PRODUCT RANGE: ROOFTOP PACKAGE

Similar documents
Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Ducted Split System Air Conditioners Technical Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Advance Release September 2009

Air Cooled Packaged Systems AIRAH Back to Basics

Technical Data Ducted Three Phase Split System Air Conditioner

Indirect Evaporative Air Conditioning

Indirect Evaporative Air Conditioning

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

PAR5. Product Specifications

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Ducted Split System Air Conditioners Technical Data

VertiCool Aurora Engineering Guide

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Packaged Air Conditioning Custom Build Solutions

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Pool heating, efficiently

Submittal Summary Page

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance


C13-Series Engineering Guide

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

QUANTUM. Reliable solar hot water, whenever you want it

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Multi-Path RTU-TYPE 2

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

NFZP Variable Refrigerant Flow Guide Specification

VariCool VAV Engineering Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

62DA,DB,DC,DD,DE,DF07-38

Product Data. Fig. 1 - Unit 50VG -A

technical guide Water-Cooled Self-Contained Units

ELECTRICAL QUANTITY WEIGHT (LB)

MAC N-407 Air-Cooled Chiller

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Air Cooled Packaged Units

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MACH N-407 Heat Pump Air-Cooled Chiller

Product Line Introduction. Karl Zhang Technical support engineer

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

VENTILATION. Effective heat exchange and fresh air ventilation

Product Data KUWAIT SERIES

EHH SERIES DRAW THROUGH FAN COILS CFM

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Submittal Data Performance Data Electrical Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Now In Production JULY 2008

WPH4 Product Specifications

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

ULTRATEMP HIGH PERFORMANCE HEAT PUMP

ROOFTOP PACKAGED AIR CONDITIONERS

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

RT-OA TM Rooftop Outdoor-Air (DOAS)

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Highly Efficient,Powerful Heating and Cooling.

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Air Cooled Scroll Chiller / Heat Pump

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Air-Cooled Condensing Units with Compact Screw Compressors

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

CoolSpot Engineering Guide

PAJ3. Product Specifications

General Description. Operation

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Air to Air Heat Exchanger

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Transcription:

Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They have the benefit of energy reclaim, packaged with a direct expansion system into one single unit. Energy Efficient Construction Cabinets are constructed of 50 mm BHP Colourbond Sandwich panel, for best practice insulation. Purpose built UV treated polymer joiners are used to eliminate heat loss through the body of the unit. The Counter flow Enthalpy heat exchanger that will be incorporated into the unit will reclaim up to 75% of the energy from the exhaust stale air, therefore saving up to 75% of the cost to heat or cool outdoor air. Counter flow Sensible heat exchanger with 80% efficiency on sensible only is available at no additional cost. Air Change units are designed with extremely large access doors to ensure that all parts are accessible for servicing and replacement. The Exhaust and Supply fans forward curved centrifugal, direct coupled, fans with tropic proof motors from their respective manufacturer. Fan speeds are adjusted via separate ABB VSD controllers. Fan housings will be rubber mounted to reduce vibration being transmitted to the body of the unit.

Rooftop Compressors are Danfoss scrolls, to ensure the highest efficiency and quality. The unit has an automatic lock out on power failure, low pressure control automatic reset, and high pressure control automatic reset after latching relay reset from control board. Phase protection is standard across all Rooftop Packaged unit to protect compressors on miss wiring events De ice control is electronic and operates on a time-selected basis to energise at 3ºC and off at 10ºC coil temperature A Choice of R-22 or R-407C refrigerant circuits Fans incorporating three phase fan motors (20kWr and over) are direct coupled, therefore eliminating the need for pulleys and belts. Small Rooftop Packaged Unit (11-16kWr) incorporates direct drive fan and motors with a choice of 3 speeds for easy airflow commissioning Supply and exhaust air three phase fan motors are controlled with separate VSD controllers with benefits including; i. Ramped starting of fan motors, leading to a prolonged life of all fan and motor components and eliminate starting power / amperage spikes. ii. Dramatically reduced commissioning times as airflow is tuned simply by adjusting fan speed through VSD control panel or by analogue inputs for modulating fan speed. iii. Easy integration to a BMS system iv. Saves running costs by precisely controlling power needed to the motor v. Optional Modbus adapter for high level communication vi. HVAC series VSD s are available for BacNet communication.

Options Options RA Bypass Used in high load or startup conditions. Allows the unit to run with as low as 50% fresh air thus reducing the fresh air load of the system. Motorized damper optional. Economy Cycle Used in comfortable ambient conditions. Fresh air bypasses the heat exchanger, optimising energy saving throughout the year. HVAC series VSD s Available on 20kWr and above Rooftop Packaged Unit, HVAC series VSD s for high level communication with BMS system Hot/Cold water coil Rooftop package units can incorporate hot or cold water coils to optimise capacity. De-superheater Reclaim energy from refrigerant to heat water. Suits a variety of applications. High Static Fan Upgrade Fan upgrades available for high flow or high external static pressure drops. Compressor Upgrade Upgrade your compressors to increase refrigerant output. Corrosion Resistant Corrosion resistant packaging available for harsh and corrosive environments Sensible Only Heat Exchanger 80% sensible transfer efficiency for dry climates or any specialist applications.

Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kw With Energy Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They have the benefit of energy reclaim, packaged with a direct expansion system into one single unit. Energy Efficient Construction Cabinets are constructed of 50 mm BHP Colourbond Sandwich panel, for best practice insulation. Purpose built UV treated polymer joiners are used to eliminate heat loss through the body of the unit. The Counter flow Enthalpy heat exchanger that will be incorporated into the unit will reclaim up to 75% of the energy from the exhaust stale air, therefore saving up to 75% of the cost to heat or cool outdoor air. Counter flow Sensible heat exchanger with 80% efficiency on sensible only is available at no additional cost. Air Change units are designed with extremely large access doors to ensure that all parts are accessible for servicing and replacement. The Exhaust and Supply fans are fully coated forward curved centrifugal, direct coupled, fans with tropic proof motors from their respective manufacturer. Fan speeds are adjusted via separate ABB VSD controllers. Fan housings will be rubber mounted to reduce vibration being transmitted to the body of the unit.

Rooftop Compressors are Danfoss scrolls, to ensure the highest efficiency and quality. The unit has an automatic lock out on power failure, low pressure control automatic reset, and high pressure control automatic reset after latching relay reset from control board. Phase protection is standard across all Rooftop Packaged unit to protect compressors on miss wiring events De ice control is electronic and operates on a time-selected basis to energise at 3ºC and off at 10ºC coil temperature A Choice of R-22 or R-407C refrigerant circuits Fans incorporating three phase fan motors (20kWr and over) are direct coupled, therefore eliminating the need for pulleys and belts. Small Rooftop Packaged Unit (11-16kWr) incorporates direct drive fan and motors with a choice of 3 speeds for easy airflow commissioning Supply and exhaust air three phase fan motors are controlled with separate VSD controllers with benefits including; i. Ramped starting of fan motors, leading to a prolonged life of all fan and motor components and eliminate starting power / amperage spikes. ii) Dramatically reduced commissioning times as airflow is tuned simply by adjusting fan speed through VSD control panel or by analogue inputs for modulating fan speed. iii) Easy integration to a BMS system iv) Saves running costs by precisely controlling power needed to the motor v) Optional Modbus adapter for high level communication vi) HVAC series VSD s are available for BacNet communication

Options Options RA Bypass Used in high load or startup conditions. Allows the unit to run with as low as 50% fresh air thus reducing the fresh air load of the system. Motorized damper optional. Economy Cycle Used in comfortable ambient conditions. Fresh air bypasses the heat exchanger, optimising energy saving throughout the year. HVAC series VSD s Available on 20kWr and above Rooftop Packaged Unit, HVAC series VSD s for high level communication with BMS system Hot/Cold water coil Rooftop package units can incorporate hot or cold water coils to optimise capacity. De-superheater Reclaim energy from refrigerant to heat water. Suits a variety of applications. High Static Fan Upgrade Fan upgrades available for high flow or high external static pressure drops. Compressor Upgrade Upgrade your compressors to increase refrigerant output. Corrosion Resistant Corrosion resistant packaging available for harsh and corrosive environments Sensible Only Heat Exchanger 80% sensible transfer efficiency for dry climates or any specialist applications

Quick Reference Guide Technical Specifications Refrigerant Capacity Air Flow Overall Dimensions (mm) (Standard Unit) Overall Dimension (mm) (with Economy Cycle) (Standard Unit) Weight Nominal Running Amps (per phase) Phase Electrical Input C.O.P* Model No. kwr L/s H X D X W H X D X W kg Amps kw ACS11RCRTP 11 500 1150X 1330 X 1760 1200 X 1630 X 1950 360 11.1 3 4.2 5.0 ACS16RCRTP 16 750 1150X 1330 X 1760 1200 X 1630 X 1950 420 12.9 3 5.7 5.5 ACS20RCRTP 20 1000 1200 X 1630 X 1950 1300 X 1630 X 2200 500 17.0 3 6.9 5.8 ACS23RCRTP 23 1100 1200 X 1630 X 1950 1300 X 1630 X 2200 580 19.6 3 8.2 5.5 ACS27RCRTP 27 1200 1300 X 1630 X 2200 1850 X 2350 X 2250 610 21.6 3 9.1 6.2 ACS32RCRTP 32 1400 1300 X 1630 X 2200 1850 X 2350 X 2250 660 27.4 3 10.8 5.6 ACS36RCRTP 36 1700 1300 X 1630 X 2200 1850 X 2350 X 2250 780 33.2 3 13.6 5.2 ACL45RCRTP 45 2000 1850 X 2350 X 2250 1965 X 2350 X 2900 1060 33.9 3 16.1 5.3 ACL52RCRTP 52 2300 1850 X 2350 X 2250 1965 X 2350 X 2900 1130 40.9 3 19.7 5.0 ACL60RCRTP 60 2700 1850 X 2350 X 2250 1965 X 2350 X 2900 1320 50.5 3 22.9 5.0 ACL65RCRTP 65 2800 1965 X 2350 X 2900 1965 X 2350 X 3550 1680 52.0 3 23.3 5.2 ACL70RCRTP 70 3200 1965 X 2350 X 2900 1965 X 2350 X 3550 1720 60.6 3 27.3 4.9 ACL82RCRTP 82 3600 1965 X 2350 X 2900 1965 X 2350 X 3550 1760 62.6 3 30.9 5.0 ACL96RCRTP 96 4200 1965 X 2350 X 2900 1965 X 2350 X 3550 1920 77.0 3 36.9 4.9 ACL125RCRTP 125 5000 2210 X 2350 X 3550 2210 X 2350 X 4850 2100 88.2 3 42.3 4.9 *Based on Sydney Cooling Conditions Including Heat Exchanger

Quick Reference Guide Refrigeration Plus Heat Exchanger Performance- Total Cooling* (kwr) Model No. Sydney Brisbane North Queensland Adelaide Melbourne Canberra Darwin Perth Hobart ACS11RCRTP 21.1 23.9 26.5 18.6 16.4 15.0 27.4 18.6 13.7 ACS16RCRTP 31.2 35.4 39.3 27.4 24.1 21.9 40.7 27.4 20.0 ACS20RCRTP 40.2 45.8 51.1 35.2 30.8 27.9 52.9 35.2 25.3 ACS23RCRTP 45.2 51.4 57.2 39.7 34.9 31.7 59.2 39.7 28.9 ACS27RCRTP 56.2 63.0 69.3 50.2 44.9 41.5 71.5 50.2 38.4 ACS32RCRTP 60.3 68.1 75.5 53.3 47.1 43.1 78.0 53.3 39.4 ACS36RCRTP 70.3 79.9 88.8 61.8 54.3 49.4 91.9 61.8 45.0 ACL45RCRTP 85.4 96.6 107.2 75.4 66.6 60.8 110.8 75.4 55.6 ACL52RCRTP 98.5 111.3 123.5 86.9 76.8 70.2 127.6 86.9 64.2 ACL60RCRTP 114.5 129.7 143.9 101.0 89.1 81.3 148.8 101.0 74.4 ACL65RCRTP 121.6 137.2 152.0 107.5 95.2 87.1 157.1 107.5 79.9 ACL70RCRTP 134.6 152.6 169.5 118.6 104.5 95.3 175.2 118.6 87.0 ACL82RCRTP 154.7 174.9 193.9 136.6 120.8 110.4 200.4 136.6 101.2 ACL96RCRTP 180.8 204.4 226.5 159.8 141.3 129.2 234.1 159.8 118.3 ACL125RCRTP 210.7 258.2 287.2 186.1 157.1 150.5 292.8 186.1 121.9 * Based on AIRAH design ambient conditions, 24 o C/50RH% Indoor Conditions Refrigeration Plus Heat Exchanger Performance- Total Heating* (kwr) Model No. Sydney Brisbane North Queensland Adelaide Melbourne Canberra Darwin Perth Hobart ACS11RCRTP 23.5 23.5 21.4 26.4 26.8 32.6 16.5 25.9 28.6 ACS16RCRTP 34.3 34.3 31.1 38.6 39.2 47.9 23.7 37.8 41.9 ACS20RCRTP 44.0 44.0 39.8 49.8 50.6 62.2 30.0 48.8 54.2 ACS23RCRTP 49.9 49.9 45.3 56.3 57.2 70.0 34.5 55.2 61.1 ACS27RCRTP 56.8 56.8 51.8 63.8 64.7 78.7 40.0 62.5 69.0 ACS32RCRTP 66.6 66.6 60.7 74.7 75.8 92.1 46.9 73.3 80.9 ACS36RCRTP 77.3 77.3 70.2 87.2 88.5 108.3 53.4 85.4 94.6 ACL45RCRTP 97.0 97.0 88.6 108.6 110.2 133.5 68.9 106.6 117.4 ACL52RCRTP 111.7 111.7 102.0 125.0 126.9 153.7 79.4 122.7 135.2 ACL60RCRTP 129.3 129.3 118.0 145.0 147.1 178.5 91.4 142.2 156.8 ACL65RCRTP 138.2 138.2 126.4 154.4 156.7 189.3 98.9 151.6 166.8 ACL70RCRTP 151.8 151.8 138.4 170.4 172.9 210.2 106.9 167.1 184.4 ACL82RCRTP 175.4 175.4 160.3 196.3 199.2 241.1 124.9 192.6 212.1 ACL96RCRTP 204.8 204.8 187.2 229.2 232.5 281.4 145.8 224.9 247.6 ACL125RCRTP 235.5 235.5 214.1 260.4 276.6 294.4 149.2 255.3 256.1 * Based on AIRAH design ambient conditions, 21 o C/50% Indoor Conditions

ACL70RCRTP TECHNICAL SPECIFICATIONS UNIT VALUE Supply Air L/s 3200 Rooftop Schematic: Return Air L/s 3200 Outdoor Air L/s 3200 Condenser Air L/s 3000 Exhaust Air L/s 6200 Compressor Qty 2 Refrigerant Charge (R22 / R407C) kg/comp 6.9 Total Compressor Capacity kwr 70 OUTDOOR AIR TO SUPPLY AIR Pressure Drop Heat Exchanger Pa 208 Pressure Drop Evaporator Coil Pa 120 External Static Pressure Up to Pa 300 Total Pressure on Supply Fan Pa 628 SUPPLY FAN Base Dimensions: Fan Speed (max) rpm 1400 Motor Power kw 5.5 Motor Poles 4 Motor Torque Nm 36.4 RETURN AIR TO EXHAUST AIR Pressure Drop Heat Exchanger Pa 208 Pressure Drop Condenser Coil Pa 120 External Static Pressure Up to Pa 250 Total Pressure on Exhaust Fan Pa 578 EXHAUST FAN Fan Speed (max) rpm 1400 Motor Power kw 5.5 Motor Poles 4 Motor Torque Nm 36.4 CONDENSER AIR Fan Qty 2 Air Flow L/s 3000 Fan Speed rpm 1360 COIL SIZE Condenser Coil mm 2110 X 914 Evaporator Coil mm 2110 X 762 Face Velocity Coil Evap m/s 1.99 ELECTRICAL POWERING 415/3/50 Current (MCC) (Comp) A 64 Current (RLA) (Comp) A 36 Supply Fan FLA A 10.8 Supply Fan LRA A 75.6 Exhaust Fan FLA A 10.8 Exhaust Fan LRA A 75.6 Make Up Fan FLA A 3 Nominal Running Current A 61.6/60.6/60.6 Full Load Amps A 89.6/88.6/88.6 Overall Dimensions Height:1965 mm (Body 1865) Width: 2900 mm (Body 2700) Depth: 2350 mm (Body 2270) Weight 1720kg Spigot Size Supply Air (2060 X 700) Return Air (2600 X 740) Exhaust Air (2060 X 880) Outdoor Air (2600 X 975) Sound Pressure Levels db(a) Exhaust @ 1m 63 Hz 57 125 Hz 61 250 Hz 64 500 Hz 74 1000 Hz 71 2000 Hz 72 4000 Hz 71 8000 Hz 61 OA Hz 79 General 70 kw Reverse Cycle Roof Top Package with Dual Stage Heating and Cooling. Allow 1.5m clearance from doors to ensure adequate space for proper service and maintenance Intake @ 4m 63 Hz 44 125 Hz 50 250 Hz 52 500 Hz 66 1000 Hz 55 2000 Hz 53 4000 Hz 49 8000 Hz 37 IA Hz 67