SAM-MAX Refrigerant Monitors

Similar documents
SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Series 9000 Total Hydrocarbon Analyzer

Chillgard Refrigerant Monitor

HIGH CAPACITY PRODUCT LINE

Ammonia Leak Detector Manual

Installation Operation Maintenance

HIGH CAPACITY PRODUCT LINE

Ammonia Detection System Codes and Design Specifications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Recalibrate the way you look at gas detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Refrigerant Leak Detector Manual

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Sieger Apex. Flexibility that meets your requirements

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING, MAINTAINING OR SERVICING THIS PRODUCT.

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Craig Wolfe Toxalert International, Inc. Mound, MN

Danfoss gas detection units

Liquid Helium Level Instruments

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Sensor unit MC2 with analog output for Freon gases and refrigerants

APPLICATION DATA SHEET

Refrigerant Leak Detection Solutions

Danfoss gas detection units

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Mercury Vapor Monitor VM-3000

Toxic Gas Detection. Model F12. Toxic Gas Detection

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

continuous emissions monitoring Combustion & Environmental Monitoring

PUV, PIR and PFO Series BROCHURE

PACKAGED REFRIGERATION EQUIPMENT

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

VM-3000 Mercury Vapor Monitor

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

TOOLS AND INSTRUMENTS

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Recent Improvements in Process GC Instrumentation

PRODUCT LINE. Highest Quality, Best Service

Danfoss Gas Sensor DGS MODBUS

HPLC Column Ovens and Temperature Controllers

Model OEM-2 INSTRUCTIONS FOR USE

wireless. web-based. worthy of the name RACO.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Hydrazine Analyzer Series 2171 Specifications

Industrial Grade Gas Detection

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

MSA Fixed Gas & Flame Detection for the Automotive Industry

Model D12-IR. Digital Gas Transmitter...

EC FX NH3. A new and improved approach to ammonia gas detection

Pioneer-R16 Gas Monitor Operator s Manual

Danfoss gas detection unit Type GD Heavy Duty

Products and performance

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Using the DewTrak II Dew Point/ Humidity Transmitter

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Maxline 2 Thermal Imaging Solutions for Manufacturing

Model Q45P/R. ph/orp Monitor...

Constant climate chambers

Warranty Registration

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Nitrogen Generation Systems Compressed Air Dryers

VM-3000 Mercury Vapor Monitor

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Industrial Grade Gas Detection Detecting The Difference

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Warranty Registration

Model Q45P/R. ph/orp Monitor...

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

APPLICATION DATA SHEET

Transcription:

SAM-MAX Refrigerant Monitors Monitor Refrigerants Including CFCs, HFCs and Ammonia Monitor Carbon Monoxide Exceeds ASHRAE 5-99 and USEPA 608 Monitoring Requirements Provide for Single or Multipoint Sampling A World of Solutions

SAM-I MAX and SAM-IV MAX As a result of the mandatory phaseout of CFCs and HCFCs, the refrigeration industry is perhaps one of the most rapidly evolving industries of the decade. Rising refrigerant costs and the introduction of new alternative refrigerants have made refrigerant management, conservation, and safety increasingly important issues. The ASHRAE 5-99 safety and USEPA 608 leak rate requirements make monitoring of refrigerants in equipment rooms mandatory. Simple economics makes refrigerant monitoring a necessity. The new SAM-MAX product line from OI Analytical offers different cost-effective alternatives for the continuous monitoring of refrigerants with almost any chiller configuration. ADVANCED INFRARED TECHNOLOGY All SAM-MAX continuous refrigerant monitors use patented infrared technology to detect refrigerant gases as low as ppm. The SAM-MAX s unique optical design allows it to be compound-specific, which practically eliminates nuisance alarms from other compounds that may be present. OI Analytical s patented small, low volume Macro Light Pipe TM gas cell allows for rapid instrument response to changes in concentration levels. RUGGED AND COMPACT DESIGN The new SAM-MAX incorporates the monitor and sample manifold in one compact, watertight package. One instrument can monitor up to sample points with optional expansion module packages. Samples can be collected from distances of up to 500 feet. SAM-MAX monitors are less sensitive to vibration and temperature fluctuation than most units and can be mounted on the wall, rack, or the refrigeration or HVAC equipment itself. Easily integrate the SAM-MAX into your building control system. Three level alarms warn against refrigerant leaks. Standard outputs include 20 ma and a choice of RS-85 or RS-232. Optional Windows -based software is available for remote control of all parameters of the SAM-MAX monitors. RELIABLE, UNBEATABLE PERFORMANCE Each system is factory calibrated and easy to install...no NEED TO CALIBRATE UPON START-UP OR DURING THE FIRST YEAR OF OPERATION. Refrigerant concentration levels are indicated on the digital display. Alarm messages identify the problem area and the alarm level. Diagnostic indicators pinpoint any system malfunction. Thousands of SAM continuous refrigerant monitors are currently installed to monitor chillers around the world. SAM-MAX monitors are installed in mechanical rooms, supermarkets and refrigerant storage locations, propellant filling operations, solvent cleaning stations, and wherever else refrigerant leaks may occur or exposure monitoring is required. SAM-MAX monitors come with a one year parts and factory service warranty and are backed with unmatched technical support worldwide.

...The Ideal Refrigerant Monitors Zero and particulate filter assemblies included with the monitor ensure long-term, drift-free, unattended operation without expensive humidity sensor calibrations. A 6-character alphanumeric LCD display indicates the concentration levels, alarm messages, and system diagnostics. Sample points sample from a distance of up to 500 feet. The watertight enclosure protects the monitor from water. The SAM-I MAX features one sample point, while the SAM-IV MAX has four sample points. A transparent window allows the operator to view the display without compromising system stability. DETECTION: AFFORDABLE: RELIABLE: CAPABLE: Detect leaks sooner at lower levels Avoid costly leak rate reporting (USEPA 608) Stop wasting money on inferior detectors Refrigerant leak detection to ppm NO FALSE ALARMS caused by nuisance gases Simultaneously monitor up to three refrigerants including HCFC-23, HFC-3a, HCFC-22, CFC-, CFC-2, or monitor ammonia or carbon monoxide USER SERVICEABLE: Modular design, built-in diagnostics Never take the unit off the wall again! SELECTIVY: Gas Specific NO FALSE ALARMS

The Flow Solution IV SAM-MAX the Refrigerant Mon...Beyond the Limits! Sample manifold for up to four solenoid valves for collecting sample and one solenoid valve for auto zero feature Voltage selectable power supply 00 V or 220 V operation Continuous flow sample pump On-board software enables easy and quick adjustment of parameters Low volume, Macro Light Pipe TM gas cell for rapid low level detection Three level alarm contacts and self-diagnostics Patented infrared-detector optical system for maximum sensitivity Malfunction alarm for flow loss, temperature, and analytical errors SAM-IV MAX Customized SAM-MAX packages are available for different equipment room configurations. The SAM-I MAX is ideal for monitoring leaks from one or two chillers. The SAM-IV MAX provides a low cost per point alternative when additional coverage is required or where multiple chillers are installed. Select the monitor to meet your needs. Sample Points Gases Simultaneously Monitored Standard Outputs RS232 or RS85 (standard) -20 ma * Multiplex Outputs Relay Set (Low, Med, High) Optional Relay Board Set of 3 (Low, Med, High) SAM-I MAX N/A N/A SAM-IV MAX w/exps Module w/exps Module -PRT 8-PRT -PRT 8-PRT 8 8* 7 7* * Single or multiple point refrigerant monitoring Monitor up to locations Detects leaks early, to limits as low as ppm, saving energy, averting damage to chillers, and preventing USEPA fines Meets ASHRAE 5-99 standards and provides early warning system for potential EPA 608 leak violation Factory calibrated no need to calibrate on start-up Three adjustable alarm levels with relay closures Complete system self-diagnostics with malfunction relay closure Zone Alarms or Individual Chiller Shut-down Standard Configuration with Optional Relay Board N/A Windows Control Software On-board Diagnostics Trouble-free operation minimal maintenance Customized to monitor any refrigerant, including HCFC-23, HFC-3a, HCFC-22, CFC-, CFC-2, or monitor ammonia or carbon monoxide Monitor combinations of refrigerants

itor with MAXimum ABILILTY. Zero Filter Sample Ports /" or 5 /6" Diameter Bolts for Mounting INSTALLATION TIPS Correct measurement of the refrigerant concentration in a given area requires proper installation of the SAM-MAX and the proper placement of its sampling point(s). Here are some general guidelines: 7 /2 inches.5 cm 6 inches 0.6 cm SAM MAX 2 inches 30.5 cm 3 /2 inches 3.3 cm The SAM-MAX monitor should be rigidly mounted indoors on a wall or rack so that its display is readily visible and the unit is easily accessible for servicing. Sampling tubes can extend up to 500 feet from the monitor. Locate them 2 8 inches above the floor in an area where refrigerant vapors are most likely to concentrate. Most refrigerant gases are heavier than air and tend to accumulate near the floor and especially in areas such as pits and stairwells. Large pits and stairwells should be wellventilated and monitored separately. RS-22, RS-85, or RS-232 Momentary Switch Meter Meter Meter Meter 20 ma Output TXD RCD Ground Alarm Reset Port Port 3 Port 2 Port Alarm Contacts Low Level Alarm Normally Open Level Selectable Mid Level Alarm Normally Open Level Selectable High Level Alarm Normally Open Level Selectable Malfunction Alarm Normally Closed Ground Mounting and wiring diagrams demonstrate the easy installation of the SAM-MAX. Chiller equipment configuration is important in selecting sampling points. In general, if there is only one chiller, monitor at its perimeter. For two or more chillers, monitor between each one. Consider airflow patterns and activity levels when positioning sampling tubes. Hardwire alarm contacts to audible or visual alarms, equipment room ventilation systems, and/or Building Management Systems (BMS). These are just a few recommended guidelines. For complete details and requirements, consult local building codes, ASHRAE 5-9 and EPA 608 standards, the SAM-MAX Monitor Operator s Manual, and your OI Analytical representative.

SAM-MAX Accessories Calibration Kit The Calibration Kit is used to calibrate the SAM-MAX in about three minutes! Kit includes a regulator, connection fittings, zero air canister, and calibration gas standard packaged in a convenient carrying case. Expansion Module Multipoint Expansion Modules expand the SAM-MAX s sampling capabilities up to points per monitor and can be easily installed on-site. When additional chillers are added or additional sample points are needed, the expansion module provides a convenient, and cost-effective solution to meet your needs. Alarm Horn and Beacon Alarm horn and beacon provide audible and visual notification of an alarm condition or a system malfunction. Remote Alarm Panel Provides visual monitoring of the alarm status and a remote reset for the alarms. Remote Digital Display Allows a single port to be monitored from a convenient remote location. Sample Heater Assembly Controls the temperature of the sample air before it enters the SAM-MAX which is perfect for applications where sample air is below 50 F. Filter Package Refills Zero filter and particulate filter package refills are available for easy routine maintenance. Windows-based Software User-friendly software enables remote control of the monitor parameters.

SAM-MAX Specifications PERFORMANCE Sensing technology: Patented infrared Number of sample points SAM-I MAX: One Expandable to eight SAM-IV MAX: Four Expandable to eleven Range: ppm,000 ppm Standard Calibration: 00 ppm ±2 ppm for most gases 00,000 ppm ±5% Optional Calibration: 00 ppm ± ppm for most gases 00,000 ppm ±2% Lower limit of detection for most common refrigerants: ppm Sensitivity: ppm Linearity: Linear over entire range Reproducibility: ± ppm over a 2 month period Response time: 90% of level change in 20 seconds INPUTS & OUTPUTS Alarm relays: 3 relays at 5 amps resistive (optional relay board adds 9 additional relays) Malfunction relay: 5 amps resistive Analog outputs: 20 ma for each point (up to four) Digital communications: Choice of RS-85 or RS-232 Digital inputs: Choice of RS-85 or RS-232 OPERATING CONDITIONS Temperature: 0 0 C (32 0 F) Relative humidity: 0 99%, non-condensing Power requirements: 85 250 VAC, 50/60 Hz Power load: 75 watts MECHANICAL Maximum sample tube length per point: 500 feet Sample tubing connections: ¼ inch O.D. Sample flow rate: 2 liters/minute Dimensions: 6" H x 3.5" W x 7" D (0.6 cm x 3.3 cm x 7.8 cm) Weight: 32 lb (.5 kg) A World of Solutions

C U S T O M E R C A R E Our commitment to your satisfaction begins when you consider buying an OI Analytical instrument. We strive to develop and maintain a one-on-one relationship to carry you successfully through the purchase experience and throughout your future with OI Analytical s instruments. This highly regarded relationship is cultivated through customer focused programs. Service OI Analytical has made a long-term commitment to Contracts outstanding customer service with a continuously AT ï YOUR ï SERVICE growing network of support services designed to provide high quality service to our customers. OI Analytical offers a wide range of service products to fit your needs. For details call -800-653-7. Customer Communications A domestic toll-free technical support hotline is available for instrument support as well as specialized applications. Applications and instrument training and seminars are available on-site or in-house. OI Analytical provides innovative products used for chemical analysis. The Company develops, manufactures, sells, and services analytical instrumentation that detects, measures, analyzes, and monitors chemicals in liquids, solids, and gases. The Company also provides products used to digest, extract, and separate components of chemical mixtures. OI Analytical provides application-specific solutions for the environmental, defense, pharmaceutical, food, beverage, petrochemical, chemical, semiconductor, power generation, and HVAC industries. End users in these industries use the Company s products for research and development, quality control, analytical services, and process monitoring. OI Analytical provides innovative: Gas Chromatography and GC/MS Systems Selective Detectors for Gas Chromatography Sample Introduction Systems Gel Permeation Chromatography Systems Analytical Microwave Digestion Systems Automated Flow Analyzers (SFA/FIA) Total Organic Carbon Analyzers Continuous Air/Liquid Monitors OI Analytical is proud to provide the highest quality instruments available, backed by a commitment to quality, service, and support. Call -800-653-7. 5 Graham Road, PO Box 900 College Station, Texas 7782-900 FAX (979) 690-00 (979) 690-7 (800) 653-7 USA/Canada www.oico.com E-mail: oimail@oico.com Publication# 672002 A World of Solutions O I C O