G21/GSR21 SERIES UNITS LENNOXOEMPARTS.COM

Similar documents
G32V. Service Literature G32V SERIES UNITS

GHR32Q/V SERIES UNITS

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

Corp L12 Revised G24M SERIES UNITS

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

MERIT SERIES Downflow

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

8+* Bulletin No November 1997

ELITE SERIES Downflow - High Efficiency Blower Motor

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

F8AUH Gas Furnaces Up-Flow/Horizontal

GSR21Q PULSE21 SERIES

GHR26. Service Literature GHR26 SERIES UNITS DOWN FLOW POSITION HORIZONTAL POSITION

INSTALLATION INSTRUCTIONS

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

MERIT SERIES Downflow

INSTALLATION INSTRUCTION

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

Corp L8 Revised G23(X) SERIES UNITS LENNOXOEMPARTS.COM

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

G34M Bulletin #69/ August 2003

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

LZP-2 ZONE CONTROL PANEL

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

B SERIES ELECTRIC FURNACE

Service Literature GCS/CHA16 15 and 20 Ton (52.8 and 70.3 kw)

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Operator: Save these instructions for future use!

Service Literature GCS/CHA16 6, 7.5, 10 and 12.5 Ton (21, 26.4, 35.2 and 44.0 kw)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

INSTALLATION INSTRUCTIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

INSTALLATION INSTRUCTIONS

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

50A Integrated Furnace Control

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

TECHNICAL SPECIFICATIONS

Operator: Save these instructions for future use!

RGE 13 A T - 1 A

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

13 GEP A L P - 1 A

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

FG7T (C and L Series)

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

PELLET STOVE SERVICE MANUAL

Operator: Save these instructions for future use!

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

Multi-Position Gas Furnaces

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Transcription:

Service Literature G2 and GSR2 units are condensing furnaces utilizing the pulse combustion process. Initially, combustion takes place in an enclosed chamber. Then, as combus tion products pass through the heat exchanger system into a coil, the latent heat of combustion is extracted and water is condensed from the exhaust gas. The unit uses a redundant gas valve to assure safety shut off as required by A.G.A. The units are manufac tured for natural gas application. L.P. kits for A.G.A. / C.G.A. units are available for field changeover. An electronic direct spark ignition control initiates com bustion. The ignition control serves four functions: pre purge, ignition, flame sensing and post purge. Controls reset in the event of nuisance lockout. The control also verifies loss of combustion during a cycle, closing the gas valve. A differential pressure switch shuts down the unit immediately if there are obstructions in the exhaust outlet or air intake. A purge blower clears the combustion chamber before and af ter each heating cycle to ensure proper air mixture for start up. All units feature direct drive multi speed blower motors. V" series units feature an electronically controlled blower motor (ICM or ICM2) controlled by a VSP control (VSP or VSP2 ). The VSP controls blower CFM using either a G2/GSR2 SERIES UNITS G2/GSR2 Corp. 985 L9 Revised 0 200 PWM (pulse width modulation) signal or fixed 24 VAC or VDC signal. These signals are gener ated by optional controls such as the Harmony zone control system, Efficiency Plus Humidity Control (CCB) or a thermostat. A PWM signal is generated by the Harmony zone control system. A fixed DC signal is generated by the Efficiency Plus Humidity Control (CCB) and a 24 VAC signal is generated by a thermo stat. ELECTRONICALLY CONTROLLED MOTOR ICM ICM2 The Harmony zone control system produces a PWM signal to regulate blower CFM. The CCB varies indoor blower speed in response to indoor humidity demand. The CCB produces a DC signal. When a two speed condensing unit is used with the Harmony zone control system or CCB, compressor speed as well as indoor blower CFM are controlled more accurately than with a conventional two stage thermostat. All specifications in this manual are subject to change. PULSE COMBUSTION PROCESS 7 EXHAUST Gas and air enter and mix in combustion chamber 4 2 To start the cycle a spark is used to ignite the gas and air mixture (this is one "pulse"). 3 Positive pressure from combustion closes BACK PRESSURE IGNITION flapper valves and forces exhaust gases down 5 TAILPIPE the tailpipe. 4 Exhaust gases leaving chamber create a negative pressure. This opens the flapper valve COMBUSTION drawing in gas and air. CHAMBER 5 At the same instant, part of the pulse is reflected back from the tailpipe causing the COMBUSTION 3 new gas and air mixture to ignite. No spark is needed. (this is another pulse"). 6 Steps 4 and 5 repeat 60 to 70 times per second forming consecutive pulses" of /4 to /2 4 2 Btuh each. AIR 7 Latent heat is removed from combustion OPEN CLOSED SENSOR 3 products and condensate (water) is formed in SPARK the condensate coil. GAS Page 998 Lennox Industries Inc. Litho U.S.A.

General Page Parts Arrangement Page 3 Specifications Blower Data TABLE OF CONTENTS Page 4 6 Page 6 0 Component Illustration Page I Application Page 2 II Unit Components VSP Blower Control VSP2 Blower Control Ignition Control Page 2 36 Page 5 6 Page 7 9 Page 2 24 Blower Motor Q Units Page 29 ICM and ICM2 III Installation IV Maintenance V Unit Checkout VI Troubleshooting Page 30 36 Page 36 44 Page 45 46 Page 46 53 Page 54 56 VII Troubleshooting Charts Page 57 68 GC Ignition Control Page 57 GC3 Ignition Control Page 58 G89 Ignition Control Page 58 Electrical Checkout Page 59 Gas, Air, Spark Check Page 60 Electrical Testing Page 6 ICM2 VSP2 Page 62 ICM VSP Page 63 65 Additional Charts Page 66 68 VIII Wiring and Sequence of Operation G2Q Page 69 70 GSR2Q Page 7 72 G2V Page 73 74 GSR2V Page 75 76 G2Q W/ GC3 Page 77 78 G2Q W/ GC Page 79 80 GSR2Q W/ GC3 Page 8 82 GSR2Q W/ GC Page 83 84 G2V W/ GC Page 85 86 G2V W/ GC3 Page 87 88 GSR2V W/ GC Page 89 90 GSR2V W/ GC3 Page 9 92 Page 93 99 Jumper Summary Tables ELECTROSTATIC DISCHARGE (ESD) Precautions and Procedures CAUTION Electrostatic discharge can affect electronic com ponents. Take precautions during furnace installa tion and service to protect the furnace s electronic controls. Precautions will help to avoid control ex posure to electrostatic discharge by putting the furnace, the control and the technician at the same electrostatic potential. Neutralize electrostatic charge by touching hand and all tools on an un painted unit surface, such as the gas valve or blow er deck, before performing any service procedure. Page 2

DIFFERENTIAL PRESSURE SWITCH LIMIT CONTROL PARTS ARRANGEMENT (G2 UPFLOW UNIT) HEAT EXCHANGER ASSEMBLY GAS VALVE IGNITION CONTROL AIR INTAKE CONNECTION EXPANSION TANK GAS FLAPPER VALVE & ORIFICE ASSEMBLY ICM BLOWER MOTOR AIR VALVE AND AIR HOUSING LOW VOLTAGE TERMINAL STRIP CONTROL BOX BLOWER G2Q SERIES BLOWER MOTOR DOOR INTERLOCK SWITCH PARTS ARRANGEMENT (GSR2 DOWNFLOW HORIZONTAL UNIT) IGNITION CONTROL AIR INTAKE PVC CONNECTION ICM2 BLOWER MOTOR AVAILABLE ELECTRONICALLY CONTROLLED BLOWER MOTOR V" MODELS BLOWER COMPARTMENT LOW VOLTAGE TERMINAL STRIP DOOR INTERLOCK SAFETY SWITCH HEAT EXCHANGER ASSEMBLY AIR FLAPPER AND HOUSING CONTROL BOX EXHAUST OUTLET GAS VALVE PURGE BLOWER EXPANSION TANK Page 3

SPECIFICATIONS (units equipped with conventional multi speed blower motor) Model No. G2Q3 40 G2Q3 60 G2Q4 60 Input Btuh 40,000 60,000 60,000 Output Btuh 38,000 55,000 55,000 *A.F.U.E. 96.2% 94.% 94.% California Seasonal Efficiency 90.7% 89.9% 88.8% Temperature rise range ( F) 35 65 40 70 35 65 High static certified by A.G.A. (in wg.).50.50.50 Gas Piping Size Natural /2 /2 /2 I.P.S. (in.) **LPG /2 /2 /2 Vent/Intake air pipe size connection (in.) 2 2 2 Condensate drain connection (in.) SDR /2 /2 /2 Blower wheel nominal diameter x width (in.) 0 x 8 0 x 8 x 9 Blower motor hp /3 /3 /2 Number and size of filters (in.) () 6 x 25 x () 6 x 25 x () 6 x 25 x Tons of cooling that can be added /2 3 /2 3 2 /2 4 Electrical characteristics 20 volts 60 hertz phase (less than 2 amps) All models **LPG kit (optional) LB 6580A LB 6580B LB 6580B External Filter Mounting Part No. LB 887CA LB 887CA LB 887CA Kit (optional) Filter size (in.) () 6 x 25 x () 6 x 25 x () 6 x 25 x Filter is not furnished with kit. Filter kit utilizes existing filter supplied with G2 unit. *Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations. Isolated combustion system rating for non weatherized furnaces. **LPG kit must be ordered extra for field changeover. SPECIFICATIONS (units equipped with conventional multi speed blower motor) Model No. G2Q3 80 G2Q4 80 G2Q5 80 G2Q3 00 G2Q4/5 00 Input Btuh 80,000 80,000 80,000 00,000 00,000 Output Btuh 73,000 73,000 74,000 93,000 95,000 *A.F.U.E. 93.9% 93.9% 93.2% 94.9% 94.5% California Seasonal Efficiency 90.% 88.9% 88.3% 90.8% 89.6% Temperature rise range ( F) 45 75 40 70 35 65 55 85 40 70 High static certified by A.G.A. (in wg.).50.50.50.50.50 Gas Piping Size Natural /2 /2 /2 /2 /2 I.P.S. (in.) **LPG /2 /2 /2 /2 /2 Vent/Intake air pipe size connection (in.) 2 2 2 2 2 Condensate drain connection (in.) SDR /2 /2 /2 /2 /2 Blower wheel nominal diameter x width (in.) 0 x 8 x 9 2 x 2 0 x 8 2 x 2 Blower motor hp /3 /2 3/4 /2 3/4 Number and size of filters (in.) () 6 x 25 x () 6 x 25 x () 20 x 25 x () 20 x 25 x () 20 x 25 x Tons of cooling that can be added 2 3 2 /2 4 4 or 5 2 3 3 /2 5 Electrical characteristics 20 volts 60 hertz phase (less than 2 amps) All models **LPG kit (optional) LB 6580B LB 6580B LB 6580B LB 6580C LB 6580C External Filter Mounting Part No. LB 887CA LB 887CA LB 887CB LB 887CB LB 887CB Kit (optional) Filter size (in.) () 6 x 25 x () 6 x 25 x () 20 x 25 x () 20 x 25 x () 20 x 25 x Filter is not furnished with kit. Filter kit utilizes existing filter supplied with G2 unit. *Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations. Isolated combustion system rating for non weatherized furnaces. **LPG kit must be ordered extra for field changeover. Page 4

SPECIFICATIONS (contd.) SPECIFICATIONS (units equipped with conventional multi speed blower motor) Model No. GSR2Q3 50 GSR2Q4 5 0 GSR2Q3 8 0 GSR2Q4/5 80 GSR2Q4/5 00 Input Btuh 50,000 50,000 80,000 80,000 00,000 Output Btuh 47,000 47,000 7,000 72,000 92,000 *A.F.U.E. 94.8% 95.3% 9.7% 94.% 92.0% California Seasonal Efficiency 89.7% 90.% 87.6% 88.6% 87.3% Temperature rise range ( F) 30 60 25 55 40 70 30 60 45 75 High static certified by A.G.A. (in wg.).50.50.50.50.50 Gas Piping Size Natural /2 /2 /2 /2 /2 I.P.S. (in.) LPG /2 /2 /2 /2 /2 Vent/Intake air pipe size connection (in.) 2 2 2 2 2 Condensate drain connection (in.) SDR /2 /2 /2 /2 /2 Blower wheel nominal diameter x width (in.) 0 x 8 0 x 0 0 x 0 2 x 2 2 x 2 Blower motor hp /3 /2 /3 3/4 3/4 Number and size of filters (in.) () 20 x 25 x Tons of cooling that can be added /2 3 3 /2 4 2 3 3 /2 5 3 /2 5 Electrical characteristics 20 volts 60 hertz phase (less than 2 amps) All models LPG kit (optional) **Furnished LB 6580C Optional Horizontal Support Frame Kit Ship. Weight LB 56495CA (All Models) 8 lbs. Optional Downflow Additive Base Shipping Weight LB 80639BB (All Models) 6 lbs. LPG kit must be ordered extra for field changeover. *Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations. Isolated combustion system rating for non weatherized furnaces. **LPG orifice furnished as standard with unit for field changeover. Convertible gas valve requires simple adjustment without adding any parts. See installation instructions. SPECIFICATIONS (units equipped with electronically controlled blower motor) Model No. G2V3 60 G2V3 80 G2V5 80 G2V5 00 Input Btuh 60,000 80,000 80,000 00,000 Output Btuh 55,000 73,000 74,000 95,000 *A.F.U.E. 94.3% 94.5% 93.4% 94.5% California Seasonal Efficiency 92.5% 92.4% 90.9% 9.5% Temperature rise range ( F) 40 70 45 75 35 65 40 70 High static certified by A.G.A. (in wg.).80.80.80.80 Gas Piping Size Natural /2 /2 /2 /2 I.P.S. (in.) **LPG /2 /2 /2 /2 Vent/Intake air pipe size connection (in.) 2 2 2 2 Condensate drain connection (in.) SDR /2 /2 /2 /2 Blower wheel nominal diameter x width (in.) 0 x 8 0 x 8 /2 x 9 /2 x 9 Blower motor hp /2 /2 Number and size of filters (in.) () 6 x 25 x () 6 x 25 x () 20 x 25 x () 20 x 25 x Tons of cooling that can be added /2, 2, 2 /2 or 3 2, 2 /2 or 3 3 /2, 4 or 5 3 /2, 4 or 5 Electrical characteristics 20V 60hertz phase 2.0 Amps Max 20V 60hertz phase 4.5 Amps Max External Filter Cabinet (furnished) Filter size (in.) () 6 x 25 x () 6 x 25 x () 20 x 25 x () 20 x 25 x **LPG kit (optional) LB 6580B LB 6580B LB 6580B LB 6580C Filter is not furnished with cabinet. Filter cabinet utilizes existing filter supplied with G2V unit. *Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations. Isolated combustion system rating for non weatherized furnaces. **LPG kit must be ordered extra for field changeover. Page 5

SPECIFICATIONS (contd.) SPECIFICATIONS (units equipped with electronically controlled blower motor) Model No. GSR2V3 80 GSR2V5 80 GSR2V5 00 Input Btuh 80,000 80,000 00,000 Output Btuh 7,000 72,000 92,000 *A.F.U.E. 94.5% 94.6% 92.0% California Seasonal Efficiency 92.5% 92.% 89.7% Temperature rise range ( F) 40 70 30 60 45 75 High static certified by A.G.A. (in wg.).80.80.80 Gas Piping Size Natural /2 /2 /2 I.P.S. (in.) LPG /2 /2 /2 Vent/Intake air pipe size connection (in.) 2 2 2 Condensate drain connection (in.) SDR /2 /2 /2 Blower wheel nominal diameter x width (in.) 0 x 8 /2 x 9 /2 x 9 Blower motor hp /2 Number and size of filters (in.) () 20 x 25 x Tons of cooling that can be added 2 3 3 /2 5 3 /2 5 Electrical characteristics 20V 60hertz phase 2.0 Amps Max 20V 60hertz phase 4.5 Amps Max LPG kit (optional) **Furnished LB 6580C Optional Horizontal Support Frame Kit Ship. Weight LB 56495CA (All Models) 8 lbs. Optional Downflow Additive Base Shipping Weight LB 80639BB (All Models) 6 lbs. LPG kit must be ordered extra for field changeover. *Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations. Isolated combustion system rating for non weatherized furnaces. **LPG orifice furnished as standard with unit for field changeover. Convertible gas valve requires simple adjustment without adding any parts. See installation instructions. BLOWER DATA (units equipped with conventional multi speed blower motor) External Static Pressure (in. wg) G2Q3 40, G2Q3 60 AND G2Q3 80 BLOWER PERFORMANCE Air Volume @ Various Speeds High Medium Low 0 585 392 920.05 558 364 97.0 533 354 95.5 505 335 92.20 477 35 905.25 447 294 893.30 48 272 887.40 355 225 858.50 282 64 803 TE All cfm data is measured external to unit with the air filter in place. External Static Pressure (in. wg) G2Q5 80 BLOWER PERFORMANCE Air Volume (cfm) @ Various Speeds High Med High Medium Med Low Low 0 2460 2350 255 900 695.05 2430 230 230 875 675.0 2395 2275 200 855 655.5 2355 2240 2065 825 625.20 235 2205 2035 800 600.25 2275 275 995 780 570.30 2235 230 960 740 540.40 255 2055 880 675 480.50 2070 970 790 605 40.60 980 890 70 540 345 TE All cfm data is measured external to unit with the air filter in place. Page 6

External Static Pressure (in. wg) BLOWER DATA (contd.) (units equipped with conventional multi speed blower motor) G2Q4 60 AND G2Q4 80 BLOWER PERFORMANCE Air Volume @ Various Speeds High Medium Low 0 793 295 050.05 770 290 050.0 747 285 050.5 724 280 050.20 700 275 050.25 675 267 050.30 648 258 050.40 585 233 036.50 57 93 02 TE All cfm data is measured external to unit with the air filter in place. G2Q3 00 BLOWER PERFORMANCE External Static Pressure (in. wg) G2Q4/5 00 BLOWER PERFORMANCE Air Volume @ Various Speeds High Medium Low 0 850 660 500.05 805 635 470.0 760 60 440.5 720 575 420.20 680 540 400.25 635 505 375.30 590 470 350.40 500 400 290.50 400 320 220.60 290 230 40 TE All cfm data is measured external to unit with the air filter in place. External Static Pressure (in. wg) Air Volume (cfm) @ Various Speeds High Med High Medium Med Low Low 0 2450 2340 240 90 690.05 2420 230 20 880 670.0 2390 2270 2080 860 640.5 2350 2240 2050 830 620.20 2320 220 2020 800 590.25 2280 270 990 770 570.30 2250 240 960 740 540.40 280 2060 890 680 480.50 200 980 80 60 420.60 2005 890 740 530 350 TE All cfm data is measured external to unit with the air filter in place. GSR2Q3 50 BLOWER PERFORMANCE GSR2Q3 80 BLOWER PERFORMANCE External Static Pressure (in. wg) Air Volume (cfm) @ Various Speeds High Med High Med Low Low 0 640 405 070 875.05 620 390 065 870.0 595 375 060 865.5 570 360 055 860.20 545 345 045 855.25 520 325 035 850.30 490 305 025 840.40 430 260 995 80.50 365 200 960 775.60 285 35 90 735.70 95 055 840.80 085 955 755 TE All cfm data is measured external to unit with the air filter in place. External Static Pressure (in. wg) Air Volume @ Various Speeds High Medium Low 0 735 455 095.05 720 445 090.0 700 435 085.5 675 420 080.20 640 405 070.25 65 385 060.30 585 355 045.40 520 290 995.50 440 20 930.60 330 20 870.70 80 05.80 035 900 TE All cfm data is measured external to unit with the air filter in place. Page 7

BLOWER DATA (contd.) (units equipped with conventional multi speed blower motor) GSR2Q4 50 BLOWER PERFORMANCE GSR2Q4/5 80 BLOWER PERFORMANCE External Static Pressure (in. wg) Air Volume (cfm) @ Various Speeds High Med High Med Low Low 0 935 725 530 225.05 900 695 55 220.0 865 665 490 20.5 825 630 465 95.20 790 595 435 75.25 745 560 400 40.30 700 520 365 05.40 585 420 285 030.50 470 320 200 975.60 360 25 5 920.70 235 5 030.80 05 000 930 External Static Pressure (in. wg) TE All cfm data is measured external to unit with the air filter in place. TE All cfm data is measured external to unit with the air filter in place. GSR2Q4/5 00 BLOWER PERFORMANCE External Static Pressure (in. wg) Air Volume (cfm) @ Various Speeds High Med High Medium Med Low Low 0 2275 240 940 725 520.05 2245 20 95 700 490.0 225 2075 885 675 465.5 285 2040 860 645 435.20 250 2005 830 620 40.25 25 970 805 590 380.30 2075 935 775 560 350.40 990 870 70 500 290.50 925 800 645 435 235.60 835 730 570 370 75.70 760 650 490 300.80 675 570 400 225 TE All cfm data is measured external to unit with the air filter in place. Air Volume (cfm) @ Various Speeds High Med High Medium Med Low Low 0 2355 2205 965 740 520.05 2325 275 940 75 495.0 2290 250 920 695 475.5 2255 25 890 670 450.20 2220 2085 860 645 425.25 285 2050 830 620 400.30 250 2020 800 595 375.40 2080 950 745 540 320.50 2000 880 680 475 260.60 95 805 65 40 95.70 825 720 540 330.80 730 635 460 240 Units Equipped With an Electronically Controlled Blower Motor ICM2 G2V3 60/80 BLOWER MOTOR PERFORMANCE (For Static Pressure 0.0" to 0.8" w.g.) ADJUST LOW SPEED HIGH (COOL) SPEED HEAT SPEED JUMPER VSP2 JUMPER POSITION VSP2 JUMPER POSITION VSP2 JUMPER POSITION SETTING 2 3 4 2 3 4 2 3 4 + 540 700 830 000 50 260 400 40 50 250 350 420 RM 490 630 740 880 040 40 240 265 030 40 220 300 440 560 670 800 940 030 40 60 920 020 00 90 TE: ADJUST position on JPB ( RM", +", or ") determines the row of CFM available to use. TE All air data is measured external to the unit with the air filter in place. Blower maintains a constant CFM throughout a range of varying static pressures. Page 8

BLOWER DATA (contd.) (units equipped with an electronically controlled blower motor ICM2) G2V5 80/00 BLOWER MOTOR PERFORMANCE (For Static Pressure 0.0" to 0.8" w.g.) ADJUST LOW SPEED HIGH (COOL) SPEED HEAT SPEED JUMPER VSP2 JUMPER POSITION VSP2 JUMPER POSITION VSP2 JUMPER POSITION SETTING 2 3 4 2 3 4 2 3 4 + 800 050 40 620 70 2030 2270* 2270* 900 240 2270* 2270* RM 720 950 280 500 570 850 200 2220 700 940 2080 2200 620 850 20 30 420 650 860 990 520 730 860 940 TE: ADJUST position on JPB ( RM", +", or ") determines the row of CFM available to use. *2300 CFM @ 0.2" w.g.; 2250 CFM @ 0.5" w.g.; 2200 CFM @ 0.8" w.g. TE All air data is measured external to the unit with the air filter in place. Blower maintains a constant CFM throughout a range of varying static pressures. GSR2V3 80 BLOWER MOTOR PERFORMANCE (For Static Pressure 0.0" to 0.8" w.g.) ADJUST LOW SPEED HIGH (COOL) SPEED HEAT SPEED JUMPER VSP2 JUMPER POSITION VSP2 JUMPER POSITION VSP2 JUMPER POSITION SETTING 2 3 4 2 3 4 2 3 4 + 520 670 800 960 0 220 340 420 0 20 30 420 RM 480 600 740 880 070 60 270 300 000 00 200 280 420 550 650 770 950 040 50 70 900 000 00 60 TE: ADJUST position on JPB ( RM", +", or ") determines the row of CFM available to use. TE All air data is measured external to the unit with the air filter in place. Blower maintains a constant CFM throughout a range of varying static pressures. GSR2V5 80/00 BLOWER MOTOR PERFORMANCE (For Static Pressure 0.0" to 0.8" w.g.) ADJUST LOW SPEED HIGH (COOL) SPEED HEAT SPEED JUMPER VSP2 JUMPER POSITION VSP2 JUMPER POSITION VSP2 JUMPER POSITION SETTING 2 3 4 2 3 4 2 3 4 + 860 00 460 740 800 2090 200* 200* 930 200* 200* 200* RM 770 020 390 580 720 990 200* 200* 800 2000 200* 200* 680 900 80 400 450 690 940 2040 580 780 920 200 TE: ADJUST position on JPB ( RM", +", or ") determines the row of CFM available to use. *2200 CFM @ 0.2" w.g.; 200 CFM @ 0.5" w.g.; 2000 CFM @ 0.8" w.g. TE All air data is measured external to the unit with the air filter in place. Blower maintains a constant CFM throughout a range of varying static pressures. Page 9

Units Equipped With an Electronically Controlled Blower Motor ICM G2V3 60, G2V3 80 BLOWER PERFORMANCE FACTORY BLOWER SPEED SETTINGS G2V3 60 G2V3 80 Low Speed Heat/Cool tap 2 Low Speed Heat/Cool tap 2 High Speed Cooling tap High Speed Cooling tap High Speed Heat tap 6 High Speed Heat tap 7 External Static Air Volume (cfm) @ Various Speeds Pressure (in. wg.) Tap Tap 2 Tap 3 Tap 4 Tap 5 Tap 6 Tap 7 Tap 8 Tap 9 Tap 0 Tap 0 thru.80 490 635 760 880 030 40 220 345 420 420 TE All air data is measured external to the unit with the air filter in place. *Blower maintains a constant CFM throughout a range of varying static pressures. G2V5 80, G2V5 00 BLOWER PERFORMANCE FACTORY BLOWER SPEED SETTINGS G2V5 80 G2V5 00 Low Speed Heat/Cool tap 2 Low Speed Heat/Cool tap 2 High Speed Cooling tap High Speed Cooling tap High Speed Heat tap 6 High Speed Heat tap 7 External Static Air Volume (cfm) @ Various Speeds Pressure (in. wg.) 0 thru.80 Tap Tap 2 Tap 3 Tap 4 Tap 5 Tap 6 Tap 7 Tap 8 Tap 9 Tap 0 Tap 770 05 305 50 685 820 200 2050 200 200 TE All air data is measured external to the unit with the air filter in place. *Blower maintains a constant CFM throughout a range of varying static pressures. External Static GSR2V3 80 BLOWER PERFORMANCE FACTORY BLOWER SPEED SETTINGS GSR2V3 80 Low Speed Heat/Cool tap 3 High Speed Cooling tap High Speed Heat tap 7 Air Volume (cfm) @ Various Speeds Pressure (in. wg.) 0 thru.80 Tap Tap 2 Tap 3 Tap 4 Tap 5 Tap 6 Tap 7 Tap 8 Tap 9 Tap 0 Tap 480 655 790 960 20 220 365 460 460 TE All air data is measured external to the unit with the air filter in place. *Blower maintains a constant CFM throughout a range of varying static pressures. External Static GSR2V5 80, GSR2V5 00 BLOWER PERFORMANCE FACTORY BLOWER SPEED SETTINGS GSR2V5 80 GSR2V5 00 Low Speed Heat/Cool tap 2 Low Speed Heat/Cool tap 2 High Speed Cooling tap High Speed Cooling tap High Speed Heat tap 6 High Speed Heat tap 7 Air Volume (cfm) @ Various Speeds Pressure (in. wg.) 0 thru.80 Tap Tap 2 Tap 3 Tap 4 Tap 5 Tap 6 Tap 7 Tap 8 Tap 9 Tap 0 Tap 890 990 230 425 605 735 900 205 2090 2090 TE All air data is measured external to the unit with the air filter in place. *Blower maintains a constant CFM throughout a range of varying static pressures. Page 0

UNIT COMPONENTS UPFLOW Q" UNITS DIFFERENTIAL PRESSURE SWITCH LIMIT CONTROL AIR INTAKE PVC CONNECTION GAS VALVE IGNITION CONTROL AIR FLAPPER VALVE INSULATION SPARK PLUG & SENSOR ACCESS PANEL TERMINAL STRIP TB EXPANSION TANK GAS FLAPPER VALVE & ORIFICE ASSEMBLY HEATING COMPARTMENT CONTROL BOX PURGE BLOWER EXHAUST OUTLET DOOR INTERLOCK SAFETY SWITCH BLOWER (ICM2 SHOWN WITH VSP2 ) UNIT COMPONENTS HORIZONTAL/REVERSE FLOW V" UNITS SPARK PLUG & SENSOR ACCESS PANEL HEATING COMPARTMENT IGNITION CONTROL PURGE BLOWER AIR INTAKE PVC CONNECTION DIFFERENTIAL PRESSURE SWITCH TERMINAL STRIP TB VSP2 CONTROL BOARD BLOWER INSULATION AIR FLAPPER VALVE GAS FLAPPER VALVE & ORIFICE ASSEMBLY MODULATION/LIMIT CONTROL EXPANSION TANK GAS VALVE EXHAUST OUTLET CONTROL BOX DOOR INTERLOCK SAFETY SWITCH Page

I APPLICATION G2/GSR2 unit input range covers 40,000 through 00,000 Btuh. See specifications table. G2/GSR2 models use the same cabinet size as the ex isting G4/GSR4 furnace line. All units in the G2/GSR2 series use direct drive blowers and accept cooling coils in nominal tonnages up to 5 tons for the 80, 00. Consult the Engineering Handbook for proper sizing. Slab filters are used for either bottom or side return air in G2 models and top return air in GSR2 models. II UNIT COMPONENTS A Control Box (Figures and 2) The G2 control box is located below the air intake chamber. 40, 60 and 80 control boxes are designed to open over the exhaust PVC line when the unit is set up for right hand dis charge of exhaust. 00 control boxes are designed to open over the exhaust PVC line when the unit is set up for left hand discharge of exhaust. The GSR2 control box is located in the lower right hand corner of the heating compartment in horizontal installa tions and in the upper right hand corner of the heating compartment in reverse flow applications. G2Q CONTROL BOX FAN TIMING CONTROL (A28) TRANSFORMER T TERMINAL STRIP TB G2V CONTROL BOX GROUNDING LUG TERMINAL BLOCK TB2 INDOOR BLOWER RELAY K3 GSR2Q CONTROL BOX TERMINAL STRIP TB TERMINAL BLOCK TB2 GROUNDING LUG FAN TIMING CONTROL (A28) INDOOR DOOR INTERLOCK BLOWER SAFETY SWITCH RELAY (K3) (S5) TRANSFORMER T GSR2V CONTROL BOX TERMINAL STRIP TB TERMINAL BLOCK TB2 ACCESSORY RELAY K09 TRANSFORMER T FIGURE GROUNDING LUG DOOR INTERLOCK SAFETY SWITCH (S5) TRANSFORMER T TERMINAL BLOCK TB2 ACCESSORY RELAY K09 GROUNDING LUG TERMINAL STRIP TB FIGURE 2 Control Transformer T A transformer (T) located inside the control box provides power to the low voltage section of the unit. Transformers are rated at 30VA for Q" models and 50VA for V" models with a 20V primary and 24V secondary. 2 Transformer Fuse F Transformer T is protected by a fuse F. See table for fuse ratings. The fuse is located on the TB terminal strip. TABLE TRANSFORMER FUSE APPLICATION F FUSE RATING V" MODELS Q" MODELS 3 AMP MDX SLOW BLOW 2 AMP AGC FAST BLOW Page 2

3 Low Voltage Terminal Strip TB A low voltage terminal strip (TB) with thermostat markings is located outside the control box. See figures 3, 4 and 5. W W2 R Q" SERIES TERMINAL STRIP TB FUSE 2 AMP AGC FAST BLOW R W Y G C FIGURE 3 R 24VAC OUTPUT W HEATING DEMAND INPUT Y COOLING WIRING G BLOWER DEMAND INPUT C COMMON *Y is used as a terminal block to connect the outdoor unit to the thermostat. It makes no internal connection to unit controls. V" SERIES IMC TERMINAL STRIP TB G Y Y2 DS C HB FUSE 3 AMP MDX SLOW BLOW R 24VAC OUTPUT W st STAGE HEATING DEMAND INPUT W2 2nd STAGE HEATING DEMAND INPUT G BLOWER DEMAND INPUT Y st STAGE COOLING CONNECTION Y2 2nd STAGE COOLING CONNECTION DS PWM, AC OR DC INPUT C COMMON 24 VAC HB SENSING OUTPUT FOR HEATING BLOWER *Y is used as a terminal block to connect the outdoor unit to the thermostat. It makes no internal connection to unit controls. FIGURE 4 V" SERIES IMC2 TERMINAL STRIP TB G R C NM W W2 DS FIGURE 5 Y Y2 FUSE 3 AMP MDX SLOW BLOW The following terminal designations are unique to V" se ries with the IMC motor: R" This signal provides 24VAC to the thermostat and, in zoning applications, to the zone control. DS " This is the speed regulation input that switches the blower from LOW to HIGH speed in cooling mode. DS is the PWM (pulse width modulation) input in zoning ap plications. When used with the CCB it is a 2 7VDC signal. When used without the CCB or Harmony it is a 24 VAC signal from the thermostat. HB" This is an output signal, to tell the zone control when the electronically controlled blower is energized from either a heating demand or a tripped secondary limit. The following terminal designations are unique to V" series units with the IMC2 motor: R" This signal provides 24VAC to the thermostat and, in Har mony II zoning applications, to the control center. DS" This is the speed regulation input that switches the blower from LOW to HIGH speed, in cooling mode. DS is the PWM (pulse width modulation) in put in zoning applications that use Harmony II zon ing system. NM" This terminal is used for non zoning (Non Harmony), non modulating applications where heat exchanger mod ulation is T desired. The heat demand from the ther mostat should be wired to this terminal instead of W. CAUTION For units with the IMC2 motor do not connect the heat demand wire to both the W and the NM ter minals. Damage to the unit will occur. Use the W terminal for zoning (Harmony) applications and the NM terminal for non zoning (Non Harmony) applications. W" This terminal is used for zoning (Harmony) modulating applications where heat exchanger modulation IS de sired. This terminal is also used for the first stage of a two stage heating application. W2" This terminal is used for two stage heating. Two stage heating is not available when using the non modulating NM terminal. For field wiring to terminal strips see figures 3, 4 and 5. See tables 2 and 3 for jumper connections. TABLE 2 IMC MOTOR TB TERMINAL STRIP JUMPERS V" MODELS APPLICATION JUMPERS REQUIRED Single Stage Heating HB" Jumpered to W2" Single Speed Compressor, DS" Jumpered to G" No CCB, Without Harmony Two Speed Compressor, No DS" Jumpered to Y2" CCB, Without Harmony CCB With Single Speed or Two No Jumpers Required* Speed Compressor, Without Harmony *Never Jumper Y2" to DS" when a CCB control is used. Damage to the CCB will occur. TABLE 3 IMC2 MOTOR TB TERMINAL STRIP JUMPERS V" MODELS APPLICATION JUMPERS REQUIRED Single Stage Heating See Figure 3 For Pin Setting Single Speed Compressor, DS" Jumpered to G" No CCB, Without Harmony Two Speed Compressor, No CCB, Without Harmony CCB With Single Speed or Two Speed Compressor, Without Harmony *Never Jumper Y2" to DS" when a CCB control is used. Damage to the CCB will occur. DS" Jumpered to Y2" No Jumpers Required* TE For single stage heat application with the IMC2 mo tor, VSP2 will have a selector pin for single or second stage heating. See figure 3. Refer to tables 8 through 22 for a complete listing of all jump ers used. Page 3

If a two speed condensing unit is used and Harmony or CCB is not used jumper DS to Y2. The blower will operate on the low speed heat/cool tap during first stage cooling (low speed compressor). During second stage cooling (high speed com pressor), the blower will operate on the high speed cooling tap. If a single speed condensing unit and no Harmony or CCB is used, jumper DS to G. The blower will operate on the high speed cooling tap during the cooling mode. CAUTION Never jumper Y2" to DS" if a CCB control is used. Damage to the CCB control will occur. IMPORTANT Y2" must be jumpered to DS" in two speed, non zoned application when CCB is not used. 4 Terminal Block TB2 (Figure 6) Line voltage is routed to the unit through a power supply termi nal block (TB2) located inside the control box. The terminal block is energized at all times. For GC equipped units Watchguard is enabled with a heating demand. After one hour (unit locked out or run ning) of continuous thermostat demand, watchguard opens for two minutes then closes remaking thermostat demand W. This resets electronic ignition control A3. After this break, a thermostat de WATCHGUARD CONTROL BOARD mand for heat will allow the unit to (A8) fire. If ignition is not successful unit lockout occurs. If successful the unit operates. Lockouts are usually attributed to low gas line pressure. For units equipped with a GC 3 or Johnson ignition con FIGURE 7 trol, the Watchguard is enabled only after the unit locks out because of failed ignition attempts (five tries). The watchguard will then break and remake thermostat de mand after one hour. In Q" units the accessory terminal (ACC) is energized any time there is a blower demand. In V" units the accessory ter minal is energized by the VSP control and is powered when the blower is running. The accessory terminal can be used for accessories such as an electronic air cleaner. TERMINAL BLOCK TB2 ACC L FIGURE 6 5 K3 Indoor Blower Relay Q" Models Only A double pole, double throw indoor blower relay is located in side the control box to provide power to the blower. K3 relay contacts also control the 20V accessory terminal located on terminal strip TB2. N 6 Watchguard Control Board (A8) GC Control Only The watchguard control board is illustrated in figure 7. Watchguard serves as an automatic electronic ignition reset device. Watchguard is a N.C. SPST self resetting timer wired in series with W thermostat demand. It is built into the ignition control on all units equipped with GC 3 or Johnson ignition control. On GC equipped units it is externally mounted. 7 Fan Timing Control A28 Q"Units Only (Figure 8) A fan timing control (A28) located in the con trol box is used in Q" models to regulate fan on and fan off timings. Fan on timing is the amount of time that the unit operates in a heat ing demand without the FIGURE 8 blower running during initial start up. Fan off timing is the amount of time that the blower continues to run after heating demand has been terminated. Fan timing control part number 5K460 (figure 8) has a factory set fan on time of 45 sec onds and is adjustable from 30 to 60 seconds. Fan off timing is factory set at80 seconds and is adjustable from 20 to 240 seconds. Fan timing control with early part number 76H3 has a fan on timing set at 45 seconds and is not adjustable. Fan timing control with part number 97H03 and 79J65 has an ad justable fan on timing from 30 to 60 seconds. Fan off timing is factory set at 80 seconds and is adjustable from 20 through 240 seconds. During fan off timing blower operates on low speed heat/cool tap. Page 4

8 K9 Isolation (Heat) Relay Q" Models Only Fan timing control (A28) with part number 79J65 con tains a single pole, single throw isolation relay (K9). When there is a heat demand through W, K9 is ener gized closing the normally open contacts K9 in the ignition circuit. The addition of an isolation relay in the W circuit will eliminate electrical noise feeding from the electronic thermostat back to the electronic ignition control. 9 K09 Accessory Relay V" Models Only G2V 5 to 8 & GSR2V 0 to 5 A single pole, single throw accessory relay is located inside the control box to provide power to additional accessories which may be used with the G2V / GSR2V. 0 VSP Blower Control Board (A24) V" Models Only G2V to 3 & GSR2V to 9 (Figure 9) VSP BLOWER CONTROL BOARD (A24) FRONT VIEW J46 2 9 6 4 OUTPUT 3 PLUG DS3 DS2 DS DIAGSTIC LEDS 20V ACCESSORY TERMINAL L LINE VOLTAGE ACC L J73 VSP CONTROL PLUG 90 50 20 270 FAN OFF TIMING PINS 2 Senses limit trip condition and turns on the blower. 3 Controls the accessory relay. 4 Interfaces the 24VAC thermostat with the blower. When operating in heating mode, VSP controls the blower and monitors limit and gas valve operation. The VSP con trols the fan on" and fan off" timings. Fan on timings are pre set and non adjustable. Fan off timings are adjustable. Fan on timing is the amount of time the unit operates before the blower is started. This period allows for heat exchanger warm up. The fan on timing is pre set at 45 seconds and is not adjustable. Fan Off timings (time that blower operates after heating demand has been satisfied) are determined by the ar rangement of a jumper on the VSP board. To adjust fan off timings, gently disconnect jumper and reposition it across pins corresponding with new timing (see figure 0). The fan off timing is factory set at 270 seconds. IMPORTANT If fan off time is too low, residual heat in heat ex changer may cause primary limit S0 to trip result ing in frequent cycling of blower. If this occurs, ad just blower to longer time setting. TIMING JUMPER 270 DANGER Shock Hazard. VSP fan control is connected to line voltage. Discon nect power to unit before changing pin timings. Can cause personal injury or control damage. FAN OFF TIME ADJUSTMENT 20 To adjust fan off timings: Remove jumper from VSP and se lect one of the other pin combina tions to achieve the desired time. Leave jumper off to achieve 330 second fan off timing. TIMING PINS (seconds) FIGURE 9 The VSP (A24), a printed circuit board located in the con trol box, serves four primary functions: Controls blower timings during heating to accommo date the required initial heat up and cool down times of the heat exchanger. 50 90 FIGURE 0 Fan off timing is factory set at 270 seconds The VSP includes a 20 VAC accessory terminal. The ter minal is wired directly to terminal block TB2 and powers the accessory connection on the terminal block. The terminal is energized when the blower is running. It can be used for any desired accessory equipment such as an electronic air cleaner or humidifier. Page 5

VSP provides an interface between the 24VAC indoor thermostat signal and the direct current digital signal to the blower motor. The control is responsible for energizing the blower motor in response to thermostat demand and for converting thermostat demand from 24VAC to 24VAC half rectified (DC pulse) see figure. The motor controller (in side the blower motor) is responsible for regulating blower speed to maintain the desired CFM. 3 69 2 2 3 4 VSP BLOWER CONTROL BOARD (A24) J73 Inputs J46 Outputs DS DS2 DS3 270 50 20 J46 PIN Common PIN 2 24VAC /2 rectified ON/OFF PIN 3 24VAC /2 rectified HEAT PIN 4 2 7VDC (Hi/Low) if CCB is used, 2VAC if CCB or Harmony is not used. PWM signal if Harmony is used. J73 PIN 24VAC COMMON PIN 2 24VAC INPUT FROM TSTAT TERM G PIN 3 24VAC POWER TO TSTAT PIN 4 2 7VDC INPUT FROM HUMIDITY CNTRL. TERM DS or 24VAC FROM TSTAT TERMINAL Y2 IF CCB OR HARMONY IS T USED. PWM SIGNAL FROM HARMONY. PIN 5 OUTPUT SIGNAL CONFIRMING HEATING BLOWER SIGNAL PIN 6 24VAC INPUT FROM TSTAT TERM W2 PIN 7 24VAC INPUT SIGNAL FROM EXTERNAL LIMIT PIN 8 24VAC POWER FOR PIN 9 VSP 24VAC INPUT FROM GAS VALVE PIN 0 24VAC OUTPUT FROM VSP TO IGNITION CONTROL A3 PIN 24VAC INPUT FROM FAN LIMIT CONTROL PIN 2 24VAC INPUT FROM FAN LIMIT CONTROL Wires from J46 connect directly to indoor blower B3 jack J49. Volt age on pins 2 and 3 are half rectified AC (DC pulse). Measured volt age will vary depending on the type of meter used. 90 ACC L IMPORTANT 24 VAC half wave rectified (DC pulse), when mea sured with a meter, may appear as a lower or high er voltage depending on the make of the meter. Rather than attempting to measure the output voltage of A24, see G2V/GSR2V V" BLOWER AND VSP BLOWER CONTROL BOARD TROU BLESHOOTING FLOW CHART in the TROUBLE SHOOTING section of this manual. Diagnostic LED Lights Three diagnostic LED lights are provided on the control for troubleshooting. The three lights DS, DS2 and DS3 (fig ure 2) are on/off," hi speed heat" and high speed cool." In the heating and cooling mode, the on/off LED (DS) is lit indicating the blower is operating on low speed heat/cool tap. It is lit whenever a 24VAC thermostat demand is sup plied to the control (jackplug JP73 pin 2). When the hi speed heat"(ds2) and the on/off (DS) LED are both lit the blower is operating on high speed heating tap (2 7VDC from CCB terminal DS or 24VAC from Y2 if CCB is not used). During dehumidification mode, the CCB turns off the DS output and the blower operates on low speed heat/ cool tap. When the high speed cool" (DS3) and the on/off" (DS) LED are both lit the blower is operating on high speed cool tap. If the unit is switched from a heating demand to a 2nd stage cooling demand, all three lights (DS, DS2 and DS3) may be energized for a short time. During this period, blower operates on high speed heating tap. 34 volts 0 volts 34 volts VOLTAGES INTO VSP Voltage across J73 pins 8 to and 3 to is 24VAC as shown here. Refer to unit wiring diagram. 24VAC @ 60Hz. Voltage across J73 pins 4 to is approximately 2 7VDC (straight voltage) if CCB is used. A PWM signal if Harmony is used. If CCB or Harmony is not used, pin 4 to voltage is 2VAC. VOLTAGES FROM VSP TO ELECTRONICALLY CONTROLLED BLOWER MOTOR Voltage across J46 pins 2 to and 3 to is half rectified AC as shown here. Refer to unit wiring diagram. Approx. 34 volts 0 volts Voltage across J46 pins 4 to, is approximately 2 7VDC if CCB is used. If CCB or Har mony is not used, pin 4 to voltage is approximately 2VAC. A PWM signal if Harmony is used. FIGURE 24VAC Half Rectified (DC Pulse) @ 60Hz. VSP BLOWER CONTROL BOARD (A24) FRONT VIEW (PARTIAL) J46 9 6 OUTPUT 2 3 PLUG DS3 DS2 DS DIAGSTIC LEDS J73 VSP CONTROL T LIT LIT PLUG INPUTS DS3 DS2 DS UNIT OPERATING ON LOW SPEED DS3 DS2 DS HEAT/COOL TAP UNIT OPERATING ON HIGH SPEED HEAT TAP DS3 DS2 DS UNIT OPERATING ON HIGH SPEED COOL TAP DS3 DS2 DS UNIT SWITCHED FROM HEATING DEMAND TO 2nd STAGE COOLING UNIT OPERATES ON HIGH SPEED HEAT TAP MOMENTARILY Any other combination could indicate possible trouble with the VSP refer to TROUBLESHOOTING section of this manual FIGURE 2 Page 6

B VSP2 Blower Control Board (A24) V" Models Only G2V 5 to 8 & GSR2V 0 to 5 (Figure 3) VSP2 BLOWER CONTROL BOARD (A24) J46 IMPORTANT If fan off time is too low, residual heat in heat ex changer may cause primary limit S0 to trip result ing in frequent cycling of blower. If this occurs, ad just blower to longer time setting. G2V / GSR2V units are equipped with a variable speed mo tor that is capable of maintaining a specified CFM throughout the external static range. The unit uses the VSP2 variable speed control board, located in the blower compartment, which controls the blower speed and provides diagnostic LEDs. The control has both a non adjustable, factory preset ON" fan timing delay and an adjustable OFF" fan timing delay (see figure 5). The VSP2 also senses limit trip condition and turns on the blower. The G2V / GSR2V limit switch is located in the vesti bule wall. When excess heat is sensed in the heat exchanger, the limit switch will open and interrupt the current to the gas valve, while at the same time the VSP2 energizes the blower on heating speed. The limit automatically resets when the unit temperature returns to normal and the blower is de ener gized. Diagnostic LEDs located on the VSP2 control board are pro vided to aid in identifying the unit s mode of operation. Certain scenarios will arise depending on the jumper positions. HEATING STAGE SELECTOR PIN HTG. BLOWER 2 PIN 3 C 24 VAC common. VSP2 BLOWER CONTROL BOARD (A24) JP JP2 HIGH LOW ADJUST HEAT JP2 3 PIN PLUG (BOARD TO MOTOR) 2 3 4 2 3 4 SELECTOR PINS HEAT TEST + RM DS3 HI/LOW DS2 ON/OFF DS DIAGSTIC DS LEDS FIGURE 3 2 3 4 DS4 CFM FAN OFF TIMING PINS 20 270 JP 5 PIN (BOARD TO FURNACE) 50 90 34 volts 0 volts 34 volts VOLTAGES INTO VSP2 Voltage across J73 pins 3 to and 6 to is 24VAC as shown here. Refer to unit wiring diagram. 24VAC @ 60Hz. Voltage across J73 pins 4 to is approximately 5 20VDC (straight voltage) if CCB is used. If Harmony is used a voltage of 0 25VDC should be present. If CCB or Harmony is not used, pin 4 to voltage is 2VAC. VOLTAGES FROM VSP2 TO ELECTRONICALLY CONTROLLED BLOWER MOTOR Voltage across J46 pins 6 to 3 and to 3 is half rectified AC as shown here. Refer to unit wiring diagram. Approx. 34 volts 0 volts J73 HIGH LOW ADJUST HEAT 2 3 4 HTG. BLOWER 2 3 4 HEAT 2 DS2 ON/OFF Voltage across J46 pins 8 and 9 to 3, is approximately 5 20VDC if CCB is used. If CCB or Harmony is not used, pins 8 and 9 to 3 voltage is approximately 2VAC. If Harmony is used a voltage of 0 25VDC should be present. DS3 FIGURE 4 TEST + RM HI/LOW DS J73 PIN C 24 VAC common. PIN 2 G Input signal from thermostat s fan signal. PIN 3 W2 Input signal for second stage heat from the thermostat. PIN 4 DS Input signal for the blower speed regulation. PIN 5 Limit Input signal from the external limit. PIN 6 R 24 VAC power to the thermostat. PIN 7 C 24 VAC common. Pin 8 C 24 VAC common. PIN 9 CI Input signal from the fan limit control. PIN 0 CO Output signal to the ignition control. PIN HT Input signal from the fan limit control. PIN 2 ACC 24 VAC accessory output. PIN 3 24V Input 24 VAC power for the VSP2. PIN 4 24V Input 24 VAC power for the VSP2. PIN 5 V Input signal from the gas line. J46 PIN Heat Heat speed input signal to the ICM2 motor. PIN 2 C 24 VAC common. PIN 4 High Tap High Speed programming input. PIN 5 Low Tap Low speed programming input. PIN 6 On / Off On / off output signal to the ICM2 motor. PIN 7 Adjust Tap ICM2 mode selection. PIN 8 Hi / Low Speed regulate input signal to the ICM2 motor. PIN 9 Hi / Low Speed regulate input signal to the ICM2 motor. PIN 0 Ref. V ICM2 reference voltage. PIN Heat Tap Heating blower speed programming. PIN 2 C 24 VAC common. PIN 3 cfm Motor speed diagnostic signal. 270 2 3 4 20 50 DS4 CFM 90 24VAC Half Rectified (DC Pulse) @ 60Hz. Page 7

IMPORTANT 24 VAC half wave rectified (DC pulse), when mea sured with a meter, may appear as a lower or high er voltage depending on the make of the meter. Rather than attempting to measure the output voltage of A24, see G2V/GSR2V V" BLOWER AND VSP2 BLOWER CONTROL BOARD TROU BLESHOOTING FLOW CHART in the TROUBLE SHOOTING section of this manual. Diagnostic LED Lights DS3 ON/OFF" ON/OFF DS3 indicates there is a demand for the blower motor to run. When the ON/OFF LED DS3 is lit, a demand is being sent to the motor. In heating mode only, there is a 45 second fan ON" delay in energizing ON/OFF LED DS3. The light will not go off until adjustable fan OFF" delay has expired. If ON/OFF LED DS3 is on and both HIGH/LOW LED DS & HEAT LED DS2 are off, the motor will operate in low speed. a DS2 HEAT" If HEAT LED DS2 is on, the blower is running in the heat speed according to the HEAT" jumper setting. In heating mode only, there is a 45 second delay in energizing HEAT LED DS2. Light will not go off until adjustable fan OFF" delay has expired. b DS HI/LOW" MODEL HIGH/LOW LED DS indicates whether the blower is op erating in high or low speed. When the light is off, the blow er is running in low speed according to the LOW" jumper setting. When HIGH/LOW LED DS is on, the blower is op erating in high speed according to the HIGH" jumper set ting. c DS4 CFM" CFM LED DS4 indicates the CFM the unit is operating, according to the jumper settings. The light flashes once for approximately every 00 CFM. For example, if the unit is operating at 000 CFM, CFM LED DS4 will flash 0 times. If the CFM is 2050, CFM LED DS4 will flash 20 full times plus one fast or half flash. At times the light may appear to flicker or glow. This takes place when the control is communicating with the motor be tween cycles. This is normal operation. The appropriate speed according to application and CFM need is selected by moving jumper pins. TE On Harmony II zoning applications in the heating mode, the highest speed obtainable is the same as the highest cooling speed selection. Also, the heating speed (heat jumper position) is only used when the primary limit has been tripped. In non zoning applications, refer to the section on the VSP2 control. Jumper Settings IMPORTANT Before changing jumper setting, make sure the motor has completely stopped. Any jumper set ting change will not take place while the motor is running. To change jumper positions, gently pull the jumper off the pins and place it on the desired set of pins. The following section outlines the different jumper selections available and con ditions associated with each one. Refer to figure 3 for identification. After the CFM for each application has been determined, the jumper settings must be adjusted to reflect those given in the tables on pages 7 and 8. Using the tables, determine which row of CFM volumes most closely matches the de sired CFM. Once a specific row has been chosen (+, R MAL, or ), CFM volumes from other rows cannot be used. Below are the descriptions of each of the jumper selec tions. Refer to table 4 for factory settings. Refer to the tables on pages 7 and 8 for the approximate air volume for each set ting. NUMBER TABLE 4 VSP2 FACTORY SETTINGS HIGH LOW ADJUST HEA T G2V5 80 G2V3 60 G2V5 00 G2V3 80 4 4 RM RM 2 GSR2V5 80 4 RM GSR2V5 00 4 RM 2 a ADJUST" The ADJUST pins allow the motor to run at normal speed, approximately 0% higher, or approximately 0% lower than normal speed. The tables on pages 7 and 8 give three rows ( +, RMAL, and ) with their respective CFM volumes. No tice that the normal adjustment setting for heat speed position #3 in the G2V5 80/00 blower data table is 2080 CFM. The + adjustment setting for that position is 2270 CFM and for the adjustment setting is 860 CFM. After the adjustment set ting has been determined, chose the remainder speed jump er settings from those offered in the table. The TEST pin is available to bypass the VSP2 control and run the motor at approximately 70% to test that the mo tor is operational. This is beneficial primarily in trouble shooting. G must be energized for motor to run. Page 8

b HEATING BLOWER" Place the HEATING BLOWER jumper across the first and second pins for single stage heating operation (position #). For two stage operation, place the jumper across the second and third pins (position #2). The position of the jumper determines which set of speed jumpers is activated. When the HEATING BLOWER jumper is across the first and second pins, the HEAT jumper selec tions are activated when W is energized. If the jumper is across the second and third pins, the LOW jumper selections are activated when W is energized. HEAT jumper selections are activated when W2 is ener gized. TE In Harmony II zoning applications, HEATING BLOWER jumper must be in position #2. c HEAT" The HEAT jumper is used to set the blower speed to obtain the required CFM as outlined in HEAT SPEED section of the tables on pages 7 and 8. If a lower heating speed (than one that is listed in HEAT SPEED section) is required, the LOW jumper may be used to set the heating speed. This is done by first placing the LOW jumper in the desired CFM position and then placing the HTG. BLOWER jumper across the second and third pins (regardless of the actual stage). Doing so will activate the low speed jumper setting when W is energized. d HIGH" CONNECT The HIGH jumper is used to determine the CFM during cooling speed. These jumper selections are activated when G and DS terminals are energized. e LOW" The LOW jumper is used to determine CFM during low speed cooling. These jumper selections are activated when G is energized. The LOW jumper may also be used for low speed heating. See the HEAT" section for details. f FAN OFF" Fan OFF" timings (time that the blower operates after the heat demand has been satisfied) are determined by the ar rangement of a jumper on the VSP2 board. See fig ure 5. To adjust fan OFF" timings, gently disconnect the jumper and reposition it across pins corresponding with the new timing. Fan OFF" time is factory set at 270 seconds. Fan ON" time is factory set at 45 seconds and is not adjust able. WARNING MAKE SURE TO DISCONNECT POWER BEFORE CHANGING FAN OFF" TIMINGS. TIMING JUMPER 270 FAN OFF TIME ADJUSTMENT 50 90 20 To adjust fan off timings: Remove jumper from VSP2 and select one of the other pin combina tions to achieve the desired time. Leave jumper off to achieve 330 second fan off timing. TIMING PINS (seconds) Fan off timing is factory set at 270 seconds FIGURE 5 TE If fan OFF" time is too low, residual heat in heat exchanger may cause primary limit S0 to trip resulting in frequent cycling of blower. If this occurs, adjust blower to longer time setting. C Limit Control Modulation/Limit Control (Figure 6) HONEYWELL LIMIT CONTROL MODULATION/ LIMIT CONTROL ALL MODELS S0/S78 S78 N.C. IS A /4" QUICK S78 N.C. S0 S78 SWING S78 N.O. FIGURE 6 S0 Limit Control (S0) Q" Models G2Q/GSR2Q models use a Honeywell limit control. See unit components illustration (page ) for exact location. If heat exchanger temperatures rise above limit setting (see table 5), the self resetting limit interrupts power to ignition control A3, and fan timing control A28 will maintain the blower to cool down the unit. This is a safety shut down function. S0 auto matically resets when temperatures inside the heat exchange assembly drop below limit setting. Do not change factory limit setting. S0 is set to limit maximum discharge air temperature. Page 9