GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Similar documents
PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not re

2 / These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

NIDS Dust sensor ED-N-DS-1408

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

Evaluation Board Information

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Piezoelectronic Buzzers

LASER DIODE NX7637BF-AA

Mounting Instruction

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Technical Data Sheet 5mm Infrared LED, T-1

Applications PL- N Series Lens Type Sensor Type Serial Number

Technical Data Sheet 3mm Phototransistor T-1

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Reverse Package Infrared LED IR25-21C/TR8

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

Technical Data Sheet 1.6mm Side Looking Phototransistor

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

FEBL8511_REFBOARD_Manual-01 ML FC. REFERENCE BOARD Manual for UV Sensor (QFN)

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

1Hz,16Hz, S2 S3 S4 S5 S6 S7 S8 ALARM REGISTER COMPARATOR WEEK SECONDS MINUTES HOURS DAYS MONTHS YEARS /12 1 /24 1 /7 /28-1 /31

Surface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide

Technical Data Sheet 5mm Phototransistor T-1

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

Technical Data Sheet 1.5mm Side Face Infrared LED

onlinecomponents.com

SMT450. High Performance TOP LED

EVERLIGHT ELECTRONICS CO.,LTD.

K-Band Doppler Sensor Module

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Instruments Div. Rev.1 Sensing Module Approval Check Drawer Rev.2 Rev.3 RHI-112A

Smoke Detector Demo Reference Solution

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

HULME MARTIN HEAT SEALERS

Premier External TD. Installation Manual INS352-3

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Fortimo LED Line High Flux Module

Fortimo LED Line Gen2 Module

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

Features. Figure 1. Recommended Application

HOA6480 Series Barcode Sensor Infrared Products

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Laser Particle Sensor Module PM2009

Operating Instructions

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

Specification MBT801-S

Technical Data Sheet Opto Interrupter ITR

Installation Manual. Premier IXP-W INS538

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Government of India Ministry of Environment and Forests

Installation Manual Premier Elite IXP-W

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

HULME MARTIN HEAT SEALERS

Preliminary specification

Pyroelectric Infrared Sensors

Wideband Optical Couplers

The UAE RoHS regulation covers all EEE (Electrical and Electronic Equipment) as detailed in Table 1.

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Pyroelectric Infrared Sensors

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

ULTRA FAST RECITIFIERS

HOA0880-T51. Representative photograph, actual product appearance may vary.

Optical Sensors. ROHM Semiconductor USA, LLC 1

E-Waste Management. Existing Scenario

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Manual DRUM-HEATER DH27

FIS30XXseries Gas sensor module SPECIFICATIONS

Use & Care Manual Contemporary Electric Fires

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Record of Amendments. Version Date Amendment Section/page affected

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

Features. Applications

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Use & Care Manual Inset Electric Fires

HEP Tech Co., Ltd. Company Profile

PQS performance specification

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Smart BUS (S-BUS) Home Automation System Simplified Specification

Jacket Heater. Sep Jacket Heater 1

ETH1000-MKII. User manual

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Installation Manual Premier Elite Orbit QD/DT INS483-2

RECOMMENDABLE CONDITION OF SOLDERING

Be Green and Innovative by. Life of the Earth for the Next Generation

Transcription:

GPY00AU0F Compact Optical Dust Sensor Description GPY00AU0F is a dust sensor by optical sensing system. An infrared emitting diode (IRED) and an phototransistor are diagonally arranged into this device. It detects the reflected light of dust in air. Especially, it is effective to detect very fine particle like the cigarette smoke. In addition it can distinguish smoke from house dust by pulse pattern of output voltage. Compliance. Compliant with RoHS directive (00/95/EC) Applications. Detecting of dust in the air.. Example: Air purifier, Air conditioner, Air monitor Features. Compact, thin package (46.0 0.0 7.6 mm). Low consumption current (Icc: MAX. 0 ma). The presence of dust can be detected by the photometry of only one pulse 4. Enable to distinguish smoke from house dust 5. Lead-free and RoHS directive compliant Notice The content of data sheet is subject to change without prior notice. In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Date Dec.. 006 SHARP Corporation

Internal schematic Dust through hole Dust or Smoke particle IRED PD Amplifier Circuit 6 5 4 5 6 V-LED LED-GND LED S-GND V O V CC Rs (For sensitivity adjustment) 4 case Outline Dimensions (Unit : mm) 46.0.0 (.8) Marking portion 0.0 4. 0.0 4.0 (9.) (0.7) 4. 7.8.9.8 φ9 ± 0.5 Dust through hole.0.0 7.6 + 0. 0.5 Connector: S6B-ZR-SM4A-TF by JST Mfg. Co., Ltd. () (4.8) 8..8 R 6.4 () R Terminal configuration V-LED LED-GND LED 4 S-GND 5 Vo 6 Vcc R () () R () φ8 ± 0.5 Dust through hole Hole for sensitivity adjustment of variable resistor * Unspecified tolerance : ± 0. mm. The dimensions in parenthesis are shown for reference. Product mass : approx. 6 g

Marking information Date code GPY0 0 F : Die stamp marking : Ink stamp marking Date code ( digit) st digit nd digit Year of production Month of production A.D. Mark Month Mark 000 0 00 00 00 4 4 004 4 5 5 005 5 6 6 006 6 7 7 007 7 8 8 008 8 9 9 009 9 0 X 00 0 Y : : Z repeats in a 0 year cycle Country of origin Philippines

Absolute Maximum Ratings * Parameter Symbol Rating Unit Supply voltage V CC 0. to +7 V Input terminal voltage VLED 0. to V CC V Operating temperature Topr 0 to +65 C Soldering temperature T sol 0 to +80 C * Open drain drive input Electro-optical Characteristics (Ta=5 C) (Ta=5 C, VCC=5V) Parameter Sensitivity Output voltage at no dust Output voltage range LED terminal current Consumption current Symbol K V OC V OH I LED I CC Conditions * * * * * * * RL =4.7kΩ * LED terminal voltage = 0 * RL = MIN. 0.5 0.4 TYP. 0.5 0.9 0 MAX. 0.65.5 0 0 Unit V/(0.mg/m ) V V ma ma * Sensitivity is specified by the amount of output voltage change when dust density changes by 0. mg/m. And the dust density for detection is a value of the density of cigarette (MILD SEVEN ) smoke measured by the digital dust monitor (P-5L: manufactured by SHIBATA SCIENTIFIC TECHNOLOGY LTD.). * Input condition is shown in Fig. * Output sampling timing is shown in Fig. Recommended input condition for LED input terminal Parameter Pulse Cycle Pulse Width Operating Supply voltage Symbol T PW VCC Value 0 ± 0. ± 0.0 5 ± 0.5 Unit ms ms V 4

Fig. Input Condition for LED Input Terminal Pulse-driven wave form GPY00AU0F I LED + R=50Ω C=0μF V CC T=0ms PW=0.ms Fig. Sampling Timing of Output Pulse ON I LED OFF Output pulse 0.8ms Sampling Fig. Output Voltage vs. Dust Density 4 Output voltage (V) 0 0 0. 0.4 0.6 0.8 Dust density (mg/m ) Remarks : Please be aware that all data in the graph are just for reference and are not for guarantee. 5

Notes Connection of case and GND Case material use conductive resin as cover case {printed model No.} and metal {test terminal side} as bottom cover. The metal case connects with GND in sensor. Cleaning Please don t do cleaning, because there is a case that this device is not satisfied with its characteristics by cleaning. Pulse input range Please subject to recommendation as regard input condition for LED in order to keep reliability. 4 Dust adhesion There is a case that this product does not detect the dust density correctly, since the dust adhered to the inside of the dust through hole may project into the detecting space which consist of emitter and detector light axis. Please take the structure and mechanism of the equipment into consideration to avoid the influence of adhered dust. And when the dust is adhered, please consider the maintenance such as vacuuming or blowing off the dust by air. In addition, please pay attention to structure and placing location of the application to avoid any adhesive particle like oil, etc. to gets into the device. If it sticks to optical part, malfunction may occur. 5 Light output In circuit designing, make allowance for the degradation of the light emitting diode output that results from long continuous operation. (50% degradation/5 years) 6 Sensitivity adjustment VR VR for sensitivity adjustment is set up at shipping from sharp. Please do not touch the VR or Electro-optical characteristics specified on the specification will be invalid. 7 Resolution Please do not disassemble the device such as removing tapping screw and so on. Even if the device is reassembled, it may not satisfy the specification. 8 Application to fire alarm Please do not use this device for a fire alarm application. When using this device to application other than air purifying and equipment with air purifying function, please inform us before usage. 9 Noise influence If the sensor is located close to noise generator (ex. Electric dust collector, etc. ), the sensor output may be affected by leaded noise. On top of that noise from power supply line also may affect the sensor output. When desinging the system, please consider the effect from noise. 0 Vibration influence The sensor may change its value under mechanical oscillation. Before usage, please make sure that the device works normally in the application. Incident light influence There is a case that the sensor output may be affected when outer-light comes through dust through hole on printed side. In order to avoid any influence from outer-light, please locate the printed side of sensor facing to inside of the application. When inside of the sensor is moisturized, this product does not keep its proper function. Please design the application so that moisturization of the sensor does not happen. 6

Presence of ODC etc. This product shall not contain the following materials. And they are not used in the production process for this product. Regulation substances : CFCs, Halon, Carbon tetrachloride,..-trichloroethane (Methylchloroform) Specific brominated flame retardants such as the PBB and PBDE are not used in this product at all. This product shall not contain the following materials banned in the RoHS Directive (00/95/EC). Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB), Polybrominated diphenyl ethers (PBDE). 7

Packing Specification Pad Product trays (5 trays/case) Connector Product (B) Packing case Packing tape Tray (A) (C) Quantity Model number Inspection date PACKING METHOD. Each tray holds 50 pieces. Packing methods are shown in (A).. Each box holds 5 trays. Pads are added to top (B).. The box is sealed with packing tape. (C) shows the location of the Model number, Quantity, and Inspection date. 4. Weight is approximately 5.6 kg 8

Important Notices The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. with equipment that requires higher reliability such as: --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc. ) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. (iii) SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: --- Space applications --- Telecommunication equipment [trunk lines] --- Nuclear power control equipment --- Medical and other life support equipment (e.g., scuba). Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment [terminal] --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Law of Japan, it is necessary to obtain approval to export such SHARP devices. This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. Contact and consult with a SHARP representative if there are any questions about the contents of this publication. eastlong@6.com 9