Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Similar documents
Push Button Electronic Timer. 31VETR Series. Installation Instructions

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Universal Dimmer E450UD Series. Installation Instructions

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Mains Power Filter 970MF10 970MF20. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Dimmer / Fan Controller Installation Instructions

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

Motion sensors for every application

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Universal Clamp Meter

Consumer Switchboards 4CS & 4FCS. Installation Instructions

Airflow. Add a little Sunshine to your bathroom

Get connected with Xantrex Grid-Tie Inverters

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Ceiling Mounted Ducted Exhaust Fan Kit

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

C-Bus Four Channel Analogue Output Unit Installation Instructions

SMART HOME LIGHTING CONTROL C LIPSAL

Intercom Systems Video Intercoms

Airflow. The coolest way to save energy

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

C-Bus Reflection Range Installation Instructions

Energy cost saving made easy!

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

C-Bus Application Note. Function Rooms and Ballrooms. Overview

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

C-Bus Four Channel General Input Unit Installation Instructions

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

60cm Built-In Ceramic Cooktop

6.5L SLOW COOKER INSTRUCTION MANUAL

compact office 24V compact office 24V Lux

Lighting and Energy Control

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Lighting & Energy Efficiency

TRAVELMATE. Instruction Manual

OPERATING INSTRUCTIONS

compact office 24V compact office 24V Lux

Model pictured: RPA3CI6SS/WH

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Operation, Maintenance and Installation Manual

Lighting and Energy Efficiency

Flexibility from floor to ceiling

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Wall Fan. 3 Speed, 40cm MWF40

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Wireless Electricity Monitor. User Manual REGISTERED PATENT

Installation and Operations Manual

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Drying Cabinet With Timer

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Integrated PIR detectors

OPERATING INSTRUCTIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller or Manual Thermostat)

USER MANUAL. Adventure Kings 50L Refrigerator

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

TRAVELMATE FRIDGE FREEZER Instruction Manual

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

MTRA-FSP Level Control Relay. Installation & Operation Manual

60cm Built In Induction Cooktop

Installation Instructions

PresenceLight 180 PresenceLight 360

Evaporative Cooler. 8 Litre MEC1R

PRODUCT MANUAL. The intelligent, energy saving solution

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

SENSA MRE DDM MR

Transcription:

Push Button Electronic Timer 31VETR3 Series Installation Instructions

Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warning... 3 5.0 Timer Control... 4 5.1 Push Button Control... 4 5.2 Indicator Function... 4 5.3 Relay Output... 4 5.4 Remote Operation... 4 6.0 Wiring Diagrams... 4 6.1 Local Operation... 4 6.2 Remote Operation... 4 7.0 Timer Settings... 5 7.1 Timer Adjustment Settings... 5 7.2 Timer Example 1... 6 7.3 Timer Example 2... 6 8.0 Electrical Specifications... 7 9.0 Warranty Statement... 8 Copyright Notice The concepts, products and designs described in this document are the subject of international patents, and protected by international law. Copyright Clipsal Australia Pty Ltd. All rights reserved. Trademarks Clipsal is a registered trademark of Clipsal Australia Pty Ltd. All other logos and trademarks are the property of their respective owners. Disclaimer Clipsal Australia Pty Ltd reserves the right to change specifications or designs described in this manual without notice and without obligation. 2 of 8 Copyright Clipsal Australia Pty Ltd

1.0 Product Range 31VETR3 2031VETR3 Electronic Timer, Push Button, 220-240V, 50Hz, 10AX (Standard Range) Electronic Timer, Push Button, 220-240V, 50Hz, 10AX (2000 Series) * Please note that these products are also available in other configurations and in a wide range of colours. For further information, please contact your nearest Clipsal Sales Representative. 2.0 Description The Clipsal 31VETR3 Series is a range of high quality, three-wire, push button electronic time delay switches with remote control and override off facilities. The product is designed to control lighting and other loads to prevent them from being left on unnecessarily. Significant energy savings can result when used for staircase, hallway, classroom and similar applications. The unit has a powerful 10AX switching capability, and is suitable for a wide range of load types, including incandescent, inductive and fluorescent loads. 3.0 Features State of the art microprocessor design Time setting selection from 10 seconds to 15 hours Highly accurate digital timing (±0.5%) Micro switch configurable indicator function: Indicator On when contact closed; OR Indicator On when contact open. Micro switch selectable modes: Contact open during timing (Normally Closed); OR Contact closed during timing (Normally Open). Remote control capability, using remote wired momentary action switches 10AX switch load rating. Suitable for a wide range of load types Incandescent (tungsten filament) lamps 240V Halogen / Dichroic Lamps Low voltage downlights using electronic transformers Low voltage downlights using iron-core transformers Fluorescent Lighting Loads Compact Fluorescent Light Loads LED Lighting Loads Small Motor Loads (limited to 2A) Available in a range of plate styles and colour variants Suitable for new installations or retro-fit applications Complies with Australian Standards 4.0 Important Warning It is illegal for persons other than an appropriately licenced electrical contractor or other persons authorised by legislation to work on the fixed wiring of any electrical installation. Penalties for conviction are severe! Copyright Clipsal Australia Pty Ltd 3 of 8

5.0 Timer Control 5.1 Push Button Control The built in push button has the following functions: Pressing the button when the timer is passive will initiate timing and set the load, and indicator, to the active state according to the configuration switch settings. Pressing the button during timing will cancel timing and set the load, and indicator, to the passive state according to the configuration switch settings. To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions. 5.2 Indicator Function The built in light indicator is used to indicate the status of the load. It can be configured by the micro switch on the rear of the unit to be on when contact is either open or closed. 5.3 Relay Output The relay contact can be configured by the appropriate micro switch on the rear of the unit to be closed during timing (Normally Open) or open during timing (Normally Closed). The contact is always open when the supply is turned off regardless of the configuration. 5.4 Remote Operation The unit can respond to one or more remote wired momentary switch inputs. The unit will respond to the remote switch inputs in exactly the same way as if pressing the button on the front of the unit. 6.0 Wiring Diagrams 6.1 Local Operation For most normal applications, where operation from the local push button is required only, the timer is wired as shown in the figure below. Line Neutral 31VETR3 Line Neutral Load Remote Load 6.2 Remote Operation Additional switches can be installed in parallel, allowing the timer to be activated from one or more remote locations. Line Neutral 31VETR3 Neutral Load Load Remote NOTE: The remote switch wiring must be rated for 240V a.c. The sum of cable lengths used to connect the remote switches must not exceed 100m. Remote switches MUST be Normally Open momentary operation type switches. Line Remote Switches Momentary Action 4 of 8 Copyright Clipsal Australia Pty Ltd

7.0 Timer Settings WARNING: For safety reasons the setup should be performed with the timer isolated from the mains supply. 7.1 Timer Adjustment Settings The timer setting is achieved by the use of an 8 way micro switch. The switch is accessible from the back of the unit through a window in the enclosure. The functions of the individual switches are presented on the following figure: Timer Micro Switches Indicator State Time Range Time Setting Indicator State when Contact Closed Time Range 1 to 4 determines Range Multiplier (see table) Time setting 0 to 15 determined by totalling values of switches set to ON Time Delay Setting The Time Setting is determined by totalling the values of each of the time setting switches that are set to ON (any combination of 1, 2, 4 and 8). The Time Range is determined by the positions of the time range switches R1 and R2 (refer to Time Ranges table below). The Time Delay is then calculated by the Time Setting multiplied by the Range Multiplier. Time Delay = Time Setting x Range Multiplier Time Ranges The following four Time Ranges are available: Time Delay Time Range R1 R2 Range Multiplier Minimum Time Setting switches 1,2,4,8 Maximum Time Setting switches 1,2,4,8 1 10 seconds 10 seconds 2 min & 30 sec 2 ON 1 minute 1 minute 15 minutes 3 ON 10 minutes 10 minutes 2 hr & 30 min 4 ON ON 1 hour 1 hour 15 hour Contact Function Contact Function - Normally Open or Normally Closed Setting NO NC Meaning Relay contact is Normally Open. Contact will CLOSE during timing operation. Relay contact is Normally Closed. Contact will OPEN during timing operation. Indicator State Setting ON Meaning Indicator ON when contact is CLOSED. Indicator when contact OPEN. Indicator when contact is CLOSED. Indicator ON when contact OPEN. Copyright Clipsal Australia Pty Ltd 5 of 8

7.2 Timer Example 1 Required Time Delay is 6 minutes. Contact must Close during timing. Indicator is ON when contact is Closed. Time Delay Setting Initially set all Time Setting switches to the position. Select the first timing range in the range selection table for which Maximum Setting is higher than the required time delay. The Time Range table shows that Time Range 2 (which has a 15 minute maximum setting) is the most appropriate time range. Select Time Range 2 by setting switch R1 to ON and R2 to. The selected Range Multiplier is now 1 minute. The highest time value for an individual switch lower than 6 is 4. Set the micro switch 4 to ON. Remaining time required is 6-4 = 2. Set the micro switch 2 to ON. Total amount of time set is (4 + 2) x (1 minute) = 6 minutes. Contact Function Setting Set the Contact Function micro switch to NO position to select the Normally Open contact function (contact closes during timing). Indicator Function Setting Set the Indicator State micro switch to the ON position so that the indicator is ON when the contact is closed. Indicator Contact State when Function Contact Closed Time Range Time Setting NO ON R1 R2 8 4 2 1 ON NC 7.3 Timer Example 2 Required Time Delay is 10 hours. Required Contact Function is Normally Closed. Indicator is required to be ON when contact is Open. Indicator Contact State when Function Contact Closed Time Range Time Setting NO ON R1 R2 8 4 2 1 ON NC 6 of 8 Copyright Clipsal Australia Pty Ltd

8.0 Electrical Specifications Parameter Nominal Operating Voltage Nominal Operating Frequency Maximum Load Current Minimum Load Current Compatible Loads Value 220-240V 50Hz 10AX 0mA Compact Fluorescent Lamps LED Lighting Incandescent lamps Halogen 240V lamps Low voltage lighting with electronic transformers Low voltage lighting with iron-core transformers Fluorescent Lighting Small Motor Loads (Maximum 2A) Timer Range 10 seconds 15 hours Timer Accuracy ± 0.5% Power-Up Status Operating Temperature Range 0 to 40 C Operating Humidity Range 10 to 90% R.H. Mounting Centres 84mm Australian Pattern Plate Safety Compliances AS/NZS3100, AS/NZS3133 EMC Emission Compliance AS/NZS CISPR15 Specifications Typical @ 240V, 25 o C No User Serviceable Parts Inside WARNING: Operation outside of these specifications may result in unexpected behaviour, or even product failure. Timer accuracy may be affected by voltage, temperature and humidity. Warranty may be voided when controlling any incompatible load types as determined by Clipsal Australia. Copyright Clipsal Australia Pty Ltd 7 of 8

9.0 Warranty Statement 1. The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to the Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2. The warrantor is Clipsal Australia Pty Ltd of 33-37 Port Wakefield Road, Gepps Cross, South Australia 5094. With registered offices in all Australian states. 3. This Clipsal product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. 4. Clipsal Australia Pty Ltd reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 5. This warranty is expressly subject to the Clipsal product being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. 6. All costs of a claim shall be met by Clipsal Australia Pty Ltd, however should the product that is the subject of the claim be found to be in good working order all such costs shall be met by the claimant. 7. When making a claim the consumer shall forward the Clipsal product to the nearest office of Clipsal Australia Pty Ltd with adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. Clipsal Australia Pty Ltd clipsal.com A member of Schneider Electric Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Clipsal Australia Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Clipsal Australia Pty Ltd. The identified trademarks and copyrights are the property of Clipsal Australia Pty Ltd unless otherwise noted. F1394/04 CLIPCOM 22059 August 2010