CentreVu Call Management System. Release 3 Version 8 Alarm Origination Manager

Similar documents
User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

safety & regulatory information

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Avaya Proactive Contact Release 5.x

Emotron M10 Shaft Power Monitor. Instruction manual English

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Oracle Communications Performance Intelligence Center

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

IFS Fiber Module Installation & Operation Instructions

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

IFS Fiber Module Installation & Operation Instructions

ShockLink. Important Product Information.

IFS Fiber Module Installation & Operation Instructions

Operation and Maintenance Manual

Panic. Part Number SYSTEMS, Inc.

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Oracle Retail Furniture Retail System (FRS) Pricewriter to Xmargin Guide Release October 2015

IFS Fiber Module Installation & Operation Instructions

Emotron DCM Control Unit

Architectural and Engineering Specification for a Real-Time Locating System Flare

IFS Fiber Module Installation & Operation Instructions

The New EMC Directive 2004/108/EC

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Using your LED Plus keypad

New Features in Oracle R Enterprise 1.4.1

SEE DISCLAIMER ON REVERSE

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Instruction manual SPU II Hard alarm output contacts

IFS Fiber Module Installation & Operation Instructions

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

The System 5000 Operating Manual

Wireless Weather Station

IFS Fiber Module Installation & Operation Instructions

Oracle Retail Management System Release Notes Release Spanish. January 2008

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

Applying the Patch Release

The New EMC Directive 2004/108/EC

Hardware and Software Requirements

Copyright Notice. Thinklogical, LLC 100 Washington Street Milford, Connecticut U.S.A. Telephone:

Declaration of Conformity

Cancelling the Emergency Call Process...22 Line Seize Functionality...22 Direct to 911: Triggering an Emergency Call Directly to

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

ADT. Pulse 2017ADT LLC

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Architectural and Engineering Specification for a. Flash / Flare

The European Radio Equipment Directive 2014/53/EU

Electrolux Reseller FAQs

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

IMS Operation Manual. Version 1.1. Phonetics, Inc.

ELECTRONIC COMMUNICATING THERMOSTAT : P COOL AUTO. Owner's Manual

IFS Fiber Module Installation & Operation

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Oracle Retail Distribution Management Release Notes Release October 2007

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Version 2.0, September P DocuColor 7000AP/8000AP. Safety Guide

ELECTRONIC COMMUNICATING THERMOSTAT COOL AUTO. Hold Prog Mode Fan. Owner's Manual. RC-120 Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool

Intrinsically Safe Transmitters, Option Code 2n

ELECTRONIC COMMUNICATING THERMOSTAT

Frymaster Fryer Controllers

Oracle Retail Allocation Release Notes Release November 2007

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

Town of Cochrane Policy

Avigilon Control Center 5 System Integration Guide

LORAIN CSP DC Power System

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

Avigilon Control Center System Integration Guide

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

OnGuard 7.2 Resolved Issues

Manage Alert Rules & Teams

Impassa CDMA Module INSTALLATION GUIDE

Conditions for the provision of services Valid from 1 November only for the Jablotron Alarms series of alarms

New Legal Framework Carlo Casati

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

The RPT-485W/RPT-485WF

Conformity assessment procedures for the Alarm Components Scheme

3M Benchtop Air Ionizer 963E. User s Guide

Version 2.1 September Xerox 700 Digital Color Press. Safety Guide

ExiCheck Gas Exchange Accessory

Australian/New Zealand Standard

Oracle Retail Management System Release Notes Release November 2007

field SENSE EC-FS2-001-A

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

Disclaimer. Trademarks. Copyright. Warranty

Atomic Digital Office Clock

Network Camera. Quick Guide DC-T1233WHX. Powered by

Avigilon Control Center System Integration Guide

Transcription:

CentreVu Call Management System Release 3 Version 8 Alarm Origination Manager 585-215-884 Comcode 108771197 Issue 1 June 2000

Copyright 2000 Lucent Technologies All Rights Reserved Printed in U.S.A. Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change. Your Responsibility for Your System s Security Toll fraud is the unauthorized use of your telecommunications system by an unauthorized party, for example, persons other than your company s employees, agents, subcontractors, or persons working on your company s behalf. Note that there may be a risk of toll fraud associated with your telecommunications system and, if toll fraud occurs, it can result in substantial additional charges for your telecommunications services. You and your system manager are responsible for the security of your system, such as programming and configuring your equipment to prevent unauthorized use. The system manager is also responsible for reading all installation, instruction, and system administration documents provided with this product in order to fully understand the features that can introduce risk of toll fraud and the steps that can be taken to reduce that risk. Lucent Technologies does not warrant that this product is immune from or will prevent unauthorized use of common-carrier telecommunication services or facilities accessed through or connected to it. Lucent Technologies will not be responsible for any charges that result from such unauthorized use. Lucent Technologies Fraud Intervention If you suspect that you are being victimized by toll fraud and you need technical support or assistance, call Technical Service Center Toll Fraud Intervention Hotline at 1-800-643-2353. Canadian Department of Communications (DOC) Interference Information This digital apparatus does not exceed the Class A limits for radio noise emissions set out in the radio interference regulations of the Canadian Department of Communications. Le Présent Appareil Nomérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A préscrites dans le reglement sur le brouillage radioélectrique édicté par le ministére des Communications du Canada. Trademarks CentreVu and DEFINITY are registered trademarks of Lucent Technologies. Sun, Sun Microsystems, SunOS, the Sun logo, Solaris, Solstice, Solstice DiskSuite, Enterprise, and Ultra are trademarks or registered trademarks of Sun Microsystems, Inc. Exatape is a trademark of Exabyte Corporation. INFORMIX is a registered trademark of Informix Software, Inc. All other product names mentioned herein are the trademarks of their respective owners. Ordering Information Call: Lucent Technologies Publications Center Voice: 1-800-457-1235 International Voice: +1-317-361-5353 Fax: 1-800-457-1764 International Fax: +1-317-361-5355 Write: Lucent Technologies Publications Center P.O. Box 4100 Crawfordsville, IN 47933 U.S.A. Order: CentreVu CMS R3V8 High Availability Connectivity, Upgrade and Administration Document No. 585-215-8841 Comcode 108771197 Issue 1, June 2000 For additional documents, refer to the section entitled Related Documents in the Preface. You can be placed on a Standing Order list for this and other documents you may need. Standing Order will enable you to automatically receive updated versions of individual documents or document sets, billed to account information that you provide. For more information on Standing Orders, or to be put on a list to receive future issues of this document, please contact the Lucent Technologies Publications Center. Lucent Technologies National Customer Care Center Lucent Technologies provides a telephone number for you to use to report problems or to ask questions about your call center. The support telephone number is 1-800-242-2121. Document Support Telephone Number Lucent Technologies provides telephone numbers for you to use to report errors or to ask questions about the information in this document. The support telephone numbers are: Voice: 1-888-584-6366 and International Voice: +1-317-322-6848. European Union Declaration of Conformity Lucent Technologies Business Communications Systems declares that the equipment specified in this document conforms to the referenced European Union (EU) Directives and Harmonized Standards listed below: EMC Directive 89/336/EEC Low Voltage Directive 73/23/EEC The CE mark affixed to the equipment means that it conforms to the above Directives. Heritage Statement Lucent Technologies formed as a result of AT&T s planned restructuring designs, builds, and delivers a wide range of public and private networks, communication systems and software, consumer and business telephone systems, and microelectronics components. The world-renowned Bell Laboratories is the research and development arm for the company. Comments To comment on this document, return the comment card at the front of the document. Acknowledgment This document was developed by the Lucent Technologies Information Development Organization for Global Learning Solutions.

Introduction 1 About Alarm Origination Manager Introduction 0 The CentreVu CMS Supplemental Services R3V8 software package includes an enhancement called Alarm Origination Manager (AOM), which allows for remote alarm management and centralized error logging. AOM sends immediate notification of errors to the Lucent Technologies Technical Service Center personnel, who can proactively display the errors and resolve them before you lose valuable data. You must have CMS R3V8aj.e or higher to have AOM. If you have an earlier version of CMS, you will need to upgrade. AOM runs on the Sun Microsystems, Inc. Solaris server. It operates independently on each CMS R3V8 server, which means that each server sends and logs alarms independently of the other CMS R3V8 servers.the errors may be logged into the AOM error log, the customer log, or the alarm log. Note: The AOM feature is available only for US/Canada CMS systems for which a current Maintenance Warranty Agreement is in effect. Expiration of Warranty and/or a Post Warranty Maintenance Agreement will result in the deactivation of the AOM. Administering AOM 0 After a V5 or V6 to V8 Speed Center upgrade, the Lucent Technologies provisioning group will work with an on-site Technician to swap the disk. After the V8 system is running, the provisioning group sends a request to the Technical Services Organization (TSO) Database Administration support personnel to administer and activate AOM. Registration needs to occur only once. If AOM is already active on the system, no further action is necessary. The customer is responsible for performing a baseload upgrade (for example, r3v8af.f to r3v8aj.e). Once the upgrade has been completed, the customer must contact the Database Administration Group to register AOM.

Administering AOM 2 To register AOM, follow these steps. Step Action 1 At the command prompt, enter: pkginfo -x cms The program displays output similar to the following example: cms Lucent Technologies CentreVu(R) Call Management System (sparc) r3v8aj.e 2 If the installed CMS version is r3v8aj.e or higher, the AOM software must be administered. To register AOM, contact the Database Administration Group at the following E-mail address: tsodba@lucent.com Include the following information in your AOM registration request: 1. In the subject line, enter CMS AOM registration 2. CMS Installation Location Number (IL) - the IL is a 10-digit number which is often found on labels affixed to the CMS server or local switch. 3. CMS dial-up number (the phone number for the modem on your CMS) 4. Your point-of-contact phone number. Note: Lucent technicians and CMS provisioning engineers can call 800 248-1234; select prompts. 2, 6, 1, 2. Callers are required to enter identification information to gain access to the DBA group. Authorized dealers must call the Business Partner Care Center at 800-225-0266; select prompts 4 and 4 for registration.

How AOM Works 3 How AOM Works 0 Whenever the AOM receives an error, it writes this error to a log. At a specified error threshold level, AOM sends an alarm via modem to a remote computer system, such as INADS. The remote system generates a trouble ticket for the Lucent Technical Service Center (TSC) personnel. Errors or conditions that exceed a certain threshold are defined as active alarms and result in a call to the remote system alarm receiver. The thresholds that cause a condition to become alarmable are link outages, archiver and harchiver errors, and disk full or disk read/write errors. Some examples of alarm types are: ARCH HARCH DISK ACDLINK[i] ECH_WARNING ECH_FAILURE (TEST_ALARM & ES_ALARM) Receiving and Resolving Active Alarms 1 Services personnel are responsible for administering alarm events, including Expert Systems (ES) and test alarms, on either a local or remote system. A typical scenario might include the following: Step Action 1 The AOM receives an error that exceeds the threshold that makes it alarmable. 2 The AOM transmits this active alarm event to a remote alarm receiver. 3 The AOM automatically creates a TSC trouble ticket, which is forwarded to Services personnel. 4 Services receives the TSC trouble ticket and enters a call to the active alarms program, which displays a list of currently active alarms for the customer site. 5 Services fixes the condition and enters a alarm-resolve command, causing the alarm to no longer appear on the active list.

How AOM Works 4