Post Accident Monitoring in PFBR Safety in Nuclear Power Plant

Similar documents
Design Characteristics and Classification Issue of the I&C Systems for the JRTR

Development of Post-Accident Monitoring System for Severe Accidents

Lata Mishra Bhabha Atomic Research Centre, INDIA

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

The Opal Reactor s I&C Systems

Reactor Protection Systems for the Replacement Research Reactor, ANSTO

TECHNICAL FEATURES OF MMIS DESIGN AND TECHNOLOGIES OF SMART

Digital Reactivity Meter NFA-09.03

Dynamic Radon Detection Over Measurement

Plant Performance 2017 User Symposium

LAUNDRY MONITORING SYSTEM Model # LIM-64S

American Nuclear Society (ANS)

An Instrumentation and Control for Loop Test

Brazil. Current status in NPP I&C and Discussion Topics. 24th Meeting of the IAEA TWG-NPPIC

TraceNet ECM Series Control System

Criteria I&C and Inherent Characteristics

Radiation Control and Monitoring System on the HTTR

Numerical Experimental Research in Justification of Fire (Sodium) Safety of Sodium Cooled Fast Reactors

Design of Humidity Monitoring System Based on Virtual Instrument

Fiber Optic Cable Qualification Update

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Safeguards in Prototype Fast Breeder Reactor Monju

A Continuous Air Monitoring Sampler for 125 I - RIS-125

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Using the DewTrak II Dew Point/ Humidity Transmitter

Seismic Countermeasures for Environmental Radiation Monitoring System

EXCELLENCE in Solutions Products Service

Laboratory Impex Systems Ltd

Plant Data of Fukushima Daiichi Nuclear Power Station at the time of the Tohoku-Chihou-Taiheiyou-Oki Earthquake. May 16 th, 2011

Numerical Standards Listing

Instrumentation for Nuclear Applications

Customized Products for Department of Atomic Energy, India

Numerical Standards Listing

AP1000 European 11. Radioactive Waste Management Design Control Document

Quality Assurance of Radiation Protection Monitoring Instruments in India

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Protection against Internal Hazards in the Design of Nuclear Power Plants

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Computer-based Alarm Processing and Presentation Methods in Nuclear Power Plants

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

IAEA SAFETY STANDARDS

Construction of An Automatic Power Switch using Infrared Motion Sensor

Fin-Fan Control System

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

Using the Model 1500 Portable Chilled Mirror Hygrometer

AUTOMATION OF BOILERS USING LABVIEW

The IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.

Android Controlled Fire Fighting Robot

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Effective Alarm Management for Dynamic and Vessel Control Systems

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

300/400 UNITS - MODULAR CONFIGURATION

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Licensing of digital Instrumentation & Control in Radioisotope Production Facility

A NEW, SMALL DRYING FACILITY FOR WET RADIOACTIVE WASTE AND LIQUIDS

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

Bench Model of Electrical Control System for Inflatable Hemi- Spherical Structure

Numerical Standards Listing

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

Design & Control of an Elevator Control System using PLC

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

High Integrity Pressure Protection System

Advanced Radiation Measurement Solutions

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Document Preparation Profile (DPP)

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Microcontroller based design for Tele-sensing and extinguishing fire

OVERVIEW AND FUTURE DEVELOPMENT OF THE NEUTRON SENSOR SIGNAL SELF-VALIDATION (NSV) PROJECT

Results of Recent DOE Research on Development of Cable Condition Monitoring and Aging Management Technologies

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. COMPONENT COOLING SYSTEM FOR THE NUCLEAR ISLAND (RRI [CCWS])

Ronan Model X96S Series Density System

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

Fire alarm system EBL512 G3

ALARMING NEWS FROM INVENSYS PROCESS SYSTEMS, INC.

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Chapter 1. Introduction

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 3. CONTINUOUS VENTILATION OF THE CONTAINMENT (EVR [CCVS])

RIID capability in the palm of your hand

Certification Report of the ST3000 Pressure Transmitter

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Process & TeMPerATUre UniversAl input DigiTAl MeTers

CLARITY II TURBIDIMETER

Transcription:

Engineering Management Research; Vol. 3, No. 2; 2014 ISSN 1927-7318 E-ISSN 1927-7326 Published by Canadian Center of Science and Education Post Accident Monitoring in PFBR Safety in Nuclear Power Plant M. Sivaramakrishna 1, C. P. Nagaraj 1 & K. Madhusoodanan 1 1 Indira Gandhi Centre for Atomic Research, Kalpakkam, India Correspondence: M. Sivaramakrishna, RDG, Igcar, Kalpakkam, 603102, TN, India. Tel: 91-44-274-80500 ext 22491. E-mail: sivarama@igcar.gov.in Received: September 15, 2014 Accepted: September 30, 2014 Online Published: October 26, 2014 doi:10.5539/emr.v3n2p47 URL: http://dx.doi.org/10.5539/emr.v3n2p47 Abstract In 500 MWe Prototype fast breeder reactor (PFBR), instrumentation for Post Accident Monitoring (PAM) is provided for monitoring the status of core and Reactor Containment Building (RCB) in case of Core Disruptive Accident (CDA). The instrumentation for PAM provides the operator with the necessary information by monitoring and displaying critical parameters. This paper details the parameters and how they are monitored. Keywords: accident, pressure, sodium, activity, neutron 1. Introduction Energy is a vital component for development of economy and providing high quality of life to the citizens. In view of growing concerns on availability of resources, climate change and energy security, nuclear is a preferred option for providing sustainable energy. Among many nuclear energy systems, Fast Reactors (FRs) are the most efficient energy system for the effective utilization of uranium resources. In order to demonstrate the techno-economic viability of SFRs for the commercial exploitation, a 500 MWe Prototype Fast Breeder Reactor (PFBR) has been designed and developed. PFBR is under construction at Kalpakkam. The reactor is provided with two shutdown systems having diverse design features. 2. Scope Normal process upsets and Design Basis Events (DBE) such as transient over power are not considered as design basis events for the design of PAM. In addition, common mode events such as fire and flooding are not treated as PAM events. When there is mismatch of power produced and power removed from the reactor, with shutdown systems failing to respond to the demand, certain parameters such as temperature, pressure and gamma activity in the core raise, causing CDA. This leads to sodium boiling, core melting and pressure bubble formation in the main vessel. This results in sodium entry into RCB, raising the pressure, temperature and gamma activity in RCB. In case of anticipated plant occurrences, initial protection and mitigating actions are taken automatically by the plant protection systems. Instruments for PAM have ranges to cover the maximum values that can attain under worst-case conditions (i.e. under CDA, which is a beyond design basis event). The instruments are also qualified to survive the conditions associated with CDA, such as temperature, pressure and radiation level. When CDA occurs, parameters such as core neutron power, main vessel surface temperature, RCB sodium activity, RCB air temperature, RCB air pressure and gamma field inside RCB may rise to considerably higher levels. The role of Post Accident Monitoring System (PAMS) is to acquire the above parameters signals, compare the acquired signals with the threshold values and transmit the processed information & parameters values through Safety Class-2 data highway and generate alarms in control room. 3. Salient Features The signal processing channels are located outside RCB. The equipments (sensors and cables) are qualified for the extreme conditions expected in their lifetime and during CDA. The electronic instrument channels are qualified as per the applicable specifications for environmental and EMI/EMC conditions. Periodic surveillance is under taken on the instruments to keep them in healthy and calibrated condition. In order to know the instrument s healthiness, Good Operation Trip (GOT) is provided. 47

Hardwired outputs are brought to control room for indication and annunciation. All the parameters are isolated and fed to Safety Class II data highway for centralized display and logging. Galvanic Isolation is provided between the channels input and outputs and display in control room. Redundant instrument channels are powered with independent bus of Class II Uninterrupted Power Supply (UPS) Safety Classification: These instrument channels are classified as Safety Class II. Seismic Categorization: These channels are categorized as Seismic Category I. 4. Parameters and Instrumentation The instrumentation for Post Accident Monitoring (PAM) provides the operator with the necessary information during CDA, by monitoring and displaying critical parameters such as Core neutron flux, pressure, temperature, gamma and sodium presence in RCB air after CDA. The input signals (both analog and digital), terminated at cabinets located in Control building (CB) Local Control Centre (LCC) LCC 1 and CB LCC 2, and processed by separate Real time computer (RTC) systems. The parameters such as core neutron power, RCB sodium activity and gamma field inside RCB, main vessel surface temperature, RCB air temperature and RCB air pressure are processed by separate hardware processing units and signal conditioning modules. Each RTC acquires the above signals in the electrical range of 0.5V-9.5V & 0V-5V. The system compares the acquired signals with the threshold values entered from the process computer and generates alarms in the form of potential free contact outputs whenever the parameter crosses the set threshold value. Similarly analog outputs are generated to display the parameter physical value on recorder units located in control room (CR) Panel. Thereafter each RTC system sends the input signals, parameter values, alarms and health status of RTC system to SC-2 data highway. Table 1 details the parameters, ranges and their location. Table 1. Parameters monitored in post accident monitoring Parameter Range Type of the detector Location of the detector Core neutronic power 1% Pn to 200 Pn Two Fission Chambers Below the safety vessel Main vessel temperature (hot pool) Main vessel temperature (core catcher) RCB temperature 373 K to 1273 K (100 o C to 1000 o C) 373 K to 1273 K (100 o C to 1000 o C) 288 K to 373 K (15 o C to 100 o C) Two, 2 mm surface mounted K type thermocouples Two, 2 mm surface mounted K type thermocouples At the hot pool elevation EL 23520 At the core catcher elevation EL15401 3 wire RTD (PT 100) Inside RCB at EL 35600 and EL35700 Gamma field inside RCB Sodium presence inside RCB RCB Pressure 0.1 mr/h to 10 5 R/h (1µSv/h to 10 3 Sv/h) Two Ionization chambers 10 Bq/cc to 10000 Bq/cc Two scintillators with sample intake from RCB 70 kpa (abs) to 130 kpa (abs) Two pressure transmitters Inside RCB at EL35600 and EL35700 Outside RCB in CB at EL35600 and EL35700 Outside RCB in CB at EL35600 and EL35700 4.1 Core Neutron Flux Monitoring Measurement range is 10 3 n/cm 2 /s (nv) to 2x10 7 nv (12.5 MWt to ~ 200% of nominal power Pn). Two fission chambers with a sensitivity of 0.1 cps/nv are located under the safety vessel. Mineral insulated cables from these detectors are connected to the super screened cables (carrying signal over +HV). These cables are routed to CB-LCC where the instrument channels are located. 4.2 Main Vessel Temperature Monitoring Measurement range: 373 K to 1273 K (100 o C to 1000 o C). The main vessel temperature monitoring system 48

consists of 2 mm dia surface mounted K type thermocouples (T/C), two each, located at the elevation of hot pool and core catcher. The thermocouples are terminated in a junction box on the roof slab. T/C extension cables are used from the junction box upto the RCB penetration and from the other side of penetration to CB LCC where signal processing units are located. 4.3 RCB Air Temperature Monitoring Measurement range is 288 K to 373 K (15 o C to 100 o C). The RCB air temperature monitoring system consists of Platinum RTDs (two no.). The signals are routed to CB LCC where signal processing units are located. 4.4 RCB Gamma Monitoring Gamma field inside RCB may go upto a maximum of 10 5 R/h during CDA. Two gamma monitors are provided. Measurement range is 0.1 mr/h to 10 5 R/h (1 µsv/h to 1000 Sv/h). The Channel for gamma monitoring consists of Ionization Chamber with a sensitivity of 10-11 A/(R/h) and two super-screened cables (carrying signal and HV) coming from the ionization chamber to the instrument channel in CB LCC. 4.5 Detection of the Presence of Sodium in RCB During CDA, active sodium enters RCB atmosphere. Sensors and electronics are provided to monitor the presence of active sodium (Na 24 activity) in RCB air from 10 Bq/cc to 10,000 Bq/cc. Air sample is drawn from RCB at two locations in CB through 25 mm OD SS tubing by means of Dry Carbon type vacuum pump and brought to the detector. Sampled air is returned back to RCB. Gamma channel with Scintillator detector of sensitivity 1 cps/(bq/cc) with preamplifier is located in the sampling line. Cables (one for signal and other for power supplies/ control signals) coming from the preamplifier are connected to the instrument channel in CB LCC. Sampling arrangement is shown in Fig. 1. During and after CDA, an abnormal increase in Sodium concentration is expected in the air within the RCB. A sample of air from RCB is drawn at by means of a sampling pump and a sampling pipeline. The air sample is passed continuously through a gas chamber of the monitor, in which detector is placed to detect the activity due to sodium concentration. The Electronics Processing and Display Unit of the monitor is located in CB-LCC1/CB-LCC2. The monitor provides instantaneous Sodium Aerosol gamma activity concentration display on front panel and analog signal output for display / paperless recorder in control room. The monitor provides relay contact output for the alarm conditions of the signal and also Good Operation Trip contact output for annunciation in control room. 49

Figure 1. Sampling & monitoring system of sodium in RCB 4.6 RCB Pressure Monitoring Absolute pressure transmitters are connected to the sample intake point, provided for monitoring the presence of sodium and the signal processing electronics are located in CB LCC. Each sampling line is provided with pressure transmitters. 5. Safety Analysis Healthiness of the instrument channels of PAMS is a pre-requisite for reactor start-up. Provision is made for monitoring healthiness continuously. Dual sensors are provided for each parameter. Redundant instrument channels are fed from independent divisions of Class II UPS, 240 V AC. System is designed in such a way that no active components of post accident monitoring instrumentation (solid state electronics) are present inside RCB, which are expected and required to be qualified to work during and after CDA. 50

References IEC 951 (Parts 1 to 5). (1994). Nuclear power plants Radiation monitoring equipment for accident and post accident conditions. Instrumentation and equipment for monitoring and controlling NPP post accident situations. (1995). IAEA-IWG- NPPCI-95/12. IS 14481 (Part 1). (1998). Radiation Monitoring Equipment for Accident and Post-Accident Conditions. Nuclear Power Plants. Instrumentation and Control Systems Important to Safety in Nuclear Power Plants (2002). IAEA Safety Standards Series, Safety Guide NS-G. Copyrights Copyright for this article is retained by the author(s), with first publication rights granted to the journal. This is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). 51