Genesis Compact (GC) Series Submittal Data

Similar documents
Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GUIDE SPECIFICATIONS AQUARIUS ii

Product Data. Features/Benefits. AQUAZONE 50PCH,PCV Compact Water Source Heat Pumps with PURON Refrigerant (R-410A) 50 Hz

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps

GUIDE SPECIFICATIONS AQUARIUS ii

Commercial High-Efficiency Condensing Units

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

PAJ3. Product Specifications

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

SKYPAK II, 3 Ton Series, gives you a

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SpaceKeeper Console (SKC)

ENGINEERING SPECIFICATIONS

water to water heat pumps

Product Specifications. Vertical Floor Consoles By First Co.

PAR5. Product Specifications

ENGINEERING SPECIFICATIONS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

VariCool VAV Engineering Guide

VERTICAL STACK (VHS) SERIES

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Water-Cooled Self-Contained Units

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SKYPAK II Heating & Cooling Self Contained Packages

PACKAGE AIR CONDITIONER

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SECTION WATER-SOURCE UNITARY HEAT PUMPS

technical guide Water-Cooled Self-Contained Units

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

AVAILABLE WITH ENERGY SAVING ECM MOTOR

Tranquility Console (TRC) Series Submittal Data

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Advance Release September 2009

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

CWA4 Chilled & Hot Water Fan Coil

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

VertiCool Aurora Engineering Guide

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw]

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

DXair Pool Dehumidifiers

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SKYPAK II, 3 Ton Series, gives you a

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

General Description. Operation

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Tranquility Vertical Stack (TSM) Series

Commercial High-Efficiency Condensing Units

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Tranquility 30 Two-Stage (TT) Series

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MAC-120HE-03 Air-Cooled Chiller

Versatec Specification Catalog

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

THE TRANQUILITY 16 COMPACT (TC) SERIES

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

13 GEP A L P - 1 A

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

WJH4 Product Specifications

High Heat COP. High/Low Stage

MERIT Series R-410A - Upflow / Horizontal

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

FCC Fan-Coil Units High-Performance, Vertical

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

MERIT Series R-410A - Upflow / Horizontal

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

Transcription:

SERIES: HZ: UNIT OF MEAS: LANGUAGE: GC - R22 50 SI ENGLISH Genesis Compact (GC) Series Submittal Data Models GCH/V 018B - 060B 50Hz - R22 English Language/SI Units REVISION: 03/13/03 **

MODEL DECODER GC H 036 B C U 3 0 C L B S Model Type GC = Genesis Compact Series Configuration H = Horizontal, V = Vertical Unit Size, Nominal kbtuh 018, 024, 030, 036, 041, 042, 048, 060 Size 041 available in vertical only Revision Level A = Horizontal sizes 042-060 B = Horziontal sizes 018-036 B = All Vertical sizes Voltage & Refrigerant V = 220-240/50/1 R22 U = 380-420/50/3 R22 Controls C = CXM Controller D = DXM Controller L = CXM w/lonworks M = DXM w/lonworks F = CXM - CE Mark G = DXM - CE Mark H = CXM w/lonworks - CE Mark J = DXM w/lonworks - CE Mark Water Coil C = Copper N = Cupro-Nickel Future use 0 = None Cabinet Insulation 3 = Standard Range 4 = Standard Range, Mute Standard Supply Air Options T = Topflow, vertical only V = Topflow - High Static, vertical only B = Back Discharge, horiz. only S = Straight Discharge, horz. only Y = Back Discharge - High Static, horz. only Z = Straight Discharge - High Static, horz. only Return Air Options L = Left Return R = Right Return F = Front Return, vertical 018-030 only Rev:. 6/19/02 A **

PERFORMANCE DATA ARI/ASHRAE/ISO 13256-1 ARI/ASHRAE/ISO 13256-1 Metric (SI) Units Model Liquid Flow (l/s) Air Flow (l/s) Cooling 30 C EWT Heating 20 C EWT Cooling 15 C EWT Heating 10 C EWT Cooling 25 C EWT Heating 0 C EWT Capacity Watts () Capacity Watts () GCV/H018 0.215 236 4,671 3.6 5,529 4.2 GCV/H024 0.284 319 6,119 3.9 7,381 5.0 GCV/H030 0.353 401 6,918 3.7 8,482 4.7 GCV/H036 0.429 472 8,842 3.5 11,458 4.5 GCV041 0.498 543 9,709 3.7 11,991 4.4 GCV/H042 0.505 566 10,513 3.8 13,187 4.5 GCV/H048 0.568 649 12,107 3.8 14,693 4.9 GCV/H060 0.713 779 14,786 3.9 18,714 4.5 Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Capacity Watts () Capacity Watts () Capacity Watts () Capacity Watts () Cooling capacities based upon 27 C DB, 19 C WB entering air temperature Heating capacities based upon 20 C DB, 15 C WB entering air temperature All air flow is rated on high speed All ratings based upon operation at lower voltage of dual voltage rated models Rev.: 02/14/03 B ARI/ASHRAE/ISO 13256-1 English (IP) Units Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Model Liquid Flow (gpm) Air Flow (cfm) Cooling 86 F EWT Heating 68 F EWT Cooling 59 F EWT Heating 50 F EWT Cooling 77 F EWT Heating 32 F EWT Capacity Btuh Btuh/W Capacity Btuh Capacity Btuh Btuh/W Capacity Btuh Capacity Btuh Btuh/W Capacity Btuh GCV/H018 3.4 500 15,937 12.3 18,865 4.2 GCV/H024 4.5 676 20,878 13.3 25,184 5.0 GCV/H030 5.6 850 23,604 12.6 28,941 4.7 GCV/H036 6.8 1000 30,169 11.9 39,095 4.5 GCV041 7.9 1150 33,127 12.6 40,913 4.4 GCV/H042 8.0 1199 35,870 13.0 44,994 4.5 GCV/H048 9.0 1375 41,309 13.0 50,133 4.9 GCV/H060 11.3 1650 50,450 13.3 63,852 4.5 Cooling capacities based upon 80.6 F DB, 66.2 F WB entering air temperature Heating capacities based upon 68 F DB, 59 F WB entering air temperature All air flow is rated on high speed All ratings based upon operation at lower voltage of dual voltage rated models Rev.: 02/14/03 B cfm*0.472 = l/s gpm*0.0631 = l/s in wg*249 = pascals ft of hd *2990 = pascals **

PERFORMANCE DATA GCH/V 018B 236 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/T ot Ratio HR HC 0.146 14.4 5.1 4.0 0.78 1.12 6.2 4.55 5.1 1.26 3.8 37.9 4.05 15 0.215 21.0 5.3 4.1 0.77 1.05 6.4 5.05 5.3 1.29 4.0 38.6 4.11 0.283 29.2 5.4 4.1 0.76 1.02 6.4 5.29 5.4 1.30 4.1 39.0 4.15 0.146 14.0 4.9 3.9 0.80 1.19 6.1 4.12 5.4 1.30 4.1 39.0 4.15 20 0.215 20.2 5.1 4.0 0.78 1.12 6.2 4.55 5.6 1.32 4.3 39.7 4.24 0.283 28.5 5.2 4.0 0.77 1.09 6.3 4.77 5.7 1.33 4.4 40.0 4.29 0.146 13.6 4.7 3.8 0.81 1.27 6.0 3.70 5.8 1.34 4.5 40.4 4.33 25 0.215 19.6 4.9 3.9 0.80 1.20 6.1 4.08 6.0 1.37 4.6 41.1 4.38 0.283 27.7 5.0 3.9 0.78 1.18 6.2 4.24 6.1 1.38 4.7 41.4 4.42 0.146 13.2 4.4 3.6 0.82 1.34 5.7 3.28 6.1 1.37 4.7 41.4 4.45 30 0.215 19.1 4.6 3.7 0.80 1.29 5.9 3.57 6.3 1.40 4.9 42.1 4.50 0.283 27.0 4.7 3.8 0.81 1.26 6.0 3.73 6.3 1.41 4.9 42.1 4.47 0.146 12.8 4.0 3.3 0.83 1.41 5.4 2.84 35 0.215 18.5 4.3 3.5 0.81 1.36 5.7 3.16 Operation Not Recommended 0.283 26.3 4.4 3.6 0.82 1.33 5.7 3.31 HE LAT C Rev: 03/12/03 B Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. **

PERFORMANCE DATA GCH/V 024B 319 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.190 13.8 6.4 5.1 0.80 1.41 7.8 4.54 6.7 1.43 5.3 37.4 4.69 15 0.284 26.6 6.5 5.2 0.80 1.33 7.8 4.89 7.0 1.46 5.5 38.2 4.79 0.378 44.4 6.6 5.2 0.79 1.29 7.9 5.12 7.2 1.48 5.7 38.7 4.86 0.190 13.4 6.3 5.0 0.79 1.49 7.8 4.23 7.2 1.49 5.7 38.7 4.83 20 0.284 25.7 6.4 5.1 0.80 1.42 7.8 4.51 7.5 1.51 6.0 39.5 4.97 0.378 43.0 6.4 5.1 0.80 1.38 7.8 4.64 7.6 1.53 6.1 39.8 4.97 0.190 13.0 6.1 4.9 0.80 1.58 7.7 3.86 7.7 1.54 6.2 40.0 5.00 25 0.284 25.0 6.3 5.0 0.79 1.52 7.8 4.14 7.9 1.57 6.3 40.5 5.03 0.378 41.8 6.3 5.0 0.79 1.48 7.8 4.26 8.0 1.58 6.4 40.8 5.06 0.190 12.6 5.8 4.7 0.81 1.67 7.5 3.47 8.0 1.59 6.4 40.8 5.03 30 0.284 24.5 6.0 4.9 0.82 1.61 7.6 3.73 8.2 1.61 6.6 41.3 5.09 0.378 41.0 6.1 4.9 0.80 1.57 7.7 3.89 8.2 1.63 6.6 41.3 5.03 0.190 12.2 5.4 4.5 0.83 1.75 7.2 3.09 35 0.284 23.8 5.7 4.6 0.81 1.69 7.4 3.37 Operation Not Recommended 0.378 39.8 5.9 4.7 0.80 1.66 7.6 3.55 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCH/V 030B 401 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.240 10.8 7.3 5.7 0.78 1.64 8.9 4.45 8.0 1.81 6.2 36.5 4.42 15 0.353 19.4 7.4 5.8 0.78 1.57 9.0 4.71 8.2 1.83 6.4 36.9 4.48 0.473 30.2 7.4 5.8 0.78 1.53 8.9 4.84 8.3 1.84 6.5 37.1 4.51 0.240 10.5 7.1 5.6 0.79 1.75 8.9 4.06 8.4 1.85 6.6 37.3 4.54 20 0.353 18.7 7.3 5.7 0.78 1.66 9.0 4.40 8.6 1.86 6.7 37.8 4.62 0.473 29.2 7.3 5.7 0.78 1.62 8.9 4.51 8.7 1.87 6.8 38.0 4.65 0.240 10.3 6.9 5.5 0.80 1.88 8.8 3.67 8.8 1.88 6.9 38.2 4.68 25 0.353 18.3 7.1 5.6 0.79 1.79 8.9 3.97 9.0 1.90 7.1 38.6 4.74 0.473 28.4 7.1 5.7 0.80 1.75 8.9 4.06 9.1 1.91 7.2 38.8 4.76 0.240 9.9 6.6 5.4 0.82 2.00 8.6 3.30 9.2 1.92 7.3 39.0 4.79 30 0.353 17.9 6.8 5.5 0.81 1.91 8.7 3.56 9.4 1.94 7.5 39.4 4.85 0.473 27.7 6.9 5.5 0.80 1.87 8.8 3.69 9.5 1.95 7.6 39.6 4.87 0.240 9.7 6.2 5.2 0.84 2.11 8.3 2.94 35 0.353 17.4 6.4 5.3 0.83 2.04 8.4 3.14 Operation Not Recommended 0.473 26.9 6.6 5.4 0.82 2.00 8.6 3.30 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCH/V 036B 472 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.284 12.3 9.6 7.2 0.75 2.24 11.8 4.29 10.0 2.41 7.6 37.6 4.15 15 0.429 22.1 9.8 7.2 0.73 2.12 11.9 4.62 10.6 2.48 8.1 38.6 4.27 0.567 35.2 9.9 7.3 0.74 2.05 12.0 4.83 10.9 2.52 8.4 39.1 4.33 0.284 11.8 9.3 7.1 0.76 2.38 11.7 3.91 11.0 2.52 8.5 39.3 4.37 20 0.429 21.6 9.6 7.2 0.75 2.26 11.9 4.25 11.6 2.60 9.0 40.4 4.46 0.567 34.0 9.7 7.2 0.74 2.19 11.9 4.43 11.8 2.63 9.2 40.7 4.49 0.284 11.5 8.8 6.9 0.78 2.53 11.3 3.48 11.9 2.65 9.3 40.9 4.49 25 0.429 21.1 9.2 7.1 0.77 2.42 11.6 3.80 12.4 2.72 9.7 41.8 4.56 0.567 33.1 9.4 7.1 0.76 2.35 11.8 4.00 12.6 2.74 9.9 42.1 4.60 0.284 11.3 8.3 6.7 0.81 2.67 11.0 3.11 12.7 2.75 10.0 42.3 4.62 30 0.429 20.6 8.7 6.9 0.79 2.57 11.3 3.39 13.1 2.81 10.3 43.0 4.66 0.567 32.4 8.9 7.0 0.79 2.51 11.4 3.55 13.2 2.84 10.4 43.2 4.65 0.284 10.9 7.6 6.3 0.83 2.81 10.4 2.70 35 0.429 20.1 8.1 6.6 0.81 2.72 10.8 2.98 Operation Not Recommended 0.567 31.4 8.3 6.7 0.81 2.66 11.0 3.12 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCV 041B 543 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.335 6.6 10.1 7.8 0.77 2.28 12.4 4.43 11.0 2.63 8.4 36.8 4.18 15 0.498 15.2 10.2 7.8 0.76 2.19 12.4 4.66 11.4 2.69 8.7 37.4 4.24 0.662 27.8 10.3 7.8 0.76 2.15 12.5 4.79 11.6 2.72 8.9 37.7 4.26 0.335 6.4 9.9 7.8 0.79 2.42 12.3 4.09 11.7 2.74 9.0 37.9 4.27 20 0.498 15.0 10.0 7.8 0.78 2.31 12.3 4.33 12.1 2.79 9.3 38.5 4.34 0.662 26.8 10.1 7.8 0.77 2.26 12.4 4.47 12.3 2.82 9.5 38.8 4.36 0.335 6.3 9.7 7.7 0.79 2.60 12.3 3.73 12.4 2.84 9.6 38.9 4.37 25 0.498 14.5 9.8 7.8 0.80 2.47 12.3 3.97 12.8 2.89 9.9 39.5 4.43 0.662 26.2 9.9 7.8 0.79 2.41 12.3 4.11 12.9 2.91 10.0 39.7 4.43 0.335 6.0 9.3 7.4 0.80 2.77 12.1 3.36 13.0 2.93 10.1 39.8 4.44 30 0.498 14.3 9.6 7.6 0.79 2.65 12.3 3.62 13.3 2.97 10.3 40.3 4.48 0.662 25.6 9.7 7.7 0.79 2.59 12.3 3.75 13.5 2.99 10.5 40.6 4.52 0.335 5.9 8.7 7.1 0.82 2.94 11.6 2.96 35 0.498 14.0 9.1 7.3 0.80 2.83 11.9 3.22 Operation Not Recommended 0.662 24.9 9.3 7.4 0.80 2.77 12.1 3.36 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCH/V 042B 566 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.335 7.2 10.9 8.3 0.76 2.48 13.4 4.40 12.0 2.85 9.2 37.6 4.21 15 0.505 18.6 11.0 8.3 0.75 2.37 13.4 4.64 12.5 2.93 9.6 38.3 4.27 0.694 38.0 11.1 8.3 0.75 2.33 13.4 4.76 12.8 2.98 9.8 38.7 4.30 0.335 7.0 10.7 8.3 0.78 2.65 13.4 4.04 12.9 2.99 9.9 38.9 4.31 20 0.505 18.1 10.9 8.3 0.76 2.51 13.4 4.34 13.4 3.07 10.3 39.6 4.36 0.694 36.8 10.9 8.3 0.76 2.45 13.4 4.45 13.7 3.10 10.6 40.0 4.42 0.335 6.7 10.4 8.1 0.78 2.86 13.3 3.64 13.8 3.12 10.7 40.2 4.42 25 0.505 17.5 10.6 8.3 0.78 2.70 13.3 3.93 14.3 3.20 11.1 40.9 4.47 0.694 35.8 10.7 8.3 0.78 2.62 13.3 4.08 14.5 3.23 11.3 41.2 4.49 0.335 6.6 9.9 7.9 0.80 3.07 13.0 3.22 14.6 3.23 11.4 41.4 4.52 30 0.505 17.3 10.3 8.1 0.79 2.92 13.2 3.53 15.1 3.29 11.8 42.1 4.59 0.694 35.2 10.4 8.2 0.79 2.83 13.2 3.67 15.3 3.32 12.0 42.4 4.61 0.335 6.4 9.2 7.5 0.82 3.25 12.5 2.83 35 0.505 16.8 9.7 7.9 0.81 3.13 12.8 3.10 Operation Not Recommended 0.694 34.2 10.0 8.0 0.80 3.05 13.1 3.28 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCH/V 048B 649 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.379 8.7 12.7 9.6 0.76 3.01 15.7 4.22 13.3 3.03 10.3 37.0 4.39 15 0.568 20.0 12.8 9.7 0.76 2.85 15.7 4.49 14.0 3.11 10.9 37.9 4.50 0.757 36.7 12.9 9.7 0.75 2.78 15.7 4.64 14.3 3.15 11.2 38.3 4.54 0.379 8.5 12.4 9.5 0.77 3.20 15.6 3.88 14.4 3.16 11.2 38.4 4.56 20 0.568 19.6 12.6 9.6 0.76 3.03 15.6 4.16 15.0 3.23 11.8 39.1 4.64 0.757 35.6 12.7 9.6 0.76 2.95 15.7 4.31 15.4 3.26 12.1 39.7 4.72 0.379 8.2 11.9 9.4 0.79 3.41 15.3 3.49 15.5 3.28 12.2 39.8 4.73 25 0.568 19.0 12.3 9.5 0.77 3.24 15.5 3.80 16.1 3.35 12.8 40.6 4.81 0.757 34.6 12.4 9.5 0.77 3.16 15.6 3.92 16.4 3.38 13.0 40.9 4.85 0.379 8.0 11.3 9.1 0.81 3.61 14.9 3.13 16.4 3.38 13.0 40.9 4.85 30 0.568 18.5 11.8 9.3 0.79 3.46 15.3 3.41 16.9 3.44 13.5 41.6 4.91 0.757 33.7 12.0 9.4 0.78 3.38 15.4 3.55 17.2 3.46 13.7 42.0 4.97 0.379 7.8 10.5 8.8 0.84 3.79 14.3 2.77 35 0.568 18.0 11.1 9.1 0.82 3.66 14.8 3.03 Operation Not Recommended 0.757 32.7 11.4 9.2 0.81 3.59 15.0 3.18 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA GCH/V 060B 779 l/s Nominal Airflow Performance capacities shown in EWT C Water Flow l/s WPD kpa TC SC COOLING - EAT 27/19 C HEATING - EAT 20 C Sens/Tot Ratio HR HC 0.474 30.3 15.3 11.3 0.74 3.58 18.9 4.27 16.1 4.11 12.0 37.1 3.92 15 0.713 52.3 15.4 11.6 0.75 3.42 18.8 4.50 17.3 4.23 13.1 38.4 4.09 0.946 79.7 15.5 11.6 0.75 3.34 18.8 4.64 17.8 4.30 13.5 38.9 4.14 0.474 29.3 14.9 11.5 0.77 3.78 18.7 3.94 18.1 4.32 13.8 39.3 4.19 20 0.713 50.9 15.2 11.6 0.76 3.61 18.8 4.21 19.2 4.44 14.8 40.4 4.32 0.946 77.1 15.3 11.6 0.76 3.53 18.8 4.33 19.8 4.50 15.3 41.1 4.40 0.474 28.4 14.5 11.4 0.79 4.04 18.5 3.59 20.0 4.53 15.5 41.3 4.42 25 0.713 49.5 14.8 11.5 0.78 3.85 18.7 3.84 21.0 4.64 16.4 42.3 4.53 0.946 75.2 15.0 11.6 0.77 3.76 18.8 3.99 21.5 4.69 16.8 42.9 4.58 0.474 27.8 13.9 11.2 0.81 4.32 18.2 3.22 21.6 4.71 16.9 43.0 4.59 30 0.713 48.3 14.3 11.4 0.80 4.11 18.4 3.48 22.4 4.79 17.6 43.8 4.68 0.946 73.3 14.5 11.5 0.79 4.01 18.5 3.62 22.8 4.83 18.0 44.3 4.72 0.474 26.9 13.1 10.9 0.83 4.63 17.7 2.83 35 0.713 47.0 13.7 11.2 0.82 4.41 18.1 3.11 Operation Not Recommended 0.946 71.2 14.0 11.3 0.81 4.30 18.3 3.26 HE LAT C Interpolation is permissable, extrapolation is not. All entering air conditions are 27 C DB and 19 C WB in cooling and 20 C DB in heating. All performance data is based upon the lower voltage of dual voltage rated units. See Performance Correction Tables for operating conditions other than those listed above. Data table does not reflect ISO pump or fan corrections. Rev: 03/12/03 B **

PERFORMANCE DATA CORRECTION TABLES Air Flow Correction Table Airflow Heating Cooling % of Nominal Htg Cap Heat of Ext Total Cap Sens Cap Heat of Rej 75% 0.966 1.051 0.939 0.970 0.899 0.953 0.967 81% 0.976 1.037 0.956 0.979 0.924 0.966 0.976 88% 0.985 1.023 0.973 0.987 0.949 0.979 0.985 94% 0.993 1.012 0.987 0.994 0.975 0.990 0.993 100% 1.000 1.000 1.000 1.000 1.000 1.000 1.000 106% 1.006 0.991 1.010 1.005 1.026 1.008 1.005 113% 1.011 0.982 1.020 1.009 1.051 1.016 1.010 119% 1.014 0.975 1.027 1.011 1.077 1.022 1.013 125% 1.017 0.968 1.033 1.013 1.102 1.027 1.016 Rev: 06/12/01 B Entering Air Correction Table Heating Corrections Cooling Corrections Ent Air DB C Htg Cap Heat of Ext Ent Air WB C Sens Clg Cap Multiplier - Entering DB F Total Clg Cap 21 23 25 27 29.5 32 35 Heat of Rej 15 1.026 0.935 1.054 15 0.855 0.810 0.948 1.095 1.190 * * * 0.983 0.880 17 1.016 0.962 1.032 17 0.928 0.681 0.836 0.983 1.095 * * * 0.989 0.939 20 1.000 1.000 1.000 19 1.000 0.552 0.707 0.853 1.000 1.147 * * 1.000 1.000 22 0.984 1.025 0.972 21 1.059 0.052 0.422 0.690 0.853 1.026 1.164 1.328 1.006 1.049 24 0.969 1.050 0.944 23 1.105 0.371 0.664 0.845 1.017 1.207 1.006 1.086 26 0.953 1.072 0.917 25 1.125 0.233 0.586 0.776 0.966 1.155 1.008 1.103 * Sensible capacity equals total capacity Rev: 08/08/02 B **

BLOWER PERFORMANCE DATA Airflow in l/s with dry coil and clean air filter. Model Rated Min Fan External Static Pressure (Pa) l/s l/s Speed 0 25 50 75 100 125 150 175 200 225 250 275 300 325 HI 297 274 255 222 165 H/V 018 236 175 MED 302 288 269 245 222 170 LOW 288 274 255 236 175 HI 378 345 283 241 H/V 024 319 235 MED 439 420 392 359 326 274 222 LOW 378 363 340 321 245 236 HI 505 463 420 378 312 H/V 030 401 305 MED 543 510 467 425 382 316 LOW 514 491 448 411 312 HI 609 585 543 500 453 368 H/V 036 472 355 MED 500 486 463 439 406 340 LOW 467 453 430 411 411 HI 534 517 500 470 431 397 342 V041 543 378 MED 487 474 461 440 406 371 LOW 418 406 397 380 359 HI 694 670 647 618 585 548 505 467 H/V 042 566 425 MED 647 628 604 581 548 519 486 439 LOW 505 500 496 486 467 HI 812 765 713 632 543 H/V 048 649 495 MED 807 769 741 694 609 LOW 784 765 746 732 694 642 590 HI 953 949 935 902 873 854 831 798 760 703 H/V 060 779 590 MED 902 887 864 840 821 793 774 741 703 637 LOW 826 817 802 788 769 741 708 670 604 Gray areas denote ESP where operation is not recommended Rev.: 08/09/02 B Units factory shipped on medium speed. Other speeds require field selection. All airflow is rated at lowest Voltage if unit is dual Voltage rated, i.e. 200V for 200-220V units. All units ARI/ISO/ASHRAE 13256-1 rated on high fan speed. For wet coil performance first calculate the face velocity of the air coil (Face Velocity [mpm] = Airflow [l/s]/1000 / Face Area [m2]). Then for velocities of 61 m per min reduce the static capability by 7.5 Pa, 91 m per min by 20 Pa, 121 m per min by 30 Pa. and 150 m per min by 40 Pa. **

PHYSICAL DATA y Model H/V 018 H/V 024 H/V 030 H/V 036 V041 H/V 042 H/V 048 H/V 060 Compressor (1 each) Recip Recip Recip Recip Recip Recip Recip Scroll Factory R22 Charge Vertical, oz [kg] 26 [0.74] 38 [1.08] 37 [1.05] 42 [1.19] 50 [1.42] 51 [1.45] 66 [1.87] 74 [2.10] Factory R22 Charge Horizontal - oz. [kg] 25 [0.71] 38 [1.08] 37 [1.05] 41 [1.16] 50 [1.42] 51 [1.45] 66 [1.87] 74 [2.10] PSC Fan Motor & Blower Fan Motor Type/Speeds PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 Fan Motor - hp [W] 1/6 [124] 1/4 [187] 3/4 [560] 1/2 [373] 3/4 [560] 3/4 [560] 3/4 [560] 1 [746] Blower Wheel Size (Dia x W) - in. [cm] 8 x 7 [20.3x17.8] 9 x 7 [22.9x17.8] 9 x 7 [22.9x17.8] 9 x 8 [22.9x20.3] 9 x 8 [22.9x20.3] 9 x 8 [22.9x20.3] 10 x 10 [25.4x25.4] 11 x 10 [27.9x25.4] Water Connection Size FPT - American Std Pipe thread - in. [mm] 1/2 [12.7] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 3/4 [19.1] 1 [25.4] 1 [25.4] Horizontal Air Coil Dimensions (H x W) - in. [cm] 16 x 22 [40.6x55.9] 16 x 22 [40.6x55.9] 16 x 22 [40.6x55.9] 20 x 25 [50.8x63.5] - 20 x 25 [50.8x63.5] 20 x 35 [50.8x88.9] 20 x 35 [50.8x88.9] Air Coil Total Face Area - ft2 [m2] 2.44 [0.227] 2.44 [0.227] 2.44 [0.227] 3.47 [0.323] - 3.47 [0.323] 4.86 [0.452] 4.86 [0.452] Air Coil Tube Diam - in. [mm] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] - 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Distance between fins, in. [mm] 0.083 [2.1] 0.083 [2.1] 0.083 [2.1] 0.077 [2.0] - 0.083 [2.1] 0.083 [2.1] 0.083 [2.1] Air Coil Number of rows 2 3 3 2-3 3 3 Filter Standard - 1" [25.4mm] Throwaway - in. [cm] 16 x 25 16 x 25 16 x 25 1-20x28 or 2-20x14-1 - 20x28 or 2-20x14 1-20x24 & 1-20x14 1-20x24 & 1-20x14 [40.6x63.5] [40.6x63.5] [40.6x63.5] [1-50.8x71.1 or 2-50.8x35.6] - [1-50.8x71.1 or 2-50.8x35.6] [1-50.8x61.0 & 1-50.8x35.6] [1-50.8x61.0 & 1-50.8x35.6] Vertical Air Coil Dimensions (H x W) - in. [cm] 20 x 17.25 [50.8x43.8] 20 x 17.25 [50.8x43.8] 20 x 17.25 [50.8x43.8] 24 x 21.75 [61.0x55.2] 20 x 17.25 [50.8x43.8] 24 x 21.75 [61.0x55.2] 24 x 28.25 [61.0x71.8] 24 x 28.25 [61.0x71.8] Air Coil Total Face Area - ft2 [m2] 2.40 [0.223] 2.40 [0.223] 2.40 [0.223] 3.62 [0.337] 2.40 [0.223] 3.62 [0.337] 4.71 [0.438] 4.71 [0.438] Air Coil Tube Diam - in. [mm] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] 3/8 [9.5] Air Coil Distance between fins, in. [mm] 0.083 [2.1] 0.083 [2.1] 0.083 [2.1] 0.077 [2.0] 0.091 [2.3] 0.083 [2.1] 0.083 [2.1] 0.083 [2.1] Air Coil Number of rows 2 3 3 2 4 3 3 3 Filter Standard - 1" [25.4mm] Throwaway - in. [cm] 20 x 20 20 x 20 20 x 20 24 x 24 20 x 20 24 x 24 1-14x24 & 1-18x24 1-14x24 & 1-18x24 [50.8x50.8] [50.8x50.8] [50.8x50.8] [61.0x61.0] [50.8x50.8] [61.0x61.0] [1-35.6x61.0 & 1-45.7x61.0] [1-35.6x61.0 & 1-45.7x61.0] Weight - Operating - lbs. [kg] 181 [82.1] 189 [85.7] 197 [89.4] 203 [92.1] 207 [93.9] 218 [98.9] 263 [119.2] 278 [126.1] Weight - Packaged - lbs. [kg] 186 [84.4] 194 [88.0] 202 [91.6] 209 [94.8] 212 [96.2] 224 [101.6] 270 [119.3] 285 [129.3] Notes: "-" Data not available at time of printing All units have grommet compressor mountings,and 1/2" & 3/4" electrical knockouts. Check serial plate for refrigerant type (R22). Rev.: 07/18/02 B **

HORIZONTAL DIMENSIONAL DATA 2 Service Access Front ASP LEFT RETURN CSP Optional 2 Service Access Left Return 3.3 Supply 3 / 4 Knockout 1 / 2 Knockout Low Voltage 1 / 2 Knockout Legend CAP=Control Access Panel CSP=Compressor Service Panel BSP=Blower Service Panel ASP=Alternate Service Panel 1.1 K J 2 H G F Right Return 3.3 RIGHT RETURN Front CSP 2 Service Access Optional 2 Service Access CAP E D Straight Discharge 3 Back Discharge 0.7 Condensate 3 / 4 FPT 1 A Front-View 0.7 Condensate 3 / 4 FPT Back Discharge Straight Discharge BSP O M N Blower Outlet Air Coil Side C V Front Unit Hanger Detail Model U V W 018-030 43.1 22.2 18.0 036-042 47.1 22.2 18.0 048-060 54.1 26.2 22.0 W C Air Coil Side N Blower Outlet P M BSP P O A U A Left Return Back Discharge N O L N Right Return Back Discharge ASP Blower Outlet M BSP BSP Blower Outlet M CSP Front Left Return Straight Discharge L O Right Return Straight Discharge Front T S Q Air Coil 1.75 Air Coil Q S T C R CSP C ASP R B Left Return Left View - Air Coil Opening Front Front B Right Return Right View - Air Coil Opening Rev.: 08/09/01 B Water Connections Electrical Knockouts Overall Cabinet Discharge Connections Return Connection Horizontal 1 - In 2 - Out H J K duct flange (± 0.10 in) using return air opening Model A B C D E F G 1/2" cond 1/2" cond 3/4" cond L M N O P Q R S T Width Depth Height ** Low Voltage Low Voltage 018-030 in. 20.1 43.1 17.1 15.3 2.4 1.9 2.1 12.1 9.1 6.1 2.6 13.3 9.9 4.1 1.3 23.0 15.0 1.1 1.0 cm. 51.1 109.5 43.4 38.9 6.1 4.9 5.3 30.8 23.2 15.6 6.6 33.8 25.1 10.5 3.3 58.4 38.1 2.8 2.5 036-042 in. 20.1 47.1 21.1 18.8 2.2 4.7 1.2 16.1 13.1 10.1 2.5 16.1 11.0 3.0 2.5 25.9 19.0 1.1 1.0 cm. 51.1 119.6 53.6 47.6 5.5 11.9 3.0 41.0 33.3 25.7 6.3 40.9 27.9 7.7 6.4 65.8 48.3 2.8 2.5 048 in. 24.1 54.1 21.1 19.4 5.9 4.3 2.3 16.1 13.1 10.1 3.7 16.1 13.7 4.1 1.3 35.9 19.0 1.1 1.0 cm. 61.2 137.4 53.6 49.2 14.9 11.0 5.8 41.0 33.3 25.7 9.5 41.0 34.8 10.3 3.2 91.2 48.3 2.8 2.5 060 in. 24.1 54.1 21.1 19.4 5.9 4.3 2.3 16.1 13.1 10.1 1.7 18.1 13.7 4.1 1.3 35.9 19.0 1.1 1.0 cm. 61.2 137.4 53.6 49.2 14.9 11.0 5.8 41.0 33.3 25.7 4.4 46.0 34.8 10.3 3.2 91.2 48.3 2.8 2.5 Condensate is 3/4" FPT copper. Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection. Hanger kit is factory installed Verify high static option discharge connection dimensions with ClimateMaster Supply Supply Height Supply Depth Return Depth Return Height Rev.: 08/09/01 B

VERTICAL DIMENSIONAL DATA Field Installed Discharge Flange Standard Filter Bracket Access Panels Legend CAP=Control Access Panel CSP=Compressor Service Panel BSP=Blower Service Panel ASP=Alternate Service Panel P N N B P Air Coil BSP ASP O Q Front Air Coil Side Air Coil Side Front O M A CSP CAP 2 (61cm) Service Access * Left Rtn (Right Rtn Opposite Side) Top View-Right Return Top View-Left Return U R S U S R 2 (61cm) Service Isometric View 1.00 [25.4 mm] Air Coil Air Coil T T BSP Front C CSP Right Return Right View - Air Coil Opening Back Back C CSP Left Return Left View - Air Coil Opening Front Supply 3/4 (19.1 mm) HV Knockout Low Voltage 1/2 (12.7 mm) LV Knockout Low Voltage 1/2 (12.7 mm) LV Knockout CAP Condensate 3/4 (19.1 mm) FPT L 3 F CSP J K I H 1 D E Front-View * Note: Shaded areas are recommended service areas, not required. 2 G Rev.: 05/07/02 B Vertical Overall Cabinet Water Connections Electrical Knockouts Discharge Connection Return Connection Upflow 1 2 3 Water J K L duct flange installed (±0.10 in) using return air opening Model A B C D E F G H I FPT 1/2" cond 1/2" cond 3/4" cond M N O P Q R S T U Width Depth Height In Out Condensate Size Low Low Supply Return Voltage Voltage Supply Width Depth Depth Height 018-030 in. 21.5 21.5 39.0 1.8 3.8 15.2 3.6 8.1 2.3 3/4" 4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.2 0.7 cm. 54.6 54.6 99.1 4.5 9.7 38.6 9.1 20.6 5.8 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 51.3 1.9 036 & 042 in. 21.5 26.0 44.0 2.0 3.7 16.2 2.6 10.4 2.3 3/4" 4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.1 2.3 22.8 24.2 0.7 cm. 54.6 66.0 111.8 5.1 9.4 41.1 6.6 26.4 5.8 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.1 5.8 57.9 61.4 1.9 041 in. 21.5 21.5 39.0 1.7 3.6 16.4 2.6 8.1 2.3 3/4" 4.1 7.1 10.1 6.4 3.8 14.0 14.0 5.3 2.3 18.3 20.2 0.7 cm. 54.6 54.6 99.1 4.4 9.1 41.7 6.6 20.6 5.8 1.9 10.5 18.1 25.7 16.1 9.5 35.6 35.6 13.6 5.8 46.5 51.3 1.9 048-060 in. 24.0 32.5 46.0 1.8 5.9 16.7 2.3 10.1 2.3 1" 4.1 7.1 10.1 6.9 7.3 16.0 18.0 5.1 2.3 29.3 24.2 0.7 cm. 61.0 82.6 116.8 4.5 14.9 42.4 5.8 25.7 5.8 2.5 10.5 18.1 25.7 17.4 18.4 40.6 45.7 13.1 5.8 74.4 61.4 1.9 Rev.: 05/13/02 B Condensate is 3/4" ( 19.1 mm) FPT Filter bracket extending from unit 2.5" (6.4 cm). This bracket should be removed when connecting return duct. Discharge flange field installed **

UNIT ELECTRICAL DATA Voltage Rated Voltage Compressor Fan Total Min Max Model Code Voltage Min/Max Motor Unit Circ Fuse/ Qty RLA LRA FLA FLA Amp HACR V/H018 V 220-240/50/1 197/254 1 8.1 44.0 0.86 8.9 11.0 15 V/H024 V 220-240/50/1 197/254 1 9.1 55.0 1.30 10.4 12.7 20 U 380-420/50/3 342/462 1 3.5 25.0 0.76 4.2 5.1 15 V/H030 V 220-240/50/1 197/254 1 10.0 58.0 2.70 12.7 15.2 25 U 380-420/50/3 342/462 1 3.6 28.0 1.70 5.3 6.2 15 V/H036 V 220-240/50/1 197/254 1 14.4 83.0 2.00 16.4 20.0 30 U 380-420/50/3 342/462 1 4.9 33.0 1.24 6.1 7.4 15 V041 U 380-420/50/3 342/462 1 4.3 40.0 1.70 6.0 7.1 15 V/H042 U 380-420/50/3 342/462 1 5.3 42.0 1.70 7.0 8.3 15 V/H048 U 380-420/50/3 342/462 1 5.7 42.0 1.80 7.5 8.9 15 V/H060 U 380-420/50/3 342/462 1 7.4 59.6 2.50 9.9 11.8 15 HACR circuit breaker in USA only All fuses Class RK-5 Rev:. 06/22/02 B **

TYPICAL WIRING DIAGRAM SINGLE PHASE WIRING DIAGRAM GC UNITS WITH CXM CONTROLLER GC, GR, GSH/V006-070 Commercial with CXM 208-230/60/1, 265/60/1 & 220-240/50/1 96B0006N01 Rev H 6/8/01 **

TYPICAL WIRING DIAGRAM THREE PHASE WIRING DIAGRAM GC UNITS WITH CXM CONTROLLER (460/575 Volt) GC, GR, GSH/V024-070 Commercial with CXM 460/60/3, 575/60/3, & 380-420/60/3 96B0008N01 Rev. F 5/7/01 **

TYPICAL WIRING DIAGRAM SINGLE PHASE WIRING DIAGRAM GC UNITS WITH DXM CONTROLLER ** GC, GR, GSH/V006-070 Commercial with DXM 208-230/60/1, 265/60/1 & 220-240/50/1 96B0006N02 Rev. F 6/8/01

TYPICAL WIRING DIAGRAM THREE PHASE WIRING DIAGRAM GC UNITS WITH DXM CONTROLLER (460/575 volt) ** GC, GR, GSH/V024-070 Commercial with DXM 460/60/3, 575/60/3, & 380-420/60/3 96B0008N02 Rev. E 5/7/01

GENESIS COMPACT (GC) SERIES ENGINING GUIDE SPECIFICATIONS Revision: 08/08/02 B General Furnish and install ClimateMaster Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. Horizontal/Vertical Water Source Heat Pumps: Units shall be supplied completely factory built and capable of operation with an entering water temperature range from 60 to 95 F (15.6 to 35.0 C) as standard. Equivalent units from other manufacturers can be proposed provided approval to bid is given 10 days prior to bid closing. All equipment listed in this section must be rated and certified in accordance with ARI/ISO/ASHRAE, NRTL, CSA or optional CE Mark. The units shall have ARI/ISO, NRTL, CSA or optional CE Mark labels. All units shall be factory run tested under normal operating conditions at nominal water flow rates. This testing shall generate a report card to be shipped with each unit stating performance in both heating and cooling modes. Serial numbers will be recorded by factory and furnished to contractor for ease of unit warranty status. Units tested without water flow ARE NOT acceptable. Basic Construction Horizontal Units shall have one of the following air flow arrangements: Right-Discharge/Left-Inlet; Left-Discharge/Right-Inlet; Back-Discharge/Left-Inlet; or Back-Discharge/Right-Inlet as shown on the plans. Units must have the ability to be field convertible from side to back or back to side discharge with no additional parts or unit structure modification. Units will have factory installed hanger brackets and isolation grommets. Vertical Units shall have one of the following air flow arrangements: Right-Return/Top-Discharge or Left-Return/Top-Discharge as shown on the plans. Units will have factory-installed internal condensate trap. If units with these arrangements ARE NOT used, the contractor is responsible for any extra costs incurred by other trades. All units must have a minimum of two access panels for serviceability of compressor compartment. If other arrangements make servicing difficult, the contractor must provide access panels and clear routes to ease service. Architect must approve any changes in layout. The horizontal heat pumps shall be fabricated from heavy gauge galvanized sheet metal. All interior surfaces shall be lined with 1/2 inch thick (12mm), 1-1/2 lb/ft3 (24kg/m3) density acoustic type glass fiber insulation. All fiberglass shall be coated and have exposed edges tucked under flanges to prevent the introduction of glass fibers into the air stream. All insulation must meet NFPA 90A. The vertical heat pumps shall be fabricated from heavy gauge galvanized sheet metal. All interior surfaces shall be lined with 1/2 inch thick (12mm), 1-1/2 lb/ ft3 (24kg/m3) density acoustic type glass fiber insulation. All fiberglass shall be coated and have exposed edges tucked under flanges to prevent the introduction of glass fibers into the air stream. All insulation must meet NFPA 90A. All vertical heat pumps shall have a powder coat paint finish. The color shall be polar ice. Option: Mute package shall consist of sound attenuating materials that are strategically applied to the cabinet, and will consist of 1" (25.4mm) fiberglass insulation that is specifically selected to focus on Noise Reduction at the lower 125 and 250 Hz frequencies. All surfaces that normally have 0.5" (12.7mm) insulation would be substituted the noise dampening 1" (25.4mm) insulation. All units must have an insulated panel separating the fan compartment from the compressor compartment. Units with the compressor in the air stream ARE NOT acceptable. Units shall have a factory installed 1 inch wide filter bracket for filter removal from either side. Units shall have a 1 inch (25.4mm) thick throwaway type glass fiber filter. The contractor shall purchase one spare set of filters and replace factory shipped filters on completion of start-up. Filters shall be standard sizes. If units utilize non-standard filter sizes then the contractor shall provide 12 spare filters for each unit. Option: Contractor shall install 2 inch (50.8mm) filter brackets and 2 inch (50.8mm) glass fiber throwaway filters on all units. Cabinets shall have separate openings and knockouts for entrance of line voltage and low voltage control wiring. Supply and return water connections shall be copper FPT fittings. All water connections and electrical knockouts must be in the compressor compartment corner post as to not interfere with the serviceability of unit. Contractor shall be responsible for any extra costs involved in the installation of units that do not have this feature. Contractor must ensure that units can be easily removed for servicing and coordinate locations of electrical conduit and lights with the electrical contractor. Fan and Motor Assembly Units rated 60,000 BTUH and under shall have a direct-drive centrifugal fan. The fan motor shall be 3-speed (2 speed 575V), permanently lubricated, PSC type with internal thermal overload protection. Blower shall have inlet rings to allow removal of wheel and motor from one side without removing housing. Units supplied without permanently lubricated motors must provide external oilers for easy service. The fan motor shall be isolated from the fan housing by torsionally flexible isolation grommets. The fan and motor assembly must be capable of overcoming the external static pressures as shown on the schedule. CFM/Static pressure rating of the unit shall be based on a dry coil and a clean filter in place. Option: High static motors available for sizes 018 through 060 (except GCV041). Refrigerant Circuit Units shall have a sealed refrigerant circuit including a high efficient rotary or reciprocating compressor designed for heat pump operation, a capillary tube assembly for refrigerant metering, an enhanced aluminum lanced fin and rifled copper tube refrigerant to air heat exchanger, a reversing valve, a coaxial (tube in tube) refrigerant to water heat exchanger, and safety controls including a high pressure switch, a low pressure sensor, and a low water temperature sensor. **

GENESIS COMPACT (GC) SERIES ENGINING GUIDE SPECIFICATIONS (cont.) Revision: 06/03/02 B Access fittings shall be factory installed on high and low pressure refrigerant lines to facilitate field service. Activation of any safety device shall prevent compressor operation via a lockout device. The lockout shall be reset at the thermostat or at the contractor supplied disconnect switch. Units which may be reset only at the disconnect switch only SHALL NOT be acceptable. Hermetic reciprocating compressors shall be internally sprung. The compressor will be mounted on external computer selected isolating grommets. The external grommets will be secured to a heavy gauge compressor plate that has rubber grommet isolation from the cabinet base, which provides multiple levels of isolation. Compressor shall have thermal overload protection and be located in an insulated compartment away from air stream to minimize sound transmission. Refrigerant to air heat exchangers shall utilize enhanced lanced aluminum fins and rifled copper tube construction rated to withstand 450 PSIG (3108 kpa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 450 PSIG (3108 kpa) working refrigerant pressure and 450 PSIG (3108 kpa) working water pressure. Plate to plate heat exchangers ARE NOT acceptable. Reversing valves shall be four-way solenoid activated refrigerant valves which shall fail to heating operation should the solenoid fail to function. If the reversing valve solenoid fails to cooling, a low temperature thermostat must be provided to prevent over-cooling an already cold room. Option: The unit will be supplied with cupro-nickel coaxial water to refrigerant heat exchangers. Drain Pan The drain pan shall be constructed to inhibit corrosion and fully insulated. Drain outlet shall be located on pan as to allow complete and unobstructed drainage of condensate. The unit as standard will be supplied with solid-state electronic condensate overflow protection. Mechanical float switches WILL NOT be accepted. Electrical A control box shall be located within the unit compressor compartment and shall contain a 50VA transformer, 24 Volt activated, 2 or 3 pole compressor contactor, terminal block for thermostat wiring and solid-state controller for complete unit operation. Electro-mechanical operation WILL NOT be accepted. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 Volt and provide heating or cooling as required by the remote thermostat/sensor. Option: CE Mark Construction: To include power connection block, compressor grounding, fully insulated terminals and CE listed electrical components. Solid-State Control System Units shall have a solid-state control system (CXM). The control shall interface with a heat pump (Y,O) wall thermostat, mechanical or electronic. The control system microprocessor board shall be specifically designed to protect against building electrical system noise contamination, EMI, and RFI interference. The control system shall have the following features: a. Anti-short cycle time delay on compressor operation, time delay shall be 5 minutes minimum. b. Random start on power up mode. c. Low voltage protection. d High voltage protection. e. Unit shutdown on high or low refrigerant pressures. f. Unit shutdown on low water temperature. g. Water coil low temperature cutout (selectable for water or anti-freeze). h. Condensate overflow shutdown. i. Option to reset unit at thermostat or disconnect. Fault type shall be retained in memory if reset at thermostat. j. Automatic intelligent reset. Unit shall automatically reset 5 minutes after trip if the fault has cleared. Should a fault re-occur 3 times sequentially then permanent lockout will occur. k. Ability to defeat time delays for servicing. l. Light emitting diodes (LED) to indicate high pressure, low pressure, low voltage, high voltage, low water temperature cut-out, condensate overflow and control status. m. The low pressure switch SHALL NOT be monitored for the first 120 seconds after a compressor start command to prevent nuisance safety trips. n. Remote fault type indication at thermostat. o. Selectable 24V or pilot duty dry contact alarm output. p. 24V output to cycle a motorized water valve with compressor contactor. Option: Enhanced control features (DXM) Control shall have all the features of the CXM control with the following additional features: a. A removable thermostat connector. b. Random start on return from night setback. c. Minimized reversing valve operation for extended life and quiet operation. d. Night setback control from low temperature thermostat, with 2-hour override initiated by a momentary signal from the thermostat. e. Dry contact night setback output for digital night setback thermostats. f. Ability to work with heat/cool (Y, W) thermostats. **

GENESIS COMPACT (GC) SERIES ENGINING GUIDE SPECIFICATIONS (cont.) Revision: 06/03/02 B ** g. Ability to work with heat pump thermostats using O or B reversing valve control. h. Single grounded wire to initiate night setback, or emergency shutdown. i. Boilerless system control can switch automatically to electric heat at low loop water temperature. j. Control board shall allow up to 3 units to be operated from one thermostat without any auxiliary controls. k. A relay to operate an external damper. The control to be such that the damper WILL NOT open until 30 minutes after the unit comes back from unoccupied mode. l. Fan speed selection at thermostat. m. A relay to restart a central pump or control a 24V motorized water valve. n. Intelligent fan speed selection based upon thermostat demand and/or dehumidistat signal. Option: LonWorks Control System Units shall have all the features listed above and the control board will be supplied with a LonWorks interface board. This will permit all units to be daisy chain connected by a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: a. space temperature. b. leaving water temperature. c. discharge air temperature. d. command of space temperature setpoint. e. cooling status. f. heating status. g. fan ON/AUTO position of space thermostat as specified above. h. unoccupied/occupied command. i. compressor shutdown (load shedding) command. j. emergency shutdown command. k. cooling command. l. heating command. m. fan ON/AUTO command. Field Installed Options Hose Kits All units 120,000 BTUH (35 ) and below shall be connected with hoses. The hoses shall be 2 feet (0.6m) long, braided stainless steel; fire rated hoses complete with adapters. Only fire rated hoses will be accepted. Thermostats Electromechanical Thermostats Thermostats shall be single-stage manual change-over with HEAT-OFF-COOL system switch and fan ON-AUTO switch. Electronic Thermostats Thermostat shall be single-stage, manual changeover with HEAT-OFF-COOL system switch and fan ON-AUTO switch. Thermostat shall have a LCD display with temperature and setpoint indication selectable for F or C. Thermostat shall only require 4 wires for connection. Thermostat shall be single-stage, manual or automatic changeover with HEAT-OFF-COOL-AUTO system settings and fan ON-AUTO settings. Thermostat shall have a back-lit LCD display with temperature, setpoints, mode, and status indication. The temperature indication shall be selectable for F or C. A System Test feature shall be provided to simplify troubleshooting. The thermostat shall provide permanent memory of setpoints without batteries. A fault LED shall be provided. Thermostat shall provide optional extended end of cycle fan operation, outdoor air temperature display, heating setpoint range limit, cooling setpoint range limit, and temperature display offset. Thermostat shall be multi-stage (3H/2C), manual or automatic change over with HEAT-OFF-COOL-AUTO system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, set-points, mode, and status indication. The temperature indication shall be selectable for F or C. A System Test feature shall be provided to simplify troubleshooting. The thermostat shall provide permanent memory of setpoints without batteries. A fault LED shall be provided. Thermostat shall provide optional extended end of cycle fan operation, heating setpoint range limit, cooling setpoint range limit, temperature display offset, temperature display disable, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall provide capability to average from 1 to 9 remote sensors. Thermostat shall switch to selectable unoccupied setpoints upon signal from DXM control within unit. The thermostat shall revert to occupied setpoints when the Override key is pressed. Thermostat shall be 7 day programmable, multi-stage (3H/2C), manual or automatic change over with HEAT-OFF-COOL-AUTO system settings and fan ON- AUTO settings. Thermostat shall have an LCD display with temperature, set-points, mode, and status indication. The temperature indication shall be selectable for F or C. A System Test feature shall be provided to simplify troubleshooting. The thermostat shall provide permanent memory of setpoints and program without batteries. A fault LED shall be provided. Thermostat shall provide optional extended end of cycle fan operation, heating setpoint range limit, cooling setpoint range limit, temperature display offset, temperature display disable, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall provide capability to average from 1 to 9 remote sensors.