Craig Wolfe Toxalert International, Inc. Mound, MN

Similar documents
Ammonia Detection System Codes and Design Specifications

Safety Standard for Refrigeration Systems

ICC CODE CORNER 2015 International Fire Code

INSTALLATION AND OPERATING INSTRUCTIONS

Ammonia Refrigeration RAGAGEP

Guidelines for the Design Engineer

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

incontrol Systems Inc. Flame and Gas Detection

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Warranty Registration

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

Model D12-IR. Digital Gas Transmitter...

MODEL 4200-IR-2 (Up to 2 Sensors) MODEL 4200-IR-4 (Up to 4 Sensors) MODEL 4200-IR-6 (Up to 6 Sensors)

Chillgard Refrigerant Monitor

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

ASHRAE WILL GIVE YOU THE WORLD

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Gas Detection division of Arjay Engineering. Gas Detection Maintenance Facilities Parking Garages Warehouses. EN-GD-11a

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Two-Channel Gas Controller

COLUMBIA PUBLIC SCHOOLS HVAC IMPROVEMENTS - PHASE COLUMBIA, MISSOURI

SAM-MAX Refrigerant Monitors

Danfoss gas detection units

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

IMC Significant Changes Summary Tier I

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Danfoss gas detection units

Honeywell SLATE ICM Platform

Ammonia Leak Detector Manual

JAMES MOODY IM FLASH LIFE SAFETY AHJ

SEMICONDUCTOR FABRICATION FACILITIES

GAS DETECTION. Parking Garage Guide

Gas detection in refrigeration systems

Recalibrate the way you look at gas detection

Power Flame Incorporated

SEMICONDUCTOR FABRICATION FACILITIES

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Smoke detection in hazardous areas:

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

SEMICONDUCTOR FABRICATION FACILITIES

Fixed Ammonia Gas Detection. Why it's needed and what it can do for you.

HALOGUARD TM II MULTI-GAS MULTI-SENSOR MONITOR INSTRUCTION MANUAL

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

AT-G-SENSE Gas Sensing System

Danfoss Gas Sensor DGS MODBUS

SEQUENCE OF OPERATIONS

Products and performance

CO and NO 2 Monitoring Systems for Parking Structures

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

1. PURPOSE This standard specifies safe design, construction, installation, and operation of refrigeration systems.

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor

MSA Customer Service MSA-INST

Danfoss gas detection unit Type GD Heavy Duty

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS

CAUTION & SYMBOL DEFINITIONS:

Inc Series Digital Gas Detector/Controller. Operation Manual

SenSmart Universal Gas Detector Series

Functional Performance Test

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Todd Jekel, Assistant Director, IRC Feb. 8, Standard Definition. What is a machinery room?

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Multi-Gas-Controller MGC2

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Industrial Grade Gas Detection Detecting The Difference

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Remote Storage Safety 3 Alarm Installation Guide

Control Sequence Number

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

Bold items are particular to the City of Euless

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Refrigerant Leak Detector Manual

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

You in Control PRODUCT OVERVIEW

Transcription:

Craig Wolfe Toxalert International, Inc. Mound, MN

Codes & Standards Technologies & Locating Sensors System Maintenance

Codes and Standards ANSI/ASHRAE 15-2007 International Mechanical Code (IMC) 2006 International Fire Code (IFC) 2006

Codes and Standards ANSI/ASHRAE 15-2007 Safety Standard for Refrigeration Systems

ASHRAE 15-2007 Forward Care should be taken to avoid stagnant pockets of refrigerant vapors by proper location of ventilation inlet and exhaust openings. All machinery rooms are required to have detectors that will activate an alarm and mechanical ventilation at a value not greater than the corresponding TLV-TWA. Informative Appendix I provides guidance on integrating the requirements of this standard with occupational health & safety programs.

ASHRAE 15-2007 8.11 Refrigerating Machinery Room, General Requirements. 8.11.2.1 Each machinery room shall contain a detector, located in an area where refrigerant from a leak will concentrate, that actuates an alarm & mechanical ventilation at a value not greater than the corresponding TLV-TWA (or toxicity measure consistent therewith). The alarm shall annunciate visual & audible alarms inside the refrigerating machinery room & outside each entrance to the refrigerating machinery room. The alarms required in this section shall be of the manual reset type with the reset located inside the refrigerating machinery room..

ASHRAE 15-2007 8.11.6.Combustion equipment shall not be installed in the same machinery room with refrigerant-containing equipment except under one of the following conditions: (a) combustion air is ducted (b) a refrigerant detector, is employed to automatically shut down the combustion process in the event of refrigerant leakage.

ASHRAE 15-2007 8.12 Machinery Room, Special Requirements. 8.12.i. Remote control of mechanical equipment in the refrigerating machinery room shall be provided immediately outside the machinery room door solely for the purpose of shutting down the equipment in an emergency. Ventilation fans shall be on a separated electrical circuit and have a control switch located immediately outside the machinery room door.

Codes and Standards 2006 IMC 1101.6 General. Refrigeration systems shall comply with the requirements of this code and, except as modified by this code, ASHRAE 15. Ammonia-refrigerating systems shall comply with this code and, except as modified by this code, ASHRAE 15.

2006 IMC 1105.3 Refrigerant detector. Refrigerant detectors in machinery rooms shall be provided as required by Sections 606.8 of the International Fire Code.

2006 IMC 1106.5 Remote controls. Remote control of the mechanical equipment and appliances located in the machinery room shall be provided as required by Sections 606.8 of the International Fire Code.

2006 IMC 1106.5 Remote controls. 1106.5.1 Refrigerant system. A clearly identified switch of the break-glass type shall provide off-only control of electrically energized equipment and appliances in the machinery room, other than refrigerant leak detectors and machinery room ventilation.

2006 IMC 1106.5 Remote controls. 1106.5.2 Ventilation system. A clearly identified switch of the break-glass type shall provide on-only control of machinery room ventilation fans.

Codes and Standards 2006 IFC 606.8 Refrigerant detector. Machinery rooms shall contain a refrigerant detector with an audible and visual alarm. The detector, or a sampling tube that draws air to the detector, shall be located in an area where refrigerant from a leak will concentrate. The alarm shall be actuated at a value not greater than the corresponding TLV-TWA values shown in the International Mechanical Code for the refrigerant classification. Detectors and alarm shall be placed in approved locations.

2006 IFC 606.9 Remote controls. Remote control of the mechanical equipment and appliances located in the machinery room shall be provided at an approved location immediately outside the machinery room and adjacent to its principal entrance.

2006 IFC 606.9 Remote controls. 606.9.1 Refrigerant system. A clearly identified switch of the break-glass type shall provide off-only control of electrically energized equipment and appliances in the machinery room, other than refrigerant leak detectors and machinery room ventilation.

2006 IFC 606.9 Remote controls. 606.9.2 Ventilation system. A clearly identified switch of the break-glass type shall provide on-only control of machinery room ventilation fans.

Sensor Technologies Monitoring Systems Locating Sensors

Sensor Technology Common Types Of Refrigerant Leak Sensors Metal Oxide Semiconductor (MOS) Non Dispersive & Photoacoustic Infrared

Sensor Technology MOS SENSOR Heater Coil Sensor Element Pin

Sensor Technology Infrared Sensor LIGHT FILTERS SENSOR CHAMBER LIGHT DETECTOR INFRARED LIGHT SOURCE SIGNAL PROCESSOR

Leak Detection Systems Sampling Systems & Electronic/Diffusion Systems

Leak Detection Systems Sampling System CONTROLLER EXHAUST LINE DRAW PUMP SENSOR SOLENOID VALVES TUBING SAMPLE POINT FILTERS

Leak Detection Systems Electronic/Diffusion System CONTROLLER REMOTE SENSORS

Leak Detection Systems Features Multi-Stage Control LCD Display of Refrigerant Concentration Visual Indicators for Power On Stage of Activation Fault Fan Auto/Purge Switch Audible Alarm With Silence Switch Manual/Auto Warning Stage Reset Switch

Leak Detection Systems Options Analog output (4-20mA or 0-10vdc) Integral strobe RS 232/485 communications for modbus, BACnet

Leak Detection Systems Typical Control CONTROLLER 120VAC FIRST STAGE SECOND STAGE FAULT

Locating Sensors Guide lines to properly locating a refrigerant sensor in an equipment room is: (a) determining the airflow pattern in the room; (b) remembering that occupant safety is the primary motive for installing the sensor; and (c) All commonly used refrigerants except ammonia are 3 to 5 times heavier than air.

Locating Sensors As a Minimum General Guide Locate sensors so no chiller is more than 50 ft. from a sensor.

CHILLER CHILLER CHILLER CHILLER Locating Sensors EXHAUST REFRIGERANT LEAK MONITOR PANEL AIR INTAKE REFRIGERANT SENSOR

CHILLER CHILLER CHILLER CHILLER Locating Sensors EXHAUST REFRIGERANT LEAK MONITOR PANEL AIR INTAKE REFRIGERANT SENSOR

CHILLER CHILLER CHILLER Locating Sensors REFRIGERANT LEAK MONITOR PANEL AIR INTAKE EXHAUST REFRIGERANT SENSOR

CHILLER CHILLER CHILLER Locating Sensors REFRIGERANT LEAK MONITOR PANEL AIR INTAKE EXHAUST REFRIGERANT SENSOR

Leak Monitoring System STROBE/REM HORN/REM SCBA TOX-REFRIG PANEL TOX-REFRIG/ANA CH-1 CH-2 ALM/REFRIG TOX-REFRIG/ANA BOILER STROBE/REM HORN/REM

Maintenance ASHRAE Standard 15 11.6.3 Periodic tests. Detector(s), alarm(s), and mechanical ventilating systems shall be tested in accordance with manufacturers specifications and the requirements of the jurisdiction having authority.

Maintenance 2006 IMC 1109.1 Testing required. The following emergency devices and systems shall be periodically tested in accordance with the manufacturer s instructions and as required by the code official: 1109.1.4 Detection and alarm systems.

Maintenance 2006 IFC 606.6.1 Periodic testing. The following emergency devices and systems shall be periodically tested in accordance with the manufacturer s instructions and as required by the fire code official: 606.6.1.4 Detection and alarm systems.

Maintenance MOS/Diffusion System Periodic Maintenance Sensor calibration

Maintenance Sampling Infrared System Periodic Maintenance Sensor calibration Sample point filters Internal filter

Maintenance Calibration kit

Questions?