MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Similar documents
MAC-A R410A Series Air cooled Modular Chiller

AIR COOLED MINI CHILLER

MODULAR WATER-COOLED CHILLER

MODULAR WATER-COOLED CHILLER

DAIKIN Modular Inverter Air Cooled Chiller

Modular Air Cooled Scroll Chillers

Modular Water Cooled Water Chiller

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Product Line Introduction. Karl Zhang Technical support engineer

MODELS LIST. Nominal Capacity RT

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

Air Cooled Scroll Chiller

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AQUASNAP JUNIOR 30RHV

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Screw Water Cooled Chiller SCW210

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Neosys Product catalogue

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

air systems Roomtop RTC-RTH 15 to 30 - L

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

Scroll Water Cooled Chiller

Modular Water-Cooled Chiller

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Aquaflair TRAC-TRAF-TRAH

MHW Air Handling Unit (50/60Hz)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

water to water heat pumps

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Air-Cooled Condensing Units with Compact Screw Compressors

Modular Air Cooled Chiller/Heat Pump

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Air to water Heat Pump System

H4T R410A. refrigerant

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air Cooled Scroll Chiller / Heat Pump

ERACS.C-N Higher efficiency air-cooled screw pump

DC Inverter Smart VRF Products(R410A)

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Air-cooled modular Chiller. Nick Technical Engineer

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Modular Air-cooled Chillers


Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

INVERTER MINI CHILLER/ HEAT PUMP

Ducted inverter reverse cycle air conditioning

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

MAC-D R410A Series Air-cooled Modular Chiller/Heat Pump

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Increase your flexibility.

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

MAC N-407 Air-Cooled Chiller

Wall Mounted Split Systems

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Split System Air Conditioning

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDRONIC RESIDENTIAL

Water-cooled chillers with High Speed Centrifugal Compressors

Transcription:

Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5 R410A 60kW-536kW 64kW-528kW

Overview Based on the successful McQuay air-cooled modular chiller/heat pump R22 series, McQuay MAC-D R410A series is a new generation of air-cooled chillers/heat pumps. They ideally combine the advanced and mature chiller technology with new type environment-friendly refrigerant. In addition, this series features outstanding performance, high capacity, low sound level, easy installation, and flexible system management, taking the lead in the global market. ISO 9001 Certificate No. : 9601019 Quality Management System Certification ISO 14001 Certificate No. : EMS 80362 Environment Management System Certification BS - OHSAS 18001 Certificate No. : 7644 Test CNAS L0778 The test center is certified by China National Accreditation Service for Conformity Assessment Quality assurance XK06-015-00378 China National Industrial Product Manufacture License Nomenclature MAC 210 D R M 5 - F BA E Export sales code Detailed description Power supply F: 380V/3Ph/50Hz; Refrigerant code 5: R410A Code for modular connected units M: master unit/single unit; S: slave unit; Function type R: heat pump; Omitted for cooling-only units. Design series Cooling capacity code, 21HP. McQuay air-cooled modular chiller European Manufacturing Base of McQuay Air-cooled Heat Pump in Cecchina Italy McQuay Air Conditioning (Shenzhen) Co., Ltd. of McQuay China Asian Manufacturing Base of McQuay Air-cooled Heat Pump McQuay Aubum Factory, USA McQuay Cecchina Factory, Italy 2

Main Features Environment-friendly Refrigerant McQuay is committed to protecting the global ecosystem and has developed air-cooled chiller/heat pump with R410A, a new type of environment-friendly refrigerant. Without chlorine, the environment-friendly R410A causes no harm to the ozonosphere (ODP=0). R410A - no chlorine Sunshine (ultraviolet B) Ozone (O3) Stratosphere (ozone dense area) Troposphere CFC leakage Earth Low sound level Thanks to the newly designed spiral blades, the outdoor units feature smooth air flow, significantly reducing the turbulence and lowering the air flow sound level. Unique compressor sound-insulation design and fully hermetic volute compressor minimizes the operation noise. Moreover, unique Night Mode brings down nightly noise greatly and ensures you a sound sleep. New type spiral blade Easy Installation Semi-M shaped heat exchanger Isolation-designed compressor MAC R410 series is designed to best facilitate user installation. The refrigerant system is made hermetic in the factory. Customers do not need to connect any copper pipe or refill refrigerant or invest more money for complex water systems. Cooling tower Boiler Cooling pump 3

Main Features Multi-grade Modulation MAC R410 series features 2-grade modulation which can be transformed to multi-grade modulations in modular combinations. With operation grades controlled electronically, the unit exerts less shock to the power grid and saves more energy. Compact Size Moreover, MAC R410 series features compact size. Its dimensions and weight are significantly reduced. MAC R410 can be lifted without large lifting tools and located on the roof, balcony or any possible outdoor space. Reliable Operation MAC R410 series adapts modular design and one by one start, reducing the impact upon the grid when starting. All units have undergone strict and long-term test, ensuring reliable operation even under extreme hot/cold conditions. Units themselves, moreover, have multiple protections. The security of units is maximally guaranteed. Outstanding Performance MAC R410 series features leading-edge scroll technology and name-brand accessories which are strictly tested for high compatibility and reliability. Equipped with efficient scroll compressors and precise electronic expansion valves, these units feature high EER and COP, especially at partial load. 4

Control Intelligent Control System MAC-D features user-friendly intelligent control system. Micro chip and large-scaled LCD display are employed to make the control swift and easy. Group control: One single controller can control a group made up by one master unit and maximum 15 slave units. BMS: MAC-D provides interfaces for BMS. One serial port can support maximum 31 gateway and one gateway can support one master unit and maximum 15 slave units. Basic Operating Mode Cooling Heating Parameter Setting Real time setting Weekly timing on/off (one on/off per day) Cooling water inlet temperature Heating water inlet temperature Anti-freezing/defrost temperature setting Defrost point A/B temperature setting Parameter Display Running status display Setted inlet temperature Actual inlet temperature Timing point Anti-freezing/defrost temperature Fault alarm and protection 13 protections and fault alam functions Indoor controller lock Defrost Mode Auto defrost Mannual defrost Memory function Backup battery for realtime clock Customized parameters preservation after power failure Other functions Error log inquiry Average compressor worn time Remote on/off Water system two-way valve control Auxiliary electric heating Note: The length of communication wire between the master unit and the wired controller is 40m. The length of communication wire attached to the slave unit is 5m. The main board of the unit provides an interface for remote control. But remote controllers are not provided and should be installed on site. 5

Specification Model MAC210D5 MAC210DR5 MAC230D5 MAC230DR5 Nominal cooling capacity kw 60 60 65 68 MBtu/h 205 205 222 229 Nominal heating capacity kw -- 64 -- 66 MBtu/h -- 218 -- 225 Cooling input power kw 18.8 19.8 19.2 21.0 Cooling operation current A 35.5 37.2 36.9 36.8 Heating input power kw -- 20.5 -- 20 Heating operation current A -- 38.2 -- 36.2 Power supply 380V/3Ph/50Hz EER Btu\h\W 10.9 10.3 11.5 11.3 COP -- 3.0 -- 3.38 Compressor Type Hermetic scroll compressor Quantity Unit 2 Type New type axial fan Fan Quantity Unit 2 H/L power input kw 1.15x2 / 0.45x2 Type High efficiency BPHE m 3 /h 10.3 10.3 11.2 11.5 Water flow l/s 2.86 2.86 3.11 3.19 Heat (cooling) gpm 45.4 45.4 49.3 50.6 exchanger m 3 /h -- 11 -- 11.4 Water flow l/s -- 3.06 -- 3.16 (heating) gpm -- 48.4 -- 50.2 Unit WPD kpa 38 44 37.3 Water pipe connection size DN50 2" Unit dimensions Packing dimensions Note: (Length Width Height) (Length Width Height) Unit weight mm 1990 840 1840 inch 78.3 33.1 72.4 mm 2010 890 2010 inch 79.1 35 79.1 kg 520 540 520 515 lb 1146 1190 1146 1133 outdoor ambient temperature 35 C. Working conditions for nominal heating capacity: rated water flow; leaving water temperature 45 C; outdoor dry/web bulb temperature 7 C/6 C. the connecting pipes should meet certain standards. contact Shenzhen McQuay for support. 6

Operating Limit Cooling mode Heating mode Ambient temp C Temperature range Ambient temp C Temperature range Outlet water temp ( C) Outlet water temp ( C) Dimensions Mounting hole of anchor bolt 14-14x20 Magnified view of mounting hole of anchor bolt 14x20 Water inlet Rc2 Water outlet Rc2 Unit: mm MAC210D/DR/230D MAC230DR A 171 165 B 369 390 7

Installation Illustration Note: 1. The groundwork should be concrete or V-iron structures, and must be strong enough to bear the operating weight of the unit. 2. Each unit must be fixed by four M12 bolts. 3. A 20mm-thick rubber cushion should be added to the base as a bumper. 4. Applicable model: MAC210DM5/MAC210DS5/ MAC210DRM5/MAC210DRS5/MAC230DM5/ MAC230DS5/MAC230DRM5/MAC230DRS5 Unit: mm Installation Space Ventilation space above the unit >3,000 mm Unit height Distance between the unit and the wall: >1,800 mm Front-to-back distance between two units: > 400 mm Distance between the unit and the wall: >1,800 mm Front-to-back distance between two units: > 400 mm Left-to-right distance between two units: > 1,500 mm Front-to-back distance between two units: > 400 mm Left-to-right distance between two units: > 1,500 mm Front-to-back distance between two units: > 400 mm 8 Distance between the unit and the wall: >1,800 mm Distance between the unit and the wall: >1,800 mm Unit: mm

Water System 9

Water System Legends for the Water System Illustration: 10

Requirements on Water Supply A relief valve must be installed for the water supply system. An air vent valve must be installed at the highest point in the water system. A suitable water drainage valve must be installed at the lowest point in the water system. insulated frequent startup in the case of low load. due to thermal expansion and contraction. A bypass must be installed for the water circuit. The water system must be fully cleaned before water infusion and system startup. in accessory kit Water Quality Requirements Item Requirement ph Between 7 and 9 Suspended matter Suspended material concentration <15mg / l DH CaO content <200mg / l Solid impurity Solid impurities size <1mm Mineralization Open circle: water mineralization <350mg / l Corrosivity Cl-, CO2 and other corrosive substances <100mg / l Fan Coil Unit Ceiling Concealed Unit MCW-C/F/H Model MCW200-1200C/F/H Air Flow 180-2040m 3 /h ESP 0,30,60,80Pa Cooling Capacity 2130-10700W 11

Air Handling Unit Single Skin MHW Model MHW015A-MHW050A Air Flow 1500-5000m 3 /h ESP 70-150Pa Cooling Capacity 6000-87000W Single Skin MSW Model MSW020H-MSW150H MSW040V-MSW250V Air Flow 2000-25000m 3 /h ESP 80-300Pa Cooling Capacity 12000-450000W Double Skin MDW Model MDW020H-MSW250H MDW040V-MSW250V Air Flow 2000-25000m 3 /h ESP 80-300Pa Cooling Capacity 12000-450000W Double Skin MDM Model MDM0304-MDM1826 Air Flow 2000-100000m 3 /h ESP 80-1000Pa Cooling Capacity 14000-700000W 12

Literature No.: CA-MAC D R410A 1301A-50Hz Supersedes: CA-MAC D R410A 1201A-50Hz Part No.: M08039130019 ISO 9001 Certificate No. : 9601019 ISO 14001 Certificate No. : EMS 80362 2013 McQuay International +1 (800) 432-1342 www.mcquay.com BS - OHSAS 18001 Certificate No. : 7644 CNAS L0778 While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.