Special Topics on Residential HVAC

Similar documents
Practical and Effective Approaches to Residential Ventilation for Production Builders

Time-Based Scheduling of Residential Ventilation

Residential Heating and Cooling Loads

Unvented Roof Summary Article

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

In 1986, Pulte Homes in Tucson was

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Dehumidification: Energy Efficiency Comparisons

Otherwise, you can continue reading the file on the following pages.

Air Change, Ventilation, and Dehumidification for Multi-family Buildings

On Balance: Heat Rejection Control a Packaged Solution

announcements 4/10/08

Building Science Principles for Managing Moisture in Tight Buildings

Free cooling on RTAF Chiller. Integrated option

Heating and Hot Water

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

Evaporative Cooling in a Hot-Dry Climate

Promoting quality installation of central AC (and heat pump) systems

MBPA Home Performance FIELD DATA COLLECTION FORM

Electric Heat Inspection Form Revised September 2012

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

Southwest Air Conditioning

R4 Ventures LLC White Paper

Continuous Commissioning: A Valuable Partner to Retrofit Projects

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

Basic Building Science insights for Spray Foam, HVAC and Moisture

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Air Distribution Fan and Outside Air Damper Recycling Control

Published by the California Building Performance Contractors Association

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

ENERGY STAR Qualified Homes

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

The Housing Assistance Council is a national nonprofit organization that helps build homes and communities

HVAC for Raters & Inspectors

Superheat charging curves for technicians

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Ventilation for New Low-Rise Residential Buildings July 20, 2015

EnergyMeasure HOME DATA COLLECTION FORM

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

The Ed Roberts Campus Berkeley, CA

Home Energy Savings Program. Wyoming HVAC Trade Ally Manual

Data not Dogma. John Proctor July 30, 2014

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

EXPANSION VALVES. See Red Dot Catalog Also. * 2 ton valves - all other valves are 1 1/2 ton (1) Includes M1 Adapter 71R8050 EX02280

Data driven insights from the nation s deepest ever customer energy research

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

MEASURED PERFORMANCE DATA FOR

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

LEASEHOLD YEARLY PROPERTY SCHEDULE

Suggested Retail Price: $300

INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE

Supplement A- Improving Forced Air Heating Systems

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

Farm Energy Audit Workshop

Equipment Specifications and Required Information Quantity Rebate

Food Control Plans or National Programmes Cold Hold Records 2019

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

MASTER PLAN KICK-OFF Open House #1A, April 28, 2015

2009 Washington State Energy Code Residential Sections

Technical Development Program

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Oct. 19, 2017

Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers

G.W. Berkheimer Technical Classes For

Equipment ATA 12 April 2016

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

HVAC Basics RESIDENTIAL AIR CONDITIONING

SELECTED TOPICS IN HIGH RISE MECHANICAL DESIGN

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

CROWN YEARLY PROPERTY SCHEDULE

Auburn University Basketball Arena:

DUCT LEAKAGE (Page 1 of 3)

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Nov. 2, 2017

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

2016 Title 24 HVAC Topics. June 4, 2013

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

HVAC Equipment Access Equipment Location

Refrigeration and Boil Off Compression Systems for NGL Export Facilities

wattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)

Asparagus Response to Water and Nitrogen

Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011

USING THE P-T CARD AS A SERVICE TOOL

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid

RESNET HERS Rater Sample Test Questions 2

Heat Pumps and Public Swimming Pools, a Perfect Match

INEEL (1500) [45] 5.6 C 217 mm 60. Precipitation (mm) Temperature (oc) Month

RESNET ANNUAL CONFERENCE FEBRUARY 17, ENERGY STAR for Homes: The Road Ahead

Inspection Checklist Mechanical Rough in

FirstEnergy Program Overview

Transcription:

Special Topics on Residential HVAC by Armin Rudd USDOE Building America Program for EEBA Conference 2002 Phoenix, Arizona 10 October 2002 Page 1 of 25

Two Main Topics: 1. Cyclical trade-offs between building envelope improvements, reduced system size, and more efficient systems. 2. If I could change two things! Page 2 of 25

Climate Specific Design Solutions buildingscience.com Page 3 of 25

Trade-offs Better Envelopes Allow for reduced cooling system size Decrease energy consumption Increase occupant comfort Make overall performance more predictable Improve the more permanent features of a home which has longer-term sustainability benefits to society Page 4 of 25

Trade-offs Reduced cooling system size Helps pay for a better envelope Avoids cooling system short-cycling which improves moisture removal allows the system to operate at higher average efficiency Page 5 of 25

Trade-offs More efficient systems Are most cost effective when the load is high this is in conflict with our premise to first reduce loads through improved envelopes High efficiency cooling systems generally have a higher evaporator coil temperature which reduces moisture control this can be changed with effective control of ECM air handlers High efficiency heating systems are generally also sealed combustion which is also good for health and safety Page 6 of 25

Sealed combustion furnace with ECM air handler and special thermostat buildingscience.com Page 7 of 25 Building Science Corporation

Electronically Commutated Motor (ECM) closeup buildingscience.com Page 8 of 25 Building Science Corporation

Trade-offs Let s work with our premise that it s best to improve the envelope first. Where should we start? Air distribution system leakage Windows Random infiltration and controlled mechanical ventilation Insulation roofs walls slab-edge (below grade walls) Page 9 of 25

Central-fan-integrated supply ventilation Unvented-cathedralized attic configuration Media filter and motorized damper Fan Cycling and Motorized Damper Cycling Control Manual Damper (to adjust flow rate) Gable End Wall Central System Supply Air Heating Coil Cooling Coil buildingscience.com Thermostat Wall Cap Motorized Damper (to control open time) Outside Air Duct 5" Insulated Flex-duct Media Filter Main Return Duct Gypsum Ceiling Central Return Box Return Grille Page 10 of 25

If I could change two things! #1 All refrigerant cooling systems would have factory installed TXV s Thermal expansion valves meter refrigerant to the evaporator and automatically adjust refrigerant flow over a range of system charge and environmental conditions Super heat controller protects the compressor from liquid refrigerant Maintains system efficiency under a wide range of operating conditions, precise charging is less important Page 11 of 25

Pressure vs. Enthalpy Diagram of the Idealized Vapor Compression Refrigeration Cycle subcooling p-h dome or saturation dome 3 condenser 2 Pressure, p expansion device * T=const buildingscience.com compressor 4 evaporator 1 superheat Enthalpy, h * TXV, fixed orifice, or capillary tube - Superheat is equal to the vapor line temperature minus the vapor saturation temperature, and is required to make sure that only vapor reaches the compressor - Subcooling is equal to the liquid saturation temperature minus the liquid line temperature, and is required to make sure that only liquid reaches the expansion device Page 12 of 25

Thermal expansion valve (TXV) refrigerant metering device buildingscience.com distributor tubes pressure sensing tube temperature sensing bulb TXV TXV Page 13 of 25

TXV Advantages According to research by Proctor Engineering, the performance loss using a TXV metering device is about 5% if the refrigerant charge is off by plus or minus 20%. The performance loss using a fixed metering device (capillary tube or orifice) is about 15% to 20% if the refrigerant charge is off by plus or minus 20%. According to a California Energy Commision report, installing TXV s in all systems would increase the seasonal efficiency 11%. Page 14 of 25

What if I think the TXV cost is too high? Then compare it to the cost of: only starting up fixed metering systems when the environmental conditions are favorable to getting a target superheat of 5 F or greater waiting a long time while you: add or subtract charge by trial and error let the system settle for 20 minutes before taking new readings and hope the superheat is within 3 F of spec repeat as necessary then often find that the house has cooled down such that your indoor wet bulb temperature is too low to give a target superheat greater than 5 F, so you have to heat the house and start over again (let s hope the gas meter has been set) coming back to do this again within the warranty period because of a customer complaint and a slow refrigerant leak Page 15 of 25

Page 16 of 25 source: California Energy Commision report 2001

Phoenix, AZ Maximum outdoor drybulb to use listed minimum indoor wet bulb 1100 ft elev 63 73 84 100 112 Possibility of 5+ F target superheat at listed minimum indoor wet bulb Indoor, Tdp 50 55 60 65 68 Jan 35 yes heat to 78 no no no Feb 35 yes heat to 78 no no no Mar 35 yes heat to 78 no no no Apr 37 yes yes no no no May 38 yes yes no no no Jun 44 yes yes yes no no Jul 60 n/a n/a n/a yes heat to 84 Aug 62 n/a n/a n/a yes heat to 81 Sep 55 n/a n/a yes heat to 83 no Oct 46 yes yes heat to 80 no no Nov 38 yes yes no no no Dec 35 yes heat to 78 no no no buildingscience.com When it's not more than: 63 F outside, you can check superheat any time (except Jul-Sep when it will never be <63 outside) 73 F outside, it's workable, but requires some pre-heating in winter, and Jul-Sep are out 84 F outside, Jun and Sep are good, Jul-Aug are out, Oct requires pre-heating to 80 F, the rest higher 100 F outside, Jul-Aug are good months, Sep requires pre-heating to 83 F, the rest are out 112 F outside, Jul-Aug require pre-heating to 81 and 84 respectively, the rest are out Page 17 of 25

Phoenix, AZ Maximum outdoor drybulb to use listed minimum indoor wet bulb 1100 ft elev 63 73 84 100 112 Minimum indoor drybulb to reach listed minimum indoor wet bulb Outdoor, Tdp Indoor, Tdp 50 55 60 65 68 Jan 33 35 66 78 91 106 116 Feb 33 35 66 78 91 106 116 Mar 33 35 66 78 91 106 116 Apr 35 37 64 76 89 104 113 May 36 38 63 75 89 103 113 Jun 42 44 57 69 65 97 107 Jul 58 60 -- -- -- 75 84 Aug 60 62 -- -- -- 71 81 Sep 53 55 -- -- 68 83 93 Oct 44 46 55 67 80 95 105 Nov 36 38 63 75 89 103 113 Dec 33 35 66 78 91 106 116 buildingscience.com When it's not more than: 63 F outside, you can check superheat any time (except Jul-Sep when it will never be <63 outside) 73 F outside, it's workable, but requires some pre-heating in winter, and Jul-Sep are out 84 F outside, Jun and Sep are good, Jul-Aug are out, Oct requires pre-heating to 80 F, the rest higher 100 F outside, Jul-Aug are good months, Sep requires pre-heating to 83 F, the rest are out 112 F outside, Jul-Aug require pre-heating to 81 and 84 respectively, the rest are out Page 18 of 25

If I could change two things! #2 Get rid of the caveman appliances Caveman appliances are those that build a fire inside the dwelling and require air from the dwelling to vent combustion products, or don t vent combustion products at all. Page 19 of 25

Working within the realm of energy-efficient and healthy housing, it can be frustrating to worthless dealing with the various code issues, and the work of verification for: vent types, sizes, clearances, horizontal distances make-up air dilution air worst case depressurization back-drafting Let s do-- Sealed combustion only inside conditioned space! Page 20 of 25

Page 21 of 25

Page 22 of 25 source: Freus Air Conditioning

Page 23 of 25 source: Freus Air Conditioning

Page 24 of 25 source: California Energy Commision report 2001

Page 25 of 25 source: California Energy Commision report 2001