DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Similar documents
MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Advance Release September 2009

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SKYPAK II Heating & Cooling Self Contained Packages

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

VertiCool Aurora Engineering Guide

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

PAR5. Product Specifications

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

PACKAGE AIR CONDITIONER

Commercial High-Efficiency Condensing Units

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Split System Heat Pumps

PAJ3. Product Specifications

C13-Series Engineering Guide

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

MAC N-407 Air-Cooled Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

WCH5**4. Product Specifications

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

High Heat COP. High/Low Stage

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

VariCool VAV Engineering Guide

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

R4H4. Product Specifications

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Air-Cooled Condensing Units with Compact Screw Compressors

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Now In Production JULY 2008

4YCC3048A3096A /3/ /

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

N4H4. Product Specifications

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL SPECIFICATIONS

50TM TFF COMBINATION HEATING/COOLING UNITS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Roof Top Packaged Unit (RTU-1) Specification

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

50TM COMBINATION HEATING/COOLING UNITS

Cooling/Heat Pump Convertible Air Handlers

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

R4H4. Product Specifications

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

48TF GAS HEATING/ ELECTRIC COOLING UNITS

WJH4 Product Specifications

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

JCseries EVAPORATIVE CONDENSER. engineering data

GENERAL ELECTRIC AIR HANDLING UNITS DIRECT EXPANSION. ABQ Series ABQ03 thru ABQ TR thru 30 TR 9 kw thru 105 kw

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

GREEN REFRIGERANT R-410A

AIR COOLED SPLIT SYSTEMS LIGHT COMMERCIAL RANGE UN-PRC001-EN

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Transcription:

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal Energy Efficiency Ratio: 13.0 SEER** Net Cooling Capacity [Btuh]: 37,000** Net Cooling CFM: 1,200 Evaporator Coil Face Area: 5.16 [sq ft] Rows/FPI : 3 / 10 Refrigerant Control: TX Valve Condenser Coil Face Area: 7.03 [sq ft] Rows/FPI: 3 / 12 Evaporator Fan No./Type: 10x8 Motor HP: 0.33 Compressor No./Type: Refrigerant Circuits: Refrigerant: 1/Scroll 1/ Independent R-410A Condenser Fan No./Type: 12x12 Motor HP : 1.0 Filters - Qty./Size: Operating Weight [lbs.]: 610 Shipping Weight [lbs.]: 650 Condensate Connection: 2/18x24x2 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 # CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1000 605 0.11 732 0.16 839 0.19 941 0.26 1051 0.31 DSV036A 1200 675 0.17 788 0.23 890 0.29 988 0.34 - - 1400 749 0.26 849 0.32 - - - - - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL # OUTDOOR CFM 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSV036A 2200 622 0.39 720 0.50 802 0.60 961 0.69 953 0.79 ELECTRICAL DATA COMPRESSOR CONDENSER FAN MIN. CCT. "MOP" MODEL # VOLTAGE Max Overcurrent AMPACITY QTY RLA LRA HP FLA Protection DSV036A1 208-230/1/60 1 @ 14.1 77.0 1.00 6.7 27.53 40 DSV036A2 208-230/3/60 1 @ 9.0 71.0 1.00 3.0 16.05 25 DSV036A4 460/3/60 1 @ 5.6 38.0 1.00 1.4 9.20 15 DSV036A5 575/3/60 1 @ 3.8 36.5 1.00 1.1 6.45 15 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DESCRIPTION: DSV036 VERTICAL AIR-COOLED SELF-CONTAINED AIR CONDITIONER UNIT SPECIFICATIONS Form 145.13-PA1 (1108) Page 2

GENERAL All models 3-5 tons ship as factory-charged unitized packages. All units may be field split and installed as separate modules to suit on-site requirements. All packages are designed for free standing mounting on the floor, or on a field fabricated structural steel stand. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge, condenser intake, and evaporator discharges are provided with the unit for field installation. Duct flange on evaporator return is incorporated into the filter frame. REFRIGERANT CIRCUITS All models utilize "Scroll" type, R-410A, hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 3-5 ton units have a single refrigeration circuit. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Both coils are employed in a draw-thru configuration. Large evaporator coil face area minimizes potential water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2-inch thick medium-efficiency throwaway filters factory installed. Filter rack is external to the cabinet (shipped loose). 2 of 3 FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). Johnson Controls maintains a continuous product improvement policy; therefore specifications are subject to change without notice. DESCRIPTION MECHANICAL SPECIFICATION R-410A DSV SERIES VERTICAL INDOOR AIR CONDITIONING UNITS Form 145.13-PA1 (1108) Page 3

3 of 3 Form 145.13-PA1 (1108) Page 4

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 50,100* Design CFM: 1,600 Seasonal Energy Efficiency Ratio: 13.0 SEER** Net Cooling Capacity [Btuh]: 49,000** Net Cooling CFM: 1,600 Evaporator Coil Face Area: 5.46 [sq ft] Rows/FPI : 3 / 12 Refrigerant Control: TX Valve Condenser Coil Face Area: 7.94 [sq ft] Rows/FPI: 4 / 14 Evaporator Fan No./Type: 10x10 Motor HP: 0.5 Compressor No./Type: Refrigerant Circuits: Refrigerant: 1/Scroll 1/ Independent R-410A Condenser Fan No./Type: 12x15 Motor HP : 1.0 Filters - Qty./Size: Operating Weight [lbs.]: 670 Shipping Weight [lbs.]: 715 Condensate Connection: 2/20x24x2 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 # CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1450 735 0.24 845 0.30 950 0.38 1037 0.45 1134 0.52 DSV048A 1600 788 0.31 889 0.38 987 0.46 1076 0.55 - - 1800 870 0.43 962 0.51 - - - - - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL # OUTDOOR CFM 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSV048A 2600 719 0.61 800 0.71 870 0.85 940 0.98 - - ELECTRICAL DATA COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" MODEL # VOLTAGE Max Overcurrent AMPACITY QTY RLA LRA HP FLA HP FLA Protection DSV048A1 208-230/1/60 1 @ 19.9 109.0 0.50 4.4 1.00 6.7 35.98 50 DSV048A2 208-230/3/60 1 @ 13.1 83.1 0.50 2.1 1.00 3.0 21.48 30 DSV048A4 460/3/60 1 @ 6.1 41.0 0.50 1.0 1.00 1.4 10.03 15 DSV048A5 575/3/60 1 @ 5.0 34.0 0.50 0.8 1.00 1.1 8.15 15 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DESCRIPTION: DSV048A VERTICAL AIR-COOLED SELF-CONTAINED AIR CONDITIONER UNIT SPECIFICATIONS Form 145.13-PA2 (1108) Page 5

GENERAL All models 3-5 tons ship as factory-charged unitized packages. All units may be field split and installed as separate modules to suit on-site requirements. All packages are designed for free standing mounting on the floor, or on a field fabricated structural steel stand. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge, condenser intake, and evaporator discharges are provided with the unit for field installation. Duct flange on evaporator return is incorporated into the filter frame. REFRIGERANT CIRCUITS All models utilize "Scroll" type, R-410A, hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 3-5 ton units have a single refrigeration circuit. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Both coils are employed in a draw-thru configuration. Large evaporator coil face area minimizes potential water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2-inch thick medium-efficiency throwaway filters factory installed. Filter rack is external to the cabinet (shipped loose). 2 of 3 FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). Johnson Controls maintains a continuous product improvement policy; therefore specifications are subject to change without notice. DESCRIPTION MECHANICAL SPECIFICATION R-410A DSV SERIES VERTICAL INDOOR AIR CONDITIONING UNITS Form 145.13-PA2 (1108) Page 6

3 of 3 Form 145.13-PA2 (1108) Page 7

1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 62,900* Design CFM: 2,000 Seasonal Energy Efficiency Ratio: 13.0 SEER** Net Cooling Capacity [Btuh]: 61,000** Net Cooling CFM: 2,000 Evaporator Coil Face Area: 5.46 [sq ft] Rows/FPI : 3 / 12 Refrigerant Control: TX Valve Condenser Coil Face Area: 7.94 [sq ft] Rows/FPI: 4 / 14 Evaporator Fan No./Type: 10x10 Motor HP: 1.0 Compressor No./Type: Refrigerant Circuits: Refrigerant: 1/Scroll 1/ Independent R-410A Condenser Fan No./Type: 12x15 Motor HP : 1.5 Filters - Qty./Size: Operating Weight [lbs.]: 720 Shipping Weight [lbs.]: 765 Condensate Connection: 2/20x24x2 3 / 4 NPT *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F wet bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ARI Standard 210/240-2006 EVAPORATOR FAN PERFORMANCE MODEL # DSV060A SUPPLY CFM 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1800 860 0.41 945 0.50 1039 0.58 1130 0.67 1208 0.76 1280 0.83 1359 0.85 1435 0.96 2000 926 0.55 1010 0.63 1098 0.72 1178 0.81 1250 0.90 1325 0.99 - - - - 2200 1007 0.72 1085 0.80 1160 0.90 1230 0.99 - - - - - - - - NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. CONDENSER FAN PERFORMANCE MODEL # OUTDOOR CFM 0.2 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSV060A 3000 886 0.87 838 0.99 920 1.12 1002 1.29 1055 1.47 ELECTRICAL DATA COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. "MOP" MODEL # VOLTAGE Max Overcurrent AMPACITY QTY RLA LRA HP FLA HP FLA Protection DSV060A2 208-230/3/60 1 @ 16.0 110.0 1.00 3.2 1.50 4.3 27.50 40 DSV060A4 460/3/60 1 @ 7.8 52.0 1.00 1.5 1.50 2.1 13.35 20 DSV060A5 575/3/60 1 @ 5.7 38.9 1.00 1.2 1.50 1.7 10.03 15 Johnson Controls maintains a continuous product improvement policy, therefore specifications are subject to change without notice. DESCRIPTION: DSV060A VERTICAL AIR-COOLED SELF-CONTAINED AIR CONDITIONER UNIT SPECIFICATIONS Form 145.13-PA3 (1108) Page 8

GENERAL All models 3-5 tons ship as factory-charged unitized packages. All units may be field split and installed as separate modules to suit on-site requirements. All packages are designed for free standing mounting on the floor, or on a field fabricated structural steel stand. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge, condenser intake, and evaporator discharges are provided with the unit for field installation. Duct flange on evaporator return is incorporated into the filter frame. REFRIGERANT CIRCUITS All models utilize "Scroll" type, R-410A, hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 3-5 ton units have a single refrigeration circuit. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Both coils are employed in a draw-thru configuration. Large evaporator coil face area minimizes potential water blow-off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2-inch thick medium-efficiency throwaway filters factory installed. Filter rack is external to the cabinet (shipped loose). 2 of 3 FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). Johnson Controls maintains a continuous product improvement policy; therefore specifications are subject to change without notice. DESCRIPTION MECHANICAL SPECIFICATION R-410A DSV SERIES VERTICAL INDOOR AIR CONDITIONING UNITS Form 145.13-PA3 (1108) Page 9

3 of 3 Form 145.13-PA3 (1108) Page 10