Product Specification

Similar documents
Product Specification

Product Specification

OPTICAL AMPLIFIERS SELECTION GUIDE

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

LaserPlus Model LP-OA EDFA OPERATING MANUAL

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Features

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

OPTICAL FIBER SOLUTIONS

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

FIRERAY 5000 range USER GUIDE

Set-Up Procedures. Before You Start

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

VIEW500 FASTEST STANDARD OTDR

PONA 3000 Series High Power EDFA User s Guide

EPON ONU Optical Transceiver SFF Module

VIEW500 USER-FRIENDLY STANDARD OTDR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

T3/E3 Fiber Optic Line Drivers

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

Cooled Butterfly 980nm Pump Laser Module

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Fiber Optics and Liquid Level Sensors Line Guide

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

Indium Gallium Arsenide Detectors

MINI2 MOST ACCURATE COMPACT OTDR

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Noyes OFL 250B Specs Provided by

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

MTTplus Modular Test Platform

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

ETH1000-MKII. User manual

G4 Pulsed Fiber Laser

OVEN INDUSTRIES, INC.

OTDR. Optical Time Domain Reflectometer. User Guide

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

3kW 6kW, QUBE Fiber Lasers

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Fiber Optical Multiplexer

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Analog Input Module IC670ALG630

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Rack Mount High-Power EDFA Installation Guide


ETH1000-D. User manual

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Advance Optima Module Magnos 17

1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features

Clearlite Photonic Fibers

OFS IV Optical Fibre System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Dual SDI Optical to Electrical Converter

Advanced Fiber Optic Test Equipment Terahertz Technologies Inc.

4120 Fire Alarm Network Reference

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

Key Features. General Description

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

palmotdr Series Handheld OTDR

I/A Series 716C 1/16 DIN Temperature Controller

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

High cost performance choice

MT-RJ Optical Fiber System Field Testing

Transcription:

Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain EDFA with control electronics APC or AGC control modes Flat spectrum over gain range of 15-30 db Power up to 17 dbm Low noise figure Standard 70x90 package Standard command protocol according to IEC 61291-6-1 Low power dissipation RoHS compliant and lead free Class 1M* laser safety classification Applications Regional, metro and access DWDM networks ROADM line cards Booster, Pre-amp or Inline The M7300CD Variable Gain (VG) EDFA is a micro processor-controlled module for C-band amplification. It is packaged in a standard 70x90 multi-source amplifier package, meaning that it can be mounted on any line card already designed to accommodate a multi-source EDFA. The amplifier quickly reacts to network conditions as they unfold, seamlessly adjusting to variations in the system conditions of Metro and Long Haul environments in real-time. It can accommodate a wide variety of network topologies, fiber spans and fiber losses, thereby reducing the number of amplifier types needed for deployment in any given network environment. The amplifier provides gain flattening and low noise figure in all its operational regimes. Its fast AGC allows the amplifier to keep the gain constant also in cases when there is a fast and large change in the input power. Finisar Corporation 2014 Page 1

Optical Specification Units Specification Min. Typ Max. Wavelength Bandwidth Nm 1529.5 1564 Input Power Range With Transient Suppression -28 +5 Monitoring Only -38-28 Notes The lower 3dB range has detection accuracy of +/-1dB Power Range dbm -8 17 Signal power, excluding ASE Saturated Power dbm 17 With ASE output is higher. Gain range db 15 30 Noise Figure G=30dB db 5.5 G 27dB db 5.7 G 24dB db 6.0 G 21dB db 6.6 G 18dB db 8.5 G 15dB db 11.5 Gain Stability db ±0.10 At Tilt = 0dB Settable tilt db -2 +2 Positive tilt for G below 28dB Gain Setting Accuracy db -0.25 +0.25 Gain Flatness vs. Wavelength db ± 0.5 ± 0.6 Overshoot/Undershoot for 16dB Add/Drop transient db ±1.5 Stabilization Time after transient µsec 500 Transient Error Band db 0.5 In/Out Return Loss (pumps on) db 40 PDG + PDL db 0.3 PMD ps 0.3 Power Measurement Accuracy db ± 0.5 Optical Connectors The EDFA is equipped with 3 Optical connections with fiber length of 100 +/- 5cm. Connector Type Color Description LC/UPC White optical port Input LC/UPC Black Input optical port Monitor LC/UPC Blue 1% monitor Finisar Corporation 2014 Page 2

Electrical Specification Units Specification Notes Min. Typ Max. Supply voltage V 4.75 5.25 Power consumption W 10 Over case temp range to EOL Electronic Pin-out Pin Function Pin Function 1 5V 2 5V 3 N/C 4 N/C 5 Ground 6 Ground 7 Serial Input RS232 (LVTTL) 8 Serial RS232 (LVTTL) 9 Ground 10 Ground 11 N/C 12 RESET Input (Active Low) 13 Pump Disable (Active High) 14 Power Mute Input (Active High) 15 Case Temperature Alarm (Active High) 16 Common Alarm (Active High) 17 N/C 18 Pump Bias Alarm (Active High) 19 Loss of Input Alarm (Active High) 20 Loss of output alarm/mute Alarm (Active High) 21 N/C 22 N/C 23 N/C 24 N/C 25 Ground 26 Ground 27 N/C 28 N/C 29 5V 30 5V Control and Monitoring Communications Mode of Operation Monitoring Functions RS232 Command Protocol Specification Automatic Gain Control (Default startup mode) Automatic Power Control Manual pump power Power Monitoring Input Power Monitoring LD and PCB Temperatures Finisar Corporation 2014 Page 3

Block Diagram Input VOA Monitor Input Detector Pump Detector Control Electronics Serial Interface Mechanical Drawing The following drawing shows the EDFA s width, height and length dimensions. Finisar Corporation 2014 Page 4

Environmental and Qualification Operating Case Temperature 0 C to +70 C Operating Humidity 5 to 85% Storage Temperature -40 C to +85 C Storage Humidity 5 to 95% Qualification Value/Range Telecordia GR1312 Laser Safety Class 1M* * Class 1M products are not hazardous under normal circumstances, but may pose an eye hazard when the laser output is viewed with certain optical instruments (for example eye loupes, magnifiers and microscopes) within a distance of 100 mm Finisar Corporation 2014 Page 5