Ducted Split System Air Conditioners Technical Data

Similar documents
Ducted Split System Air Conditioners Technical Data

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

EC Motor Fan Coil Units. IMD-Y Series l/s

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Packaged Air Conditioning Custom Build Solutions

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

EC Motor Fan Coil Units. IMDL-Y Series l/s

PRODUCT RANGE: ROOFTOP PACKAGE

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

Air Cooled Packaged Units

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Heat Pump Air Conditioning Systems

Ducted inverter reverse cycle air conditioning

Water Cooled Air Conditioners Applications Manual

Hitachi Inverter Wall Split Air Conditioning

SAT-3 Room Temperature Controller

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

TOSHIBA AIR CONDITIONING

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

ROOFTOP PACKAGED AIR CONDITIONERS

USER'S OPERATING INSTRUCTIONS

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Condensing Units CUS 15-60

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Now with WiFi as standard Find out more at

LZA High efficiency air to water heat pumps with HP compressor

Hansol Hi Wall Inverter Heat Pump

What do I need for my bedroom?

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Braemar superior range of reverse cycle air conditioning

TOSHIBA AIR CONDITIONING

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Modular Air Cooled Scroll Chillers

ultimate climate control and advanced energy efficiency THE ESP SERIES

MAC N-407 Air-Cooled Chiller

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Product Brochure Smart Power. Low Profile Ducted

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Q Series. Inverter Split Systems

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

PAJ3. Product Specifications

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

VariCool VAV Engineering Guide

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

LZT High efficiency air to water heat pumps with E.V.I. compressors

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

AQUASNAP JUNIOR 30RHV

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Item No. (Standard/Opposite Hand) /

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

MACH N-407 Heat Pump Air-Cooled Chiller

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Product Brochure 2017

Hi - Wall Split Systems 12K - 18K - 24K

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

designed for air conditioning australian living

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

GUIDE SPECIFICATIONS AQUARIUS ii

Highly Efficient,Powerful Heating and Cooling.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Transcription:

Technical Data ISD 294, ISD 324 Cooling Capacity 27.9kW - 34kW Heating Capacity 28.2kW -32.2kW

Contents ISD 294, 324 KYX SERIES General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A 4 User Friendly 4 Economy 4 Efficient 4 Performance 4 Quiet 5 Durable 5 Low Maintenace 5 Soft Starting 5 Insulation 5 Control Option 5 Self Diagnostics 5 Zone Control 5 Optional Equipment 6 Safety Features 6 Compressor 6 Refrigeration Piping 6 Wiring 6 PERFORMANCE DATA Cooling Capacity (kw) 8 Reverse Cycle Systems / 9 Heating Capacity (kw) Indoor Air Flow Correction Factors @ nominal conditions Air Handling 10 Sound Levels 11 Indoor Unit - Supply Air Outlet 11 Sound Pressure Levels (SPL) Within A Room 11 Outdoor Unit 12 DIMENSIONS ISD Indoor Unit 13 OSA Outdoor Unit 14 SPECIFICATIONS 15 9 SAT-3 CONTROLLER (Optional) Features Summary 7 Page 2 of 16

ISD 294, 324 KYX The ISD indoor units, together with their associated OSA outdoor units, provide a reverse cycle (heat pump) split system air conditioner designed and developed to comply with and exceed AS/NZS 3823. Each system has been successfully tested at 52 C ambient. Page 3 of 16

ISD 294, 324 KYX series Applications These units have been specifically developed for air conditioning of commercial premises, e.g. offices, motels, shops and restaurants. Suitable for applications using full or high proportions of fresh air (nb pre-heating on heating cycle may be required). Also suitable for VAV, close control and supply air temperature control. AIR FLOW SELECTION If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less (refer Air Flow graph; 2.5 m/s is clearly marked). High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Refrigerant R410A Each complete system uses refrigerant R410A which is has a zero ozone depletion potential. User Friendly The air conditioning system is available with an optional SAT-3 or TZT-100 Controller which is wired to the Indoor or Outdoor unit. These thermostats have been designed to maintain a high level of comfort for room occupants. Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it. Use of the Auto and Timer function settings allows you to set it and forget it. Economy Both the ISD/OSA 294 & 324 systems have variable capacity compressors which use less energy than alternative types of compressor. Efficient Indoor units include a high efficiency electronically commutated (EC) motor. Part load operation at low loads (75% airflow equates to 55% power use) using temperzone algorithms. Each outdoor unit incorporates a high efficiency compressor. Heat exchange coils use inner grooved (rifled) tube for better heat transfer. Performance The variable capacity compressor technology can provide close comfort control of the room temperature. The OSA 294F and 324F have an extra boost capacity available for fast response when well away from set point at start-up. A dynamically balanced forward curved fan with a multi-speed EC motor enables fine tuning of the indoor unit to match the supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing head pressure control which enables the Page 4 of 16

ISD 294, 324 KYX series system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Quiet Each integral high efficiency EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. The outdoor units coil design permits low fan speeds and hence low noise levels. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Durable Both indoor and outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. Each outdoor unit s cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 44). External fasteners are stainless steel. Heat exchange coils comprise aluminium corrugated plate fins on mechanically expanded rifled copper tube. Each indoor unit s cabinet is constructed from high grade galvanised steel and includes a plastic drain tray for complete corrosion resistance. Outdoor coils are protected with louvred anti-hail guards. Low Maintenance. Commissioning and maintenance costs are reduced through use of a fan that requires no pulley and belt adjustments or changes like traditional fans. Soft Starting EC motors are soft starting therefore have none of the problems associated with high in rush current. Insulation Closed cell foam insulation has been used in the indoor units cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1999) and BS 476 parts 6 & 7. Control Option Commissioning is made easier when the EC motor to be controlled variably (within a restricted range) by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone s optional TZT-100 Controller. The systems UC8 controller is BMS compatible with multi-unit control possible either via digital and analogue signals or via Modbus. Refer to temperzone for other protrocols available. Self Diagnostics The Outdoor Unit Controller (UC8) has a LED display to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems via the optional relay board. Zone Control ISD-KYX versions using SAT-3 controller can be fitted with the optional Zone Control kit which allows up to 6 zone dampers to be switched from the SAT-3 wall control. Standard damper motors, 24 volt ac, can be used with drive open/drive close. Page 5 of 16

ISD 294, 324 KYX series OPTIONAL EQUIPMENT Outdoor Unit: 1. Anti-vibration mounts (rubber) 2. Drain connection - right angle 3. Fault relay board (201-000-105) Indoor Unit: 1. temperzone SAT-3 Controller or TZT-100 Controller. 2. Six Zone Control kit for SAT-3. 3. Spring mounting kit. 4. Supply & return air spigots (available in New Zealand only) 5. Filter Box c/w EU4/G4 rated filter. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch ensures icing up of the outdoor coil during heating cycle is kept to a minimum. REFRIGERATION PIPING Maximum line length is 90m. Max. height separations between units are: Outdoor unit above indoor unit: 20m Outdoor unit below indoor unit: 20m. Each OSA unit is shipped from the factory with a charge of HFC-410A (R410A) refrigerant sufficient for a 10m line length. Liquid and suction service valves are provided. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. WIRING The electrical supply required (including voltage fluctuation limits) is: 3 phase 380 440 V a.c. 50 Hz with neutral and earth. A control panel, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system complies with the requirements of the Regulatory Compliance Mark (RCM) for electrical safety (AS/NZS 60335.2.40) and EMC (AS/NZS CISPR.14). Provision has been made for compliance with DRED, ie demand response enabling device standard AS/NZS 4755.3.1. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Compressor minimum run time to ensure oil return. 8. 12V control circuit. COMPRESSOR Each high efficiency variable capacity compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Digital compressors have proven very reliable because of their design simplicity; electrical harmonic noise is very low. Page 6 of 16

SAT-3 Controller (Optional) Open Closed FEATURES SUMMARY Cool / Dry / Fan modes. Heat / Auto modes Auto / High / Medium / Low fan speed selection. (customisable). Temperature setting range from 16 C 30 C. Room temperature display. Real time clock. 7 day timer up to four start and/or stops per day Override countdown run timer; up to 4 hours. Continuous or Intermittent selection of fan run-on in dead zone. Backlit screen for ease of reading; changes colour for each mode. Soft touch tab keys Battery backup (Lithium). Sleep function improves night time comfort and saves energy. Eco mode for ecomical operation. Quiet mode for outdoor unit. Low voltage control cable. Connects to either indoor unit or outdoor unit. Colour: white and light grey (Keypad - green and blue). Optional: 1. Remote return air sensor 2. Six Zone Control kit Note: Not backwards compatible with units using SAT-2. TZT-100: Refer www.temperzone.biz for information. Page 7 of 16

Performance Data COOLING CAPACITY (KW) Total = Total Capacity (kw). Sens. = Sensible Capacity (kw). E.A.T. = Entering Air Temperature. = Nominal Capacity (kw). Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity.. Models Indoor Unit Outdoor Unit ISD 294 OSA 294G ISD 294 OSA 294F ISD 324 OSA 324G ISD 324 OSA 324F Indoor Fan Speed Air l/s High 1570 High 1570 High 1725 High 1725 Indoor coil E.A.T. D.B. C W.B. C Outdoor coil entering air temperature C D.B. 23 27 31 35 39 43 Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 21 15 28.0 21.4 27.6 21.4 26.8 20.9 25.6 202 23.9 19.1 21.8 17.6 23 17 29.4 20.9 29.1 20.9 28.4 20.5 27.0 19.8 25.5 18.9 23.3 17.5 27 19 30.9 24.0 30.6 23.9 29.8 23.6 28.4 22.9 26.9 21.7 24.7 20.3 31 21 32.5 28.3 32.2 28.3 31.3 27.9 30.1 27.1 28.4 25.9 26.3 24.3 21 15 27.6 21.2 27.2 21.2 26.4 20.8 25.2 20.1 23.5 19.0 21.5 17.5 23 17 29.0 20.8 28.7 20.8 27.9 20.4 26.6 19.7 25.1 18.8 22.9 17.4 27 19 30.4 23.9 30.1 23.8 29.4 23.4 27.9 22.7 26.5 21.6 24.3 20.2 31 21 32.0 28.1 31.6 28.1 30.8 27.7 29.6 26.9 27.9 25.7 25.8 24.1 21 15 31.9 24.7 31.5 24.7 30.5 24.1 29.1 23.3 27.1 22.1 24.8 20.3 23 17 33.5 24.1 33.1 24.1 32.3 23.7 30.8 22.9 29.0 21.8 26.4 20.2 27 19 35.2 27.7 34.8 27.6 34.0 27.2 32.3 26.4 30.6 25.1 28.1 23.4 31 21 37.0 32.7 36.6 32.7 35.6 32.2 34.2 31.3 32.3 29.9 29.9 28.0 21 15 33.6 25.7 33.2 25.7 33.1 25.1 30.7 24.2 28.6 23.0 26.1 21.1 23 17 35.3 25.1 34.9 25.1 34.0 24.7 32.4 23.8 30.5 22.7 27.9 21.0 27 19 37.1 28.8 36.7 28.8 35.8 28.3 34.0 27.5 32.3 26.1 29.6 24.4 31 21 39.0 34.0 38.6 34.0 37.5 33.6 36.1 32.6 34.0 31.2 31.5 29.2 Refer page 8 for Indoor Air Flow Correction factors Page 8 of 16

Performance Data - Reverse Cycle Systems HEATING CAPACITY (KW) G N = Gross Heating Capacity kw, based on nominal air flow. = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw). Models Indoor Entering Air Temp. C Outdoor coil entering air temperature C D.B. Indoor Unit Outdoor Unit D.B. -5-3 -1 1 3 5 7 9 G N. G N. G N. G N. G N. G N. G N. G N. ISD 294 OSA 294G ISD 294 OSA 294F ISD 324 OSA 324G ISD 324 OSA 324F 15 21.3 20.1 22.5 19.8 23.7 20.1 24.9 21.3 26.1 23.9 27.4 27.4 28.6 28.6 29.8 29.8 20 21.0 19.8 22.2 19.6 23.4 19.9 24.6 21.1 25.8 23.6 27.0 27.0 28.2 28.3 29.5 29.5 25 20.3 19.3 21.5 19.1 22.7 19.3 23.9 20.6 25.2 23.1 26.4 26.4 27.6 27.6 28.8 28.8 15 20.7 19.5 21.9 19.3 23.1 19.6 24.3 20.8 25.4 23.2 26.6 26.6 27.8 27.8 29.0 29.0 20 20.4 19.3 21.6 19.1 22.8 19.3 24.0 20.5 25.1 23.0 26.3 26.3 27.5 27.5 28.7 28.7 25 19.8 18.8 20.9 18.5 22.1 18.8 23.3 20.0 24.5 22.5 25.7 25.7 26.8 26.8 28.0 28.0 15 22.8 21.5 24.1 21.3 25.4 21.6 26.7 22.9 28.0 28.0 29.3 29.3 30.6 30.6 31.9 31.9 20 22.5 21.3 23.8 21.0 25.1 21.3 26.4 22.6 27.7 27.7 29.0 29.0 30.3 30.3 31.6 31.6 25 21.8 20.7 23.1 20.4 24.4 20.7 25.7 22.0 27.0 27.0 28.3 28.3 29.6 29.6 30.9 30.9 15 24.3 22.9 25.6 22.6 27.0 22.9 28.4 24.3 29.8 29.8 31.2 31.2 32.6 32.6 33.9 33.9 20 23.9 22.6 25.3 22.3 26.7 22.6 28.1 24.0 29.4 29.4 30.8 30.8 32.2 32.2 33.6 33.6 25 23.1 22.0 24.5 21.7 25.9 22.0 27.3 23.4 28.7 28.7 30.1 30.1 31.4 31.4 32.8 32.8 INDOOR AIR FLOW CORRECTION FACTORS @ NOMINAL CONDITIONS Indoor Air Flow (%) -20-10. Rated +10 Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 Page 9 of 16

Performance Data AIR HANDLING Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow application, beware of exceeding indoor fan motor s full load amp limit. Refer back page for filter losses. Air flows given are for ISD units without filter installed. ISD 294KYX ISD 324KYX l/s - Pa 250 200 3.1A 150 2.0A 100 1.5A 8V 4.5A 6V 5V 7V - - - - l/s - W 1.6 8V 1.4 7V 6V 6.4A 4.8A 1.2 1.0 0.8 0.6 0.4 INPUT (kw) l/s - Pa 250 200 150 100 3.5A 2.6A 5.1A 8V 7V 4.8A - - - - l/s - W 1.6 8V 7V 6V 6.6A 1.4 1.2 1.0 0.8 0.6 0.4 INPUT (kw) 6V 50 5V 50 0 2.1A 3.5A 800 1000 1200 1400 1600 1800 AIR VOLUME (l/s) Nominal 2.5 m/s Face Velocity 4.3A 0 1200 1400 1600 1800 2000 2200 NOMINAL AIR VOLUME (l/s) 2.5 m/s Face Velocity Filter Pressure Drop PRESSURE DROP (Pa) 100 80 60 40 20 EU4/G4 rated filter media (used in optional Filter Box) MAX. FINAL PRESSURE DROP 250 Pa INITIAL (Clean Filter) 0 0 0.5 1.0 1.5 2.0 2.5 3.0 FILTER FACE VELOCITY (m/s) Page 10 of 16

Performance Data SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. INDOOR UNIT - SUPPLY AIR OUTLET OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS (SWL) db 4 V 64 64 59 62 58 57 54 ISD 294 6 V 68 67 63 66 63 61 58 8 V 73 70 67 71 68 65 64 6 V 64 64 59 62 58 57 54 ISD 324 7 V 68 67 63 66 63 61 58 8 V 73 70 67 71 68 65 64 SOUND PRESSURE LEVELS (SPL) WITHIN A ROOM Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Room type ROOM ABSORPTION EFFECT Soft 4 8 11 11 11 11 Medium 3 7 8 9 9 9 Hard 0 1 3 4 4 5 Page 11 of 16

Performance Data SOUND LEVELS Sound Power Levels (SWL) OUTDOOR UNIT OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS (SWL) db LOW 69 80 70 65 62 58 52 OSA 294 MED 72 85 72 67 64 60 53 HIGH 75 89 73 68 65 61 54 LOW 65 72 66 62 59 54 47 OSA 324 MED 68 77 69 65 62 57 50 HIGH 71 76 73 68 66 61 54 Models FAN SPEED SPL @ 3 m db(a) SOUND PRESSURE LEVELS (SPL) db LOW 53 64 54 50 46 42 36 OSA 294 MED 56 69 56 51 48 44 37 HIGH 59 73 57 52 49 45 38 LOW 49 56 50 46 43 38 31 OSA 324 MED 52 61 53 49 46 41 34 HIGH 55 60 57 52 50 45 38 Sound Pressure Level (SPL) in decibels re 20 µpa. Page 12 of 16

Dimensions (mm) ISD INDOOR UNIT POINT LOADS (kg) MODEL W X Y Z ISD 294 31 27 37 32 ISD 324 32 35 39 37 Note: Fan motor can be accessed from panel above or sides: no more than two panels at once. PROJECTION 45 1923 OPTIONAL SPRING OR FIXED MTG CENTRES 1772 OPTIONAL FILTER BOX FILTER ACCESS EITHER SIDE W 558 FIXED MTG CENTRES 622 OPTIONAL SPRING MTG CENTRES X Y REFRIG. CONN S 698 OA 750 MIN. CLEARANCE Z ISD 294: 134 ISD 324: 181 1505 ELECTRICAL BOX ELECTRICAL BOX 50 ACCCESS PANEL 50 285 25 ISD 294: 435 ISD 324: 550 OVERALL REFRIG. CONN S 253 ISD 294: 365 ISD 324: 485 2020 OVERALL DRAIN 19 OD ISD 294: 32 ISD 324: 71 OPTIONAL FILTER BOX 45 Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 13 of 16

Dimensions (mm) OSA OUTDOOR UNIT POINT LOADS (kg) W X Y Z 49 87 60 49 PROJECTION 150 MIN. CLEARANCE W 150 MIN. CLEARANCE X 1000 MIN. CLEARANCE Recommended Interconnecting Pipe Sizes Suction : 28 mm OD Liquid : 13 mm OD Z Y 150 MIN. CLEARANCE 2000 MIN. CLEARANCE ELECTRICAL & SERVICE ACCESS PANEL 32 DIA. ELECTRICAL CONDUIT HOLES 1335 OA REFRIG. CONN'S 25 DIA. DRAIN HOLE 80 1189 MTG CTR 12 DIA. HOLES 1595 OA 205 25 DIA. DRAIN HOLE 800 MTG CTR 840 OA 25 DIA. DRAIN HOLE Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 14 of 16

Specifications System Indoor Unit ISD 294KYX ISD 294KYX ISD 324KYX ISD 324KYX Outdoor Unit OSA 294G OSA 294F OSA 324G OSA 324F Nominal Cooling Capacity * 1 kw 11.5~28.4 5.6~27.9~33.5 12.9~32.3 6.8~34~40.8 Net Cooling Capacity (MEPS) * 1 kw 27.5 27.1 31.5 33.3 EER / AEER (cooling) 3.12 / 3.10 3.13 / 3.11 3.12 / 3.10 3.18 / 3.16 Heating Capacity * 2 kw 11.3~28.2 5.5~27.5~33 12.1~30.3 6.4~32.2~38.6 COP / ACOP (heating) 3.53 / 3.51 3.47 / 3.45 3.83 / 3.81 3.80 / 3.77 Air Flow* 3 l/s 1570 1570 1725 1725 Sound Levels * 4 Indoor Unit (SWL) 68 68 68 68 Outdoor Unit (SPL) 59 59 55 55 Power Source 3 phase 400 V a.c. 50 Hz Compressor type digital inverter digital inverter Indoor Fan Max. Current A 10 10 12.5 12.5 Running Amps (Total) A/ph. 18.5 / 14 / 14 17 21.6 21 Refrigerant HFC-410A ( R410A) Maximum Vertical Separation m 20 20 20 20 Maximum Line Length m 90 90 90 90 Pipe Sizes (Suction/Liquid) mm OD 28 / 13 28 / 13 28 / 13 28 / 13 Operating Range (outdoor ambient) Cooling -10 C to 52 C Heating -15 C to 25 C Finish Indoor Unit Outdoor Unit Weight (net/shipping) kg zinc galvanised steel grey polyester powder coat Indoor Unit 127 / 150 127 / 153 143 / 169 143 / 169 Outdoor Unit 245 / 275 245 / 298 245 / 275 275 / 305 Notes: * 1 Nominal Cooling Capacity (gross) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. * 2 Heating Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Sound Levels are measured at nominal cooling capacity conditions stated above. SPL measured at 3m from unit. Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 15 of 16

www.temperzone.biz AUCKLAND Head Office 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Phone (09) 279 5250 Fax (09) 275 5637 SYDNEY Head Office 14 Carnegie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au Phone (02) 8822-5700 Fax (02) 8822-5711 NEWCASTLE Phone (02) 4962-1155 Fax (02) 4961-5101 LAUNCESTON Phone (03) 6331-4209 Fax (03) 6333-0224 WELLINGTON Phone (04) 569 3262 Fax (04) 566 6249 ADELAIDE Phone (08) 8115-2111 Fax (08) 8115-2118 JAKARTA Phone +62 (21) 2963 4983 Fax +62 (21) 2963 4984 CHRISTCHURCH Phone (03) 379 3216 Fax (03) 379 5956 MELBOURNE Phone (03) 8769-7600 Fax (03) 8769-7601 SINGAPORE Phone +65 6733 4292 Fax +65 6235 7180 BRISBANE Phone (07) 3308-8333 or 1800-897 - 253 Fax (07) 3308-8330 SHANGHAI Phone +86 (21) 5648 2078 PERTH Phone (08) 6399-5900 Fax (08) 6399-5932 Available from temperzone limited 2017 11/17 Pamphlet No. 4071a