Water & Fountain H418 H421 H425 SPECIALTY LANDSCAPE Typical Applications Reflection Pools Fountain Pools Waterfalls Garden and Shallow Pools Swimming Pools Features Long Lamp Life Rock Guard Superior Performance Low Water Cut-off Heavy Duty Cast ronze Holophane allast Approvals UL/CSA (H421,, ) UL/CSA/CE/C/NEMKO (H425) UL (H418, ) 16
S PECIALTY L ANDSCAPE Product Catalog Water & Fountain Holophane offers special insight into the complex demands of providing efficient, durable lighting for reflection pool and fountain pool lighting. Every luminaire is fashioned from superior materials, and the most advanced photometrics are incorporated into its design. Rigorous programs of quality control and final testing build in that extra dimension of performance and reliability that is a consistent Holophane core value. Holophane s line of fountain and reflecting pool lights, in base mounted styles, accommodates a wide variety of installations and water effects. In addition to a standard range of lamp options, Holophane water and fountain products are especially flattering to many water effects. H421 M M H421 All fountain and reflection pool lights are designed with a temperature sensing, low water cut-off feature to guard against overheating. H425 /SWM /SWM HOLOPHANE Outdoor Lighting S PECIALTY L ANDSCAPE Water & Fountain 17
Water & Fountain SPECIALTY LANDSCAPE Product Features Specifications General Description H418, H421 ase or Yoke Mount: Ideal for shallow pool installation. Compact in size with an over all height of 8 3/8, ase or Yoke Mount: Heavy duty, all cast bronze luminaire for fountain and water effect applications ase or Yoke Mount: Heavy duty cast bronze underwater metal halide luminaire is used in fountains, reflecting pools and illuminating waterfalls H418 M YM H421 M YM M YM H418, H421, Niche Mount: Heavy duty, all cast bronze luminaire with stainless steel formed niche is designed for wet niche installation in floors or wall of fountain pools or water effects and reflection pools H421, H425,, SWM Mount: Heavy duty, all cast bronze luminaires, recessed in stainless steel forming niche designed for wet niche installations in swimming pools Fixture Housing, Door and Rock Guard Heavy wall cast bronze construction. Natural bronze finish M YM M H418 A Gasket Single piece molded U-shaped silicone. Factory Leak Tested All luminaires tested at 10PSI internal pressure while totally submerged in water Fasteners Stainless steel H421, H421 SWM, H425 SWM Low Water Cut-off Temperature sensing low water cut-off standard Power Module M: Holophane magnetic ballast available with 175W source SWM SWM 18
S PECIALTY L ANDSCAPE Product Catalog Holophane s niche and base mounted styles accommodate a wide variety of installations and water effects. ase mounted models are free-standing. Yoke mounted models are designed for stud or mounting bolts. Wet niche types are available in floor and wall mount models. Holophane reflection pool and fountain pool lights are built to meet or surpass Underwriters Laboratories standards, as well as those of the National Electric Code and NEMKO, per standard IEC 598. They meet the safety requirements for fountains and decorative pools. Reflection pool and fountain pool lighting fixtures are not intended for use in swimming pools. Holophane swimming pool lights are built to meet or surpass Underwriters Laboratories standards as well as those of the National Electric Code. They meet the safety requirements for swimming pool lights, which are demanding and prescribe additional safeguards. HOLOPHANE Outdoor Lighting S PECIALTY L ANDSCAPE Water & Fountain 19
Water & Fountain Ordering Information SPECIALTY LANDSCAPE How to Construct a Catalog Number Example: For H418 MYM only H418 1 H418 P38100I 2 TYPE P38100I P38150I P38250I 3 VOLTAGE 4 DISTRIUTION SP 5 M 6 M YM 7 8 STEP 1: STEP 1: (CONT.) H418 H418 M YM Yoke Mount STEP 2: TYPE P38100I PAR 38 MED P38150I PAR 38 MED P38250I PAR 38 MED 1 P38250I is default if no lamp is chosen ase Mount STEP 3: VOLTAGE STEP 4: DISTRIUTION 1 SP Flood Spot 1 Distribution only required if is chosen STEP 5: 1 Convex Lens, Clear CLA Convex Lens, Amber CL Convex Lens, lue 1 default if lens option not chosen M ase Mount YM Yoke Mount STEP 7: STEP 8: 1 Cord from 10 to STEP 9: STEP 10: AL Adjustable Locking ase RSR_ 1 4-24 Riser, Stem available in 2 increments 1 RSR6 will be used if no length specified and AL chosen. Only available with AL base CSA OPTION Canadian Standard Assoc. STEP 1: STEP 2: TYPE H421 H421 M YM 100Q T4 Mini-can 150Q T4 Mini-can 250Q T4 Mini-can 400Q T4 Mini-can 500Q 1 T4 Mini-can 1 500Q is default if no lamp is chosen STEP 3: VOLTAGE STEP 4: 1 Convex Lens, Clear 1 Cord CLA Convex Lens, Amber CL Convex Lens, lue from 10 to 1 default if lens option not chosen STEP 7: STEP 5: M YM ase Mount Yoke Mount STEP 8: CSA OPTION Canadian Standard Assoc. ase Mount Yoke Mount STEP 1: STEP 2: TYPE H418 H418 A P38100I PAR 38 MED P38150I PAR 38 MED P38250I PAR 38 MED 1 P38250I is default if no lamp is chosen STEP 3: VOLTAGE STEP 4: DISTRIUTION 1 SP Flood Spot 1 Required if is chosen STEP 5: STEP 8: 1 Convex Lens, Clear 1 Rock Guard CLA CL Convex Lens, Amber Convex Lens, lue 1 Required on A STEP 9: 1 default if lens option not chosen 1 Cord from 35 to Niche Mount A Adjustable Niche Mount STEP 10: STEP 7: 34 CONDUIT ENTRIES 3/4 NPT on ottom 20
How to Construct a Catalog Number S PECIALTY L ANDSCAPE Product Catalog Example: For H421 only H421 1 100Q 2 TYPE 3 VOLTAGE 4 5 34 6 CONDUIT ENTRIES 7 8 9 H421 100Q 150Q 250Q 400Q 500Q CLA CL CLG CLR 34 STEP 1: STEP 2: TYPE H421 H421 100Q T4 Mini-can 150Q T4 Mini-can 250Q T4 Mini-can 400Q T4 Mini-can 500Q 1 T4 Mini-can 1 500Q is default if no lamp is chosen 2 Holophane magnetic ballast is standard STEP 3: VOLTAGE STEP 4: 1 Convex Lens, Clear CLA Convex Lens, Amber CL Convex Lens, lue 1 is default if lens option not chosen STEP 5: STEP 8: Niche Mount 1 Cord from 35 to CONDUIT ENTRIES 34 STEP 7: 3/4 NPT on ottom Rock Guard STEP 9: STEP 10: CSA OPTION Canadian Standard Assoc. STEP 1: STEP 1: (CONT.) H421 H421 SWM SWM H421 STEP 2: ronze SS 1 Stainless Steel STEP 3: TYPE H421 100Q T4 Mini-can 150Q T4 Mini-can 250Q T4 Mini-can 400Q T4 Mini-can 500Q 1 T4 Mini-can 2 175M E17 MED 1 500Q is default if no lamp is chosen 2 Holophane magnetic ballast is standard STEP 4: VOLTAGE STEP 5: CLS Convex Lens, Swim Niche Mount STEP 7: CONDUIT ENTRIES 34 3/4 NPT on ottom STEP 8: 1 Cord from 35 to STEP 9: APPLICATION SWM Swimming Pool Fixture STEP 10: STEP 11: OPTION CSA 1 Canadian Standard Assoc. 1 H421 only HOLOPHANE Outdoor Lighting S PECIALTY L ANDSCAPE Water & Fountain 21
Water & Fountain Ordering Information SPECIALTY LANDSCAPE How to Construct a Catalog Number Example: 1 2 P56300I 3 TYPE P56300I P56500I P56240ILV P56300ILV P64500I P641000I 175M 4 VOLTAGE 12 M 5 DISTRIUTION M NSP SP W 6 M 7 M YM 8 9 LP STEP 1: STEP 1: M YM M YM M STEP 2: STEP 3: ronze TYPE P56300I PAR 56 MGEP P56500I 1 PAR 56 MGEP P56240ILV PAR 56 Screw Terminal P56300ILV 1 PAR 56 Screw Terminal P64500I PAR 64 MGEP P641000I 2 PAR 64 MGEP 175M 3 E15 MED 1 P56500I-default for V, P56300ILV default for 12V 2 P641000I-default if no lamp is chosen 3 Available in 175W metal halide only STEP 4: VOLTAGE 12 1,2 12V 1 Transformer not included, sold separately 2 Available with only STEP 5: and M Medium Flood NSP Narrow Spot W Wide Flood Flood SP Spot WWD Wall Wash Distribution DISTRIUTION and 1 Convex Lens, Clear CLA Convex Lens, Amber CL Convex Lens, lue C Flat Lens, Clear 1 is default if lens not chosen STEP 7: M ase Mount YM 1 Yoke Mount 1 Available with and only STEP 8: 1 Cord from 10 to IHL ISS 2 WWL 3 CFAM CU CFGRN CFRED STEP 9: 1 Internal Honeycomb Louver Internal Source Shield Wall Wash Louver Color Filter, Amber Color Filter, lue Color Filter, Green Color Filter, Red 1 Available with only 2 Available only with SP distribution 3 Only available with WWD distribution STEP 10: LP 1 Lamp Installed 2 1 Available with only 2 Available with and only STEP 11: OPTION 1 CSA Canadian Standard Assc. 1 and only 22
How to Construct a Catalog Number S PECIALTY L ANDSCAPE Product Catalog Example: For and only 1 2 P64500I 3 TYPE P56300I P56500I P56240ILV P56300ILV P64500I P641000I 4 VOLTAGE 12 M 5 DISTRIUTION M NSP W 6 7 34 8 CONDUIT ENTRIES 34 9 10 CORD SET LENGTH 11 STEP 1: STEP 1: STEP 2: STEP 3: P56300I P56500I 1 P56240ILV P56300ILV 1 (CONT.) ronze TYPE PAR 56 MGEP PAR 56 MGEP PAR 56 Screw Terminal PAR 56 Screw Terminal STEP 3: TYPE (CONT.) P64500I PAR 64 MGEP P641000I 2 PAR 64 MGEP 1 P56500I-default for V, P56300ILV default for 12V 2 P641000I-default if no lamp is chosen STEP 4: VOLTAGE 12 1,2 12V 1 Transformer not included, sold separately 2 Available with only STEP 5: DISTRIUTION M Medium Flood NSP Narrow Spot W Wide Flood 1 CLA CL CLG CLR Convex Lens, Clear Convex Lens, Amber Convex Lens, lue Convex Lens, Green Convex Lens, Red 1 is default if lens option not chosen STEP 7: Niche Mount STEP 8: 34 STEP 9: CONDUIT ENTRIES 3/4 NPT ottom Rock Guard 1 Required for floor mounted luminaires STEP 10: 1 Cord from 35 to STEP 11: STEP 12: OPTION 1 CSA Canadian Standard Assc. 1 only STEP 1: H425 H425 SWM SWM H425 STEP 1: STEP 2: SS (CONT.) ronze Stainless Steel STEP 3: TYPE H425 P56200I PAR 56 MC P56300I PAR 56 MC P56500IL 1 PAR 56 MC P56300ILV 1 PAR 56 Screw Terminal P64500I PAR 64 MGEP P641000I 2 PAR 64 MGEP 1 P56500I-default for V, P56300ILV default for 12V 2 P641000I-default if no lamp is chosen STEP 4: VOLTAGE 12 1 12V 1 Available with H425 only STEP 5: M NSP W 1 CLA DISTRIUTION Medium Flood Narrow Spot Wide Flood Convex Lens, Clear Convex Lens, Amber (CONT.) CL Convex Lens, lue 1 is default if lens option not chosen STEP 7: Niche Mount STEP 8: CONDUIT ENTRIES 34 1 2 1 V only 2 12V only STEP 9: 3/4 NPT on ottom 1 NPT ottom 1 Cord from 35 to STEP 10: APPLICATION SWM Swimming Pool Fixture STEP 11: STEP 12: OPTION CSA Canadian Standard Assc. HOLOPHANE Outdoor Lighting S PECIALTY L ANDSCAPE Water and Fountain 23