Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

Similar documents
Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

Smoke is the most deadly part of a fire.

BuyLine /CON. apcdayliter. Fire and Smoke Vents. Smoke is the most deadly part of a fire

ICC CODE CORNER 2012 IFC Code & Commentary

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

MULTI-LEVEL & COVERED BOOTH CONDITIONS

New Facilities. Minimum Requirements

SECTION WET-PIPE SPRINKLER SYSTEMS

Submittal Data Performance Data Electrical Data

Report on First Revision June 2014 NFPA 5000

5 Key Stages to Risk Assessment

A. Product Data: Include rated capacities, furnished specialties and accessories.

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

The Owner will provide the QEI inspection and certification services.

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

El Reno Fire Department Fire Alarm Plan Review Worksheet

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Module 7. Control of Smoke & Highlights of Code Requirements

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

SECTION AIR DUCT ACCESSORIES

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Redlands Fire Department Fire Protection Standard

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

B. Section Identification for Fire Suppression Piping and Equipment.

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Direct Fired Heater Model AD Specification

Stillwater Area Community Services Center Inc.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Fire Safety PPT-SM-FIRESFTY V.A.0.0

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

OFF-RIDGE VENTILATION PRODUCT BROCHURE

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

a) Establishment of emergency procedures to be followed at the time of an emergency;

RISKTOPICS. Photovoltaic systems

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Builders Risk - Fire Prevention Inspection Checklist

1893 Chicago World s Fair

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Working safely with flammable liquids

CHAPTER 7 ALTERATIONS LEVEL

SECTION AIR DOORS

Osceola County Department of Fire Rescue and Emergency Medical Services

Level I Chapter 1 Worksheet

HOT WORK OPERATIONS March 23, 2018

- CONSTRUCTION FIRE SAFETY STANDARDS

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

IN020 Rev F Page 1 of 8

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION Fire Pumps

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS

rpsa FIRE PROTECTION ENGINEERS

Code Technology Committee Area of Study Balanced Fire Protection Roof Vents

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

Department of Public Safety

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Fire Prevention Plan

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Family Foster Home Fire Safety Evaluation Checklist Instructions

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Installation and Maintenance Instructions

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

DEPARTMENT OF FIRE AND EMERGENCY SERVICES

Special Occupancy Requirements

Chimney Fire Prevention

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

Fire Prevention Plan

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Large Family Daycare Guideline

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Emergency Planning and Preparedness

Safety Policy and Procedure

THE TRUE FIRE SURVIVAL CABLE

Corn Flame Energy Corn Stove Model 3000

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Fire Investigation Terms

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Transcription:

Moffitt Firex Heat & Smoke Ventilator Page 1 of 8 1351 13th Ave S. Suite 130 Jacksonville Beach, FL 32250

Moffitt Firex Table of Contents Moffitt Firex Table of Contents...2 Moffitt Firex Product Details...3 Moffitt Firex Submittal Data...4 Moffitt Firex Designing for Smoke Relief...5 Moffitt Firex The Need for Fire Venting...6 Moffitt Firex Pictures...7 Moffitt Firex Guide Specification...8 Since 1961 Page 2 of 8

Moffitt Firex Product Details STANDARD FEATURES Closed Height: 15 ¾ Opening width: 4 Opening length range: 4-8 Venting area range: 16 ft 2-54 ft 2 Wind uplift: 120 psf Snow load: 10 lbs./ft 2 Net weight range: 345 lbs. Galv. - 590 lbs. Galv. Automatic or Manual Operator UL Listed, UL 793, Automatically Operated Roof Vents for Smoke & Heat FM Approved Aluminum Door Panels OPTIONAL FEATURES Burglar alarms E.T.L. links Solenoids Polycarbonate Door Panel BENEFITS Doors open automatically when subjected to elevated temperatures from fires. Doors have a positive lock in the open position against untimely closing. Double-wall doors have laminated honeycomb insulation between steel walls to protect against condensation and heat loss. Low-profile design does not detract from the architectural concept or modern buildings APPLICATION Foundries Chemical plants Paper mills Rubber products General warehouses Theatres Performance Halls Leather goods manufacturing Printing presses Machine shops w/ combustible chemicals Metal stamping plants Machine shops Painting departments Oil quenching Breweries Food handling Emergency Stairwells DESCRIPTION The Moffitt Firex is an economical venting system designed to restrict fire from spreading by extracting heat and smoke, and in turn protecting the building and contents. It also provides additional, often vital, access for fire fighters. Large industrial and storage buildings with extensive undivided floor areas can make firefighting difficult. Heat responsive ventilation equipment can make firefighters jobs safer and more effective. The National Fire Protection Association (NFPA) has performed full scale testing that proves the addition of proper ventilation will assist fire fighters in accessibility of the source of the fire and to take direct action against it thereby reducing overall damage to the building. Moffitt Firex Heat and Smoke Ventilators have been manufactured continuously since 1956. During this time, tens of thousands of ventilators have been produced and designs have been constantly upgraded and improved. Page 3 of 8

Moffitt Firex Submittal Data STANDARD FEATURES Closed Height: 15 ¾. Opening width: 4 Opening length: 4-8 Venting area: 16-54 ft 2 Net weight: 345 lbs. Galv - 590 lbs. Galv Wind uplift: 120 psf Snow load: 10 lbs./ft 2 Automatic or Manual Operator Aluminum Door Panels OPTIONAL FEATURES Burglar alarms E.T.L. links Solenoids Polycarbonate Door Panel MODULE NUMBER INSIDE DIMENSIONS ( W L ) VENT AREA ( FT 2 ) NET WT. ( LBS) FX-44 48" x 48" 16 345 FX-45 48" x 60" 20 380 FX-46 48" x 72" 24 415 FX-47 48" x 84" 28 450 FX-48 48" x 96" 32 485 FX-55 60" x 60" 25 425 FX-56 60" x 72" 30 465 FX-57 60" x 84" 35 520 FX-58 60" x 96" 40 540 FX-66 72" x 72" 36 525 FX-67 72" x 84" 42 545 FX-68 72" x 96" 48 565 FX-69 72" x 108" 54 590 Page 4 of 8

Moffitt Firex Designing for Smoke Relief The proper size and quantity of fire ventilators required is generally based on the occupancy class of the building relating to the combustible nature of its contents. Listed below are general classes of occupancy and recommended vent areas. These are intended as a general guide only and designers should consult NFPA 204M or Moffitt if specific questions arise. HOW TO SPECIFY 1. Determine total square feet in space to be protected. 2. See Table (1) to determine classification of occupancy, i.e. low, moderate or high. 3. See Table (2) to determine floor area protection required in square feet. OCCUPANCY TYPES LOW MODERATE HIGH Metal Stamping Automobile Assembly Rubber Products Machine Shops Leather Goods Mfg. Paper Mills Foundries Printing Presses Chemical Plants Breweries Combustible chemicals areas Painting Areas Food Processing Warehouses Oil Quenching Type of Occupancy Based on Heat Release Max. Distance between center lines of any two vents Max. Ratio of effective vent area to floor area Venting requirements based on tests and experience compiled by the national fire protection association (NFPA) Building designers and fire protection engineers cannot rely on casual inclusion of skylights, windows, or monitors as adequate venting means. The vent opening should measure at least four (4) feet in any direction. Opening mechanism must operate automatically in the event of a fire, without the use of electricity. All automatic vents should be designed to also open manually. Opening mechanisms must be made of non-corrodible materials. Vents are not a substitute for sprinklers or other fire extinguishing equipment. Vents should remain securely closed against internal pressure build-up during wind and rain storms. Vents should be regularly inspected and manually tested to assure proper operation. The fusible link should never be painted or tampered with. In the case of gravity operated vents (dropout panels) the vents should be kept clean of dirt, airborne debris, ice, and snow to insure proper operation. Vent spacing should be based on the building occupancy and the heat release potential of the contents as detailed in NFPA 204M dated 1991. Noncombustible curtain boards should also be utilized inside a building to assist in directing smoke and heat towards the vents for relief. Vent spacing should be based on building occupancy and the heat release potential of the contents. Table 1 Max. Area in sq. ft. per 32 ft 2 FIREX Low 150 1:150 4800 Moderate 120 1:100 3200 High 75-100 1:30-1.50* 960-1600* Table 2 Page 5 of 8

Moffitt Firex The Need for Fire Venting Without MOFFITT FIREX heat & smoke ventilator Solid Roofs Spread Heat & Flames HOT AIR & SMOKE IN RUSHING AIR TYPICAL SPRAY REACH 50 75 When floor areas are large there is a rapid lateral fire spread in an un-vented building. Temperature rise in a building without fire ventilation was over three times the temperature rise in the building with fire venting. Where fire venting was absent, the temperature exceeded that point at which the structural steel would become buckled and distorted. The hot gases from a fire which involves only part of the floor area of the building rise to the ceiling and form a layer which does not usually mix to any extent with the underlying cold air. The layer of hot gases will gradually build down to floor level. With MOFFITT FIREX heat & smoke ventilator Ventilated Roofs Allow Smoke & Heat to Escape VENT VENT VENT VENT PREVENTS SMOKE LOGGING: FIRE ORIGIN First and foremost, by automatically releasing the heat, smoke and general products of combustion Fire venting enables firemen to see the fire, to approach the source and tackle it without breathing apparatus. PREVENTS EXPLOSION: Automatic fire venting quickly removes the partially burnt gases which would otherwise accumulate in the roof space and present a danger of explosion. REDUCES LATERAL SPREAD OF FIRE: By preventing heat from mushrooming over the fire area and heating materi als to the point of ignition, fire venting has a marked effect on reducing the lateral spread of fire. REDUCES WATER DAMAGE: By enabling jets to be applied straight onto the fire, instead of being directed generally towards the smoke logged areas. Fire venting reduces water damage throughout the building. Furthermore, where fire venting is used in conjunction with sprinkler systems, the prevention of lateral heat spread reduces the number of sprinkler heads in operation to only those directly centered over the fire. LIMIT ROOF TEMPERATURE: A well designed fire venting system will limit the temperature in the roof space of a building to well within the softening temperature of structural steel. This prevents distortion and collapse of the building. Heat and smoke venting keeps temperatures from reaching extremes that can ultimately result in keeping the building standing. Page 6 of 8

Moffitt Firex Pictures Page 7 of 8

Moffitt Firex Guide Specification 1.1. DESCRIPTION: Furnish and Install Moffitt Firex heat and smoke ventilators and accessories as indicated on drawings. Moffitt Firex is a registered trademark of Moffitt Corporation, Inc. 1.2. QUALITY ASSURANCE: MOFFITT (Jacksonville, FL, 1-800-474-3267) Products establish the standard of quality required. Manufacturer and erector shall demonstrate a minimum of five (5) years of related industry experience. 1.3. SUBSTITUTIONS: No substitutions will be considered unless written request for approval has been submitted by the bidder and has been received by the designer at least ten (10) days prior to bid date. Any proposed substitutions should meet the standards set by the specification. 1.4. SUBMITTALS: Furnish approval drawings prior to fabrication and erection drawings prior to shipment showing all erection procedures and accessories required for the specified product. 2.1. DESIGN Moffitt Firex heat and smoke ventilators shall be designed for airflow capacities as shown in the submittal data (page 3 of this catalog). 3.1. INSPECTIONS Examine roof curb prior to installation to ensure a true flat mounting condition. Make sure flat surface of curb is clear of debris to ensure proper adhesion of caulking material between vent and roof curb. Examine alignment of Moffitt Firex modules it has been installed as per installation instructions. roof 3.2. INSTALLATION & ERECTION Install Moffitt Firex heat and smoke ventilator and accessories in conformance with approved drawings and MOFFITT specifications. 3.3. DAMAGED MATERIAL Repair or replace all damaged material. Page 8 of 8