Universal fuel unit for oil burners

Similar documents
Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Light oil burners. One stage operation

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTALLATION & OPERATING INSTRUCTIONS

568X, 587X, 588X Series

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Light oil - kerosene burner

Parts Available from

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Climate Control System

1998 Expedition/Navigator Workshop Manual

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation Instructions

SuperKlean Washdown Products

Series 1140 and 1141 Temperature Regulators

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

Installation & Maintenance Manual

V SERIES HDR GAS RANGES

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

A/C-HEATER SYSTEM - MANUAL

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Model 601CRD Oil Burner

Venco 75mm (3 ) Standard and De-airing Pugmill

TECHNICAL DATA. Wet 26a. February 22, 2009

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Forced draught gas burner

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Light oil / kerosene burner

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

569, 570, 571, 572 Series

569, 570, 571, 572 Series

TEMPERATURE CONTROLLERS

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

Oil burners Brûleurs fioul Stookoliebranders

INSTALLATION INSTRUCTIONS

SECTION STEAM CONDENSATE PUMPS

PBG PACKAGED GAS BURNER

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

DRYAIRE DESICCANT SYSTEM MODEL 6760

Power Washer Maintenance

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

INSTRUCTION MANUAL DN0136 REVISION D

ECLIPSE INFORMATION GUIDE

RL 28/2-38/2-50/2 Low - High Operation

F-LF AND F-PF SERIES

Outdoor Armor Water Heater Installation & Operation Manual Models:

RL 70/2-100/2-130/2 Low - High Operation

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

SELF-PRIMING JET PUMPS

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

FIREPLACE INSTALLATION

INSTALLATION INSTRUCTIONS

HEATING AND AIR CONDITIONING

Single stage operation oil burner

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

BERMAD Fire Protection

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Raffaello From serial number Group

INSTALLATION INSTRUCTIONS WARRANTY

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

MODEL CMA-180UC PARTS MANUAL Rev 1.18

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

ST 40 Oil Burner. Installation & Maintenance Manual

Indirect gas-fired air heater

American Dish Service

Instructions for Installation, Operation, Care and Maintenance

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

INSTALLATION INSTRUCTIONS

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

This label warns for risk of electrical shock when failing to observe.

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Equipment Maintenance Checklist

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

Operating Instructions. Rotating Vacuum Filter Type VRF

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Dosing system. Commissioning and maintenance manual eco-pen300

Service Step by Step Trouble-Shooting Check-List

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

REMOVE AND INSTALL AIR CLEANER ASSEMBLY

Installation & Maintenance Manual

15 20 kw kw kw

Teflon Rotary Drum Pump

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

LGB Gas fired boiler

Single stage operation oil burners

MODEL HI-100i / HI-140i

Owner s manual for. Venco 87mm & 100mm. (3 1/ 2 & 4 ) De-airing Pugmill

Transcription:

Universal fuel unit for oil burners Type U www.deltapumps.com European patent Certified Quality System rinted in Italy - DE115/0404

Universal Fuel Unit for oil burners Type U The DETA Universal Fuel Unit is an efficient and modern oil burner pump, provided with bilateral delivery ports and suitable for clockwise and counter clockwise rotation. Since its mounting flange, hub and shaft sizes are manufactured to international standards (EN 225), it can be fitted to every oil burner. 1 1- Features 9 9 High suction capability. Suitable for one or two pipe systems. Clockwise and counter clockwise rotation. Bilateral delivery ports. 8 3 Self priming (two pipe). eliable pressure and positive cut-off. 7 Shaft lip seal (ev. B). Silent operation. ow power absorption. Easily installed and adjusted. 2 4 ressure and vacuum gauge ports. 6 5 2- Applications The Universal Fuel Unit type U is designed for pumping oil in high pressure oil burners and transfer pump applications. Its features allow an easy pump replacement with every other type of oil pump: the same unit is provided with nozzle port in both the left and right side, and is suitable for clockwise and counter clockwise rotation. WANING It must not be used to pump water or acid. 3- Operation The U fuel unit consists of a pump, solenoid valve, filter and pressure regulator valve (1) housed within one casting. The pumping action is obtained from two spur gears, one of which is connected to the drive shaft (3). The pump casting provides the various oil ways, for the suction (6), return (5) and nozzle ports (9). ressure (8) and vacuum (7) gauge ports are also provided. Under the vacuum gauge is located the rotation selector (2). See the Installation and Service Section. The U unit is supplied in two pipe version (self priming) On start up, the rotating gears purge the air from the suction chamber, through a vent groove in the piston to the return line in two pipe version, and through the nozzle line (after the solenoid valve opening) in one pipe version. On initial commissioning, it is possible to bleed the air more quickly, through the pressure gauge port. Because a vacuum now exists oil, due to atmospheric pressure, enters the suction chamber through the filter. From the suction side, the gears pass the oil to the pressure chamber, where it comes up against the head of the piston. Due to the build up of pressure, the piston is forced back against the pressure regulating spring. The flow of pressurized oil is interrupted by an incorporated solenoid valve, and can, therefore, be opened following the start of the motor (pre-purge), or interrupted before stopping the motor itself (instant shutoff of the flame preventing the nozzle dripping). The excessive oil discharges to the return side (or by-passes in the one pipe version). It will be realized of course that the spring tension, which is varied by the regulator screw, regulates the pressure of oil required. The pump can be converted from the two pipe version to the single pipe version, removing the by-pass plug (4) from the return port. When the unit is converted to the single pipe version, on initial commissioning the air must be bled through the pressure gauge port (in this case lift installation are not recommended). 2 rinted in Italy - DE115/0404

4- Technical specifications Oil viscosity. 1,2 12 cst Oil temperature... 60 C max. ressure range... 6 18 bar. Suction line vacuum... 0,5 bar max. Suction line pressure. 2 bar max. eturn line pressure.. 2 bar max. otation speed 3500 M max. Strainer. Nylon mesh 150µ, 20 cm² Dimensions (EN 225). Hub dia. 32, shaft dia. 8 Connections (ISO 228/1)... Inlet - eturn port: G1/4" Nozzle ports: Gauges: ipes system... Single pipe or Two pipe otation Clockwise or counter clockw. Nozzle line... Bilateral Weight.. 1050 gr. 8- Diagrams /h 75 50 25 CAACITY isc. 5 cst (1.4 E) 2800 M 5 10 15 20 Bar 5- Solenoid valve specifications ower absorbed 9 W oltage tolerance -15% / +10% Environment temp. 0 C / 60 C Working pressure 25 bar max. Flow factor (DI/DE 2173) 0,059 m 3 /h Cut-off pressure 6 bar Approval (EN 264) TÜ No. 5S102/04 Watts 150 OWE ABSOTION isc. 5 cst (1.4 E) 2800 M 6- Standard factory setting 100 Working pressure... 10 ±0,3 bar otation Counter clockwise Nozzle line... ight side (seen from cover) ipes system... Two pipe Standard coil... 230AC 50/60 Hz Standard cable set... 3 cores, 700 mm cable length 50 5 10 15 20 Bar 7- Overall dimensions ressure egulation 14 102 Ø32 Ø8 7 63 Nozzle ort UNIESA FUE UNIT Made in Italy INET ETUN Nozzle ort 23 42 19 96 54 28 40 ressure Gauge Inlet ort G1/4" U European atent N I E 25 72 S A acuum Gauge otation Selector under the plug eturn ort G1/4" 3 rinted in Italy - DE115/0404

9- By-pass plug installation To convert the DETA fuel unit from the two pipe version to the single pipe version, do the following: a) Using a 4 mm Allen key, unscrew the by-pass plug from the return port (Fig. 1). b) Fit a 1/4" plug into the return port (Fig. 2). WANING - In the two pipe version the air is bled through the return port. After conversion, the air must be bled manually, through the pressure gauge port. - Make sure that the by-pass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and burner motor could result. Fig. 3 10- Selection of rotation The U unit is provided with a screw for the selection of rotation, located under the vacuum gauge plug (). To change the direction of rotation do the following: UNIESA FUE Made INET aten T20 a) Using a screw driver, remove the 1/8" plug from vacuum gauge port. Under the plug, inside the pump, is the selector screw. b) Turn it 90 up to the stop, to change the rotation (Fig. 3). U N After conversion, check the O-ring is located on the bottom of the vacuum port and replace the 1/8" plug. Fig. 1 Fig. 4 Clockwise Counter Clockwise Fig. 2 UNIESA FUE UNIT Made in Italy INET ETUN atent pending T2000U000022 U N I E S A WANING The selection screw must be oriented with the groove vertical () or horizontal (), otherwise the fuel unit will not function properly and damage could result (Fig.4). 19 4 rinted in Italy - DE115/0404

Installation and Service Instructions 11- Installation and maintenance 1. Make sure that the by-pass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and burner motor could result. 2. The rotation selector must be oriented with the groove vertical () or horizontal (). 3. Do not use fuel with additives to avoid the possible formation over time of compounds which may deposit between the gear teeth, thus obstructing them. 4. After filling the tank, wait before starting the burner. This will give any suspended impurities time to deposit on the bottom of the tank, thus avoiding the possibility that they might be sucked into the pump. 5. On initial commissioning a dry operation is foreseen for a considerable length of time (for example, when there is a long suction line to bleed). To avoid damages inject some lubrication oil into the vacuum inlet. 6. Care must be token when installing the pump not to force the pump shaft along its axis or laterally to avoid excessive wear on the joint, noise and overloading the gears. 7. Do not force the valve stem and do not use it as lever. 8. ipes should not contain air pockets. The number of junctions should be kept to a minimum as they are a possible source of leakage. 9. apid attachment joint should therefore be avoided. Always use O-ings or mechanical seal (copper or aluminium gaskets) junctions if possible. 10. Avoid overtightening: 15 Nm max. G1/4" 20 Nm max. 11. Do not use TFE tape on the suction and return line pipes to avoid the possibility that particles enter circulation. These could deposit on the pump filter or the nozzle, reducing efficiency. 12. When junction threads, elbow joints and couplings are sealed with removable glue, avoid excessive quantities, which could enter in the oil ways and damage to the pump could result. 13.To clean the filter remove the cover. It must be thoroughly cleaned at least once in a season to ensure correct working of the fuel unit. The filter must be mounted with the supporting legs leaned against the pump body. If the joint plate between cover and pump housing should be damaged, it must be replaced. An external filter should always be installed in the suction line upstream of the fuel unit. 14. Make sure the combustion chamber is free of oil or oil vapor before operating the system. CAUTION: Turn off all power before servicing any part of the system. 12- Nozzle pressure test Most nozzles ratings are based upon 100 SIG delivered oil pressure. The flow rate at the desired pressure must be estimated using the nozzle manufacturers data sheets. To insure that oil is delivered to the burner nozzle at the desired pressure, do the following: 1. emove the 1/8" plug from the port marked "" and connect a pressure gauge to this port (use a gauge of 0 to 300 SIG or greater). The "" port (ressure Gauge Test ort) has been provided specifically for the connection of the pressure gauge for measuring the nozzle pressure; however, when available, it is also permissible to use the vent port for measuring nozzle pressure. 3. Check the adjustable nozzle pressure range of the fuel unit, using a 4 mm Allen key, turning the adjusting screw counter clockwise to lower the nozzle pressure and clockwise to increase the nozzle pressure. CAUTION: Adjust the nozzle pressure in accordance with the burner manufacturers specifications. 13- Nozzle cut-off test Fuel oil is not compressible but air is. Air trapped in the nozzle line, anywhere between the fuel units nozzle port and the nozzle itself, will compress during burner operation. Following burner shutdown, any trapped compressed air will expand displacing the oil in the nozzle line, forcing continued oil flow through the nozzle that will, in effect, falsely appear to be poor fuel unit Cut-Off. This occurrence is particularly common with low flow rate nozzles used in conjunction with long air tubes. To verify positive nozzle Cut-Off after burner shutdown, do the following: 1. emove the nozzle line and fitting from the nozzle port of the fuel unit and connect a 1/8" pressure gauge to the nozzle port (a gauge of 300 SIG or greater be used). It may be more convenient to use a gauge fitted out with an extension nipple or with a line and flare nut to connect directly to the fitting installed into the nozzle port. If any type of extension is used between the nozzle port and the gauge, it should be kept as short as possible to minimize the amount of trapped air. 3. Shut off the burner motor. Initially the pressure will drop and then stabilize within a second or two. The pressure reading on the gauge should stabilize at 6 bar or greater and hold for at least two minutes. 14- acuum test The vacuum test is necessary to verify the fuel unit's suction ability, to evaluate the leak tight integrity of the entire fuel unit and connected oil suction line piping system, to confirm that there are no abnormal restrictions in the oil suction line system, and, to confirm that the system vacuum is within the allowable specification limits of the unit. lease watch in any case the graphs for maximum suction line length depending on line diameter, viscosity, difference in height of suction line and pump or nozzle capacity. To perform the test, do the following: 1. emove the 1/8" plug from the port marked "" and connect a vacuum gauge to this port. 3. With the burner motor running, close the valve connected to the inlet port. You will note that the vacuum as measured by the vacuum gauge will increase. Allow the burner motor to continue to run until the highest vacuum reading is achieved. A fully primed fuel unit in good condition should be capable of pulling at least 20 lnhg. If not, before condemning the fuel unit, be sure that all connections and plugs are tight, the cover gasket is in good condition and the valve is in good working order. 4. De-energize the solenoid valve and shut off the burner motor. Initially, the vacuum reading will drop and then stabilize within a second or two. Once the vacuum reading stabilizes, record the reading. If the fuel unit is free of leaks, this reading should hold constant for at least 2 minutes. If the vacuum reading drops, there is a leak that must be located and corrected. 5. When each leakage is removed and the valve onto suction line is open, check to be sure that the actual operating vacuum does not exceed 15 InHg. Elettromeccanica Delta S.p.a. reserves the right to update or make technical changes without prior notice. 5 rinted in Italy - DE115/0404