Sprinkler Permit Applications

Similar documents
PLAN REVIEW CHECKLIST

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

Center for Life Safety Education

APPENDIX H (DESIGN SUBMISSION CRITERIA)

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

What You Need to Know about Residential Sprinkler Design

DIVISION 21 - FIRE SUPPRESSION

What Builders Need to Know about Residential Sprinkler Design

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

AUTOMATIC FIRE SPRINKLER SYSTEMS

FIRE SPRINKLER SYSTEMS POLICY

New Construction Fire Inspection Process

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

FIRE SPRINKLER SYSTEMS POLICY

DIVISION 21 - FIRE SUPPRESSION

CITY OF PASADENA FIRE DEPARTMENT

MONTECITO FIRE PROTECTION DISTRICT

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Fire Sprinkler System Design and Installation Requirements

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

SECTION SPRINKLER SYSTEMS

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Fire Sprinkler Submittal Requirements and Acceptance Testing

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

Port of St Helens SIA Aircraft Hanger Scappoose, OR

SECTION WET-PIPE SPRINKLER SYSTEMS

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Sprinkler Standards Proposed Technical Changes

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Sprinkler System Installer Level 2

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

Fire Protection Coffee Break Training August 2016

SECTION WET-PIPE SPRINKLER SYSTEMS

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Fire District Dwelling Construction Requirements

SECTION WET-PIPE SPRINKLER SYSTEMS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

Gas Station & C Store SECTION CWM Job No

NFPA Edition Update

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

SECTION DRY-PIPE SPRINKLER SYSTEMS

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Fire Sprinkler Plan Submittal Form

HELP THEM PROTECT THEIR WORLD.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

DIVISION 21 FIRE SUPPRESSION

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

PLAN REVIEW SUBMITTAL GUIDE

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO., LTD.

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

DUCT SYSTEMS CHAPTER 6

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Fire Permit Application

Best Practices Guide. for Residential Fire Sprinklers

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SPRINKLERS TABLE OF CONTENTS

FIRE SUPPRESSION SPRINKLER SYSTEM

Residential Care Facilities Requirements

SECTION : FIRE PROTECTION SYSTEMS

Florida Building Code 2010

SENJU SPRINKLER CO., LTD.

City of Vista Fire Department

NEW MEXICO STATE FIRE MARSHAL S OFFICE

CHAPTER 7 ALTERATIONS LEVEL

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

Transcription:

REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations shall include a summary, detailed work and graph sheet 1. Summary sheet to include: name of owner, date and location hazard classification name and address of contractor, designer approving engineer density, flow and pressure data 2. Work Sheets: sheet number sprinkler description and discharge constant ( K factor) hydraulic reference points, flow (gpm), pipe size, pipe lengths equivalent pipe lengths, friction loss per foot of pipe, total friction loss, elevation head between reference points, required pressure at each reference point, notes to indicate starting point 3. Graph Sheet: water supply curve sprinkler system demand hose demand (where applicable) in-rack sprinkler demand (where applicable) Additional information required 1. System Design Requirements: rate of water application (density) area covered by each sprinkler design area clearly identified on drawings total water requirements as calculated, including allowance for inside hose, outside hydrants, water curtains and exposure sprinkler allowance for in-rack sprinklers limitations (dimension, flow and pressure) on extended coverage or other listed special sprinklers 2. Water Supply Information: location and elevation of static and residual test flow location, static pressure, residual pressure, flow, date specify if test conducted or is information supplied by others G:\DSDSystem\Handouts\Building\SprinklerPermitGuide.docx Page 1 of 5

REQUIREMENTS FOR NFPA 13R SYSTEM NFPA 13R: Residential up to and including four-storey apartments Lodging and rooming houses Board and care facilities (16 or fewer slow-evacuation and prompt-evacuation types) Hotels, motels and dormitories NFPA 13R Requirements: 1. Working plans are to be submitted to the authority having jurisdiction before any equipment is installed or remodelled and shall not be deviated from without the approval of the authority having jurisdiction. 2. Working plans will show the following information: name of owner and occupant street address of the project the ceiling construction location of partitions and fire walls occupancy of each area or room location and size of concealed spaces, attics, closets and bathrooms any small enclosure to which no sprinklers are to be installed size, pressure and city main test results make, manufacturer, type, heat-response element, temperature rating and nominal orifice size of the sprinkler temperature rating and location of high temperature sprinklers number of sprinklers on each riser per floor type and location of alarm bells type of pipe and fittings type of protection for non-metallic pipe nominal pipe size with lengths shown to scale location and size of riser nipples types of fittings and joints and the locations of all welds and bends types and locations of hangers, sleeves, and braces and methods of securing sprinklers, where applicable all control valves, check valves, drain pipes, test connections and FDC location underground pipe size, length, location, weight, material, and point of connection to the city main: type of valves, meters, and valve pits, and the depth at which the top of the pipe is laid below grade material to be included on the hydraulic data nameplate The installer shall perform all required acceptance tests, complete the Contractor s Material and Test Certificate(s) and forward the certificate(s) to the authority having jurisdiction prior to asking for approval of the installation. G:\DSDSystem\Handouts\Building\SprinklerPermitGuide.docx Page 2 of 5

REQUIREMENTS FOR NFPA 13D SYSTEM NFPA 13D: A minimum standard for single family dwellings, duplexes and mobiles homes. Sprinklers are not required in garages, open attached porches, carports and similar structures. Sprinklers are not required in attics, crawl spaces and other concealed spaces that are not intended for living or storage. Sprinklers are not required in clothes closets, linen closets and pantries where the floor area does not exceed 24 square feet and the least dimension does not exceed 3 feet. Limited Area Design method can be used for single story buildings and manufactured homes if not more than 2,000 square feet. NFPA 13D Requirements: 1. Working drawings are to be submitted to the authority having jurisdiction before any equipment is installed or remodelled and shall not be deviated from without the approval of the authority having jurisdiction. Design and drawings for this type of system may be undertaken by licensed sprinkler installers acceptable to the authority having jurisdiction. 2. Working drawings will show, but not limited to, the following information: the name of owner and occupant the street address of the project the ceiling construction the location of rooms and partitions (compartments) identify the compartment and number of sprinklers involved for the design identify areas where no sprinklers are to be installed show location of water flow alarm (exempt if building equipped with smoke detectors in accordance with NFPA 72) dimension sprinkler head spacing and floor area coverage dimension size of piping location and layout of valve station 3. Calculation sheet will provide the following minimum information: the minimum sprinkler head pressure and flow (gpm) at the most remote head the minimum flow to each head in a multiple head design number of sprinkler heads in design compartment verify water demand requirements (# of heads x calculated discharge per head) list the city water pressure and flow at street provide calculations for pressure losses for meter, elevation differences, underground piping, piping within the building to the farthest sprinkler head and all fittings from the control valve to the farthest sprinkler verification that the supply pressure exceeds the required pressure for the design sprinklers G:\DSDSystem\Handouts\Building\SprinklerPermitGuide.docx Page 3 of 5

REQUIREMENTS FOR ALTERATIONS TO EXISTING SPRINKLER SYSTEMS WITHIN EXISTING SPACES Minor alterations include: Work not affecting branch pipe sizes, in hydraulically calculated systems (no alterations allowed in a hydraulic design area). Additions of a maximum of 8 heads (outside the design area only), or relocation of a maximum of 20 heads (including the 8 maximum sprinkler heads to be added). Turning heads up or down to accommodate a new ceiling, including additional heads in a newly created concealed space above the ceiling. Areas where there is no change in use or hazard classification. Permit requirements for minor alterations (Note that plans may be designed by a qualified sprinkler installer): Floor plan of area affected by alteration 1/4":1 scaled drawings. Number and location of heads to be installed or relocated. Number and location of heads to be raised, lowered, removed or replaced, including type of heads to be installed. Changes to pipe sizes in pipe schedule system as per table 6-5.2.3 NFPA13, name, phone number and trade qualification number installer. Major alterations include: Work including changes to branch pipe sizes in a hydraulically calculated system, work on the valve station. Additions or relocation of more than 8 heads excluding additions of heads to sprinkler concealed spaces created by adding a ceiling. Additions of any head inside the design area. Permit requirements for major alterations: Floor plan of area affected by alteration, number and location of heads to be installed or relocated. Number and location of heads to be raised, lowered, removed or replaced, including type of heads. Changes to pipe sizes. Hydraulic calculation where changes are inside design area. Schedule B, provided by a mechanical engineer. Note that: No work is permitted until the building/sprinkler permit is issued. Verification of annual testing and/or a mechanical engineer s review of the overall system may be required. The Building Section reserves the right to determine whether a project is a major or a minor alteration. As-built drawings are required for installations not conforming to approved drawings. G:\DSDSystem\Handouts\Building\SprinklerPermitGuide.docx Page 4 of 5

MAJOR SPRINKLER COMPONENTS TO BE INSPECTED Included, but not limited to: 1. Fireline Inspection (Underground) underground certificate witness flushing witness 200 lb. test rodding and thrusting blocks pipe materials bedding materials depth of cover verify appropriate certification of materials (UL/ULC) 2. Rough In (Sprinkler) conformity to approved plans (must be on site) above ground certificate complete with trades qualification valve station configuration hangers seismic restraint obstructions drains fire department connection location of hydrant 3. Final Inspection (Sprinkler System) alarm verification bucket test (13D only) securing valves trim completion obstruction operating manuals (inclusive of shop drawings, cut sheet of devices, recommended maintenance schedule and name, phone number and address of installer) and/or fire safety plan Schedule C-B from design professional G:\DSDSystem\Handouts\Building\SprinklerPermitGuide.docx Page 5 of 5