93Kx-TSK/FSD/TSE 6DK3F93Kx-TSK/FSD/TSE 6DD3F93Kx-TSK/FSD/TSE 6DP3F93Kx-TSK/FSD/TSE 6DT3F11Mx-TSK/FSD/TSE/ESX 6DJ3F11Mx-TSK/FSD/TSE/ESX 6DE3F11Mx-TSK/FSD/TSE 6DR3F11Mx-TSK/FSD/TSE 6DF3F11Mx-TSK/FSD/TSE 6DS3F11Mx-TSK/FSD/TSE 4

ADDENDUM The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Emerson Climate Technologies, Inc. and/or its affi liates (collectively "Emerson"), as applicable, reserve the right to modify the design or specifi cations of such products at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson product remains solely with the purchaser or end user. CAUTION POE must be handled carefully and the proper protective equipment (gloves, eye protection, etc.) must be used when handling POE lubricant. POE must not come into contact with any surface or material that might be harmed by POE, including without limitation, certain polymers (e.g. PVC/CPVC and polycarbonate). 2012 Emerson Climate Technologies, Inc.