CHROMOPHARE D650, D660, D530, & D540 PREINSTALLATION MANUAL

Similar documents
TELETOM EQUIPMENT MANAGEMENT SYSTEMS

Ceiling Mount Pre-Installation Guidelines

Control Panel 2.0 Installation Guide

30901 TL-15 UNITIZED AHD AND RECEIVING SAFE WITH SECUROMATIC AFTER HOUR DEPOSITORY WALK-UP

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Model 9001, Alarm

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

Total Articulating Service Column - TASC 2000 Series

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Model 9001, Alarm

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

MANUAL RESET ALARM RELEASE

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Proximity Series. features: specifications: options: in-wall box. what great systems are built on.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

Guidelines for Earthquake Bracing of Residential Water Heaters

Access Point Mounting Instructions

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

PRE-INSTALLATION GUIDE for MODELS

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

SAPS GUARDRAIL CONCRETE

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

CLASSIC. SIDE CABINET Installation Instructions

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

PRE-INSTALLATION GUIDE for MODELS

SERVICE PARTS/OPERATION for

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Elements Headwall System (P2008A)

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

PRE-INSTALLATION GUIDE

AVANI Grinding Booth

MANUAL RESET ALARM RELEASE

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

INSTALLATION INSTRUCTIONS

Sprinkler Permit Applications

5900 Series X-in Low Energy Power Operator

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

/9308 External Battery Chargers Installation Instructions

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

FIRE ALARM: BY OTHERS, IF REQUIRED.

2409/2900. Fire Guard

Cooktop Chimney Ventilation Hoods

GAS MONITOR Model Model

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

FIRE ALARM: BY OTHERS, IF REQUIRED.

Installation and Operation Manual Low Power (LP) DC Power System

Installation, Operation and Maintenance Instructions

Detection System Model 3500 Series

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Installation Instructions 30 French Door Built-in Wall Ovens

SECTION SPRINKLER SYSTEMS

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Installation/Owner s Manual Models 1504 / 1506

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

5900 SERIES Low Energy Power Operator

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

Installation, Operation & Service Manual

108A OTP1800. Grid Support. General Description

Classic Twelve O clock Cabinet Installation Instructions

AIR ONE PROFILER TOP and SIDE DRYER INSTALLATION MANUAL Part # DRYRPROFLRXXXXXX (ALL COLORS)

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

installation and operation manual for Hunter Ceiling Fans

Installation Instructions. Mira LED Light System

Installation Instructions Induction Cooktop

DONALD H. BERG, ARCHITECT

MBCE-110/230FR Flame Sensor Module

PowerWave 2 Busway System

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

2 PREPARE THE OPENING

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

ISIMET Series Shop Controller

Installation Instructions

WIDE-DISPERSION FLUSH-MOUNT CEILING SPEAKER

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Installation Instructions

PART 4 ELECTRICAL STANDARDS

Transcription:

CHROMOPHARE D650, D660, D530, & D540 PREINSTALLATION MANUAL

Pre-Install Manual: 700000006 Related Publications: 700000088 Operator Manual This manual contains proprietary information of BERCHTOLD Corporation. It shall not be reproduced in whole or in part without the written permission of BERCHTOLD Corporation. ETL/CETL LISTED TO IEC 60601-1. MEDICAL ELECTRICAL EQUIPMENT CHROMOPHARE IS A REGISTERED TRADEMARK OF BERCHTOLD CORPORATION.

PRE-INSTALLATION GUIDE TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION & GENERAL INFORMATION...2 SUPERSTRUCTURE DESIGN AND SPECIFICATION INFORMATION...3 RECOMMENDED DESIGN SPECIFICATIONS...3 MINIMUM DESIGN SPECIFICATIONS BY PRODUCT TYPE...3 ELECTRICAL REQUIREMENTS...5 ELECTRICAL REQUIREMENTS FOR STANDARD MOUNTING...5 STANDARD MOUNTING DETAILS (SEE PAGE 6 FOR LAYOUT DIAGRAM)...6 LOW PROFILE MOUNTING LAYOUT DIAGRAM...7 LOW PROFILE MOUNTING DETAILS (SEE PAGE 7 FOR LAYOUT DIAGRAM)...8 FLAT PANEL PRODUCTS (WITH AND WITHOUT LIGHTS)...9 WALL CONTROL BOX DIMENSIONS...10 SK BOX DIMENSIONS...10 PRE-INSTALLATION GUIDE PUBLICATION HISTORY...11 PUBLICATION HISTORY...11 REV. 2 700000006 Page 1

INTRODUCTION & GENERAL INFORMATION PRE-INSTALLATION GUIDE INTRODUCTION & GENERAL INFORMATION This Pre-Installation Guide details and describes the structural, mechanical, and electrical requirements of the room or site to allow proper installation of BERCHTOLD CHROMOPHARE D-Series Surgical Lights and Flat Panel products. (D-Series Surgical Lights include D650, D660, D530, and D540.) It is intended for use by technical individuals involved in the specification, design, and construction of the room or site, such as architects, structural engineers, contractors, electricians, and pipe fitters. The Hospital and/or its contractors are responsible for the preparation of the room or site including the superstructure design and installation and all other mechanical and electrical requirements described within this guide and those specified by AHJ (Authorities Having Jurisdiction). Painting and flooring need to be completed before the product can be installed. Questions pertaining to the information contained in this guide can be addressed by contacting your local BERCHTOLD Technical Service Representative or BERCHTOLD Technical Service at 1-800-243-5135.This guide is applicable to the following BERCHTOLD products: CHROMOPHARE D650 and D660 CHROMOPHARE D530 and D540 All multiple combinations of the CHROMOPHARE D-Series. Stand alone Flat Panel Products Flat Panel combined with either one or two CHROMOPHARE D-Series lights. 700000006 REV. 2 Page 2

PRE-INSTALLATION GUIDE SUPERSTRUCTURE DESIGN AND SPECIFICATION INFORMATION SUPERSTRUCTURE DESIGN AND SPECIFICATION INFORMATION The customer/contractor has responsibility to ensure the superstructure design meets specifications. BERCHTOLD recommends that a Structural Engineer be involved in the design of the superstructure. Important: Weights and moments must be adjusted when designing for use in seismic zones. Check with your local construction-engineering agency for applicable local and state codes. RECOMMENDED DESIGN SPECIFICATIONS BERCHTOLD Corporation STRONGLY recommends that the superstructure be designed to meet the following specifications. (Reference drawing on next page). Designing to these specifications will allow combinations of Light or Flat Panel product to be hung from the structure. Product Type Weight (T) Moment (M) lbs. ft-lb with less than 0.1 º Light / Flat Panel Combinations 375 1538 Loads to support structure Case Fp Tmax (LBS) Vmax (LBS) Mmax (Ft-#) 1 2.83 760 1107 7713 2 1.89 6.37 739 5663 3 1.54 592 602 4893 MINIMUM DESIGN SPECIFICATIONS BY PRODUCT TYPE If the customer decides to design the superstructure to the requirements of the specific product type, the superstructure design specifications can be found in the table below. Product Type Weight (T) lbs. Moment (M) ft-lb with less than 0.1 º rotation at Single Light 114 360 Double Light or Double Flat Panel 197 656 Triple Light 311 1016 Flat Panel only 114 360 Single Light with Flat Panel 197 656 Double Light with Flat Panel 311 1016 Single Light with Double Flat Panel 311 1016 REV. 2 700000006 Page 3

PRE-INSTALLATION GUIDE SUPERSTRUCTURE DESIGN AND SPECIFICATION INFORMATION A representative superstructure is shown below. The engineer of record must verify that any structure meets all applicable building codes, especially in seismic zones. Important design notes: 1. Four (4) kickers are needed. 2. Kickers should be anchored (welding preferred) to the mounting ring as shown in Detail A. Do NOT anchor to vertical pipe. 3. The Mounting Ring (provided by BERCHTOLD) should be installed flush with the ceiling with the studs pointing down. Call 1-800-243-5135 for additional details. NOTES: 1. LOAD USED FOR DESIGN: TOTAL WT.:------------------375 LB. MAX. STATIC TORQUE 1538 FT-LB 2. MOUNTING RING IS DESIGNED FOR A MAXIMUM BRACE FORCE OF 2500 LBS @ 45 IN BRACING CONFIGURATION SHOWN Mounting Ring ¾ X 12 Internally Threaded Holes for Threaded Rods. Plate Supplied By BERCHTOLD. 6-7/8 Hole PLAN A-A Superstructure Design See Specifications on Page 3 700000006 REV. 2 Page 4

ELECTRICAL REQUIREMENTS PRE-INSTALLATION GUIDE ELECTRICAL REQUIREMENTS Hospital/Contractor has responsibility for completing all wiring and conduit runs detailed below BEFORE the product can be installed. ELECTRICAL REQUIREMENTS FOR STANDARD MOUNTING Check with Site Project Manager or BERCHTOLD Customer Service to determine whether Standard Mounting or Low Profile Mounting style is to be used. Standard Mounting Layout Diagram (see page 6 for details and description) REV. 2 700000006 Page 5

ELECTRICAL REQUIREMENTS PRE-INSTALLATION GUIDE STANDARD MOUNTING DETAILS (SEE PAGE 5 FOR LAYOUT DIAGRAM) 1. AC Wiring Wiring should be 3 wire, 14AWG min., and 600V. Wiring for lights should be flexible conduit exiting ceiling at the mounting ring and falling 18, min., below ceiling. CHROMOPHARE lights require a 120VAC, 50/60 Hz supply. BERCHTOLD recommends a separate 120VAC supply for each mounting ring. Each light head draws 2 Amps. 2. Conduit and boxes A standard 4X4 junction box should be installed in the wall for mounting of the light Wall Control. Front of box should be flush with the wall. BERCHTOLD suggests that this box be located approximately 53 off the floor. For each mounting ring a minimum 1 conduit, with finish grommets at each end, should be installed from the Wall Control junction box and terminated as close to the mounting ring as possible. Note: Conduit openings need to be easily accessible at both ends. 3. Optional Equipment (Contractors please check with customer to see if any options are to be installed.) ChromoVision camera system - Minimum 1 conduit, with finish grommets at each end, should be installed from the mounting ring to either a junction box used for mounting the camera control or the documentation console, per customer specification. Communication Interface Systems Conduit as required by the manufacturer of the interface unit. 700000006 REV. 2 Page 6

PRE-INSTALLATION GUIDE ELECTRICAL REQUIREMENTS LOW PROFILE MOUNTING LAYOUT DIAGRAM (See page 8 for details and description) REV. 2 700000006 Page 7

ELECTRICAL REQUIREMENTS PRE-INSTALLATION GUIDE LOW PROFILE MOUNTING DETAILS (SEE PAGE 7 FOR LAYOUT DIAGRAM) 1. SK Box Mounting SK box must be mounted within 10 of mounting ring and be easily accessible. An access panel close to the box mounting location is recommended. Single Light SK box weighs approximately 30 lbs.; double Light SK box weighs approximately 50 lbs. 2. AC Wiring (to input of SK box) AC supply should be 120VAC, 50/60 Hz. Wiring to be 3 wires, 14AWG min., 600V rated wire and run per local code to the SK box and terminated to the fused terminal block inside the SK box. Each light head draws 2 Amps. 3. DC Wiring (from SK Box to Mounting Ring) 12 AWG, 600 volt, 1 pair per light head and 1 ground wire per mounting ring. Wire is terminated to the non-fused terminal block inside the SK box. Wiring should run from output of SK box and fall 18, min., from ceiling at the mounting ring. 4. Conduit and boxes A standard 4X4 junction box should be installed in the wall for mounting of the light Wall Control. Front of box should be flush with the wall. BERCHTOLD suggests that this box be located approximately 53 off the floor. Minimum 1 conduit, with finish grommets at each end, should be installed from the Wall Control junction box and terminated at the SK box AC wiring As required by local code. DC wiring As required by local code. Note: Conduit openings need to be easily accessible at both ends. 5. Optional Equipment (Contractors please check with customer to see if any options are to be installed.) ChromoVision camera system - Minimum 1 conduit, with finish grommets at each end, should be installed from the SK box to either a junction box used for mounting the camera control or the documentation console, per customer specification. Note: Conduit openings need to be easily accessible at both ends. Communication Interface Systems Conduit as required by the manufacturer of the interface unit. 700000006 REV. 2 Page 8

PRE-INSTALLATION GUIDE ELECTRICAL REQUIREMENTS FLAT PANEL PRODUCTS (WITH AND WITHOUT LIGHTS) When included as part of a Light assembly: 1. AC wiring (In addition to Light AC wiring) Should be 3 wire, 14AWG min., and 600V. Conduit as required by local code. Wiring should exit ceiling at the mounting ring and fall 18, min., below ceiling. 2. Low voltage video cable conduit If conduit for low voltage cable is required by code then BERCHTOLD suggests 2 conduit to allow for the various types and quantities of video cabling that can be run. Conduit should run from the mounting ring to a destination determined by the customer. Note: Conduit openings need to be easily accessible at both ends. Stand Alone Flat Panel Products: 1. AC wiring Should be 3 wire, 14AWG min., 600V. Conduit as required by local code. Wiring should exit ceiling at the mounting ring and fall 18, min., below ceiling. 2. Low voltage video cable conduit If conduit for low voltage cable is required by code then BERCHTOLD suggests 2 conduit to allow for the various types and quantities of video cabling that can be run. Conduit should run from the mounting ring to a destination determined by the customer. Note: Conduit openings need to be easily accessible at both ends. REV. 2 700000006 Page 9

BOX DIMENSIONS PRE-INSTALLATION GUIDE WALL CONTROL BOX DIMENSIONS Back Panel (BERCHTOLD Dwg. 10-007-2030) 6.3 1.25 5.75 9.45 8.9 SK BOX DIMENSIONS SK Box for Single & Double Light Note: Triple light uses one double SK box and one single SK box. BERCHTOLD dwg. 71039, Hoffman Engineering No. A-14N126 REV. 2 700000006 Page 10

PRE-INSTALLATION GUIDE PUBLICATION HISTORY PRE-INSTALLATION GUIDE PUBLICATION HISTORY This publication describes the equipment as of the date of issue listed below. BERCHTOLD Corporation reserves the right to make changes in design or specifications at any time without notice. If you find any difference between the equipment you received and the components or assemblies described in this publication, contact BERCHTOLD Customer Service at 800-243-5135 for information. PUBLICATION HISTORY Revision Issue Date Revision 1 Original Issue: September 2002 (ECO 20149) Revision 2 November (ECO 21108) TELETOM is a Registered Trademark of BERCHTOLD Corporation. 2004 BERCHTOLD Corporation. All Rights Reserved REV. 2 700000006 Page 11

SAFE INNOVATIVE BERCHTOLD BERCHTOLD Corporation 1950 Hanahan Road Charleston, SC 29406 Phone: 843-569-6100 Phone: 800-243-5135 Fax: 843-569-6133 Manual No. 70-000-0006