Carbon Monoxide CO Transmitter ADT-X3-1110

Similar documents
Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

PolyGard 2-channel Gas Controller MGC-03

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

Multi-Gas-Controller MGC2

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Two-Channel Gas Controller

CMF, CMX & CMA series

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

Gas Controller Module GC-06

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

Danfoss gas detection units

Danfoss gas detection units

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Sensor unit MC2 with analog output for Freon gases and refrigerants

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

Carbon Monoxide Transmitter

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

User Manual. PolyGard SPC Carbon monoxide (CO) gas detection and control system serial no. SPC April 01, 2004

Oxygen (O2) Single-Point Gas Detection System

Toxic Gas Detection. Model F12. Toxic Gas Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Danfoss gas detection Controller unit

Danfoss gas detection unit Type GD Heavy Duty

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

APPLICATION DATA SHEET

Inc Series Digital Gas Detector/Controller. Operation Manual

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Warranty Registration

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

IGD.CO.UK

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

GAS DETECTOR ST400EC PART.NO

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Accuracy by Design Products for the HVAC Professional

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Model D12. Digital Gas Transmitter

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

S5000 Gas Monitor. GMS5000.com

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Xgard. Fixed detectors For flammable, toxic or oxygen gases

ALTAIR 5X Multigas Detector Product Specification

Combustible Gas Detection and Control System

Frequently Asked Questions

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Model D12-IR. Digital Gas Transmitter...

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

Version Digital Gas Detector/Controller. Operation Manual

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Stand Alone DYNAGARD SP Operation Manual

02/11/2015

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

02/11/2015

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Version Digital Gas Dector/Controller. Operation Manual

Dräger Polytron 5720 IR Toxic Gas Detection

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

portable gas analyser

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

PERFECT SOLUTIONS FOR GAS ALARM SYSTEMS. Garage. Gas Alarm, Ventilation and Parking Management for Garages. Version EN SAFETY FIRST

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

P R O D U C T D ATA S H E E T

MICRO III (G202 / G202s / G212) Single Gas Detector

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Sieger Apex. Flexibility that meets your requirements

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

ESD3000 ESD200 Combustible / Toxic Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Transcription:

Page 1 Sep. 2017 CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO). Comfortable calibration routine with selective access release is integrated in the transmitter. The ADT-X3 possesses a standard analog output (0) 4-20 ma or (0) 2 10 V DC, and an RS-485 interface. 2 relays with adjustable switching thresholds are available as an option. APPLICATION For the detection of carbon monoxide (CO) within a wide range of commercial applications such as underground garages, tunnels, engine repair shops, loading bays, engine test benches, shelters, go-kart race courses etc. Due to the 4 to 20 ma output signal the CO transmitter is compatible to the PolyGard series MGC/DGC by MSR-E as well as to any other electronic control or automation system. FEATURES Standard Housing Digital measurement value processing incl. temperature compensation. Continuous monitoring Low zero point drift Good stability to poisoning Long life sensor Modular plug-in technology Easy maintenance Comfortable calibration with selective access release Reverse polarity protected, overload and short-circuit proof (0) 4-20 ma / (0) 2 10V analog signal output, selectable Serial interface RS-485 (optional ModBus, BacNet MS/TP) IP65 protection Manual calibration via potentiometer (option) Manual addressing for RS-485 mode (option) 4 20 ma analog input for external transmitter (optional) Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1 Relay output (optional) Integrated buzzer (optional) LED flashlight (optional) LED status display (optional) Heating (optional) Duct mounting (optional) is a registered trademark of MSR-Electronic GmbH

Page 2 Sep. 2017 SPECIFICATIONS General sensor performance Detected gas Carbon monoxide (CO) Sensor element Electrochemical, diffusion Measuring range: - Standard - Optional 0 300 ppm 50 2000 ppm Pressure range Atmospheric ± 10 % Humidity range 15 90 % RH non-condensing Storage temperature 5 C to 30 C (41 F to 86 F) Storage time 6 months Mounting height 1.5 to 1.8 m (5 6 ft.) Sensor coverage 465 m 2, (5,000 sq.ft.), to 930 m 2 (10,000 sq.ft.) ideal conditions assumed Typ ADTG3-1110 Accuracy ± 3 ppm Repeatability ± 3 % of reading Long term zero-point drift < 5% signal loss/year Response time t 90 50 s Sensor life expectancy 5 years, normal operating environment Humidity range: Short-time 0 95 % RH non-condensing Working temp.: Continuous -10 C to + 50 C (14 F to 122 F) w/o heating Working temp.: Short-time -20 C to + 50 C (-4 F to 122 F) w/o heating Cross sensitivity* Concentration (ppm) Reaction (ppm) Acetone, C 3 H 6 O 1000 0 Acetylene, C 2 H 2 40 80 Ammonia, NH 3 100 0 Carbon dioxide, CO 2 5000 0 Chlorine, Cl 2 2 0 Ethanol, C 2 H 5 OH 2000 5 Hydrogen, H 2 100 20 Hydrogen Sulphide, H 2 S 25 0 Iso Propanol, C 3 H 8 O 200 0 Nitric oxide, NO 50 8 Nitrogen dioxide, NO 2 50-1,0 Sulphur dioxide, SO 2 50 < 0.5 Typ ADT53-1110 Accuracy ± 1 ppm Repeatability ± 2 % of reading Long term sensitivity output drift < 2% signal loss/month Response time t 90 40 s Sensor life expectancy 3 years, normal operating environment Working temp.: Continuous -10 C to + 45 C (14 F to 113 F) w/o heating Working temp.: Short-time -20 C to + 50 C (-4 F to 122 F) w/o heating Cross sensitivity* Concentration (ppm) Reaction (ppm) Sulphur dioxide, SO 2 50 0 Hydrogen Sulphide, H 2 S 25 0 Nitrogen dioxide, NO 2 50 0 Nitric oxide, NO 50 0 Hydrogen, H 2 100 < 60 * The table doesn t claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned cross sensitivity data are only reference values valid for new sensors. is a registered trademark of MSR-Electronic GmbH

Page 3 Sep. 2017 Electrical Power supply 18-28 VDC/AC, (reverse polarity protected) (without options) 22 ma, max. (0.6 VA) Output signal Analog output signal (0) 4 20 ma, load 500, Selectable: Current / tension (0) 2-10 V, load 50 k Starting point 0 / 20 % proportional, overload and short-circuit proof Serial interface Transceiver RS 485 or optional BacNet MS/TP 9600 / 19200 / 38400 Baud (9600 at Mod_Bus) Physical characteristics Enclosure Plastic Type A* Polycarbonate Flammability UL 94 V2 Enclosure colour* RAL 7032 (light grey) Dimensions (W x H x D) 94 x 130 x 57 mm (3.7 x 5.12 x 2.24 inch.) Weight Approx. 0.5 kg (1.1 Ibs.) Protection class IP 65 Installation Wall mounting Cable entry Standard 1 x M 20 Wire connection Screw type terminal, min. 0.25 mm 2 (24 AWG) max. 2.5 mm 2 (14 AWG) Wire distance Current signal: ca. 500 m (1500 ft) Voltage signal: ca. 200 m (600 ft.) Certificates VDI 2053 German air treatment systems for car parks (pending) Guidelines EMC Directives 2004/108/EC EN 61010-1:2010 ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 CE Warranty 1 year on sensor (not if poisoned or overloaded) 2 years on device Options Relay output Alarm relay 1 30 VAC/DC, 0,5 A, potential-free, SPDT Alarm relay 2 30 VAC/DC, 0,5 A, potential-free, SPNO/SPNC 30 ma, (max 0.8 VA) Warning buzzer Acoustic pressure 85 db (distance 300 mm) (1 ft) Frequency 3.5 khz 30 ma, (max 0.8 VA) LED display Green-yellow-red Supply, low alarm, high alarm 10 ma, (max. 0.3 VA) Heating Temperature controlled 3 C ±2 C (37.5 F ± 3.6 F) Ambient temperature - 40 C (- 40 F) 0.3 A; 7.5 VA Analog Input Only for RS-485 mode 4 20 ma overload and short-circuit proof, input resistance 200 Power supply for external transmitter 24 VDC max. 50 ma *For further enclosure types see datasheet ADT Enclosure. is a registered trademark of MSR-Electronic GmbH

Page 4 Sep. 2017 ORDER INFORMATION ADT- X3-1110- X- XXXXXXXXX Options 1XXXXXXXX Relay output 2 X1XXXXXXX Buzzer int. X2XXXXXXX Flashlight (LED) X3XXXXXXX Warning buzzer and flashlight XX1XXXXXX Heating XXXX1XXXX RS- 485 protocol for DGC-05 series XXXX2XXXX RS- 485 protocol ModBUS XXXX3XXXX RS- 485 protocol customers specification XXXXDXXXX MSR_D_Bus protocol 4 XXXXFXXXX BacNet MS/TP, Low-Adr.(1-60), 9600 Baud, ID1 4 XXXXGXXXX BacNet MS/TP, L-Adr.(1-60), 9600 Baud, ID6 4 XXXXHXXXX BacNet MS/TP, L-Adr.(1-60), 19200 Baud, ID6 4 XXXXIXXXX BacNet MS/TP, L-Adr.(1-60), 38400 Baud, ID6 4 XXXXJXXXX BacNet MS/TP, High-Adr. (61-120), 9600 Baud, ID1 4 XXXXKXXXX BacNet MS/TP, H-Adr. (61-120), 9600 Baud, ID6 4 XXXXLXXXX BacNet MS/TP, H-Adr. (61-120), 19200 Baud, ID6 4 XXXXMXXXX BacNet MS/TP, H-Adr. (61-120), 38400 Baud, ID6 4 XXXXX1XXX Calibration / addressing mode tool XXXXX2XXX Manual calibration XXXXX3XXX Manual addressing XXXXX4XXX Manual calibration / addressing XXXXXX2XX LED status display 2,3 XXXXXXX1X 4 20 ma analog input XXXXXXXX1 Factory calibration 0-300 ppm XXXXXXXX2 Factory calibration 0-150 ppm XXXXXXXX3 Factory calibration 0-200 ppm XXXXXXXX4 Factory calibration 0-100 ppm XXXXXXXX5 Factory calibration 0-50 ppm XXXXXXXX6 Factory calibration 0-400 ppm XXXXXXXX7 Factory calibration 0-500 ppm XXXXXXXX8 Factory calibration 0-1000 ppm XXXXXXXX9 Factory calibration 0-2000 ppm XXXXXXXXA Factory calibration 0-250 ppm Housing 1 A Plastic housing B Duct mounting 5 Stainless steel Sensor type / version GX Sensor type ADTG3-1110 5X Sensor type ADT53-1110 1 See Data sheet PolyGard ADT Enclosure 2 Please indicate thresholds for low and high alarm when ordering. 3 Not in connection with stainless steel housing, not in connection with option Relay or RS-485 interface 4 Only in connection with manual calibration / addressing is a registered trademark of MSR-Electronic GmbH

shield 4-20 ma 24 VDC 0 VDC Option Relay P E R F E C T S O L U T I O N S I N G A S A L A R M S Y S T E M S Page 5 Sep. 2017 EXAMPLE CO transmitter, Sensor type ADTG3-1110, stainless steel housing, tool mode, factory calibration 0-300 ppm Order Number: ADT-G3-1110-5 XXXXX1XX1 CONNECTION DIAGRAM Controller 7 6 5 4 3 2 1 X4 Bus_B Bus_A 4-20 ma_inp 4-20 ma 24 VDCOut 0 VDC 24 VDCInp R2 Transmitter ADTX3-11XX R1 1 NO 2 NC 3 COM 4 NO 5 COM X5 O VDC: Two wire mode only with 4 to 20 ma Output signal is a registered trademark of MSR-Electronic GmbH