ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler Heads Revised

Similar documents
Non-Storage / Special Protection / Storage Sprinklers

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Norminal Sprinkler Temperature Rating

SECTION SPRINKLER SYSTEMS

Norminal Sprinkler Temperature Rating

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

standard response Fusible Link Upright sprinkler VK204 (K8.0)

micromatic standard response Upright sprinkler VK100 (K5.6)

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

B. Section Identification for Fire Suppression Piping and Equipment.

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

TECHNICAL DATA NOTICE

SENJU SPRINKLER CO., LTD.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

quick response horizontal sidewall sprinkler vk360 (K8.0)

esfr dry pendent sprinkler Vk501 (k14.0)

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

micromatic Standard response Horizontal Sidewall sprinkler

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

esfr dry pendent sprinkler Vk502 (k14.0)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA OBSOLETE

Microfast quick response Fusible element hsw sprinkler

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

esfr pendent sprinkler vk510 (k25.2)

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

esfr pendent sprinkler vk510 (k25.2)

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

TECHNICAL DATA. Page 1 of 6

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

standard response elo upright sprinkler

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

micromatic Standard response Horizontal Sidewall sprinkler

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Objective 1: Describe fire alarm systems.

Storage Sprinkler U.S. Quick Reference Guide

Automatic Sprinklers

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

Data Sheet 4.16 Issue D

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Data Sheet 4.24 Issue F

STORAGE FIRE PROTECTION SPRINKLERS

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

SENJU SPRINKLER CO., LTD.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

standard response fusible link sidewall sprinkler VK112 (K5.6)

Quick response concealed horizontal sidewall sprinkler VK481

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

microfast sr/qr extended coverage pendent sprinkler

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

The Effect of Large Orifice Sprinklers on High-Challenge Fires

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

Model F1FR Series Quick Response Standard Spray

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

Equipment: PowerPoint Presentation: Sprinkler Systems: Review and Response Considerations

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

Transcription:

Engine Module Page 1 of 5 SPRINKLER HEADS Types of Sprinkler Heads There are many different types of sprinkler heads utilized in fire protection systems. Most are equipped with a thermal detector that keeps the head from releasing water until it is fused or melted by heat. When the thermal detector reacts to the heat, a cap is released from the nozzle of the sprinkler head and water, or air followed by water is released, depending on the type of sprinkler system. It is important to note that in Deluge systems sprinkler heads are permanently open and operate automatically once a fire detection device has perceived the heat and opened the deluge valve (see Deluge Sprinkler Systems). Each sprinkler head is equipped with a deflector, which directs the water stream released from the nozzle (from 3/16" to 3/4" in diameter) into a spray, which will more efficiently contain the fire. The four most common types of release mechanisms include: Fusible Links Soldered Pellets Liquid Bulbs Quick Response Fusible Links Each type of thermal detector reacts in a similar manner. The heat source will destroy some critical component of the detector, which allows the cap to release from the nozzle. Fusible Links Fusible links incorporate two levers, which are positioned between the nozzle cap and the outer sprinkler head frame to which the deflector is attached. The levers are then attached to each other via a fusible plate. Heat acts upon the plate, fusing it, and therefore destroying support to the levers. Once the link has fused, water (or air) pressure pushes the levers and nozzle cap out of the way.

Engine Module Page 2 of 5 Soldered Pellet This type of detector employs a small pellet of solder, which holds a small plunger in place against the nozzle cap. At a predetermined temperature, the pellet will melt and allow the plunger to slide away from the cap, which is then pushed away from the nozzle by water or air pressure. Liquid Bulb A small glass bulb is placed between the frame and cap of the sprinkler head. The bulb is partially filled with a liquid, which will expand when heated. The expansion of the liquid will eventually shatter the bulb releasing the nozzle cap. The amount of liquid in the bulb will determine the temperature required to open the head. Quick Response Links These are similar to fusible links with a much quicker reaction time. This is facilitated by a fusible link, which has a greater surface area through which it can collect heat. Quick response links are used when life safety is a major concern (i.e., offices). Specialized Sprinkler Heads There are a multitude of sprinkler head types, specialized to meet the needs of almost any type of occupancy. Heads are designed for esthetic purposes, directional coverage, automatic shutoff, and anti-corrosiveness. Esthetic type heads can be: chrome plated or decor (finished or painted), recessed, flush mounted, or unspoiler. Recessed heads are mounted with the deflector flush with the ceiling. A small hole in the ceiling exposes the head to the area of coverage and a finish plate around the hole and head covers exposed piping. The flush mounted head is mounted flush to the ceiling. Under normal conditions, the deflector is flush to the sprinkler nozzle. When activated the deflector extends from the nozzle which opens at the same time. Unspoiler heads are also mounted flush to the ceiling. These heads have a heat reactive cover over the sprinkler head, which hides the head from view. At approximately 135 degrees F the cover will fall off the head. This type of sprinkler head will not usually fuse however, until a temperature of 165 degrees F is obtained.

Engine Module Page 3 of 5 Directional heads can be made in several different ways. Some have deflectors designed to direct the water spray in a specific direction (i.e., oversized or bent deflectors). Other heads are positioned to come out of a sidewall or from a side angle, to attack the fire from its flank. Still others, such as deluge heads, have adjustable nozzles and deflectors that can be changed based on need. Cornice heads are heads designed for installation under cornices or roof ridges. This type of directional head will create a narrow fan-shaped water pattern. In areas where corrosion is a factor, sprinkler heads must be coated so they do not corrode and become non-functional. Typically, heads are coated with wax or lead which melts off in heat. These types of sprinklers are found near the waterfront. Upright and Pendant Sprinkler Heads Sprinkler heads operate in one of two positions, either upright or pendant (facing downward). The important difference between the two is the type of deflector installed on the unit. Upright heads are designed to discharge water upwards towards a concentric deflector, which redirects the water downward in a hemispherical pattern. Pendant or hanging heads have deflectors, which are curved away from the nozzle. These deflectors create a hemispherical pattern when the water is deflected. Early Suppression Fast Response Heads (ESFR) ESFR heads are designed for moderate to high fire loads. The loads are usually in rack storage and the typical building is of a warehouse type. Home Depots are characteristic of the type of occupancy that would use ESFR heads. The heads are designed with a larger orifice, usually ¾ versus ½ for larger volume. They also generally create a tighter cone of water due to the larger distances between stock and the sprinkler heads. Those two features allow for water to penetrate the thermal convection with enough water to reach the seat of the fire as opposed to turning to steam before it reaches the burning material. With the volume of water being greater than other sprinkler heads the importance of an engine company supplying the sprinkler system to boost pressure and volume is as important as ever. Sprinkler Head Temperature Ratings Sprinkler heads are constructed to release water at specific temperatures and in most cases are color-coded to denote the temperature range at which they will begin to expel water. The particular rating used in a given structure or area is determined by the anticipated release of heat by a fire in that area and the highest temperature that the sprinkler may endure during non-fire conditions. Firefighters may encounter sprinkler heads without a color-coding as the case may be with decorative and coated heads. Coated heads should be color coded on the frame arms, and though decorative heads are not required to be color coded, some manufacturers use a colored dot on the top of the deflector to signify the temperature rating. The following table taken from lfsta

Engine Module Page 4 of 5 Essentials, Chapter 16, identifies the temperature ranges and color-coding for sprinkler heads: Sprinkler Color Codes Temperature Rating Frame Color Temperature Classification 135 to 170 Ordinary Unpainted* 175 to 225 Intermediate White or Yellow 250 to 300 High Blue 325 to 375 Extra High Red 400 to 475 Very Extra High Green 500 to 575 Ultra High Orange *These heads may also be half black and half painted, or chrome plated. Sprinkler Head Clearances As stipulated in the Uniform Fire Code (UFC), the minimum clearance below a sprinkler system will be no less than 18 vertical inches from any head. Obstructions could include false ceilings, over-stacked materials, shelves that are constructed too close to the sprinkler heads, and/or over-stacked shelves. Coverage The use made of a building is an essential consideration in designing a sprinkler system that is adequate to protect against the hazards inherent in the type of occupancy. For the purposes of evaluating hazards, three main classes of occupancy are recognized in the NFPA Sprinkler Standard. Classification of Occupancies: The three main classifications are: 1. Light Hazard 2. Ordinary Hazard 3. Extra Hazard Light Hazard Class: Includes occupancies where the quantity and combustibility, or both, of materials is low, and fires with relatively low rates of heat release are expected. Examples are apartments, churches, dwellings, hotels, public buildings, office buildings, and schools. Ordinary Hazard Class: This class is divided into two groups, mainly because each requires a somewhat different water supply for sprinklers. In general, this class includes ordinary mercantile, and manufacturing, and industrial properties.

Engine Module Page 5 of 5 Group 1: Covers properties where combustibility is low, the quantity of combustibles is moderate, stockpiles of combustibles do not exceed 8 ft. in height, and fires with moderate rates of heat release are expected. Examples are canneries, laundries, and electronic plants. Group 2: Includes properties where the quantity and combustibility of con tents is moderate, stockpiles do not exceed 12 ft., and fires with moderate rates of heat release are expected. Examples are cereal mills, textile plants, printing and publishing plants, and shoe factories. Extra Hazard Class: Extra hazard occupancies involve a wide range of variables, which may produce severe fires. Group 1: Includes occupancies with little or no flammable or combustible liquids. Some examples are die-casting, metal extruding, rubber production operations, sawmills, and upholstering operations using plastic foams. Group 2: Includes occupancies with moderately substantial amounts of flammable or combustible liquids or where shielding of combustibles is extensive. Some examples are asphalt saturating, flammable liquid spraying, open oil quenching, solvent cleaning, varnish and paint dipping. The majority of new installations are "calculated" systems. Calculated sprinkler systems are designed with the aid of computers. In all cases, the size of pipes will be smaller in these systems.