CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Similar documents
Halton CHB Active chilled beam with boost function for bulkhead installation

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Halton Rex 600 Basic R6B - Active chilled beam

Halton Rex for Vario R6O - Variable air volume chilled beam

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

HOTEL CHILLED BEAM IQ STAR SILENCIA

Halton CPT Passive Chilled Beam

CHILLED BEAM CASSETTE IQ STAR LYRA

Units for suspended ceilings

KLIMA Active Chilled Beams

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Units for suspended cei lings

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Passive chilled beams

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

iq Star LYRA II chilled beam cassette

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Polaris-I-60. active chilled beam. the future of space conditioning

LØV-R. Svalbard-H. Chilled beam for corner installation between wall and ceiling

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Installation, Operation & Maintenance Instructions Document Ref:

Installation, Operation and Maintenance Instructions Document Ref:

Primo Hotel. General. Indoor climate units for hotel rooms

Installation, Operation and Maintenance Instructions Document Ref:

Panther Fan Coil Units

CONDOR. Supply air ceiling QUICK FACTS

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Cooling Strip Model SPB

Fan heater SWT Ceiling mounted fan heater with water heat

42AM. Air heaters PRODUCT SELECTION DATA

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

iq Star LYRA II chilled beam cassette

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Ceiling swirl diffusers

CASSETTE UNIT. Comfort Circle

Ceiling swirl diffusers

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

FAN COIL UNITS. The optimal solution for limited space

Metropolitan high output natural and powered trench heaters

Panther Fan Coil Unit

PARAGONTM Comfort module for hotel rooms and hospital wards

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

QZHW Fan Coil Unit. Key features. Specifications

Ceiling diffusers. Type DLQL

LOW STATIC HYDRONIC DUCTED UNIT

Blower-YEFB-020-3R-1maxVel

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

Fan Coil Unit CULTRA

Orion-Opus LØV-R with Sirius

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

QTS SELECTION TECHNICAL BOOKLET

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

LindabArchitect. Supply air beam. lindab we simplify construction

Ocelot Fan Coil Units

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Remote Air Cooled Condensers C2 Series

TopVent Design Handbook

Use. Worth noting. Key figures. Installation. linx industries chilled beams

Technology for life. Unit heater LH

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

Orion-PTV LØV-R with Sirius

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Orion-LØV LØV-R with Sirius

LindabCapella. Supply air beam

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

PARASOL EX. Suspended comfort modules QUICK FACTS

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

QZB "Standard" comfort fan coil

KOMFORT EC DB Suspended heat recovery air handling units

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

Active Chilled Beams. Technical Data Concealed Ceiling Mounted Model With Vertical Coil and Integral Drain Pan

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

installation, operation & Maintenance manual acb ceiling-mounted cassette models

CAW Ceiling-mounted fan heaters for hot water

PARAGON. Compact comfort module. Key figures

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

Transcription:

Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal comfort and silent conditions. Ideal also for other buildings where high indoor environmental quality and individual room control are appreciated. Enhanced life-cycle performance: - Energy-efficient solution with low air and water flow rates in both cooling and heating modes. - Suitable system for use with free energy sources and heat pumps. - Low-cost maintenance due to simple and hygienic principle of operation. Operates as a noncondensating dry system with minimal use of mechanical parts: no fan, no mechanical filters, no condensation tray, and no drainage tubing. Efficient ordering and installation: - Ability to change the position of the primary air inlet spigot and waterside pipe connections on-site to match the installation conditions. - Compact design, from 1000 mm (width) x 925 mm (length) x 250 mm (height), suitable for both renovation projects and new construction. Product Options and Accessories Model with combined cooling and heating coil Option for different supply air grilles Integrated control valves and actuators 1

QUICK SELECTION Pa 143 191 239 287 334 382 qv l/s 15 20 25 30 35 40 m 3 /h 54 72 90 108 126 144 Leff 800 Pw 425 602 576 700 649 745 NZ/DPtot A/50 A/89 B/71 B/102 C/79 C/103 Ld 4,4 6,0 6,2 7,4 7,2 8,0 Leff Pa Pw NZ DPtot Ld Effective length, length of cooling coil, mm Supply air capacity, W Coil capacity, W Nozzle type Chilled beam chamber pressure, Pa Distance where supply air jet detaches from the ceiling, m Room temperature (Tr) = 24 C Chilled water inlet temperature (Twin) = 14 C Chilled water outlet temperature (Twout) = 17 C Supply air temperature (Ta) = 16 C A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, db(a) red 10m 2 sab < 30 db(a) MATERIAL AND FINISHING PART MATERIAL FINISHING NOTE Return air grille Pre-painted galvanised steel Polyester-painted White RAL 9010/ 20 % gloss Special colours available Supply air grille G = A Aluminium White RAL 9010 / 50% gloss Special colours available Supply air grille G = B Steel White RAL 9010 / 50% gloss Special colours available Casing Galvanised steel Supply air plenum Galvanised steel Brackets Galvanised steel Coil pipes Copper Coil fins Aluminium Cooling / heating water pipe connections are Cu15/ Cu12 with wall thickness of 1.0 mm, fulfilling European standard EN 1057:1996. The maximum operating pressure for chilled/hot water pipework is 1.0 MPa. The supply air duct connection diameter is 125 mm. 2

Delivered factory fitted or loose. If control valves are factory fitted in the factory, the location of the pipe connections cannot 845 be changed on the site. 845 30 176 250 176 250 Aluminium air supply air grille Steel air supply air grille PRODUCT OPTIONS AND ACCESSORIES ACCESSORY CODE DESCRIPTION NOTE Supply air grille G = A Aluminium grille with 7 fixed horizontal front vanes for horizontal air supply. Fixed front vanes, stable throw pattern with vertical 15 deflection. Aluminium construction with elegant look. Supply air grille G = B Steel grille with 9 horizontal front vanes for horizontal air supply. Adjustable horizontal front vanes max 15. Robust steel construction. Combined cooling and heating coil Control valve Valve actuator As standard, supply and return air grilles are supplied in the same colour. Grilles also can be delivered in different colours on request. If another grille is needed for the space, Halton recommends to use Halton AWE that has similar outlook. As standard, supply and return air grilles are supplied in the same colour. Grilles also can be delivered in different colours on request. If another grille is needed for the space, Halton recommends to use Halton WTS that has similar outlook. TC = H H = coil with hot water circulation. Copper water pipe connections are Ø 15 mm (cooling) and Ø 10 mm (heating) CV = see product code VM = see product code Valves with adjustable kvs value (Danfoss RA-C dn15) or with max flow limit function (Danfoss AB-QM dn 10 in heating and Danfoss AB-QM dn 15 in cooling). Thermal on/off actuators (230 VAC NC or 24 VAC NC for both valve types. 30 Delivered factory-fitted or loose. Cable length 1.2m. DIMENSIONS AND WEIGHT 826 1000 8 390 925 60 6 826 1000 8 235 10 45 115 45 180 45 285 305 80 500 925 Weight of the beam: 30 kg (excluding water) 390 60 235 10 45 285 115 45 180 45 305 6 3

Three different nozzle sizes are available to enable various supply air flow rates. The nozzle plates are inter-changeable to account for layout or room changes. Waterside cooling and heating capacity control The chilled beam can be equipped in the factory with either a standard control valve or a combination control valve. Function The CHH unit is an active chilled beam for bulkhead installation. The primary supply air enters the plenum of the active chilled beam, from where it is diffused into the room through nozzles and a supply grille on the front side of the beam. The supply air nozzle jets efficiently induce ambient room air through the lower return air grille and the heat exchanger, where it is either cooled or heated. The combined air jet is directed along the ceiling surface. Controls may include either a standard control valve or a combination control valve. Both control valves are operated with a thermal actuator, and the water flow rate of the control valve is based on room air temperature. The standard control valve has an adjustable kvs value. The combination control valve has an adjustable nominal water flow rate and there is a pressure difference measurement across the control valve in order to ensure that enough pressure difference (min.: 16 kpa) is available to achieve the adjusted water flow rate and the automatic balancing in use. See Document-section for more information. Installation The CHH unit is suitable for bulkhead and suspended ceiling installation. The chilled beam ceiling brackets can be fixed directly to the ceiling surface or suspended using threaded drop rods (8 mm). The recommended maximum distance of the supply air grille from the ceiling is 200 mm. The return air grille has a 40-mm telescopic connection and the supply air grille a 200-mm telescopic connection. Install the main pipelines of the cooling and heating water loops above the level of the chilled beams to allow venting of the pipework. If unit is delivered with factory fitted valves, there must be c. 80mm space above unit. 0-40 0-200 4

Servicing CODE DESCRIPTION 1 Return air grille 2 Supply air grille 3 Supply air connection 4 Chilled water pipe connections 5 Heating water pipe connections Open the return air grille of the chilled beam. Clean the finned coils of the heat exchanger using a vacuum cleaner, taking care not to damage the finned coils. Clean the return and supply air grilles with a damp cloth. Check at regular intervals that the actuators and water flow control valves are working. Adjustment Cooling The recommended cooling water mass flow rate is 0.02 0.10 kg/s, resulting in a temperature rise of 1 4 C in the heat exchanger. To avoid condensation, the recommended inlet water temperature of the heat exchanger is 14 16 C. Heating The recommended heating water mass flow rate is 0.01 0.04 kg/s, resulting in a temperature drop of 5 15 C in the heat exchanger. The recommended temperature of the inlet water for the heat exchanger is 35 45 C. Balancing and control of water flow rates Balance the water flow rates of the chilled beam with the standard control valve by selecting the design kvs value in the valve body. When using an automatically balancing combination valve, set the design water flow rate in the valve body and verify the pressure difference (min.: 16 kpa) across the valve. Regulating the water mass flow rate controls the cooling and heating capacity of the chilled beam. Adjustment of supply airflow rate Each chilled beam is equipped with a measurement tap for static pressure measurement, which enables fast and accurate measurement of the supply air flow rate through the beam. The air flow rate is calculated using the formula below. q v = k * p m Nozzle k A 2,11 B 3,03 C 4,15 5

CHH selection tables Cooling: nozzle A Pa 143 162 182 201 220 239 qv l/s 15 17 19 21 23 25 Leff m 3 /h 54 61 68 76 83 90 800 DPtot 50 65 81 99 118 140 Pw 425 498 568 633 698 759 Pt 568 660 750 834 918 997 LpA 16 18 20 22 23 25 Ld 4,4 5,0 5,6 6,2 6,8 7,4 Heating: nozzle A Recommended maximum heating capacity in 80-120Pa pressure level is 500W. Cooling: nozzle B Pa 220 239 258 277 296 315 qv l/s 23 25 27 29 31 33 Leff m 3 /h 83 90 97 104 112 119 800 DPtot 60 71 83 96 109 124 Pw 523 576 627 676 723 770 Pt 743 815 885 953 1019 1086 LpA 19 21 23 24 26 27 Ld 5,8 6,2 6,8 7,2 7,6 8,0 Heating: nozzle B Recommended maximum heating capacity in 80-120Pa pressure level is 600W. Cooling: nozzle C Pa 296 315 334 354 373 qv l/s 31 33 35 37 39 Leff m 3 /h 112 119 126 133 140 800 DPtot 62 70 79 88 98 Pw 568 609 649 688 727 Pt 864 925 983 1041 1100 LpA 25 26 27 28 29 Ld 6,4 7,0 7,2 7,6 8,0 Heating: nozzle C Recommended maximum heating capacity in 80-120Pa pressure level is 750W. Notations of the selection tables LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. Leff Pa DPtot Pw Pt LpA Ld Effective length, length of cooling coil, mm Supply air cooling capacity, W Chilled beam chamber pressure, Pa Coil capacity, W Total capasity, W A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, db(a) red 10m 2 - sab Distance from the supply unit, at which air jet detaches from ceiling, m Room temperature (Tr) = 24 C Chilled water inlet temperature (Twin) = 14 C Chilled water outlet temperature (Twout) = 17 C Supply air temperature (Ta) = 16 C 6

Suggested specifications The Halton CHH unit is an active chilled beam for bulkhead and enclosed installation with return and supply air grilles. E = Location of supply air connection R Right L Left M Middle The return air and supply air grilles shall be openable and removable for maintenance. The return air grille has a 40-mm telescopic connection and the supply air grille a 200-mm telescopic connection. The active chilled beam shall be 1000 mm wide, 925 mm in length, and 250 mm high, with an inlet duct diameter of 125 mm. The inlet duct connection shall be changeable and able to be located at the right, left, or middle of the supply air plenum. The heat exchanger of the beam shall be oriented such that the water connections may be located on either the right or left side of the beam. All pipes shall be manufactured from copper, connection pipes with a wall thickness of 1.0 mm. The fins of the heat exchanger shall be manufactured from aluminium. The heat exchanger shall be factory pressure-tested. The maximum operating pressure of pipework shall be 1.0 MPa. Each active chilled beam shall be protected by a removable plastic coating and individually packed in a plastic bag. Duct connection and pipe ends shall be sealed during transit. Each chilled beam shall be identifiable by a serial number printed on a label attached to the active chilled beam. Product code CHH/S-E-K-G S = Nozzle type A Nozzle 5 B Nozzle 6 C Nozzle 7 K = Location of pipe connections R Right L Left G = Type of air supply air grille A Aluminium B Steel Specifics and accessories TC = Cooling / heating functions (coil type) C Cooling H Cooling and heating CO = Colour of grilles W White X Special colour CV = Control valves N Not assigned A1 Adjustable kvs (Danfoss RA-C dn15); factory fitted A2 Adjustable kvs (Danfoss RA-C dn15); loose A3 Max flow limit (Danfoss AB-QM dn 10 (heating) and dn15 (cooling); factory fitted A4 Max flow limit (Danfoss AB-QM dn 10 (heating) and dn15 (cooling); loose VM = Valve actuator(s) N Not assigned A1 24 V A2 230 V Code example CHH/A-M-R-A, TC=C, CO=W, CV=N, VM=N 7