C 9000 Polymer Quick-Acting Safety Coupler Range

Similar documents
Connectors for Optic Fibre Cable

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Spare parts list. Hydraulic compactor RC

Wet and dry vacuum cleaners NT 70/3

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

HEGA-Medical Product list V7.0

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

Wet and dry vacuum cleaners NT 70/3

The Safest Connections...

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

DUOPEX WATER MANUAL mm WM WMKA021044

Vacuum generation Content

OEM Sensors for HVAC manufacturers Heat recovery Chiller

KIT-UR-V. IST-KIT-UR-V Page 1 of 12 REVISIONS DOCUMENT LAYOUT MOUNTING INSTRUCTIONS AND OPERATING MANUAL

Boss Fittings KORD INDUSTRIAL INC

Quick closing oil drain valve QDV

Cold water HD 9/18-4 ST

Wet and dry vacuum cleaners NT 70/2 Adv

Multilux 4-Eclipse-Set

CR330 Owner s Manual

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

Catalogue. Washdown Equipment. brands products. Lutian Pressure Washers 1. Pressure Wash Lances and Nozzle Ranges 2. Einhell Wet and Dry Vacuums 4

HYDRAULIC CRIMPING TOOL HYDRAULIC PRESSHEAD

Air. Pressure. Motion. nnnnnnnn

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

HD 7/11-4 Cage Classic

Low air consumption vacuum generators

Installation and operating instructions. DK energy storage and DK energy buffer

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Installation Instructions Solar Controller Kit (Part Number AQ )

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

HD 5/12 C + Mobility. Accessory storage

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Tuzio Milano Towel Warmer

Settlement Agreement. Schedule 1: Covered Products

Pneumatic Pumps and Diaphragm Pumps. pneumato Pneumatic Oil Pumps. Pneumatic Double Diaphragm Pump DP-60

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

HDC Standard. Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points. Modular design. Intelligent pump control

Quality Heat Exchangers

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

Mikrotherm. Manual Radiator Valves With presetting

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Around the cable. Pressing and crimping.... convincing solutions

Thermostatic valves with radiator connection systems

DUOPEX WATER MANUAL mm

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

High Pressure Manways CODAP 2000 & PED 96/23/CE

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

U5300 Industrial Pressure Transducer

50 barg refrigeration dryers PoleStar Smart HP

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

RA15/6T & TB Conversion Valve

Partner Valve/High Quality Ball Valve LENO MSV-S

brands you trust. Pumps for hazardous materials Type GUP 3-1,5 & GP 20/10 Ex

F Cleaning In Place. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

Say heating. Say Herz. HERZ-Supply Engineering

an ISO 9001:2015 Registered Company

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

volumetric laboratory Calibrated to deliver (Ex) and the tolerances are according to DIN/ISO Class AS standards.

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

Quality Heat Exchangers

Standard Parts in Hygienic Design

Waste water ejection unit

Zurn Hydronics Prices Effective 1/01/06

CoolPro COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

Control valves for floor heating systems. Floor Heating Manifolds

Thermostatic valve bodies

M5800 Pressure Transducer with Rotatable Display

INSTALLATION AND OPERATING MANUAL

U5700 Submersible Liquid Level Pressure Transducer

NT 65/2 Eco Me. On-board storage. Integrated drain hose (oil-resistant)

Wet and dry vacuum cleaners NT 65/2 Eco

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Diesel Exhaust Fluid Compatible Products DEF

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

ROTARY SPRAY HEADS CATALOGUE

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

Tools for other contacts Tools for FOC contacts Crimping machine TK-M Crimping machine TC-C

Systems for central heating

COMPANY PROFILE

Cold water compact class HD 5/12 C

Flush individual room control for floor heating systems

DEVIATING VALVES ART K063

Transcription:

C 9000 Polymer Quick-Acting Safety Coupler Range C 9000 Polymer Quick-Acting Safety Couplers ISO B Profile 9401U Page -10 9405U Page -10 9414U Page -10 9410U Page -10 9421U Page -10 9416U Page -11 9440U Page -11 907U Page -11 906U Page -11 900U Page -12 9094U Page -12 European Profile 9401E Page -13 9414E Page -13 9410E Page -13 9421E Page -13 9416E Page -13 9440E Page -14 907E Page -14 906E Page -14 900E Page -14 9094E Page -14 ARO Profile 9401A Page -15 9405A Page -15 9414A Page -15 9410A Page -15 9421A Page -15 9416A Page -16 9440A Page -16 907A Page -16 906A Page -16 904A Page -16 900A Page - 9094A Page - -7

C 9000 Polymer Quick-Acting Safety Couplers This range of ergonomic polymer couplers has been designed for the safety of operators and machinery while giving very high energy efficiency performance. Available in three profile standards, it is perfectly suited for any type of installation. Product Advantages Safety & Reliability Prevents risk of whiplash Quick-acting vent allowing disconnection to be carried out in total safety Rotating sleeve to avoid risk of accidental disconnection Low connection/disconnection force even under pressure Polymer sleeve protects equipment from scratching Protective spiral over the tube prevents kinking Performance Very high flow and low pressure drop 100% leak-tested in production Date coding to guarantee quality and traceability Robust impact-resistant material Optimum energy efficiency Long-term reliability Easy-to-Use Immediate identification by clear marking on each model showing: profile of the compatible male probe type part number Compatible with male probes conforming to: ISO B profile European profile ARO profile Workshops Cleaning Blowing Pneumatics Air-Operated Tools Ring Main Circuits Packaging Applications Technical Characteristics Compatible Fluids Working Pressure Compressed air 0 to 16 bar Component Materials Body: ISO B profile: technical polymer or aluminium ARO profile: zamak European profile: technical polymer Adaptor: nickel-plated brass Working Temperature -20 C to +60 C Regulations DI: 97/23/EC (PED) DI: 2002/95/EC (RoHS), 2011/65/EC DI: 1907/2006 (REACH) ISO 4414 Pneumatic Fluid Power: General Rules Relating to Systems DIN EN 93 Safety Standard for Pneumatics Balls: stainless steel Spring: stainless steel Sleeve: technical polymer Silicone-free -

C 9000 Polymer Quick-Acting Safety Couplers C 9000 Technology and Flow Rates "Typical" quick-acting coupler Standard "poppet" technology Flow: 1400 Nl/min C 9000 quick-acting coupler "Optimal flow" technology Flow: 2400 Nl/min 2500 Flow (Nl/min) 2000 1500 1000 500 ARO ISO B6 EUROPEAN ISO B C 9000 Coupler Standard Couplers Operation Measurements carried out in accordance with ISO 635 at a pressure of 6 bar, pressure drop < 0.7 bar Operation Venting 1. 2. SAFETY ISO 4414 Disconnecting the probe Rotation, arrow 1: circuit vented on probe side. Rotation, arrow 2: probe disconnected from the body. Connecting the probe The sleeve does not need to be rotated to connect the probe. ISO B6 profile, recoil tubing (I.D. 6 mm, length 6 m) Venting time = 350 ms (transition from 6 bar to 0.2 bar) ISO B profile, PVC tubing (I.D. 10 mm, length 25 m) Venting time = 60 ms (transition from 6 bar to 0.2 bar) Even with longer lengths of tubing, the vent time of the C 9000 coupler can be less than 1 second. -9

ISO B Profile 9401U Coupler, Male BSPP Thread DN DN G1/4 2059401U0613 7.5 74 0.075 G3/ 2059401U06.5 21 76.5 0.095 G1/2 2059401U0621 10.5 25 0 0.115 G1/4 2059401U013 6.5 22 36.5 1.5 0.120 G3/ 2059401U0 7.5 22 36.5 2.5 0.133 G1/2 2059401U021 9 25 36.5 0.140 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min 9405U Coupler, Male BSPT Thread C F G L kg R1/4 2059405U0613 75 0.075 R3/ 2059405U06 19 76.5 0.095 R1/2 2059405U0621 22 1.5 0.110 R1/4 2059405U013 22 36.5 4 0.120 R3/ 2059405U0 22 36.5 4 0.120 R1/2 2059405U021 22 36.5 0.140 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min 9414U Coupler, Female BSPP Thread G1/4 2059414U0613 12 66.5 0.070 G3/ 2059414U06 12 22 72 0.05 G1/2 2059414U0621 15 27 7 0.115 G1/4 2059414U013 12 22 36.5 75 0.127 G3/ 2059414U0 12 22 36.5 75 0.144 G1/2 2059414U021 15 27 36.5 0 0.13 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min 9410U Coupler, LF 3000 Push-In Connection, Body Spiral Protection Spring 2059410U060 145 56 0.096 10 2059410U0610 145 56 0.00 10 2059410U010 36.5 155 63 0.5 12 2059410U012 36.5 165 63 0.162 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min 9421U -10 Coupler with Hosetail ØD F G L L1 kg 6 2059421U0606.5 26 0.070 2059421U060.5 26 0.070 10 2059421U0610.5 26 0.070 6 2059421U006 22 36.5 95 26 0.110 2059421U00 22 36.5 95 26 0.100 10 2059421U010 22 36.5 95 26 0.124 13 2059421U013 22 36.5 99 30 0.125 C 9000 Series ISO B (DN ): single shut-off flow = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off flow = 2400 Nl/min

ISO B Profile 9416U Coupler, Bulkhead Mountable, Female BSPP Thread C E F G K max L1 L2 ØT min kg G1/4 2059416U0613 12 22 6 12.5 6.5 1.5 0.105 G3/ 2059416U0 12 24 36.5 7 14.5 76 22.5 0.150 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min DN DN 9440U Y Coupler, Female BSPP Thread C E F F1 G H H1 kg G3/ 2059440U06 11.5 19 20 70 16 0.207 G1/2 2059440U021 14 22 25 36.5 0 19 0.352 C 9000 Series ISO B (DN ): single shut-off = 1250 Nl/min C 9000 Series ISO B (DN ): single shut-off = 2400 Nl/min 907U Probe, Straight-Through, Male BSPP Thread, technical polymer G1/4 205907U0613 9 3 24 0.025 G3/ 205907U06 9 19 3 24 0.032 G1/2 205907U0621 12 22 42 24 0.04 G1/4 205907U013 9 3 24 0.030 G3/ 205907U0 9 19 39 24 0.036 G1/2 205907U021 12 22 42 24 0.05 906U Probe, Straight-Through, Female BSPP Thread G1/4 2059062313 9 36 24 0.025 G3/ 20590623 9 19 36 24 0.025 G1/2 2059062321 12 24 39 24 0.039 E 906U Probe, Straight-Through, Female BSPP Thread.5 G1/4 2059063013 10 40 2 0.032 G3/ 20590630 10 19 42 2 0.035 G1/2 2059063021 12 24 43 2 0.046 30 Series probe (DN.5) compatible with ISO B series C 9000 couplers (DN ) E -11

ISO B Profile 900U DN DN Probe, Straight-Through, LF 3000 Push-In Connection, with Spiral Protection Spring, NBR 205900U060 24 112 24 0.052 10 205900U0610 24 112 24 0.044 10 205900U010 24 114 26 0.095 12 205900U012 29.5 125 26 0.096 9094U Probe, Straight-Through, with Hosetail ØD F L L1 L2 kg 6 2059094U0606 14 51 24 25 0.016 2059094U060 14 51 27 25 0.0 10 2059094U0610 14 51 24 25 0.01 2059094U00 51 24 25 0.027 10 2059094U010 51 27 25 0.02 13 2059094U013 51 24 25 0.031-12

European Profile 9401E Coupler, Male BSPP Thread DN G1/4 G3/ 2059401E0713 2059401E07 6.5 22 7.5 22 36.5 36.5 0 1 0.124 0.122 G1/2 2059401E0721 9 25 36.5 3.5 0.136 9414E Coupler, Female BSPP Thread G1/4 2059414E0713 12 22 36.5 73 0.11 G3/ 2059414E07 12 22 36.5 73 0.109 G1/2 2059414E0721 15 27 36.5 7 0.130 9410E Coupler, LF 3000 Push-In Connection, with Spiral Protection Spring 10 2059410E0710 36.5 151 63 0.5 12 2059410E0712 36.5 151 63 0.10 9421E Coupler with Hosetail ØD F G L L1 kg 10 13 2059421E070 2059421E0710 2059421E0713 22 22 22 36.5 36.5 36.5 93 93 97 26 26 30 0.113 0.114 0.119 9416E Coupler, Bulkhead Mountable, Female BSPP Thread C E F G K max L1 L2 ØT min kg G3/ 2059416E07 12 24 36.5 7 14.5 74 22.5 0.153-13

European Profile 9440E Y Coupler, Female BSPP Thread DN C E F F1 G H H1 kg G1/2 2059440E0721 14 25 25 36.5 7 19 0.335 907E Probe, Straight-Through, Male BSPP Thread,technical polymer G1/4 205907E0713 9 14 34 20 0.01 G3/ 205907E07 9 34 20 0.025 G1/2 205907E0721 12 22 3 20 0.04 906E Probe, Straight-Through, Female BSPP Thread 7.4 G1/ 2059062510 7 14 32 20 0.015 G1/4 2059062513 9 3.5 20 0.027 G3/ G1/2 20590625 2059062521 9 12 19 24 33 36 20 20 0.027 0.050 E 900E Probe, Straight-Through, LF 3000 Push-In Connection, with Spiral Protection Spring, NBR 10 205900E0710 24 114 20 0.102 12 205900E0712 29.5 125 20 0.0 9094E Probe, Straight-Through, with Hosetail ØD F L L1 L2 kg 2059094E070 4 20 25 0.014 10 2059094E0710 4 20 25 0.016 13 2059094E0713 4 20 25 0.019-14

ARO Profile 9401A Coupler, Male BSPP Thread DN G1/4 G3/ G1/2 2059401A0613 2059401A06 2059401A0621 6.5 9 9 21 25 70.5 73.5 70.5 0.105 0.123 0.150 9405A Coupler, Male BSPT Thread C F G L kg R1/4 R3/ R1/2 2059405A0613 2059405A06 2059405A0621 19 22 73 74.5 79.5 0.105 0.110 0.140 9414A Coupler, Female BSPP Thread G1/4 G3/ G1/2 2059414A0613 2059414A06 2059414A0621 12 12 15 22 27 64.5 70 76 0.095 0.115 0.145 9410A Coupler, LF 3000 Push-In Connection, with Spiral Protection Spring 2059410A060 143 54 0.140 10 2059410A0610 143 54 0.5 9421A Coupler with Hosetail ØD F G L L1 kg 6 10 2059421A0606 2059421A060 2059421A0610 6.5 6.5 6.5 26 26 26 0.110 0.100 0.100-15

ARO Profile 9416A Coupler, Bulkhead Mountable, Female BSPP Thread DN C E F G K L1 L2 ØT kg G1/4 2059416A0613 12 22 6 12.5 66.5 1.5 0.135 9440A Y Coupler, Female BSPP Thread C E F F1 G H H1 kg G3/ 2059440A06 11.5 19 20 6 16 0.263 907A Probe, Straight-Through, Male BSPP Thread, technical polymer G1/4 205907A0613 9 36 22 0.020 G3/ 205907A06 9 19 36 22 0.024 G1/2 205907A0621 12 24 40 22 0.039 906A Probe, Straight-Through, Female BSPP Thread G1/4 2059062213 9 3 22 0.024 G3/ 20590622 10 19 3 22 0.023 G1/2 2059062221 12 24 3 22 0.039 E 904A Probe, Straight-Through, Male BSPT Thread C F L L1 kg R1/4 2059042213 14 40.5 22 0.020 R3/ 20590422 40.5 22 0.031 R1/2 2059042221 22 46 22 0.04-16

ARO Profile 900A DN Probe, Straight-Through, LF 3000 Push-In Connection, with Spiral Protection Spring, NBR 205900A060 24 11 22 0.02 10 205900A0610 24 11 22 0.027 9094A Probe, Straight-Through, with Hosetail ØD F L L1 L2 kg 6 2059094A0606 14 4.5 22 25 0.012 2059094A060 14 4.5 22 25 0.014 10 2059094A0610 14 4.5 22 25 0.016 -