Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Similar documents
Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Wiring Instructions (01-09)

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

TS93 EMR WITH SMOKE DETECTOR

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

1400 Direct Wire Ionization Smoke Detector

Installation Instructions

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

INSTALLATION AND MAINTENANCE

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

DH400 Air Duct Smoke Detector

2408/2900. Fire Guard

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

DH500ACDC Intelligent Air Duct Smoke Detector Housing

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

DH100ACDCI Ionization Air Duct Smoke Detector

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

2409/2900. Fire Guard

DH100ACDCI Ionization Air Duct Smoke Detector

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Installation Guide for models:

TECHNICAL DATA OBSOLETE

MANUAL RESET ALARM RELEASE

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

Installation Guide for models:

4100U City and Relay Cards Installation Instructions

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

DH500 Intelligent Air Duct Smoke Detector Housing

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model 17A00 Expansion Enclosure

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

E-PDD Duct Smoke Detector Installation Sheet

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

7200 Series. Electromechanical Closer/Holder Releasing Devices

SP-1000X. Panic Device Power Controller Installation Guide. Rev

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Addressable Detectors & Bases

MANUAL RESET ALARM RELEASE BOX

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Duct smoke housings, 4-wire D341/D341P and D342/D342P

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MODEL B2 INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

Operator: Save these instructions for future use!

MANUAL RESET ALARM RELEASE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

TS93 EMF SERIES. INSPK NO Rev.03/10

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Smoke Alarm User s Manual

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

XPS-ProDry User s Guide Dryer Base

EHT/EHTD. Electromechanical Closer-Holder Release Devices

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

Duct smoke housing, 2-wire D340/D340P

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

AL600ULADA. NAC Power Extender. Installation Guide

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Series. Access Power Controllers. Installation Guide

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Operator: Save these instructions for future use!

SHORT WAVE INFRARED PANEL DRYER

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Statement of Responsibilities

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Interrupted Ignition Series Oil Primary Control

INSTALLATION INSTRUCTIONS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Installation Instructions

INSTALLATIONN GUIDE & OPERATION MANUAL

50A Integrated Furnace Control

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

FX-PDD Duct Smoke Detector Installation Sheet

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

ISIMET Series Shop Controller

Public Safety DAS Annunciator Panel

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Transcription:

Wiring Instructions for the 900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE. For assistance, contact SARGENT at 800-8-WIRE (9) or www.sargentlock.com INSTALLER: LEAVE INSTRUCTION with building owner.. DISCONNECT ALL POWER BEFORE BEGINNING INSTALLATION TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE.. INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE PERSON. CAUTION. ALL WIRING MUST COMPLY WITH APPLICABLE LOCAL ELECTRICAL CODES, ORDINANCES AND REGULATIONS.. MAXIMUM WIRE SIZE IS 8AWG. Wiring - Units with and without 9- Companion Unit Wire - smoke detector unit to appropriate power supply and fire alarm Refer to data sticker for proper input voltage and current specifications 9- Companion units are designed to work with - smoke detector units (-90, -990, -0) only Wire companion unit to - smoke detector unit as shown on wiring diagram if required Do not disconnect any existing wires on smoke detector unit s terminal strip Energize power supply. Current draw. AMP per - unit. Open door(s) to hold-open point. Door(s) should hold open Depress On/Off test switch on circuit board. Doors should close and latch Adjustment of spring power may be necessary to ensure proper latching Depress On/Off test switch to reactivate hold open latch assembly(s) Terminal strip for power input wiring Opening for surface or concealed wiring 9- Companion Unit (If required) Data Sticker Yellow Red Yellow Black Black Black Field wiring by others Wire nut - Smoke Detector Unit On/Off Test switch Wiring Optional Remote Push Button User supplied normally closed momentary switch Yellow Red 9 RED LED/ Reset Switch 0VAC Line Supply Neutral Earth Ground Smoke detector unit Earth ground connection is required when 0VDC power is used *0VAC wiring shown Self resetting fuse Circuit board 0VAC or VAC/DC (0VAC shown) *0VAC Circuit Board shown Remove jumper and install output connector assembly (Part No. -88) required for this option Wire the appropriate Supply to circuit board. is either 0VAC or VDC/VAC depending on circuit board supplied. When VDC/VAC board is supplied, wire VDC/VAC power supply to + and - terminals on circuit board. *CAUTION: Refer to data sticker on circuit board for proper input voltage required. Do NOT wire 0VAC power to VDC/VAC circuit board. A08B

Smoke Detector Operation and Application The closer/holder unit includes a -wire, photoelectric type smoke Connection List Function Terminal detector. It provides: smoke detection, door holder solenoid control, VDC input, N.O. alarm contact, N.C. supervisory contact and interconnection to other smoke detectors. Field option: one form C auxiliary contact (cut Alarm contacts, jumper wire between and ). Solenoid + Solenoid - 9 Terminal Inputs and Outputs Aux + 8 Aux - VDC input power is applied to terminals and by the adjacent circuit board. Red LED flashes every 8 seconds Interconnect + Terminals and provide a normally open (alarm) contact. This contact closes when smoke is detected. Red LED illuminates continuously Terminals and provide a normally closed supervisory (trouble) Interconnect - Trouble contacts +VDC output (unfiltered), contact. This contact opens when power is lost to the detector circuity. Red LED stops flashing NOTE: Terminals, and are same point. Terminals 9 and provide rectified, unfiltered VDC to the door holder solenoid. This power is cut in alarm and the door closes Terminals and 8 provide rectified, unfiltered VDC to auxiliary devices when the detector alarms Terminal is rail + output. It is a continuous, rectified, unfiltered VDC used for remote detector interconnect applications Terminals 8, 9 and may be field configured to a dry form contact by cutting jumper between terminal and. Terminal is Common, 9 is N.C. and 8 is N.O. If this is done, Aux.+ is lost; solenoid power must be supplied by a separate source. Terminals and provide interconnections to other detectors (See diagram Pg. ). Up to five smoke detectors may be interconnected. When a single detector alarms, terminal goes high and any interconnected smoke detector will close its doors. The unit that initiated the alarm will have its LED on. The other interconnected units LEDs will flash as normal. Refer to interconnection wiring diagram for connections. Detector Specifications (Part# -, Revision D) Type: Photo-Electric Smoke Detector Complies with UL 8 and UL 8 standards Requirements: VDC +/- % Nominal Sensitivity:. +/-.0%/FT Contact Ratings Alarm and/or Accessory.0 AMPS Max. @ VDC (Resistive load) 0. AMPS Max. @ 0 VAC Trouble Contact 0. AMPS Max. @ VDC (Resistive load) 9 8 A08B

Checkout Procedure. Turn the power to the unit On. Red LED pilot light should illuminate at 8 sec. intervals. Open door to the hold open point. The door should hold open. Manually pull door out of hold open and release. Door should close. Open door to the hold open position. Depress (maintained type) On/Off test switch button on the power supply board. Door should close. Depress On/Off test switch again. Open door to the hold open position. Inducing smoke into the smoke detector chamber assembly will bring the unit into alarm. The red LED will be continuously illuminated and the door will close. After clearing the smoke chamber, reset unit as follows Resetting Instructions. Remote Reset: Cycle main power by turning the facility main power supply OFF then ON. NOTE: If there are other units connected to the same power supply those doors will close. They will have to be reopened returning them to the hold open position. Local Reset: Insert a small flat head screwdriver through the cover and into the slotted light tube on the smoke detector as shown. Turn screwdriver slightly (about /8 turn) clockwise until hitting stop and hold for seconds until the Red LED turns OFF. WARNING: Do not force past the stop. Doing so may damage the smoke detector Once the detector is reset and the smoke has cleared, the detector s Red LED should flash once every 8 seconds. The door(s) should hold open now Smoke Detector Maintenance SARGENT recommends cleaning smoke detectors at least every six months. The frequency of cleaning will depend upon local ambient conditions The smoke detector in this door closer-holder has been enhanced with a feature that detects when a smoke-sensing chamber requires cleaning due to dirt and dust. The need for cleaning is indicated by the flashing of the Red LED light once per second Normal Supervisory Operation Red LED flashes once every 8 seconds Dirty Chamber, needs cleaning Red LED flashes once every second Smoke Detection Red LED is continuously illuminated To clean the smoke detector assembly, follow the instructions below: NOTE: Before servicing the system, notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service. Disable the zone undergoing maintenance to prevent unwanted alarms Chamber Cover and screen Slot for screwdriver To remove cover Slotted light tube (Red LED) RP test point RP test point Remove detector cover and screen assembly using a standard screwdriver. Turn the screwdriver in the cover slot to loosen the cover and carefully rock the cover back and forth until it snaps out of place. See slot location above Inspect chamber for particles and dust. Vacuum the screen, cover, and photo chamber. Then use clean, compressed air to loosen and blow out any remaining debris Before reassembling the detector, be sure all parts are free of dust and debris Replace cover and screen, aligning cover snaps, press cover onto chamber until it snaps into place Measure and record the test voltage at test points RP and RP (see above). If the smoke detector is operating normally and was cleaned effectively, the test voltage will be greater than.90vdc and less than.8vdc. The test voltage will increase with dust accumulation in the smoke sensing chamber. A difference in test voltages over time will provide an indication of dust accumulation Enable system and inform proper authorities system is operational A08B

Interconnection Wiring Diagram # # # Use terminals and to wire detectors in parallel (See #, # and #) Use terminal to signal remote detectors with relay contact only (See # and #) Five detectors maximum # Accessory wire pack - needed for unit interconnection # Remote Detector Relay N.O. C A08B

Typical - Wiring with Alarm Panel Monitoring (Class A) -Wire System by Others The alarm circuit monitors if smoke is detected The detector trouble circuit monitors if power is lost to the detector VDC @ 0.A Max. Supply Board Connect to power * source VAC/DC or 0VAC. supply board and power source must match VDC Solenoid Alarm Circuit Alarm Panel EOL RES Trouble Circuit VDC @ 0.A Max. * Supply Board VDC Solenoid VDC @ 0.A Max. Supply Board * VDC Solenoid NOTES:. End of line (EOL) resistor determined and supplied by others. Terminal numbers shown correspond to position numbers on terminal strip. Additional units may be added as required based on the schematic. See electrical data sheet. Do not overload circuits. Wires are added to header housing by inserting crimped terminal end into housing body until crimped terminal snaps into position. Use accessory wire pack - A08B

Typical Wiring with Alarm Panel Monitoring (Class B) -Wire System The alarm and trouble circuit monitors if smoke is detected VDC @ 0.A Max. (bell, horn, etc.) Connect to power * source VAC/DC or 0VAC. supply board and power source must match Supply Board VDC Latch UL Listed Fire Alarm Panel Alarm and Trouble Circuit To terminal and on additional units or to EOL resistor on last unit VDC @ 0.A Max. (bell, horn, etc.) * Supply Board VDC Latch NOTES:. End of line (EOL) resistor determined and supplied by others. supply voltage must match unit voltage. Terminal numbers shown correspond to position numbers on terminal strip. Additional units may be added as required based on the schematic. See electrical data sheet. Do not overload circuits. Wires are added to header housing by inserting crimped terminal end into housing body until crimped terminal snaps into position. Use accessory wire pack - A08B

These fire protection devices require correct wiring to function. It is the responsibility of the purchaser to provide correct wiring installation. SARGENT accepts no responsibility for incorrect wiring. Devices wired incorrectly may be damaged and this is not covered under warranty. Life safety devices including door release devices require correct positioning and appropriate selection for the required task. It is the responsibility of the purchaser to select appropriate hardware and provide professional installation. It is the responsibility of the purchaser to insure that NFPA and other applicable fire codes are met. Door release devices function properly only if the door is free to close. SARGENT accepts no responsibility for incorrect installation of its equipment. Smoke detectors will not work without power. AC or DC powered smoke detectors will not work if the power supply is cut off for any reason. All high voltage wiring should be undertaken by a qualified professional licensed electrician. It is the responsibility of the purchaser to insure that installation meets all applicable local and national electrical codes. Smoke detectors will not sense fires which start where smoke does not reach the detectors. Smoke from fires in chimneys, in walls, on roofs or on the other side of closed doors may not reach the smoke detector and alarm it.! WARNING! A detector may not detect a fire developing on another level of a building. For this reason, detectors should be located on every level of a building. Smoke detectors have sensing limitations. Photoelectric detectors sense smoldering fires better than flaming fires. Ionization detectors offer a broad range of fire-sensing capability, but they are better at detecting fast, flaming fires than slow smoldering fires. Because fires develop in different ways, and are often unpredictable in their growth, neither type of detector is always best, and a given detector may not always provide warning of a fire. In general, detectors cannot be expected to provide warnings for fires resulting from inadequate fire protection practices, violent explosions, escaping gas, improper storage of flammable liquids like cleaning solvents, other safety hazards, or arson. Smoke detectors used in high air velocity conditions may fail to alarm due to dilution of smoke densities created by such frequent and rapid air exchanges. Additionally, high air velocity environments may create increased dust contamination, demanding more frequent maintenance. Smoke detectors do not last forever. Even though detectors are made to last over years, these components could fail at any time. Therefore, test your smoke detector system per NFPA E at least semiannually. Clean and take care of your smoke detectors regularly. Taking care of the fire detection system you have installed will measurably reduce your liability risks. A08B

SARGENT Optional 80- Prefix Bypass Hold Open Switch for 90, 90 and 990 Fire Guard General Information The 80 Prefix switch allows the initial hold open point to be adjustable from 0 degrees through full door opening. This adjustment is done using a cam on the spindle opposite from where the arm mounts. (Not available with 9- units.) Adjustment Instructions A. IMPORTANT. CAUTION: DISCONNECT ALL INPUT POWER BEFORE BEGINNING INSTALLATION TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT DAMAGE.. INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE PERSON.. ALL WIRING MUST COMPLY WITH APPLICABLE LOCAL ELECTRICAL CODES, ORDINANCES AND REGULATIONS. B. Installation. Mount closer/holder per instruction sheet provided.. Locate switch and cam and loosen both set screws in cam.. Open door to desired holding position and hold open with door stop. Rotate cam until switch roller is on lower section of cam and approximately /" from bottom of incline. Cam should be positioned so when door closes, roller on switch will ride up incline of cam operating the switch. Tighten one set screw in cam with hex key and pull door closed.. Pull door open to desired hold open position. When switch roller travels down to bottom of incline, door closer will function as a standard multi-point holder. Depending on door size and closer fall back, cam may need to be adjusted so that the switch roller is positioned properly for desired door operation. Tighten both set screws firmly. Cam Switch roller Set screw places Top View of Closer/Holder Cam Approx. /" Set screw Set screw Rotation of cam when closing door Rotation of cam when opening door Switch roller Cam in Door Open Position Cam in Door Closed Position 8 A08B