CU-MS & AH-HW Mini-Split Series

Similar documents
VAC1 Series - Division 2 / Zone 2

VAC1 Series-Division 2 / Zone 2

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton

Explosion Proof Hazardous Location Roof Top A/C Units

VACPB1 Series - 60 Hz Models

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

FX5 Series Explosion-Proof Electric Air Heaters

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Comfort. Description. Applications

PAJ3. Product Specifications

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Precise Temperature Control; Compact Footprint

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Features. protection. durable. low vibration. application. optional. Indoor unit Outdoor unit (side fan) Outdoor unit (top fan)

CENTRAL SPLIT UNIT UNIC

Advance Release September 2009

Description. Applications

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

2 shp 13 lc 1 36 t - 1 a

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Split System Cooling Product & Performance Data

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Smoke detection in hazardous areas:

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

RGE 13 A T - 1 A

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

EVLPF Series Compact Fluorescent

AIR COOLED PACKAGED CHILLER

Concealed Ducted Split Series R-407C MBH

American Brand with Global Reach. Model: SMLW-SAGL

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Split System Heat Pump Product Data

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

48TM GAS HEATING/ELECTRIC COOLING UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

50TM TFF COMBINATION HEATING/COOLING UNITS

Product Specifications. Vertical Floor Consoles By First Co.

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

FE1 Explosion-Proof Electric Air Heaters

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Performance Data. curus Component Recognized; File No. E IP 20

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

50TM COMBINATION HEATING/COOLING UNITS

General Description. Operation

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Indoor Air Handlers with Compressors MVS and MVW

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

13 GEP A L P - 1 A

Self-Contained Reverse Cycle Air Conditioners

SMALL AIR COOLED CONDENSERS

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Q-TEC QC-Series Chilled Water Air Conditioner

Portable Vertical Air-Conditioning and Heating Systems

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Call us today! (800)

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Split System Cooling Product Data

WJH4 Product Specifications

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Condensing Units & Air Handlers

Nuclear Electric Heating

Description. Applications

LIGHTING in Hazardous (Classified) Locations

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Transcription:

CU-MS & A-W Mini-Split Series Explosion Proof Mini-Split Air Conditioning System azardous Location N.E.C. and I.E.C. Approved 60 ertz Models : 12,000-36,000 /R General Purpose, Division I/II 50 ertz, igh Ambient, orizontal Airflow & Custom Designs Available Contact Safe Air Technology Sales Team for Assistance Standard Features All Electrical Components are UL & CSA Approved Explosion Proof Built-In Operational Controls Easily Accessible Components for Fast and Easy Maintenance Non Sparking Blower and Condenser Designs N.E.C. Approved XP2 Overload Protection Installed on Motor and Compressor Aluminum Fin and Copper Tube Coils for Maximum eat Transfer Single Point Main Power Connection Port N.E.C. Certificate of Conformance Issued COPYRIGT 2016 Safe Air Technology R0416 Offering The Keys to Success: Quality Pricing On Time Delivery

System Description Safe Air Technology CU-MS and A-W Mini-Split Systems are designed to provide cooling for industrial, severe duty, and marine applications. Our CU-MS and A-W Mini-Split product line has been carefully engineered and manufactured to ensure a quality product that will provide many years of reliable service. Safe Air Technology will provide NEC Certificates of Conformance for each CU-MS and A-W Mini-Split unit to show compliance with National Electric Code Articles 500-515 guidelines for explosion proof equipment in hazardous locations. Please contact our Sales Engineering Department at or by phone at with any questions that you may have. We look forward to working with you and serving your VAC/R needs. System Applications Industrial Refineries Chemical Plants Offshore Platforms Gas Plants and Pipelines Fuel Transfer Docks and Pumping Stations Analyzer Buildings MCC Rooms Control Rooms Available Options Available Designs -ADC Adsil Coated Coils and All Copper Lines for Corrosion Protection -B Group B Classification -CC Copper Tube and Copper Fin Coils -CRT Export Crate for Sea/Air Shipping -EXP 646 Micro Epoxy Coated ousing -FAL Low Volume Fresh Air Intake -CC eresite Coated Coils -G ot Gas Bypass Valve Installed igh Ambient Temperatures 50 ertz Power Supply Safe Air Technology Also Offers Standard Minisplit Systems Designed for the Following Applications The CU-MS and A-W Series Minisplit Systems Can Be Designed to Operate in Temperatures up to 115 o F (46 o C). Custom Systems Are Available for Applications that Exceed These Temperatures. 50 ertz Options Are Available, Please Contact Sales for -MOD -S4 -S6 Custom Modification (Consult Sales Dept.) 304 Stainless Steel ousing 316 Stainless Steel ousing Custom Applications If your Project Requires an Additional Specification Not Listed in This Catalog, Please Contact the Sales -SVI -RMT Service Port Installed Remote Control Box NOTE: If an option you require due to your specifications is not listed, please contact our Sales Engineering Department.

CU-MS Series Mini-Split Condensing Unit General Purpose Design CU-MS Series General Purpose Mini Split Condensing Units are designed to operate in a Non-Classified Area with either Explosion Proof or General Purpose A-W Series Mini-Split Air andler Units. MCA eight Depth Width Sound Unit Weight Volts/Ph/z Level (Db) (LB/KG) CU-MS-V-D-12000-2-NXP-*** 12,000 208-230/1/60 13 25/635 29.75/ 755 29.75/ 755 76 122/55.3 CU-MS-V-D-18000-2-NXP-*** 18,000 208-230/1/60 13 25/635 29.75/ 755 29.75/ 755 76 127/57.6 CU-MS-V-D-24000-2-NXP-*** 24,000 208-230/1/60 15 25/635 29.75/ 755 29.75/ 755 75.2 141/64.0 CU-MS-V-D-30000-2-NXP-*** 30,000 208-230/1/60 17 27/685 29.75/ 755 29.75/ 755 74 151/68.5 CU-MS-V-D-36000-2-NXP-*** 36,000 208-230/1/60 19 27/685 33.75/ 857 33.75/ 857 76 171/77.6 D W Note: Dimensions Subject to Change, Contact the Sales Engineering Department for Updated Dimensions

CU-MS Series Mini-Split Condensing Unit Division II/ Zone II Design CU-MS Series Division II/ Zone II Mini Split Condensing Units are designed to operate in a Division II/ Zone II Area with either Explosion Proof or General Purpose A-W Series Mini-Split Air andler Units. MCA eight Length Width Sound Unit Weight Volts/Ph/z (IN/ MM) Level (Db) (LB/KG) CU-MS-V-D-12000-2-ICD2-*** 12,000 208-230/1/60 13 25/635 29.75/ 755 29.75/ 755 76 122/55.3 CU-MS-V-D-18000-2-ICD2-*** 18,000 208-230/1/60 13 25/635 29.75/ 755 29.75/ 755 76 127/57.6 CU-MS-V-D-24000-2-ICD2-*** 24,000 208-230/1/60 15 25/635 29.75/ 755 29.75/ 755 75.2 141/64.0 CU-MS-V-D-30000-2-ICD2-*** 30,000 208-230/1/60 17 27/685 29.75/ 755 29.75/ 755 74 151/68.5 CU-MS-V-D-36000-2-ICD2-*** 36,000 208-230/1/60 19 27/685 33.75/ 857 33.75/ 857 76 171/77.6 D W Note: Dimensions Subject to Change, Contact the Sales Engineering Department for Updated Dimensions

CU-MS Series Mini-Split Condensing Unit Division I/ Zone I Design CU-MS Series Division I/ Zone I Mini Split Condensing Units are designed to operate in a Division I/ Zone I Area with either Explosion Proof or General Purpose A-W Series Mini-Split Air andler Units. eight Depth Width Sound Volts/Ph/z Level (Db) CU-MS-V-D-12000-2-ICD1-*** 12,000 208-230/1/60 31/ 788 41.2/ 1047 29.75/ 756 76 CU-MS-V-D-18000-2-ICD1-*** 18,000 208-230/1/60 31/ 788 41.2/ 1047 29.75/ 756 76 CU-MS-V-D-24000-2-ICD1-*** 24,000 208-230/1/60 31/ 788 41.2/ 1047 29.75/ 756 75.2 CU-MS-V-D-30000-2-ICD1-*** 30,000 208-230/1/60 33/ 788 41.2/ 1047 29.75/ 756 74 CU-MS-V-D-36000-2-ICD1-*** 36,000 208-230/1/60 33/ 788 45.25/ 1150 33.75/ 857 76 W W Note: Dimensions Subject to Change, Contact the Sales Engineering Department for Updated Dimensions

CU-MS Series Mini-Split Condensing Unit orizontal Air Flow Design CU-MS Series orizontal Air Flow Mini Split Condensing Units are designed to operate in General Purpose, Division II/ Zone II Area, or Division I/ Zone I Area with either Explosion Proof or General Purpose A-W Series Mini-Split Air azardous Area Classifi- Dimensions Volts/Ph/z cations Available CU-MS--D-18000-2-****-*** 18,000 208-230/1/60 General Purpose (NXP), CU-MS--D-24000-2-****-*** 24,000 208-230/1/60 General Purpose (NXP), ***Dimensions available upon request*** CU-MS--D-30000-2-****-*** 30,000 208-230/1/60 General Purpose (NXP), General Purpose/Division 2 Division 1 Note: Dimensions Subject to Change, Contact the Sales Engineering Department for Updated Dimensions

A-W Series Mini-Split Air andler Unit General Purpose Design A-W Series General Purpose Mini Split Air andler Units are designed to operate in a Non-Classified Area with either Explosion Proof or General Purpose CU-MS Series Mini-Split Air Condensing Units. MCA eight Depth Length Air Flow Unit Weight Volts/Ph/z (CFM/LPS) (LB/KG) A-W-D-12000-N-2-NXP-*** 12,000 208-230/1/60 0.4 19.5 /496 14/356 46 / 1169 400/190 140/63.5 A-W-D-18000-N-2-NXP-*** 18,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-24000-N-2-NXP-*** 24,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-30000-N-2-NXP-*** 30,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 A-W-D-36000-N-2-NXP-*** 36,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 D L Note: Dimensions and Information Are Subject to Change, Contact the Sales Engineering Department for Updated Dimensions and Information.

A-W Series Mini-Split Air andler Unit Division II/ Zone II Design A-W Series Division II/ Zone II Mini Split Air andler Units are designed to operate in a Division II/ Zone II Area with either Explosion Proof or General Purpose CU-MS Series Mini-Split Air Condensing Units. MCA eight Depth Length Air Flow Unit Weight Volts/Ph/z (CFM/LPS) (LB/KG) A-W-D-12000-N-2-ICD2-*** 12,000 208-230/1/60 0.4 19.5 /496 14/356 46 / 1169 400/190 140/63.5 A-W-D-18000-N-2-ICD2-*** 18,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-24000-N-2-ICD2-*** 24,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-30000-N-2-ICD2-*** 30,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 A-W-D-36000-N-2-ICD2-*** 36,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 D L Note: Dimensions and Information Are Subject to Change, Contact the Sales Engineering Department for Updated Dimensions and Information.

A-W Series Mini-Split Air andler Unit Division I/ Zone I Design A-W Series Division I/ Zone I Mini Split Air andler Units are designed to operate in a Division I/ Zone I Area with either Explosion Proof or General Purpose CU-MS Series Mini-Split Air Condensing Units. MCA eight Depth Length Air Flow Unit Weight Volts/Ph/z (CFM/LPS) (LB/KG) A-W-D-12000-N-2-ICD1-*** 12,000 208-230/1/60 0.4 19.5 /496 14/356 46 / 1169 400/190 140/63.5 A-W-D-18000-N-2-ICD1-*** 18,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-24000-N-2-ICD1-*** 24,000 208-230/1/60 0.7 19.5 /496 14/356 46 / 1169 750/350 140/63.5 A-W-D-30000-N-2-ICD1-*** 30,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 A-W-D-36000-N-2-ICD1-*** 36,000 208-230/1/60 1.0 19.5 /496 14/356 46 / 1169 1,100/520 140/63.5 D L Note: Dimensions and Information Are Subject to Change, Contact the Sales Engineering Department for Updated Dimensions and Information.

MS Series Mini Split Control Packages Designation Description Application 0C No Thermostat Included No Thermostat Needed 1C General Purpose Thermostat Interior Non-Classified 2C Explosion Proof Thermostat Division 1 or Division 2 Interior 1C General Purpose Thermostat Thermostat To Control Room Temperature Setpoints Approved for General Purpose Areas 2C Explosion Proof Thermostat XP T-STAT Sealed and Protected from Division 1 and Division 2 azardous and Corrosive Environments

CU-MS Series Mini-Split Condensing Unit Nomenclature Guide CU-MS Design CU= Condensing Unit MS= Mini-Split Design CU MS - D - 12000-2 - ICD2 - ** - **** = orizontal V= Vertical Air Flow Refrigerant D = R410 Refrigerant Cooling 12000= 12,000 / R (1 Ton) 2= 208-230 V/ 1 Ph/ 60 z 2(50)= 220 V/ 1 Ph/ 50 z Classification NXP= Non Explosion Proof ICD2 = Class 1, Groups C & D, Division 2 ICD1 = Class 1, Groups C & D, Division 1 Control Package See Page 9 for Available Options Unit Options -ADC = Adsil Coated Coils -B = Group B Classification -CC = Copper/Copper Coils Installed -CRT = Export Crate Sea or Air -EPX = Epoxy Coated Metal -FAL =Low Volume Fresh Air Intake -CC = eresite Coated Coils -G = ot Gas By Pass Valve Installed -MOD = Custom Modification (See Sales) -S4 = 304 Stainless Steel ousing -S6 = 316 Stainless Steel ousing -SVI = Service Ports Installed

A-W Series Mini-Split Condensing Unit Nomenclature Guide A-W Design CU= Condensing Unit MS= Mini-Split Design A W D - 12000 - N 2 - ICD2 - ** - **** Refrigerant D = R410 Refrigerant Cooling 12000= 12,000 / R (1 Ton) eating N= No eat Installed XKW(E/S) = Standard Electric eat XKW(E/XP)= XP Electric eat 2= 208-230 V/ 1 Ph/ 60 z 2(50)= 220 V/ 1 Ph/ 50 z Classification NXP= Non Explosion Proof ICD2 = Class 1, Groups C & D, Division 2 ICD1 = Class 1, Groups C & D, Division 1 Control Package See Page 9 for Available Options Unit Options -ADC = Adsil Coated Coils -B = Group B Classification -CC = Copper/Copper Coils Installed -CRT = Export Crate Sea or Air -EPX = Epoxy Coated Metal -FAL =Low Volume Fresh Air Intake -CC = eresite Coated Coils -G = ot Gas By Pass Valve Installed -MOD = Custom Modification (See Sales) -S4 = 304 Stainless Steel ousing -S6 = 316 Stainless Steel ousing -SVI = Service Ports Installed

Safe Air Technology Office Locations Safe Air Technology specializes in the engineering and manufacture of Explosion Proof, Corrosion Resistant, and Severe Duty VAC/R systems and Pressurization Equipment. Our explosion proof, severe duty systems are designed to offer a safe solution at a competitive price. We strive to maintain the highest level of quality in both our systems and services. Safe Air Technology is headquartered in Baton Rouge, Louisiana. This allows us to easily serve many of our petrochemical, oil and gas, and industrial clients. To better serve our clients around the world, Safe Air Technology has international offices in Dubai and Singapore. Our international reach has given us the opportunity to work with clients in over 40 countries to design and deliver durable and reliable explosion proof VAC/R systems. At Safe Air Technology, we understand that our clients VAC/R needs are continuously adapting and changing. By forging a relationship with you, we can be better equipped to understand and meet your specific needs as they arise. Our engineering and production team takes pride in every system they deliver, from one of our standard window units to our complex custom design projects. Contact Safe Air Technology and Let Us elp to Keep Industry Safe for Your World. Safe Air Technology Safe Air Technology Safe Air Technology